• Title/Summary/Keyword: safety facilities

Search Result 3,112, Processing Time 0.026 seconds

A Study on the Analysis of Disaster Type for School Facilities and the Application Propriety of In-kind Compensation (학교 시설물의 재난유형 분석 및 현물보상 적용에 관한 연구)

  • Lee, Byoung Ho;Oh, Tae Keun;Cho, Sung Woo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.177-185
    • /
    • 2018
  • The school space is a place for learning activities and community activities, and it is used as a shelter for various disasters. Recently, the frequency and magnitude of damages of school facilities due to various disasters are increasing, and similar accidents occur repeatedly every year, causing enormous damage to school classes. Furthermore, damage to school facilities will require considerable time and safety confirmation measures to restore disaster and normalize the class. In this regards, based on the questionnaire survey on the difficulties and improvement measures of the disaster recovery work of the school safety manager, we propose the application of in-kind compensation for damage to school facilities to ensure rapid disaster recovery, simplification of administrative procedures, and quality of restoration work.

A Study on the Actual Situation and Improvement Method of Safety Accidents of Elementary School's Facilities - Focused on Elementary Schools on Chungcheongnamdo - (초등학교 시설의 안전사고 실태 및 개선방안 - 충남지역 초등학교를 중심으로-)

  • Heo, Kyeong;Lee, Jae-Rim
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.2
    • /
    • pp.9-18
    • /
    • 2010
  • The school is the educational and living space for students and teachers. And, the safety of the school facilities is very important element on the school activities. For this safety of school facilities, there is a need to prevent of safety-accident by the reinforcement of the systematic and the removal of risk factors. In order to minimize the damages from school facilities this study tried to suggest the solution for the prevention of safety accidents according to research about actual conditions of safety accidents from school facilities.

Research on serviceability indicators and evaluation method for the revision of Special Act on Safety and maintenance of facilities (시특법 개정을 위한 서비스 성능 지표 설정 및 평가 방법 연구)

  • Park, Taeil;Park, Wonyoung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.312-313
    • /
    • 2018
  • As global climate change leaded to extensive natural disaster and radical deterioration of infrastructures, there was increased attentions for the evaluation of infrastructures. After the collapse of Seongsu Bridge in 1994, Korea has enacted the "Special act on safety and maintenance of facilities" and secured the safety of facilities using systematic and periodic safety inspections. However, current facility inspections are mainly performed by the physical defect and structural analysis, and do not properly consider the serviceability of infrastructure such as capacity of facility and user's satisfaction. Thus, the purpose of the study is to develop an evaluation criteria for serviceability of infrastructures and finally leading to the revision of "Special Act on safety and maintenance of facilities in rational manner.

  • PDF

A Study on the School Safety Accident Prevention Policy through Accident Case Analysis (사고사례 분석을 통한 학교안전사고 예방정책에 관한 연구)

  • Park, Sang-Keun;Yoon, Yong Gi
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.22 no.5
    • /
    • pp.11-22
    • /
    • 2015
  • The purpose of this study is to suggest prevention policy by analyzing accident cases related with school facilities. The results of study are as follows: First, policy enforcement that follows disaster management process such as prevention, preparation, response and recovery is required for school safety policy. Second, in order to proceed with the effective safety policy through collection, analysis, interpretation of data and result monitoring against accident case, the systematic safety infrastructure such as injury surveillance system and the composition of policy consultative group among safety organizations should be established. Third, the school facilities should be installed and managed according to the safety design. Fourth, the systematic education is needed to done for the managers who are concerned with safety regarding the establishment of safety management plan for each school. Fifth, the evaluation and feedback system is required for the results of proceeding with safety policy.

Assessment System of Safety Level of High Voltage Electrical Facilities Considering Environmental Factors (환경영향 요소를 고려한 특고압 전기설비의 안전등급 평가시스템)

  • Kim, Dong-Woo;Lim, Young-Bea;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.249-254
    • /
    • 2017
  • This paper presents an assessment system of safety level of 22.9kV grade high voltage electrical facilities considering environmental factors. The assessment system was developed based on the following procedure. Firstly, assessment structure was determined by consulting standards regarding inspection and diagnosis of electrical facilities. Secondly, contents of items and sub items of assessment system were developed. Thirdly, in order to quantify the importance of the assessment system, the weight was calculated using Analytic Hierarchy Process(AHP). Lastly, assessment table of safety level was developed including environmental factors such as period of use and load factor. The developed system can evaluate the safety level of high voltage facilities in an objective way. Therefore it can be applicable to electrical safety management system based on Internet of Things(IoT).

Study on Improvement of Facility Criteria of Architectural Planning by analysing the State of Safety Accident in Schools - Focused on the Primary Schools in Daejon City - (학교안전사고 실태분석을 통한 건축계획적 시설기준 개선에 관한 연구 -대전지역 초등학교를 중심으로-)

  • Park, Im-Ho;Jung, Jin-Ju
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.2
    • /
    • pp.21-31
    • /
    • 2012
  • This study is with the subjects of 7 primary schools in Daejon City which opened after 2004 when the Ministry of Education & Human Resources Development released the "Study of Developing the Manual for Safety and Plan of school facilities". This is to study the measures of improving or enhancing the safety criteria on the school facilities from the viewpoint of actual planning as well as of architectural planning through investigating and analysing the cause, the status and the type of negligent accidents by school which are occurring both directly and indirectly. Though the analysis of the examined contents shows there is no facility in primary schools not satisfying 'the criteria on safety maintenance of school facilities', the criteria is so comprehensive and general that its content is just itemized and the current criteria of facilities are not fit for the present situation because of the physical condition of the students in elementary, middle and high schools and the changing curriculum.

Foodservice Management and Food Safety Knowledge and Practices of Employees in Elderly Welfare Facilities (50인 미만 노인복지시설의 급식 현황 및 급식업무 종사자들의 위생지식 및 실천도 평가)

  • Seo, Sunhee;Yun, Nara
    • Journal of the Korean Dietetic Association
    • /
    • v.17 no.3
    • /
    • pp.287-301
    • /
    • 2011
  • This study examined the current status of foodservice management in elderly welfare facilities and evaluated food service workers' food safety practices and knowledge. For this, the directors of 20 elderly welfare facilities (each with fewer than 50 residents) located in Seoul were interviewed and a survey of 40 foodservice workers was conducted to determine their food safety knowledge and practices. The facilities accommodated an average of 28 residents. All the facilities were self-operated and approximately 62% were dependent on payments by residents. Only 15% had a dietitian in charge of menu planning, food purchasing, and food safety management. Approximately 50% had their facility managers take responsibilities for menu planning and food safety management. Most of the facilities provided food safety training within their own facility and sanitized their utensils, cutting boards, and dishcloths on a daily basis. A limited number of foodservice workers, insufficient training programs, and budget constraints were some of the major barriers to food safety management. Their average score on food safety practices was 1.62, and that on food safety knowledge was 17.6 out of 19 points. These results indicate that the foodservice workers had good food safety knowledge and appropriate food safety practices. There was a significant correlation only between food safety practices related to receiving and storing food products and knowledge of personal hygiene.

Development on the Safety Management System of Hazardous Chemicals under the Chemicals Control Act: Focusing on Safety Assessment System (화학물질관리법상의 유해화학물질 안전관리 개선방안 연구 : 안전성평가 사례 중심)

  • Yoo, Byungtae;Lee, Eun Byul;Kim, Jong Gu
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.96-101
    • /
    • 2019
  • Chemicals Control Act have been strengthened to control more safely hazardous chemicals from 2015. In particular, the standards for the installation and management of handling facilities was enhanced with specific regulations depending on type of the facilities and the hazardous chemicals. However, some standards for handling facilities caused difficulties in implementing the strengthened standards due to various field conditions, such as lack of physical space. The Ministry of Environment is implementing Safety Assessment System (SAS) to solve these problems since 2018. However, many plants have difficulties in preparing alternative methods to pass the safety evaluation. The purpose of this study was to review and analyze the SAS and to suggest alternative measures in terms of management and technical aspects through the case study of hydrochloric acid storage tanks. The following safety solutions were suggested for handling facilities that had insufficient the space and capacity for the retaining wall due to physical space. Firstly, insufficient space was resolved by introducing equipment relocation or demolition, and retaining wall expansion. Secondly, the wall of the surrounding buildings was used as an alternative to the retaining wall with additional chemical resistant treatment. Finally, sensor installation and facility inspection were suggested as ways to improve chemical safety. Therefore, improvement of chemical accident prevention system is required not only in terms of facilities supplementation but also management aspect. The results of this study are expected to be available for similar facilities and will be based on the preparation of additional safety assessment as alternatives measures in the future.

An investigation on the actual condition of electrical facilities in domestic fountains (분수대 전기설비의 국내 적용실태분석)

  • Kim, H.S.;Kim, C.M.;Hwang, K.S.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11c
    • /
    • pp.44-46
    • /
    • 2005
  • An Electrical facilities of fountain is one of the vulnerable facilities because it is exposed to water. Especially, some children enter the fountain and play in the water in the hot season. For example, death from electrical shock in fountain was reported in domestic and foreign papers. In this paper, we analyzed the riskiness of electrical shock on the basis of a fact-finding survey and comparing the domestic and international standard of electrical facilities in fountains.

  • PDF

Wind-Resistant Safety Reviews of Cable-Stayed Bridge by Wind Tunnel Tests (풍동실험을 통한 사장교의 내풍 안전성 검토)

  • Huh, Taik-Nyung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.637-644
    • /
    • 2020
  • Because suicide accidents sometimes were happened in grand bridges over rivers or sea water recently, it will be necessary that prevention measures be made preparation in advance from now on. Additional safety facilities must be needed in addition to existing safety facilities in such a way as this prevention measure. In order to make cable-stayed bridge safe on wind for additional safety facilities, main girder models with added safety facilities for wind-tunnel tests was made, and wind tunnel experiments was carried out to measure aerodynamic force coefficients. Also, wind-resistant analyses of 3D cable-stayed bridge were performed on the basis of wind-tunnel test results. From the wind experiments, force coefficients of main girder with added safety facilities were assessed, and it is known that there are little possibility of galloping and rotation of steel main girder. Finally, from the wind resistant analyses, it was concluded that wind-resistant safety of cable-stayed bridge was secured on wind speed 60.6m/sec.