• Title/Summary/Keyword: sand column

Search Result 227, Processing Time 0.025 seconds

A column study of effect of filter media on the performance of sand filter

  • Kim, Tae-hoon;Oh, Heekyong;Eom, Jungyeol;Park, ChulHwi
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.247-255
    • /
    • 2020
  • Sand filter is a key unit process for particle removal in water purification treatments. Its long-standing use is due to on-site customized retrofit. Proper selection of filter media is one of the retrofit approaches to improve filter performance. This study described a series of controlled laboratory column tests and examined the effects of media property on filtration and backwash. When sand media of 0.51 mm in effective size was replaced by sand of 0.60 mm, the filter run increased up to 5 times in the given bed depth. The change of media property required an increase of backwash rate by 0.05 m/min to satisfy the requirement of bed expansion, more than 20%. When the anthracite was changed with lower effective size and uniformity coefficient, correlation with sand in the filter bed could be satisfied within the permissible error between media and bulk characteristics. Besides, this selection resulted in a well-stratified configuration of media layers after bed expansion. The column study showed that the correlation of property between the dual media had a significant effect on the filter productivity and backwash interval.

Differences in Fraction of Na-Zeolite Particles Passed through Sand Columns Filled with Sand Particles in Different Sizes (입경(粒徑)이 다른 모래의 Column 내에서 시용(施用)된 Na-Zeolite의 이동입경별(移動粒徑別) 이동양상(移動樣相))

  • Kang, Shin-Jyung;Choi, Jyung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.18 no.3
    • /
    • pp.240-246
    • /
    • 1985
  • This study was conducted to estimate the proper particle size of Zeolite particle as the soil conditioner for sandy soil. On sand columns filled with different size of sand fractions, Zeolite particles of different size were applied. Tap water was percolated through those columns under the same water level as paddy soil during rice growth. The > 0.1mm fraction of Zeolite was not vertically moved although the water was percolated for 96 hours. The < 0.1mm fraction of Zeolite was moved out 85.7% in 2-1mm, 32.64% in 1-0.5mm, and 24.5% in 0.5-0.25mm sand column, respectively. The proper diameter of Zeolite particle for amelioration of sandy soils widely distributed around river side in Korea was estimated as 0.25-0.1mm fraction in consideration of its pore size.

  • PDF

Evaluation of particulate removal in slow sand filtration processes (완속여과 공정에서 전처리 공정 도입에 따른 입자제거 효율평가)

  • Kim, Seong-Su;Bae, Chul-Ho;Park, No-Suk;Kang, Suk-Hyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.461-466
    • /
    • 2008
  • Because of their simplicity, efficiency, and economy, slow sand filters are appropriate means of water treatment for small water systems. In this study, the effect of filtration velocity and dirty skin (Schmutzdecke) was evaluated on the performance of turbidity removal. Also, removal characteristics of particulate were investigated in the case of the usage of non-woven fabric on the surface of sand and the application of PCF as pretreatment process. Comparative column tests were carried out for the various operation condition. From the result of column tests, filtration velocity had little effect on the turbidity removal rate. The formation of algal biofilm on the surface of media is helpful in turbidity removal, while non-woven fabric is not as effective as expected. The relative contribution of biomass and accumulated particulates to head loss development in slow sand filters requires further study.

Characteristics of Settling and Consolidation Behavior for Non-Plastic Dredged Soils (비소성 준설토의 침강-압밀 거동 특성)

  • Park, Yun-Gyun;Park, Byung-Soo;Jeong, Gil-Soo;Yoo, Nam-Jea
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.251-261
    • /
    • 2004
  • A series of column test with a silty marine soil mixed with Jumunjin Standard Sand were performed to investigate the characteristics of settling and consolidation of non-plastic dredged soils. Column tests were carried out by using the separable column to measure the grain size distribution of consolidated layer. Column tests were performed with changing the mixing ratio of Jumunjin Standard Sand to the silty marine soil, initial water content of slurry and initial height of slurry. Height of interface of slurry was monitored during tests and grain size distribution tests were carried out after finishing tests. Influencing factors on the particle segregation, eventually to the characteristics of settling and consolidation of non-plastic soil, were analyzed on the thesis of test results. As results of column tests, the mixing ratio of sand to the silty marine soil and the initial water content of slurry were known to affect the characteristics of settling and consolidation resulted in significant particle segregation of slurry. Initial height of slurry was found not to affect seriously to particle segregation.

  • PDF

Soluble Manganese Removal Using Manganese Oxide Coated Media (MOCM) (산화망간피복여재를 이용한 용존망간 제거)

  • Kim, Jinkeun;Jeong, Sechae;Ko, Suhyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.813-822
    • /
    • 2006
  • Soluble manganese removal was analyzed as a function of filter media, filter depth, presence or absence of chlorination, and surface manganese oxide concentration in water treatment processes. Sand, manganese oxide coated sand (MOCS), sand+MOCS, and granular activated carbon(GAC) were used as filter media. Manganese removal, surface manganese oxide concentration, turbidity removal, and regeneration of MOCS in various filter media were investigated. Results indicated that soluble manganese removal in MOCS was rapid and efficient, and most of the removal happened at the top of the filter. When filter influent (residual chlorine 1.0mg/L) with an average manganese concentration of 0.204mg/L was fed through a filter column, the sand+MOCS and MOCS columns can remove 98.9% and 99.2% of manganese respectively on an annual basis. On the other hand, manganese removal in sand and the GAC column was minimal during the initial stage of filtration, but after 8 months of filter run they removed 99% and 35% of manganese, respectively. Sand turned into MOCS after a certain period of filtration, while GAC did not. In MOCS, the manganese adsorption rate on the filter media was inversely proportional to the filter depth, while the density of media was proportional to the filter depth.

Laboratory Tests of Chromium-51 Complexes for teak Detection in Pipes Carrying A Liquid Flow

  • Kim, You-Sun;Lee, Byung-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.231-237
    • /
    • 1974
  • For detection and localization of leaks in closed vessels or pipes carrying liquid flow, $^{51}$ Cr-EDTA and $^{51}$ Cr-DTPA were synthesized and, the column and batch equilibrium experiments were carried out. In the column experiment, the recovery of $^{51}$ Cr-EDTA is 100% in quartz sand and 80.9% in steel sawdust, and that of $^{51}$ Cr-DTPA is 77.4% in quartz sand and 6.4% in steel sawdust. The recovery curve. $^{51}$ Cr-DTPA system in steel sawdust does not show a certain plateau, exceptionally. In general, $^{51}$ Cr-EDTA is adsorbed less than $^{51}$ Cr-DTPA. In the batch equilibrium experiment, the distribution coefficients (Kd) and effect of pH were investigated by using quartz sand, montmorillonite, steel sawdust, and mixed cement raw material as media. In general, the Kd values for $^{51}$ Cr-EDTA are lower than that of $^{51}$ Cr-DTPA. The Kd values for $^{51}$ Cr-EDTA are almost zero at pH 6.0, 7.0, and 8.0.

  • PDF

Recycling Water Treatment of Aquaculture by Using DynaSand Filter II. Effect of Coating on Removal of Bacteria and Virus in Sand Columns (상향류식 연속 역세 여과를 이용한 양어장 순환수 재리용 II. 여과사의 표면처리에 의한 세균 및 바이러스 처리율 검토)

  • 박종호;조규석;황규덕;김이오
    • Journal of Aquaculture
    • /
    • v.16 no.2
    • /
    • pp.76-83
    • /
    • 2003
  • To improve the efficiency of removal of bacteria and virus with DynaSand Filters used for treatment of recycling wastewater from aquaculture, effect of biofilm formation on bacterial transport through coated sand was estimated. At the neutral pH (pH 7.0), the coated sand was positive of zeta potential (surface charge). Column experiments were also carried out to test the effect of uncoated sand as well as coated sand with Al and Fe. The coated sand influenced more significantly the surface properties, adsorption and transport than the uncoated sand. The leaching batch system investigated for synthetic water showed concentrations of 7.47, 4.80, 20.89 and 7.23 mg/L for the uncoated sand, coated sand with Al, Fe and Al+Fe, respectively. Hence there are significant differences among the tested coatings with reference to bacterial transport and surface properties.

나노 크기 적철석 입자 피복 모래를 이용한 지하수내 비소 3가와 5가의 제거 기술 개발

  • 고일원;이철효;이상우;김주용;김경웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.78-82
    • /
    • 2003
  • Development of hematite-coated sand was evaluated for the application of the PRB (permeable reactive barrier) in the arsenic-contaminated subsurface of the metal mining areas. The removal efficiency of As(III) and As(V), the effect of anion competition and the capability of arsenic removal in the flow system were investigated through the experiments of adsorption isotherm, arsenic removal kinetics against anion competition and column removal. Hematite-coated sand followed a linear adsorption isotherm with high adsorption capacity at low level concentrations of arsenic (< 1.0 mg/l). When As(III) and As(V) underwent adsorption reactions in the presence of anions (sulfate, nitrate and bicarbonate), sulfate caused strong inhibition of arsenic removal, and bicarbonate and nitrate caused weak inhibition due to specific and nonspecific adsorption onto hematite, respectively. In the column experiments, high content of hematite-coated sand enhance the arsenic removal, but the amount of the arsenic removal decreased due to the higher affinity of As(V) than As(III) and reduced adsorption kinetics in the flow system, Therefore, the amount of hematite-coated sand, the adsorption affinity of arsenic species and removal kinetics determined the removal efficiency of arsenic in the flow system. arsenic, hematite-coated sand, permeable reactive barrier, anion competition, adsorption.

  • PDF

The Importance of Reaction Mechanisms in Interpreting the Arsenic Reactive Transport of FeS-coated Sand Column

  • Han, Young-Soo;Demond, Avery H.;Hayes, Kim F.
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.5
    • /
    • pp.1-10
    • /
    • 2015
  • FeS, as a natural reduced iron mineral, has been recognized to be a viable reactive material for As(III) sequestration in natural and engineered systems. In this study, FeS-coated sand packed columns were tested to evaluate the As(III) removal capacities under anaerobic conditions at pH 5, 7 and 9. The column obtained As(III) removal capacity was then compared with the capacity result obtained from batch reactors. In the comparison, two different approaches were used. The first approach was used the total As(III) removal capacity which method was proved to be useful for interpreting pH 5 system. The second approach was used to consider sorption non-linearity and proved to be useful for interpreting the pH 9. The results demonstrated that a mechanistic understanding of the different removal processes at different pH conditions is important to interpret the column experimental results. At pH 5, where the precipitation of arsenic sulfide plays the major role in the removal of arsenic, the column shows a greater removal efficiency than the batch system due to the continuous dissolution of sulfide and precipitation of arsenic sulfide. At pH 9, where adsorption mainly governs the arsenic removal, the sorption nonlinearity should be considered in the estimation of the column capacity. This study highlighted the importance of understanding reaction mechanism to predict column performance using batch-obtained experimental results.

The study on the Characteristics of Ultimate Bearing Capacity and Major Design Parameters for Single Stone Column (단일 쇄석다짐말뚝의 지지력 특성과 주요 설계 파라미터에 관한 고찰)

  • Chun, Byung-Sik;Kim, Won-Cheul;Jo, Yang-Woon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.552-560
    • /
    • 2004
  • Stone column is a soil improvement method and can be applicable for loose sand or weak cohesive soil. Since the lack of sand in Korea, stone column seems one of the most adaptable approach for poor ground as a soil improvement method. However, this method was not studied for practical application. In this paper, the most effective design parameters for the being capacity of stone column were studied. The parametric study of major design factors for single stone column was carried out under the bulging and general shear failure condition, respectively. Especially, a test result of single stone column by static load was compared with the bearing capacity values of suggested formulas. The analysis result showed that the ultimate bearing capacity by the formula was much less than the measured value by the static load test. Especially, the result of the parametric study under general shear failure condition showed that the bearing capacity has apparent difference between each suggested formulas with the variation of the major design parameters. Therefore, the result of this study can be a suggestion which is applicable for the field test and the future research.

  • PDF