• Title/Summary/Keyword: safety Inspection

Search Result 2,003, Processing Time 0.028 seconds

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

Assessment of Degree and Safety Inspection Based on Maintenance Level in Domestic Youth Training Facility (국내 청소년시설 대상 유지관리기반 안전점검 및 안전성 평가 연구)

  • Lee, Jeong-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2020
  • Recent the number, size and accident on Youth Training Facility have increased annually. Also, the discussion and interest relation to safety and maintenance of youth culture and education. This study asserts the necessity and importance of present condition and characteristic based on Youth Training Facility in domestic. Therefore, Results of this study, it is appeared that very vulnerable to improve safety and maintenance in them. Accordingly, The purpose of this study is to investigate the current status for the whole youth facilities. second it estimate on main damage and defect of them for the period four years.

The Optimal Design Rectifying Inspection Plan with Application to Linear Cost Model (선형비용모델을 이용한 계수선별형 검사방식의 최적설계)

  • Cho, Jai-Rip
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.4
    • /
    • pp.74-89
    • /
    • 1995
  • In recent years, the safety of customers and the demand for rights to be protected from the risk have become stronger than ever day by day, and the function concerning product liability(PL) and quality assurance(QA) has been emphasized. Basically these functions can be obtained by inspection and there is the single rectifying sampling inspection for attribute (KSA-3105) as an existing method. But we can not say this method is good enough because of limitations in the range of applications and the approximate design of inspection methods which can not meet the rapidity and accuracy of quality information transfer according to the maturity of information period. Therefore, in this paper, a new algorithm is developed which can design the accurate inspection method by using the linear cost function that has not been considered in the existing inspection methods. Also in addition to this, a optimal rectifying sampling inspection plan, contributing to minimize the total costs, can be developed by programming the algorithm developed in this study and it can be applied to any field having many processes almost limitlessly.

  • PDF

Study on Levee Visual Inspection Information System Building Using Mobile Technology

  • Kang, Seung-Hyun;Lee, Jong-Min
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.6
    • /
    • pp.71-76
    • /
    • 2016
  • In this paper, we propose the mobile visual inspection information system using DGPS and portable range finder for levee safety inspection. Instead of existing visual inspection management method that is stored hand-written data, this system is designed to manage directly the visual inspection information using mobile devices in the field of levee. And through extracting accurate DGPS coordinates information about damage location of levee, this system is developed to ensure efficiency for the main task arising from the levee site such as inspection, maintenance and reinforcement. Furthermore, when damage has occurred at the point that inspector is not able to approach, this system can record the damage site data correctly, by converting data such as position, orientation and height of the damage point into the World Geodetic System coordinates. The position, orientation and height data was extracted automatically through the DGPS and portable range finder. And by applying the augmented reality method, this system was implemented for inspector to revisit the point of damage easily in order to perform the management, maintenance and reinforcement of the levee later.

Preliminary Monitoring of Mycotoxins for Safety Management of Medicinal Herbs (한약재 안전관리를 위한 곰팡이독소 선제적 모니터링 연구)

  • Lee, Hyun-Kyung;Kim, Ae-Kyeong;Kim, Ouk-Hee;Kim, Sung-Dan;Lee, Young-Ju;Lee, Sea-Ram;Kim, Il-Young;Lee, Jung-Mi;Yu, In-Sil;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.3
    • /
    • pp.187-192
    • /
    • 2017
  • The consumption of herbal medicines has been increasing with growing interest in health. However, due to recent climate change and the complex distribution process of herbal medicines with high import dependence the likelihood of contamination with mycotoxin has been increased. Mycotoxins are emerging as key indicators for ensuring safety of herbal medicines. A total of 498 herbal medicine samples were screened for mycotoxin contamination in this study. Aflatoxin in the herbal medicine samples was extracted by using immunoaffinity column, then the extracted aflatoxin was quantified via high performance liquid chromatography coupled with fluorescence detection (HPLC-FLD) method. The extraction method was verified by linearity, recovery, LOD and LOQ. Aflatoxins were detected in 39/498 samples in an average of $7.670{\mu}g/kg$ ($0.610-77.452{\mu}g/kg$ range). Although safety standards for Corydalis Tuber is not currently available in korea, five of the 39 samples had high concentration of aflatoxins (average of $14.9{\pm}4.1{\mu}g/kg$). In conclusion, it is urgent to establish safety criteria of aflatoxin in Corydalis Tuber. The results of the current study suggest that continuous monitoring is necessary for proactive management of herbal medicine safety.

GIS application study in structure safety inspection (구조물 안전진단에서의 GIS 활용방안 연구)

  • Song, Seok-Jin;Kim, Na-Young;Kang, In-Joon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.265-268
    • /
    • 2007
  • Structure safety inspection is executing periodically to apply with maintenance data of the structure. Because of the location of structure is appearing by measuring point and picture in the subway. It is difficult to track the accurate location of the inspected structure. Purpose of this paper is computerizing location and attribute of construction and searching efficiency by GIS.

  • PDF

A development on the inspection technologies for secondary electrical facilities in nuclear power plant (원전 2차측 전력설비 검사기술 개발)

  • Park, Hyun-Shin;Kim, Kern-Joong;Kim, Moon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.110-112
    • /
    • 2005
  • Recently, the reactor trip in nuclear power plants has mostly occurred by the failure of secondary electrical facilities. Some kinds of technical standards or acceptable criteria are required to regulate those facilities. Therefore, in this paper the failures of secondary electrical facilities which cause reactor trip are analyzed, and the inspection technologies including guidelines for secondary electrical facilities are developed.

  • PDF

The Design of Control Chart Based on a Short-run Production Process (단속공정 품질관리도 설계)

  • 김종걸;정연승
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2000.11a
    • /
    • pp.217-234
    • /
    • 2000
  • Approximately normalized control charts, called Q charts, have been given Quesenberry(1991) for charting in process of short-run, job-shop, etc. We consider a Q chart with inspection error for job-shop floor under geometric distribution, which can be used for processes when a fraction nonconforming is very small. Our results would be applied for designing other control charts with inspection error.

  • PDF

가속 수명시험을 이용한 벌크샘플링 설계에 관한 연구

  • Park, Uk-Je;Kim, Jong-Geol
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.255-267
    • /
    • 2006
  • 제품을 로트(lot)단위로 구분하고 로트에서 취한 샘플을 검사하여 얻은 품질 특성의 값을 이용해서 로트의 합격여부를 판정하는 것을 샘플링검사(sampling inspection)라 하고, 검사하는 품질특성이 제품의 수명 특성치인 경우에 이를 신뢰성 샘플링 검사(reliability sampling inspection)라 한다. 그 중 벌크재료에 대한 샘플링 검사방식을 알아 보도록한다.

  • PDF