• Title/Summary/Keyword: scale-model

Search Result 8,440, Processing Time 0.033 seconds

Management Efficiency of Korean Information and Communication Enterprise (국내 정보통신업의 경영효율성)

  • Kim, Jong-Ki;Kang, Da-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.1
    • /
    • pp.32-42
    • /
    • 2009
  • Information and communication industry, which has been growing rapidly, is now leading the global economic growth, contributing a ripple effect on general business and economic structure. It is said that information and communication industry enables swift economic growth taking a role as a basic industry of information-oriented society. Especially, rapid technical innovation promotes mutual growth of other related industries and it is technology-intensive. The purpose of this research is to analyze the management efficiency of information and communication industry using DEA method, and finally suggests numerical value for inefficient organizations to improve their efficiency. CCR-I, BCC-I efficiency and RTS(Returns to scale) of 29 companies engaged in information and communication industry was evaluated. With the results, we suggested the model companies for benchmarking in information and communication industry. To summarize, 7 companies were selected with CCR-I efficiency rate 1, and 12 companies with BCC-I efficiency rate 1. RTS was finalized with 8 IRS companies, 10 DRS companies, and 11 CRS companies.

An Analysis of Spatial Characteristics of Environmental-Friendly Certified Farms - Focused on Jeollanam-do - (친환경 인증 농경지의 공간적 특성 분석 - 전라남도를 대상으로 -)

  • Park, Yujin;Gu, Jeong-Yoon;Lee, Sang-Woo;An, Kyungjin;Choi, Jinah;Kim, Sangbum;Park, Se-Rin
    • Journal of Korean Society of Rural Planning
    • /
    • v.29 no.3
    • /
    • pp.79-89
    • /
    • 2023
  • As the demand for environmental-friendly agricultural products continues to rise due to increased concerns regarding food safety and ecosystem conservation, it is becoming important to identify regions and spatial locations where environmental-friendly should be intensively established for production integration. This study aims to analyze the spatial distribution of environmental-friendly certified farms in Jeollanam-do, South Korea. Spatial statistical analysis based on Local Moran's I and Getis-Ord Gi* were used to identify spatial cluster characteristics and landscape indices were utilized to analyze spatial patterns of environmental-friendly certified farms. The results indicated that Haenam-gun, Gangjin-gun, Muan-gun, and Jindo-gun were identified as hotspots, while Muan-gun, Goheung-gun, and Jindo-gun exhibited high connectivity. This suggests that environmental-friendly certified farms in Muan-gun and Jindo-gun were clustered and closely connected to one another. Based on the results of the spatial distribution of environmental-friendly certified farms, areas belonging to the hotspot and with high connectivity should be managed as clustered districts to secure the foundation and system of environmental-friendly certified farms. Areas that belong to cold spots and have low connectivity should be preceded by measures to promote conversion to environmental-friendly agriculture. In addition, it is necessary to make it possible to create a large-scale cluster district through a long-term spatial planning strategy to expand the environmental-friendly certified farms. The findings of this study can provide quantitative data on policies and discussions for developing a model for rural spatial planning.

Power Distribution Optimization of Multi-stack Fuel Cell Systems for Improving the Efficiency of Residential Fuel Cell (주택용 연료전지 효율 향상을 위한 다중 스택 연료전지 시스템의 전력 분배 최적화)

  • TAESEONG KANG;SEONGHYEON HAM;HWANYEONG OH;YOON-YOUNG CHOI;MINJIN KIM
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.4
    • /
    • pp.358-368
    • /
    • 2023
  • The fuel cell market is expected to grow rapidly. Therefore, it is necessary to scale up fuel cells for buildings, power generation, and ships. A multi-stack system can be an effective way to expand the capacity of a fuel cell. Multi-stack fuel cell systems are better than single-stack systems in terms of efficiency, reliability, durability and maintenance. In this research, we developed a residential fuel cell stack and system model that generates electricity using the fuel cell-photovoltaic hybrid system. The efficiency and hydrogen consumption of the fuel cell system were calculated according to the three proposed power distribution methods (equivalent, Daisy-chain, and optimal method). As a result, the optimal power distribution method increases the efficiency of the fuel cell system and reduces hydrogen consumption. The more frequently the multi-stack fuel cell system is exposed to lower power levels, the greater the effectiveness of the optimal power distribution method.

Seismic response of a high-rise flexible structure under H-V-R ground motion

  • We, Wenhui;Hu, Ying;Jiang, Zhihan
    • Earthquakes and Structures
    • /
    • v.23 no.2
    • /
    • pp.169-181
    • /
    • 2022
  • To research the dynamic response of the high-rise structure under the rocking ground motion, which we believed that the effect cannot be ignored, especially accompanied by vertical ground motion. Theoretical analysis and shaking table seismic simulation tests were used to study the response of a high-rise structure to excitation of a H-V-R ground motion that included horizontal, vertical, and rocking components. The use of a wavelet analysis filtering technique to extract the rocking component from data for the primary horizontal component in the first part, based on the principle of horizontal pendulum seismogram and the use of a wavelet analysis filtering technique. The dynamic equation of motion for a high-rise structure under H-V-R ground motion was developed in the second part, with extra P-△ effect due to ground rocking displacement was included in the external load excitation terms of the equation of motion, and the influence of the vertical component on the high-rise structure P-△ effect was also included. Shaking table tests were performed for H-V-R ground motion using a scale model of a high-rise TV tower structure in the third part, while the results of the shaking table tests and theoretical calculation were compared in the last part, and the following conclusions were made. The results of the shaking table test were consistent with the theoretical calculation results, which verified the accuracy of the theoretical analysis. The rocking component of ground motion significantly increased the displacement of the structure and caused an asymmetric displacement of the structure. Thus, the seismic design of an engineering structure should consider the additional P-△ effect due to the rocking component. Moreover, introducing the vertical component caused the geometric stiffness of the structure to change with time, and the influence of the rocking component on the structure was amplified due to this effect.

Fear of Falling and Falls Efficacy with Bone Mineral Density in the Middle and Old Aged Women (재가 중.노년 여성의 골밀도와 낙상두려움 및 낙상효능감에 관한 연구)

  • Lee, Hea-Young;Bak, Won-Sook;Yang, Hyung-In
    • Journal of muscle and joint health
    • /
    • v.16 no.1
    • /
    • pp.5-12
    • /
    • 2009
  • Purpose: The purpose of this study was to investigate bone mineral density(BMD) and fear of falling and falls efficacy in the middle and old aged women over 50 years. Methods: The subjects consisted of 409 women. One-way ANOVA, Pearson's correlations and multiple regression were used to test the BMD, fear of falling and falls efficacy scale by using SPSSWIN 12.0. The BMD of the calcaneus were measured with peripheral dual energy x-ray absorptiometry(DEXA). Results: The average age was 63 years old and the average T-score was -3.21 in patient with osteoporosis, -1.72 with osteopenia, and .13 with normal. There were significant differences in the status of the BMD according to age(p=.000), height(p=.000), weight(p=.000), married status(p=.000), age of menarche(p=.002), and menopause(p=.002). The fear of falling was related with falls efficacy(r=-.247, p=.01), BMD(r=-.337, p=.01). Falls efficacy($\beta$=-.21, p=.000)and BMD($\beta$=-.26, p=.000) were predicting variables of fear of falling. The model explained 13% of the variance in fear of falling(F=27.38, p=.000). Conclusion: Fear of falling and falls efficacy were related with the bone mineral density. Falls efficacy and BMD may be useful for the predicting fear of falling for women in middle and old age. Further studies with assessment of fall-related risk-factors and a longitudinal study are necessary to assess with falls efficacy, and BMD with age.

A Study for Analysis of Micro Heat Grid Configuration and Deduction of Optimal Size in Hydrogen Cities (수소도시 내 마이크로 히트그리드 구성 방안 및 최적 규모 산정 연구)

  • JONGJUN LEE;SEUL-YE LIM;KYOUNG A SHIN;NAMWOONG KIM;DO HYEONG KIM;CHEOL GYU PARK
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.6
    • /
    • pp.845-855
    • /
    • 2022
  • In response to climate change, the world is continuing efforts to reduce fossil fuels, expand renewable energy, and improve energy efficiency with the goal of achieving carbon neutrality. In particular, R&D is being made on the value chain covering the entire cycle of hydrogen production, storage, transportation, and utilization in order to shift the energy supply system to focus on hydrogen energy. Hydrogen-based energy sources can produce heat and electricity at the same time, so it is possible to utilize heat energy, which can increase overall efficiency. In this study, calculation of the optimal scale for hydrogen-based cogeneration and the composition of heat sources were reviewed. It refers to a method of the optimal heat source size according to the external heat supply and heat storage to be considered. The results of this study can be used as basic data for establishing a hydrogen-based energy supply model in the future.

Flood Response Disaster Prevention Facility Simulator Design and Prototype Development Using Spill and Inundation Model (유출·침수모델을 이용한 홍수대응 방재시설 시뮬레이터 설계 및 프로토타입 개발)

  • Seo, Sung Chul;Kim, Ui Hwan;Park, Hyung Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.259-266
    • /
    • 2023
  • Global climate change is increasing, and the damage and scale of localized torrential rains are increasing. Pre-flood analysis simulation results should be derived from rainfall data through rainfall forecasts to prevent flood damage. In addition, it is necessary to control the use and management of flood response disaster prevention facilities through immediate decision-making. However, methods using spills and flood models such as XPSWMM and GATE2018 are limited due to professional usability and complex analytical procedures. Prototype (flood disaster prevention facility simulator) of this study is developed by calculating rainfall (short-term and long-term) using CBD software development methods. It is also expected to construct administrator and user-centric interfaces and provide GIS and visible data (graphs, charts, etc.).

Length-based stock assessment of the pacific yellowtail emperor in the Southern Sulawesi, Indonesia

  • I Nyoman Suyasa;Alifah Fitam Rakhma Sari;Siska Agustina;Rian Prasetia;Ratna Suharti;Toni Ruchimat;Budy Wiryawan;Irfan Yulianto
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.3
    • /
    • pp.216-223
    • /
    • 2023
  • Pacific yellowtail emperor, Lethrinus atkinsoni Seale, 1910, is one of the most targeted reef fish species in Southern Sulawesi, Indonesia. Therefore, assessing its stock is important to understand the condition of the population, providing valuable inputs for sustainable fisheries management in the area. Here we assess the stock condition of L. atkinsoni in Southern Sulawesi, Indonesia, using the length-based spawning potential ratio model. A total of 4,887 individuals were collected from commercially small-scale fishers from January to October 2022. The total length, sex, and gonad maturity of the individuals were examined. We observed that the fish length ranged from 10.5 to 39.5 cm, with an average length of 23.3 cm. The sex ratio was equal (1:1.2) between male and female individuals. Length at first maturity and length at first capture were 23.4 and 19.6 cm, respectively. In addition, we observed a growth coefficient of 0.45/year, with an asymptotic length of 41.14 cm and natural mortality of 0.6/year. Based on these life history parameters, we observed the spawning potential ratio (SPR) value of 12%, indicating an unsustainable fishery level (SPR of < 30%). Further concerns related to the sustainability of the species and strategy to rebuild stock of the L. atkinsoni in Southern Sulawesi are of utmost importance.

Evaluation of Dissipation Behavior of Excess Pore Pressure in Liquefied Sand Deposit Using Centrifuge Tests (원심모형실험을 이용한 액상화 모래지반의 과잉간극수압 소산거동 분석)

  • Kim Sung-Ryul;Ko Hon-Yim;Kim Myoung-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2006
  • Soil liquefaction occurs by complex dynamic interaction between soil particles and pore fluid. Therefore, experimental researches have been widely performed to analyze liquefaction phenomena. In this research, centrifuge tests were performed to analyze the liquefaction behavior of horizontal sand ground. Centrifugal acceleration was 40g and the thickness of model ground was 25cm, which simulates 10m thickness in prototype scale. Viscous fluid was used as pore fluid to remove the time scaling difference between dissipation and dynamic shaking. Test results showed that the dissipation of excess pore pressure is the combined behavior of solidification and consolidation. In addition, the solidification rate, the ground acceleration amplitude, and the dynamic permeability during solidification were influenced by the confining pressure.

The Characteristics of Stress Distribution on Two-arch Tunnel's Pillar due to Surface Loads in the Discontinuous Rock Mass (불연속성 암반에 위치한 2-아치 터널에서 지표면 하중 작용시 필러에 전달되는 응력 특성)

  • Kim, Hong-Moon;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.5
    • /
    • pp.65-73
    • /
    • 2009
  • Large scale model tests and numerical analyses are performed to investigate the stress distribution of pillar due to surface loading nearby two-arch tunnel which is constructed in the regularly jointed rocks. It is observed that the influence of discontinuities on the stress distribution in the discontinuous rock mass and the underground stresses induced by surface loading are greater than those of linear elastic theory. Especially, lines of equal stresses are developed to the direction of inclination according to the inclined grade. In cases of discontinuities imbedded in parallel with or vertical to the ground, the pressure bulbs are formed symmetrically, however, the inclined ones result in stress distribution in parallel with and vertical to the planes of discontinuities. Results indicated that stress distribution is seriously affected by the angle of discontinuity. When stresses propagating to the pillar need to be estimated, relative location of surface loading, grade of discontinuous plane, and location of two-arch tunnel should be carefully considered.