• Title/Summary/Keyword: safety equipment

Search Result 2,915, Processing Time 0.032 seconds

Monitoring of Pesticide Residues on Dried Agricultural Products (건조채소류의 잔류농약 실태 조사)

  • Gang, Gyungri;Mun, Sujin;Kim, Gwang-Gon;Yang, Yongshik;Lee, Semi;Choi, Euna;Ha, Dongryong;Kim, Eunsun;Cho, Baesik
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.49-61
    • /
    • 2017
  • The study was conducted for safety evaluation of 208 kinds of residue pesticides on 200 dried agricultural products, which are distributed in Gwangju. The method of monitoring was the second of Multi Class Pesticide Multi-residue Methods in Korean Food Code, and GC-ECD, GC-NPD, GC-MSD, and LC-MS/MS were used as evaluation equipment to analyze. The residue level in pesticides were 15.5% (31 of 200 samples) and 4 samples exceeded MRLs. 4.5 mg/kg of pyraclostrobin (MRL; 3.0 mg/kg) was detected in red pepper, 1.49 mg/kg of chlorpyrifos (MRL; 0.13 mg/kg) in daikon leaves, 38.26 mg/kg of pyridalyl (MRL; 0.25 mg/kg) in pepper leaves, 0.98 mg/kg of chlorpyrifos (MRL; 0.05 mg/kg), respectively. Pesticides were found on the 15 samples among the 21 samples of red pepper which is a fruit vegetable, and this resulted in high detection rate of 71%. In addition, pesticides were detected on chwinamul, shitake, siler divaricata, daikon leaves and others within MRLs. The frequent detected kinds of pesticides were insecticide (47.6%), fungicide (33.3%), acaricide (14.3%), nematicide (4.8%) in the order named, and pesticides were methoxyfenozide > pyraclostrobin > azoxystrobin, chlorantraniprole > novaluron, trifloxystrobin in frequent order.

The research for the yachting development of Korean Marina operation plans (요트 발전을 위한 한국형 마리나 운영방안에 관한 연구)

  • Jeong Jong-Seok;Hugh Ihl
    • Journal of Navigation and Port Research
    • /
    • v.28 no.10 s.96
    • /
    • pp.899-908
    • /
    • 2004
  • The rise of income and introduction of 5 day a week working system give korean people opportunities to enjoy their leisure time. And many korean people have much interest in oceanic sports such as yachting and also oceanic leisure equipments. With the popularization and development of the equipments, the scope of oceanic activities has been expanding in Korea just as in the advanced oceanic countries. However, The current conditions for the sports in Korea are not advanced and even worse than underdeveloped countries. In order to develop the underdeveloped resources of Korean marina, we need to customize the marina models of advanced nations to serve the specific needs and circumstances of Korea As such we have carried out a comparative analysis of how Austrailia, Newzealand, Singapore, japan and Malaysia operate their marina, reaching the following conclusions. Firstly, in marina operations, in order to protect personal property rights and to preserve the environment, we must operate membership and non-membership, profit and non-profit schemes separately, yet without regulating the dress code entering or leaving the club house. Secondly, in order to accumulate greater value added, new sporting events should be hosted each year. There is also the need for an active use of volunteers, the generation of greater interest in yacht tourism, and the simplification of CIQ procedures for foreign yachts as well as the provision of language services. Thirdly, a permanent yacht school should be established, and classes should be taught by qualified instructors. Beginners, intermediary, and advanced learner classes should be managed separately with special emphasis on the dinghy yacht program for children. Fourthly, arrival and departure at the moorings must be regulated autonomically, and there must be systematic measures for the marina to be able, in part, to compensate for loss and damages to equipment, security and surveillance after usage fees have been paid for. Fifthly, marine safety personnel must be formed in accordance with Korea's current circumstances from civilian organizations in order to be used actively in benchmarking, rescue operations, and oceanic searches at times of disaster at sea.

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Study on Implementation Measures of Provincial Self-governing Police System : Focusing on the Implication from Enlargement of Work Scope of Self-governing Police of Jeju Province (광역자치경찰제의 정착방안에 관한 연구 - 제주자치경찰의 사무확대에 대한 시사점을 중심으로 -)

  • Kim, Seong-Hee
    • Korean Security Journal
    • /
    • no.59
    • /
    • pp.37-69
    • /
    • 2019
  • According to viewpoints of researchers and stakeholders, various opinions can be suggested on self-governing police system. Therefore, success of Korean self-governing police system will be defending on how to balance among conflicting values such as Empowerment, Political neutrality, Financial issues, Comprehensive competence in maintaining public safety. Before the launching of self-governing police system nation-wide, the experience of Jeju provincial police will be valuable model case. In specific, enlargement of work scope of self-governing police in Jeju province which has been introduced since last year will be a useful reference. There is more pessimism about self-governing police of Jeju province so far. However, this perspective is mostly based on the issue regarding hardwares such as manpower, equipment, law and organization. Issues regarding softwares such as organizational culture, operation system and work process need more attention to evaluate self-governing police system properly. To mark the first year after enlargement of work scope of Jeju police, this study demonstrate the overall result and implications of self-governing police of Jeju province based on documents, statistics, reports and media reports. In result, several preconditions are needed to implement the self-governing police system nation-wide successfully. 1. Strengthen the link between local government and local police 2. Establish the foundation for collaboration of state and local police 3. Enhance the aspect of citizen autonomy in local level 4. Reinforcing the capability of handling situation of state and local police 5. Invigorating the inter-organizational working group to operate self-governing police system effectively. The self-governing police system is unclosed topic to discuss. After this study, in-depth studies should be followed with more resources. Particularly, additional perspective including redundancy and equity need to be considered regarding self-governing police. By getting with the changes of macroscopic trends - lowbirth and aging, the fourth industrial revolution and possible reunification of north and south Koreas - these studies should suggest the long-term blueprint of self-governing police system of Korea.

Relationship between Compressive Strength and Dynamic Modulus of Elasticity in the Cement Based Solid Product for Consolidating Disposal of Medium-Low Level Radioactive Waste (중·저준위 방사성 폐기물 처리용 시멘트 고화체의 압축강도와 동탄성계수의 관계)

  • Kim, Jin-Man;Jeong, Ji-Yong;Choi, Ji-Ho;Shin, Sang-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.321-329
    • /
    • 2013
  • Recently, the medium-low level radioactive waste from nuclear power plant must be transported from temporary storage to the final repository. Medium-low level radioactive waste, which is composed mainly of the liquid ion exchange resin, has been consolidated with cementitious material in the plastic or iron container. Since cementitious material is brittle, it would generate cracks by impact load during transportation, signifying leakage of radioactive ray. In order to design the safety transporting equipment, there is a need to check the compressive strength of the current waste. However, because it is impossible to measure strength by direct method due to leakage of radioactive ray, we will estimate the strength indirectly by the dynamic modulus of elasticity. Therefore, it must be identified the relationship between of strength and dynamic modulus of elasticity. According to the waste acceptance criteria, the compressive strength of cement based solid is defined as more than 3.44 MPa (500 psi). Compressive strength of the present solid is likely to be significantly higher than this baseline because of continuous hydration of cement during long period. On this background, we have tried to produce the specimens of the 28 day's compressive strength of 3 to 30 MPa having the same material composition as the solid product for the medium-low level radioactive waste, and analyze the relationship between the strength and the dynamic modulus of elasticity. By controling the addition rates of AE agent, we made the mixture containing the ion exchange resin and showing the target compressive strength (3~30 MPa). The dynamic modulus of elasticity of this mixtures is 4.1~10.2 GPa, about 20 GPa lower in the equivalent compressive strength level than that of ordinary concrete, and increasing the discrepancy according to increase strength. The compressive strength and the dynamic modulus of elasticity show the liner relationship.

The Liability of Participants in Commercial Space Ventures and Space Insurance (상업우주사업(商業宇宙事業) 참가기업(參加企業)의 책임(責任)과 우주보험(宇宙保險))

  • Lee, Kang-Bin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.5
    • /
    • pp.101-118
    • /
    • 1993
  • Generally there is no law and liability system which applies particulary to commercial space ventures. There are several international treaties and national statutes which deal with space ventures, but their impact on the liability of commercial space ventures has not been significant. Every state law in the United States will impose both tort and contract liability on those responsible for injuries or losses caused by defective products or by services performed negligently. As with the providers of other products and services, those who participate in commercial space ventures have exposure to liability in both tort and contract which is limited to the extent of the resulting damage The manufacturer of a small and cheap component which caused a satellite to fail to reach orbit or to operate nominally has the same exposure to liability as the provider of launch vehicle or the manufacturer of satellite into which the component was incorporaded. Considering the enormity of losses which may result from launch failure or satellite failure, those participated in commercial space ventures will do their best to limit their exposure to liability by contract to the extent permitted by law. In most states of the United States, contracts which limit or disclaim the liability are enforceable with respect to claims for losses or damage to property if they are drafted in compliance with the requirements of the applicable law. In California an attempt to disclaim the liability for one's own negligence will be enforceable only if the contract states explicitly that the parties intend to have the disclaimer apply to negligence claims. Most state laws of the United States will refuse to enforce contracts which attempt to disclaim the liability for gross negligence on public policy grounds. However, the public policy which favoured disclaiming the liability as to gross negligence for providers of launch services was pronounced by the United States Congress in the 1988 Amendments to the 1984 Commercial Space Launch Act. To extend the disclaimer of liability to remote purchasers, the contract of resale should state expressly that the disclaimer applies for the benefit of all contractors and subcontractors who participated in producing the product. This situation may occur when the purchaser of a satellite which has failed to reach orbit has not contracted directly with the provider of launch services. Contracts for launch services usually contain cross-waiver of liability clauses by which each participant in the launch agrees to be responsible for it's own loss and to waive any claims which it may have against other participants. The crosswaiver of liability clause may apply to the participants in the launch who are parties to the launch services agreement, but not apply to their subcontractors. The role of insurance in responding to many risks has been critical in assisting commercial space ventures grow. Today traditional property and liability insurance, such as pre-launch, launch and in-orbit insurance and third party liability insurance, have become mandatory parts of most space projects. The manufacture and pre-launch insurance covers direct physical loss or damage to the satellite, its apogee kick moter and including its related launch equipment from commencement of loading operations at the manufacture's plant until lift off. The launch and early orbit insurance covers the satellite for physical loss or damage from attachment of risk through to commissioning and for some period of initial operation between 180 days and 12 months after launch. The in-orbit insurance covers physical loss of or damage to the satellite occuring during or caused by an event during the policy period. The third party liability insurance covers the satellite owner' s liability exposure at the launch site and liability arising out of the launch and operation in orbit. In conclusion, the liability in commercial space ventures extends to any organization which participates in providing products and services used in the venture. Accordingly, it is essential for any organization participating in commercial space ventures to contractually disclaim its liability to the extent permitted by law. To achieve the effective disclaimers, it is necessary to determine the applicable law and to understand the requirements of the law which will govern the terms of the contract. A great deal of funds have been used in R&D for commercial space ventures to increase reliability, safety and success. However, the historical reliability of launches and success for commercial space ventures have proved to be slightly lower than we would have wished for. Space insurance has played an important role in reducing the high risks present in commercial space ventures.

  • PDF

Development of a Mobile Tower-yarder with Tractor (I) - Design and Manufacture - (트랙터부착형 타워집재기 개발(I) - 설계 및 제작-)

  • Park, Sang-Jun;Kim, Bo-Kyun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.61-70
    • /
    • 2008
  • This study was conducted to develop a mobile tower-yarder with tractor for agriculture and forestry that is the efficient yarder in steep terrains, thinning operation and small scale logging operation. It was designed and manufactured that the power source of tower-yarder is equiped three hydraulic pump connected to PTO of tractor, and three hydraulic pump is used to operate the four motor for drum, the cylinder for clutch of interlocker, the cylinder for tower expanding and the out-rigger cylinder. It was to adopt the running skyline system and the inter-lock function, and to equip the double capstan drum, the storage drum and the clutch for interlock in the development of tower-yarder. It was to develop the tower-yarder which the winch torque of double-capstan drum, the traction force of double-capstan drum, the number of rotation of double-capstan drum and the line speed is $191kg{\cdot}m$, 1,910 kgf, 220.5 rpm and 138.5 m/min, respectively. And it was known that the optimum flange diameter of the main and haulback storage drum is about 360 mm and about 460 mm in order to storage the main line length of 250m and the haulback line length of 450 m. The carriage was made to adopt the running skyline system and to equip the lock function in order to the convenience of chocking and the fall down preventing of tree. It was provided to develop the wire remote controller for the inter-lock function, the convenience of control and the efficiency of yarding. In development process, this tower-yarder was attached the 3-point linkage hitch equipment and the tire wheel for the traction and moving of tower-yarder. Also, it was equipped that the out-rigger and the guy line in order to raise the safety and efficiency of yarding of tower-yarder.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

The Improvement Plan on Unifying from Law and Regulations Related to Radiation (방사선관계법 개정 시 용어 적용에 관한 개선 방안)

  • Jeong, Dong-Kyong;Lee, Jong-Back;Park, Myeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Purpose: This is for the purpose to help the bill related to technologists be systematic and unitary by carefully analyzing a legislation, an enforcement ordinance, and enforcement regulations in the connection with the radiological worker and the radiation workers from the law and regulations related to technologists. Materials and Methods: Concerning technologists, a legislation, an enforcement ordinance, and enforcement regulations for a sort of medical technician, regarding the radiological worker, the rules of diagnosis radiation equipment safety management, and concerning the radiation workers, atomic energy law, an enforcement ordinance and enforcement regulations were gathered, compared with one another, and analyzed. Results: Among technologists, in the case of working in the department of diagnosis radiation, the title 'Radiological Worker' is used by the Medical Service Law, and in the case of working in the department of radiation tumors or the one of nucleus medicine, the title 'Radiation Workers' is used by the Atomic Energy Law. Conclusion: Besides the technical term that is used by characteristic tasks, unification of the terms that can be used in common is necessary for sure. And when a legislation, an enforcement ordinance, enforcement regulations, and notification, things like that in the radiation field are amended, certainly they should be done by mutual agreement through negotiation between the organization related to radiation and the governmental organization.

  • PDF

The Study on the Protection and Actual Condition of Using the Dental X-ray Unit (치과진단용 X선발생장치의 이용 실태 및 방어에 관한 연구)

  • Kang, Eun-Ju;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.43-54
    • /
    • 2000
  • This paper will present the result of research which was done with 201 places on the actual condition of using dental diagnostic radiography unit and the protection of radiography. The purpose of this paper is to comprehend the actual condition of using dental x-ray unit and to protect when they do radiation work. Moreover this paper was completed to prepare basic materials that could be helpful to reduce the exposure from radiation. This paper obtains the following result. 1. On radiation photographing work in the dentist office, 50.3% of dental hygienists treat this job, and 19.2% of assistants, 10.8% of dentists, 5.6% of radiolotechnologists and 4.2% others performed this job. 2. The case that radiation worker is educated about diagnostic radiography safety supervision has been shown 14.4% and uneducated case has been shown 78.1%. 3. The result about the actual condition of using the oral diagnostic radiation per day was that a number of film which take photograph again (less than 1 exposure) was 40.3%. Normal photographing($1{\sim}10$ exposure) was 85.1% which is the highest percentage. Using the bitewing film and occlusal film was 7.0%, and 12.4% respectively. The percent that they use cephalo film and panoramic film was 16.4% 29.8% respectively. 4. Dental intra diagnostic radiography unit made in $1996{\sim}2000$ was 24.9% and the one made in $1991{\sim}1995$ was 19.9%, in $1986{\sim}1990$ was 19.9%, in 1985 was 9.5% according to the answer. On kVp, they use 60 kVp mostly(61.7%) and On mA, they use 10 mA with the highest percent(66.7%). On the dental extra diagnostic radiography units which are used for doing the extra oral radiography, the one made in $1996{\sim}2000$ was 13.4%, in $1991{\sim}1995$ was 9.5%, in $1985{\sim}1990$ was 2.0% according to the answer. They use $71{\sim}80\;kVp$ with 10.9% and $60{\sim}75\;kVP$ with 9.5%. They use less than 10 mA with 19.4% and $11{\sim}15\;mA$ with 2.5%. $16{\sim}20\;mA$ with 1.5%. But the case they exactly do not know how much mA they use or they do not have any mA was 76.6%. 5. General characteristics and the part of protection through the protective equipment by operator are completed with 89.1%. They have shown the similar difference in the relationship with age(p<0.001), experience(p<0.05) and in-patient(p<0.05). 6. When they take photographs of radiation with general quality, how far they keep the proper distance from the cone is as follows, Keeping safe distance is 12.9% according to the answer with the low percent. This result is similar with the difference related in experience(p<0.05) and work(p<0.05), the area of working(p<0.05) and in-patient(p<0.05). 7. The answer about the question-if they hold the tube head when they take photographs with general characteristics is as follows. The answer that they never hold the tube head and cone occupies 62.7% with the highest percent. It is shown the similar difference with age(p<0.05). 8. According to the study that they put on dosimeter with general characteristics is as follows. 64.7% has never put on the dosimester with the highest percent. 33.8% showed similar differences with experience(p<0.05), work(p<0.001), the area of work(p<0.005)and in-patient(p<0.001).

  • PDF