• Title/Summary/Keyword: sampling rate of frequency

Search Result 276, Processing Time 0.022 seconds

Design of Real-Time Autonomic Nervous System Evaluation System Using Heart Instantaneous Frequency

  • Noh, Yeon-Sik;Park, Sung-Jun;Park, Sung-Bin;Yoon, Hyung-Ro
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.576-583
    • /
    • 2008
  • In this study, we attempt to design a real-time autonomic nervous system(ANS) evaluation system usable during exercise using heart instantaneous frequency(HIF). Although heart rate variability(HRV) is considered to be a representative signal widely used ANS evaluation system, the R-peak detection process must be included to obtain an HRV signal, which involves a high sampling frequency and interpolation process. In particular, it cannot accurately evaluate the ANS using HRV signals during exercise because it is difficult to detect the R-peak of electrocardiogram(ECG) signals with exposure to many noises during exercise. Therefore, in this study, we develop the ground for a system that can analyze an ANS in real-time by using the HIF signal circumventing the problem of the HRV signal during exercise. First, we compare the HRV and HIF signals in order to prove that the HIF signal is more efficient for ANS analysis than HRV signals during exercise. Further, we performed real-time ANS analysis using HIF and confirmed that the exerciser's ANS variation experiences massive surges at points of acceleration and deceleration of the treadmill(similar to HRV).

SNR-independent Methods for Estimating Maximum Doppler Frequency (최대 도플러 주파수 추정 시 대역 조절을 통한 부가 잡음의 영향 완화 기법)

  • Yu Hyun-kyu;Park Goo-hyun;Oh Seong-Mok;Kang Chang-eon;Hong Dae-sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.475-480
    • /
    • 2005
  • Information of the maximum Doppler frequency enable to optimize many channel-adaptive techniques and radio resource management methods for mobile radio communication systems. In this paper, we propose two maximum Doppler frequency estimators which are based on the level crossing rate(LCR) and the covariance function (COV). To eliminate the effect of additive noise, we analyze the conditions for the estimators independent of the signal-to-noise ratio(SNR) and implement the conditions with a simple downsampling process. The proposed methods achieve good SNR-independent performance.

Characteristics of Nonpoint Source Pollutant Loads from Forest watershed with Various Water Quality Sampling Frequencies (수질샘플빈도에 따른 산림유역의 비점원오염부하특성)

  • Shin, Min-Hwan;Shi, Yong-Chul;Heo, Sung-Gu;Lim, Kyoung-Jae;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.50 no.2
    • /
    • pp.65-71
    • /
    • 2008
  • A monsoon season monitoring data from June to September, 2005 of a small forested watershed located at the upstream of the North Han River system in Korea was conducted to analyze the flow variations, the NPS pollutant concentrations, and the pollution load characteristics with respect to sampling frequencies. During the 4-month period, 1,423 mm or 79.2% of annual rainfall(1,797 mm) were occurred and more than 77%, 54% and 68% of annual T-N, $NO_3$-N and T-P loads discharged. Flow rate was continuously measured with automatic velocity and water level meters and 58 water quality samples were taken and analyzed. It was analyzed that the flow volume by random measurement varied very widely and ranged from 79% to 218% of that of continuous measurement. It was recommended that flow measurement of small forested watersheds should be continuously measured with automated flow meters to precisely measure flow rates. Flow-weighted mean concentrations of T-N, $NO_3$-N and T-P during the period were 2.114 mg/L, 0.836 mg/L, and 0.136 mg/L, respectively. T-N, $NO_3$-N and T-P loads were sensitive to the number of samples. And it was analyzed that in order to measure the pollution load within the error of 10% to the true load, the rate of sampling frequency should be higher than 89.7% of the sample numbers that were required to compute the true pollution load. If it is compared to selected foreign research results, about 10 water samples for each rainfall event were needed to compute the pollution load within 10% error. It is unlikely in Korea and recommended that thorough NPS pollution monitoring studies are required to develop the standard monitoring procedures for reliable NPS pollution quantification.

An Iterative Technique for Real-Time Tracking of Power System Harmonics

  • Sidhu, T.S.;Zadeh, M.R.D.;Pooranalingam, P.J.;Oh, Yong-Taek
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.319-327
    • /
    • 2011
  • An iterative technique based on orthogonal filters and frequency tracking is proposed to estimate harmonic components in power systems. The technique uses frequency interpolation to estimate fundamental frequency and harmonics when the nominal frequency of the signal is a non-integer value. Due to the number of computations involved during the generation of filter coefficients, an offline computation is suggested. Beneficial features of the proposed technique include fixed sampling rate and fixed data window size. The performance of the proposed technique is examined by simulating different power system operating conditions and evaluating the data from these simulations. A technique based on Fast Fourier Transform is also used to estimate the harmonic components for all the simulated signals. These estimates are compared with those obtained from the proposed technique. Results show that the proposed technique can converge to the accurate fundamental frequency and therefore, provide accurate harmonic components even when the fundamental frequency is not equal to the nominal frequency.

Design of High Speed Analog Input Card for Ultrasonic Testing (초음파 탐상을 위한 고속 아날로그 입력 카드의 설계)

  • 이병수;이동원;박두석
    • Journal of the Korea Society of Computer and Information
    • /
    • v.5 no.4
    • /
    • pp.62-68
    • /
    • 2000
  • It was designed a high-speed analog input card that is a important device of ultrasonic testing flaw detector in the middle of non-destructive testing in this Paper. The A/D Board is inquired high-speed sampling rate and fast data acquisition system. This pater shows a design that has a function of Peak- Detection for ultrasonic testing by ISA Bus type and a 50MHz of A/D converter in order to do sampling more than quadruple frequency of transducer frequency.

  • PDF

High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers. (헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정)

  • 김승우;김민석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.203-206
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state-of-the-art reaches the region of sub-nanometers. We propose a new scheme of phase-measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with electrically generated reference signal. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special from of frequency up-down counting technique is combined with the super-heterodyning. This alloys performing required phase unwrapping simply by using programmable digital gates without 2$\pi$ ambiguities up to the maximum velocity of 2.35 m/s.

  • PDF

FREQUENCY HISTOGRAM MODEL FOR LINE TRANSECT DATA WITH AND WITHOUT THE SHOULDER CONDITION

  • EIDOUS OMAR
    • Journal of the Korean Statistical Society
    • /
    • v.34 no.1
    • /
    • pp.49-60
    • /
    • 2005
  • In this paper we introduce a nonparametric method for estimating the probability density function of detection distances in line transect sampling. The estimator is obtained using a frequency histogram density estimation method. The asymptotic properties of the proposed estimator are derived and compared with those of the kernel estimator under the assumption that the data collected satisfy the shoulder condition. We found that the asymptotic mean square error (AMSE) of the two estimators have about the same convergence rate. The formula for the optimal histogram bin width is derived which minimizes AMSE. Moreover, the performances of the corresponding k-nearest-neighbor estimators are studied through simulation techniques. In the absence of our knowledge whether the shoulder condition is valid or not a new semi-parametric model is suggested to fit the line transect data. The performances of the proposed two estimators are studied and compared with some existing nonparametric and semiparametric estimators using simulation techniques. The results demonstrate the superiority of the new estimators in most cases considered.

Research on Multiple-image Encryption Scheme Based on Fourier Transform and Ghost Imaging Algorithm

  • Zhang, Leihong;Yuan, Xiao;Zhang, Dawei;Chen, Jian
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.315-323
    • /
    • 2018
  • A new multiple-image encryption scheme that is based on a compressive ghost imaging concept along with a Fourier transform sampling principle has been proposed. This further improves the security of the scheme. The scheme adopts a Fourier transform to sample the original multiple-image information respectively, utilizing the centrosymmetric conjugation property of the spatial spectrum of the images to obtain each Fourier coefficient in the most abundant spatial frequency band. Based on this sampling principle, the multiple images to be encrypted are grouped into a combined image, and then the compressive ghost imaging algorithm is used to improve the security, which reduces the amount of information transmission and improves the information transmission rate. Due to the presence of the compressive sensing algorithm, the scheme improves the accuracy of image reconstruction.

Digital demodulator design and characteristics of AM and FM signals by undersampling scheme (Undersampling 기법에 의한 AM 및 FM 신호의 디지털 복조기 설계와 특성)

  • 손태호;박종연
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.116-126
    • /
    • 1997
  • As the digital system with high sampling rates is required to process numerous data, it is difficult to realize the real time processing for this system. By using the nonlinear energy tracking signal operator, in this paper four kinds of AM/FM demodulators are proposed and designed by the undersampling scheme of decreasing the sampling rate. Particularly, the undersampling frequency and 3dB bandwidth are controllable of these systems and their conditions are respectively. Through the analysis of the designed detectors, useful results are obtained in respect to characteristics and errors.

  • PDF

ZigBee-based Real-time Wireless Networked Motor Control System (지그비 기반의 실시간 무선 네트워크 모터 제어시스템)

  • Park, Jung-Il
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.2
    • /
    • pp.103-109
    • /
    • 2020
  • This paper finds solutions for using ZigBee in wireless networked control system (WNCS). The round trip time delay and packet loss rate of the WNCS are measured. On the basis of these measured data, a playback buffer is used to solve the variable time delay in WNCS, and a Smith predictor is introduced to compensate for the time delay. The WNCS was able to be actually constructed to perform DC motor position control with 40 Hz sampling frequency.