• Title/Summary/Keyword: safety limits

Search Result 892, Processing Time 0.03 seconds

The Obligation of Return Unjust Enrichment or Compensation for the Use of Flight Safety Zone -Seoul High Court Judgment 2018Na2034474, decided on 2018. 10. 11.- (비행안전구역의 사용에 대한 부당이득반환·손실 보상 의무의 존부 -서울고등법원 2018. 10. 11. 선고 2018나2034474 판결-)

  • Kwon, Chang-Young;Park, Soo-Jin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.35 no.1
    • /
    • pp.63-101
    • /
    • 2020
  • 'Flight safety zone' means a zone that the Minister of National Defense designates under Articles 4 and 6 of the Protection of Military Bases and Installations Act (hereinafter 'PMBIA') for the safety of flight during takeoff and landing of military aircrafts. The purpose of flight safety zone is to contribute to the national security by providing necessary measures for the protection of military bases and installations and smooth conduct of military operations. In this case, when the state set and used the flight safety zone, the landowner claimed restitution of unjust enrichment against the country. This article is an analysis based on the existing legal theory regarding the legitimacy of plaintiff's claim, and the summary of the discussion is as follows. A person who without any legal ground derives a benefit from the property or services of another and thereby causes loss to the latter shall be bound to return such benefit (Article 741 of the Civil Act). Since the subject matter is an infringing profit, the defendant must prove that he has a legitimate right to retain the profit. The State reserves the right to use over the land designated as a flight safety zone in accordance with legitimate procedures established by the PMBIA for the safe takeoff and landing of military aircrafts. Therefore, it cannot be said that the State gained an unjust enrichment equivalent to the rent over the land without legal cause. Expropriation, use or restriction of private property from public necessity and compensation therefor shall be governed by Act: provided, that in such a case, just compensation shall be paid (Article 23 (1) of the Constitution of The Republic of KOREA). Since there is not any provision in the PMBIA for loss compensation for the case where a flight safety zone is set over land as in this case, next question would be whether or not it is unconstitutional. Even if it is designated as a flight safety zone and the use and profits of the land are limited, the justification of the purpose of the flight safety zone system, the appropriateness of the means, the minimization of infringement, and the balance of legal interests are still recognized; thus just not having any loss compensation clause does not make the act unconstitutional. In conclusion, plaintiff's claim for loss compensation based on the 'Act on Acquisition of and Compensation for land, etc. for Public Works Projects', which has no provision for loss compensation due to public limits, is unjust.

The Measurement of Combustible Characteristics of n-Undecane (노말언데칸의 연소특성치의 측정)

  • Ha, Dong-Myeong
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.11-17
    • /
    • 2013
  • For the safe handling of n-undecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-undecane were calculated. The lower flash points of n-undecane by using closed-cup tester were measured $59^{\circ}C$ and $67^{\circ}C$. The lower flash points of n-undecane by using open cup tester were measured $67^{\circ}C$ and $72^{\circ}C$, respectively. The fire point of n-undecane by using Cleveland open cup tester was measured $74^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-undecane. The experimental AIT of n-undecane was $198^{\circ}C$. The estimated lower and upper explosion limit by using measured lower flash point $59^{\circ}C$ and upper flash point $83^{\circ}C$ for n-undecane were 0.65 Vol.% and 2.12 Vol.%.

Highly Efficient Gene Expression in Rabbit Synoviocytes Using EBV-Based Plasmid (가토 윤활막 세포에서 EBV-Based 플라스미드를 사용한 효율적인 유전자 발현)

  • Kim, Jin Young;Oh, Sang Taek;Youn, JeeHee;Lee, Suk Kyeong
    • IMMUNE NETWORK
    • /
    • v.4 no.3
    • /
    • pp.190-197
    • /
    • 2004
  • Background: Rheumatoid arthritis (RA) is an autoimmune disorder characterized by chronic synovial inflammation which leads to joint destruction. Gene therapy of RA targets the players of inflammation or articular destruction. However, viral vectors have safety problems and side effects, while non-viral vectors suffer from inefficient gene transfer and fast loss of gene expression. To overcome the limits of non-vial vectors, an EBV-based plasmid which is known to exert prolonged high level gene expression can be used. Methods: pEBVGFP, pEBVIL-10, and pEBVvIL-10 were constructed by cloning GFP, IL-10, and vIL-10 genes into an EBV-based plasmid, respectively. The pGFP was used as a control plasmid. Each constructs were lipofected into HIG-82 rabbit synoviocytes. The expression of GFP was monitored by FACS and confocal microscopy. IL-10 and vIL-10 expressions were measured by ELISA. Results: GFP expression 2 days after transfection was achieved in 33.2% of cells. GFP-expressing cells transfected with pGFP decreased rapidly from 4 days after transfection and disappeared completely by 11 days. Cells transfected with pEBVGFP began to decrease slowly from 4 days. But GFP expression was detected for over 35 days. In addition, HIG-82 cells transfected with pEBVIL-10 ($44.6{\pm}1.5ng/ml$) or pEBVvIL-10 ($51.0{\pm}5.7ng/ml$) secreted these cytokines at high levels. High level cytokine production by hygromycin selection was maintained at least for up to 26 days after transfection. Conclusion: These results suggest that the EBV-based plasmid has a potential to improve non-viral gene transfer system and may be applicable to treat RA without the drawbacks of viral vectors.

The Analysis of Robot Education Unit in the Practical Arts Textbooks According to 2015 Revised Curriculum (2015 개정 실과교과서의 로봇교육 체제 분석)

  • Park, SunJu
    • Journal of The Korean Association of Information Education
    • /
    • v.24 no.1
    • /
    • pp.99-106
    • /
    • 2020
  • In this paper, we analyzed the units related to robot education in the Practical Arts textbooks according to the 2015 revised curriculum. As a result, all textbooks had a common system of introduction, development, and organization, and all of them showed a similar flow. Learning objectives were presented in all textbooks, but no affective goals were presented except cognitive and functional goals. The contents of robot learning suggest the meaning and type of robots, the structure and sensors of robots, and the activities of making robots, but the contents of robot ethics, the production and activities of various robot works, and the use of robots in the problem solving process are not presented. The assembly robot and the infrared sensor are used in common, and it consists of presenting robot production and control training materials in experience activities and arranging units through evaluation, and the A, C, and F textbooks also provide the unit auxiliary data. In the future, it will be necessary to include the contents of robot ethics education centered on the design/manufacturer and user-oriented robot ethics such as the recognition of the limits of robots, the principles of using robots correctly, safety education, personal information and privacy protection.

Cell-SELEX Based Identification of an RNA Aptamer for Escherichia coli and Its Use in Various Detection Formats

  • Dua, Pooja;Ren, Shuo;Lee, Sang Wook;Kim, Joon-Ki;Shin, Hye-su;Jeong, OK-Chan;Kim, Soyoun;Lee, Dong-Ki
    • Molecules and Cells
    • /
    • v.39 no.11
    • /
    • pp.807-813
    • /
    • 2016
  • Escherichia coli are important indicator organisms, used routinely for the monitoring of water and food safety. For quick, sensitive and real-time detection of E. coli we developed a 2'F modified RNA aptamer Ec3, by Cell-SELEX. The 31 nucleotide truncated Ec3 demonstrated improved binding and low nano-molar affinity to E. coli. The aptamer developed by us out-performs the commercial antibody and aptamer used for E. coli detection. Ec3(31) aptamer based E. coli detection was done using three different detection formats and the assay sensitivities were determined. Conventional Ec3(31)-biotin-streptavidin magnetic separation could detect E. coli with a limit of detection of $1.3{\times}10^6CFU/ml$. Although, optical analytic technique, biolayer interferometry, did not improve the sensitivity of detection for whole cells, a very significant improvement in the detection was seen with the E. coli cell lysate ($5{\times}10^4CFU/ml$). Finally we developed Electrochemical Impedance Spectroscopy (EIS) gap capacitance biosensor that has detection limits of $2{\times}10^4CFU/mL$ of E. coli cells, without any labeling and signal amplification techniques. We believe that our developed method can step towards more complex and real sample application.

Development of Korean Medical Psychotherapy and Preliminary Clinical Trial for Post Traumatic Stress Disorder (외상 후 스트레스 장애에 대한 한방정신요법 기반 심리치료 개발 및 예비적 임상시험)

  • Kim, Jin-Hyung;Sue, Joo-Hee;Lee, Go-Eun;Kim, Nam-Kwen;Choi, Sung-Youl;Lyu, Yeoung-Su;Kang, Hyung-Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.26 no.1
    • /
    • pp.49-61
    • /
    • 2015
  • Post traumatic stress disorder (PTSD) is an anxiety disorder that usually occurs after suffering from a psychological trauma that can not threatening events, which is one of the individual's subjective pain and their families and the larger society due to the chronic disease burden results. Treatment with a medication, as well as cognitive behavioral therapy (CBT), exposure therapy, prolonged exposure therapy (PE), eye-movement desensitizing, and reprocessing (EMDR) are preferentially performed, including psychotherapy. Korean medical psychotherapy consists of a wide range of manual therapy, but it does not have systematically screening limits. This study was developed by Korean medical psychotherapy program for PTSD, and it was carried out as a preliminary clinical trial for validity. The Korean medical psychotherapy program for PTSD consists of four stages as follows: building chapter of safety, flow and send, accept, and integration. Based on this preliminary clinical study of PTSD, seven patients were treated for 2 hours per week for 5 weeks. We report the meaningful results gained by observing the changes in IES-RK points, questionnaire on five-faceted mindfulness, quality of life, anxiety, depression, insomnia, hwabyung scale, HRV, and EEG, before and after the Korean medical psychotherapy program.

Seismic response of current RC buildings in Kathmandu Valley

  • Chaulagain, Hemchandra;Rodrigues, Hugo;Spacone, Enrico;Varum, Humberto
    • Structural Engineering and Mechanics
    • /
    • v.53 no.4
    • /
    • pp.791-818
    • /
    • 2015
  • RC buildings constitute the prevailing type of construction in earthquake-prone region like Kathmandu Valley. Most of these building constructions were based on conventional methods. In this context, the present paper studied the seismic behaviour of existing RC buildings in Kathmandu Valley. For this, four representative building structures with different design and construction, namely a building: (a) representing the non-engineered construction (RC1 and RC2) and (b) engineered construction (RC3 and RC4) has been selected for analysis. The dynamic properties of the case study building models are analyzed and the corresponding interaction with seismic action is studied by means of non-linear analyses. The structural response measures such as capacity curve, inter-storey drift and the effect of geometric non-linearities are evaluated for the two orthogonal directions. The effect of plan and vertical irregularity on the performance of the structures was studied by comparing the results of two engineered buildings. This was achieved through non-linear dynamic analysis with a synthetic earthquake subjected to X, Y and $45^{\circ}$ loading directions. The nature of the capacity curve represents the strong impact of the P-delta effect, leading to a reduction of the global lateral stiffness and reducing the strength of the structure. The non-engineered structures experience inter-storey drift demands higher than the engineered building models. Moreover, these buildings have very low lateral resistant, lesser the stiffness and limited ductility. Finally, a seismic safety assessment is performed based on the proposed drift limits. Result indicates that most of the existing buildings in Nepal exhibit inadequate seismic performance.

Application of Toxicity Identification Evaluation Procedures for Toxic Effluents from the Aluminum Rolling Industry (알루미늄 가공 공장 배출 방류수의 독성 원인물질 탐색)

  • Ra, Jin-Sung;Lee, Jiho;Kim, Ki-Tae
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.305-313
    • /
    • 2015
  • Objectives: The objective of this study is to identify toxicants causing acute toxicity in effluents from the aluminum rolling industry that violate the discharge limits in Korea. Methods: Whole effluent toxicity tests (WET) were conducted on effluent discharged from the aluminum rolling industry following the US EPA WET test methods. We collected effluent samples three times and evaluated acute toxicity by using Daphnia magna. We employed toxicity identification evaluation (TIE) procedures to identify toxicants causing toxicity in the effluent. Results: No specific chemical groups were identified in the seven different manipulations applied to the of wastewater effluent samples showing 1.3 toxic units (TU) according to the TIE phase I procedures. Water quality parameters for water hardness, electric conductivity and heavy metals (Mn) were 4,322 mg/l as $CaCO_3$, 11.39 mS/cm, and $5,551{\mu}g/l$, respectively. Considering water hardness and reference toxicity, high concentrations of Mn can be disqualified from the causative toxicants. Consequently, high ionic concentrations of $Na^+$(1,648 mg/l), $Ca^{2+}$(1,048 mg/l), $Mg^{2+}$(1,428 mg/l) and $SO_4{^{2-}}$(7,472 mg/l) were identified to be causative toxicants. Water hardness and electric conductivity exceed the $EC_{50}$ value obtained by biological toxicity tests using Daphnia magna. Conclusion: According to TIE procedures, high salt concentration is determined to be a major toxicant in the effluent of agro-industrial wastewater treatment plants receiving wastewater from the aluminum rolling industry.

Seismic deformation demands on rectangular structural walls in frame-wall systems

  • Kazaz, Ilker
    • Earthquakes and Structures
    • /
    • v.10 no.2
    • /
    • pp.329-350
    • /
    • 2016
  • A parametric study was conducted to investigate the seismic deformation demands in terms of drift ratio, plastic base rotation and compression strain on rectangular wall members in frame-wall systems. The wall index defined as ratio of total wall area to the floor plan area was kept as variable in frame-wall models and its relation with the seismic demand at the base of the wall was investigated. The wall indexes of analyzed models are in the range of 0.2-2%. 4, 8 and 12-story frame-wall models were created. The seismic behavior of frame-wall models were calculated using nonlinear time-history analysis and design spectrum matched ground motion set. Analyses results revealed that the increased wall index led to significant reduction in the top and inter-story displacement demands especially for 4-story models. The calculated average inter-story drift decreased from 1.5% to 0.5% for 4-story models. The average drift ratio in 8- and 12-story models has changed from approximately 1.5% to 0.75%. As the wall index increases, the dispersion in the calculated drifts due to ground motion variability decreased considerably. This is mainly due to increase in the lateral stiffness of models that leads their fundamental period of vibration to fall into zone of the response spectra that has smaller dispersion for scaled ground motion data set. When walls were assessed according to plastic rotation limits defined in ASCE/SEI 41, it was seen that the walls in frame-wall systems with low wall index in the range of 0.2-0.6% could seldom survive the design earthquake without major damage. Concrete compressive strains calculated in all frame-wall structures were much higher than the limit allowed for design, ${\varepsilon}_c$=0.0035, so confinement is required at the boundaries. For rectangular walls above the wall index value of 1.0% nearly all walls assure at least life safety (LS) performance criteria. It is proposed that in the design of dual systems where frames and walls are connected by link and transverse beams, the minimum value of wall index should be greater than 0.6%, in order to prevent excessive damage to wall members.

A Study on the Status and Prediction of Arterial Road Noise in Seoul, Korea (서울시 간선도로의 소음도 현황 및 예측식에 관한 고찰)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Hong, Seung-Cheol;Choi, Joon-Gyu
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.5
    • /
    • pp.395-402
    • /
    • 2008
  • Road traffic noise causes considerable disturbance and annoyance in exposed inhabitants. Particularly, arterial road noise is a significant environmental problem in many urban areas in which higher traffic volume and higher car speed occur. Arterial road noise became the target of this investigation in Seoul, South Korea. Noise levels were measured at four points that were based on distance from roadside at the same measurement site and under the conditions as reported by the National Institute of Environmental Research (NIER) in 1999. The average noise levels ($L_{eq,1h}$) of the arterial road was 80.3 dBA at 5 m, 77.4 dBA at 10 m, 73.7 dBA at 20 m, 70.9 dBA at 30 m. A comparison between 1999 and 2008's measurement values has shown that in 2008 noise level is up by about 1.5 dBA, traffic volume has increased by about 15.7%, while car speed has decrease by about 8%. The relationship between 2008' measured values and predicted values using the NIER Equation is low under 10 m from the roadside. The influence range of arterial noise is calculated at 26 m for road noise limits in daytime. In relation to the comparison between traffic volume and noise level, the equivalence in traffic volume (Light car+10xHeavy car) is higher than other variables.