• Title/Summary/Keyword: safety Inspection

Search Result 1,994, Processing Time 0.034 seconds

Analysis of Remote Electrical Facilities Safety Checkup for General Use (일반용 전기설비 수용가의 원격전기안전점검 모델 설계 및 요소기술 분석)

  • Yoo, Jae-Geun;Choi, Myeong-Il;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2214-2215
    • /
    • 2008
  • KESCO performed periodical inspection every 1${\sim}$3 years to check the status of maintenance and performance of electric installations for general use (less than 600V in voltage and 75kW in capacity in residential homes) but recently a resident have been avoiding periodical check due to increase of sex crime and empty house, which more and more difficult to secure electrical safety of installation. In order to solve non-inspection problems and improve efficiency of inspection, this paper introduce the model of remote monitoring system that check electrical facilites for general use and we are developing remote monitoring device for reliability test.

  • PDF

Analysis of Ammunition Inspection Record Data and Development of Ammunition Condition Code Classification Model (탄약검사기록 데이터 분석 및 탄약상태기호 분류 모델 개발)

  • Young-Jin Jung;Ji-Soo Hong;Sol-Ip Kim;Sung-Woo Kang
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.23-31
    • /
    • 2024
  • In the military, ammunition and explosives stored and managed can cause serious damage if mishandled, thus securing safety through the utilization of ammunition reliability data is necessary. In this study, exploratory data analysis of ammunition inspection records data is conducted to extract reliability information of stored ammunition and to predict the ammunition condition code, which represents the lifespan information of the ammunition. This study consists of three stages: ammunition inspection record data collection and preprocessing, exploratory data analysis, and classification of ammunition condition codes. For the classification of ammunition condition codes, five models based on boosting algorithms are employed (AdaBoost, GBM, XGBoost, LightGBM, CatBoost). The most superior model is selected based on the performance metrics of the model, including Accuracy, Precision, Recall, and F1-score. The ammunition in this study was primarily produced from the 1980s to the 1990s, with a trend of increased inspection volume in the early stages of production and around 30 years after production. Pre-issue inspections (PII) were predominantly conducted, and there was a tendency for the grade of ammunition condition codes to decrease as the storage period increased. The classification of ammunition condition codes showed that the CatBoost model exhibited the most superior performance, with an Accuracy of 93% and an F1-score of 93%. This study emphasizes the safety and reliability of ammunition and proposes a model for classifying ammunition condition codes by analyzing ammunition inspection record data. This model can serve as a tool to assist ammunition inspectors and is expected to enhance not only the safety of ammunition but also the efficiency of ammunition storage management.

Tunnel Safety Diagnosis in Near-excavation by In-depth Inspection of Tunnel (기존터널 안전진단 결과를 통한 근접시공 시 터널 안정성 평가)

  • Kim, Seok-Jae;Kim, Min-Seok;Kim, Jun-Chul;Yoo, Young-Il;Oh, Joung-Bae;Oh, Sae-Joon
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.347-356
    • /
    • 2006
  • We analyzed case studies doing in-depth inspection of tunnel to maintain safety of existing tunnel in constructing new tunnel near to a existing tunnel with single track. Futhermore, We accomplished in-depth inspection of existing tunnel and numerical analysis. We suggested remedies to security safety of existing tunnel. We applied line drilling and pre-large hole boring method not to have an effect on existing tunnel and convinced the safety of existing tunnel from blast-vibration and blast-noise of numerical analysis. We planed to install basset system to measure displacement of existing tunnel according to excavating new tunnel.

Study on the reform case about a bad connection of M.Tr 87Ry 2nd CT circuit etc. (M.Tr 87Ry 2nd CT 회로 오결선 등 개선사례 분석)

  • Park, Kang-Seo;Park, Jun-Sung;Choi, Jong-Soo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.374-378
    • /
    • 2008
  • The analysis about cases which does not correspond in electric equipment technical standard and judgement standard while doing pre inspection, it improves the technical specifications and the draft of construction plan. The analysis of the reform cases prevents the electric disaster and propagates the electrical safety. Hereafter the reform cases will improve the electric technical ability and help the electrical safety of the yard.

  • PDF

A Study on the Safety Management and Activation of Construction Remodeling (건축물 리모델링의 활성화 및 안전관리방안에 관한 연구)

  • Yang, Keek-Young;Kim, Chun-Hag
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.233-244
    • /
    • 2002
  • The purposes of this research are to use the buildings efficiently and long, save energies, make the cozy and comfortable environment of residential and living spaces, rearrange the related acts for easy implementation of remodeling, and activate the government's support programs so as to make remodeling activated in a safe mode. The scope and methodology of this research include the review of existing literatures and data on remodeling, census on apartment residents, influence factors, and the development of methods for activation of building remodeling and strengthening of safety management, like activation measures, licensing and ordering regulation updates, etc regarding the remodeling. Safety inspection and in-depth inspection before and after remodeling should be regulated. The construction materials for remodeling should be light weighted and the construction methods which can minimize the impact and vibration during construction should be selected. The improvement of regulation on the remodeling contractor qualification and order method should be updated. If the remodeling is activated and safety management is reinforced by the suggested measures, solving of lack of house, prevention of abuse of resources, and improvement of residential environment could be accomplished rationally.

Development of RBI Procedures and Implementation of a Software Based on API Code (III) - Quantitative Approach (API 기준에 근거한 RBI 절차 개발 및 소프트웨어의 구현 (III) - 정량적 접근법 -)

  • 송정수;심상훈;최송천;윤기봉
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.56-63
    • /
    • 2003
  • During the last decade, effort has been made f3r reducing maintenance cost for aged equipments and ensuring safety, efficiency and profitability of petrochemical and refinery plants. Hence, it was required to develop advanced methods which meet this need. RBI(Risk Based Inspection) methodology is one of the most promising technology satisfying the requirements in the field of integrity management. In this study, a quantitative assessment algorithm fir RBI based on the API 581 code was reconstructed for developing an RBI software. The user-friendly realRBI software is developed with a module for evaluating quantitative risk md financial risk using the potential consequence and the likelihood. Also, inspection planning module for inspection time and inspection method are included in it.

Development of Risk-Based Inspection(RBI) Technology for LNG Plant Based on API RP581 Code (API RP 581 Code를 기반으로한 LNG 플랜트의 Risk-Based Inspection(RBI) 기술 개발)

  • Choi, Song-Chun;Choi, Jae-Boong;Hawang, In-Ju
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.179-183
    • /
    • 2012
  • As one of promising solutions to overcome high oil price and energy crisis, the construction market of high value-added LNG plants is spotlighted world widely. The purpose of this study is to introduce LNG-RBI system to develop risk assessment technology with RAM(Reliability, Availability, Maintainability) modules against overseas monopolization. After analyzing relevant specific features and their technical levels, risk assessment program, non-destructive reliability evaluation strategy and safety criteria unification class are derived as core technologies. These IT-based convergence technologies can be used for enhancement of LNG plant efficiency, in which the modular parts are related to a system with artificial optimized algorithms as well as diverse databases of facility inspection and diagnosis fields.

A study on the evaluation of tunnel safety through a series of field inspection for ASSM tunnel (재래식 터널 변상 조사 사례 및 안전성 평가에 관한 연구)

  • Park, Si-hyun;Maeng, Doo-young;Lee, Yu-seok;Kim, Young-ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.6 no.2
    • /
    • pp.151-160
    • /
    • 2004
  • This study has carried out a series of field investigation for a ASSM railway tunnel which was constructed several decades ago. It appears that the tunnel lining was cracked in the region of arching structure. Precise inspection is carried out for this region with various non-destructive testing equipments. Based on the inspection results, the cause and the effect of tunnel defects were discussed by conducting the evaluation of tunnel safety with numerical analysis.

  • PDF

The Countermeasure to Explosives on World Cup Stadiums (월드컵 경기장에 대한 폭발물 안전대책)

  • Kim, Myung-Gon
    • Korean Security Journal
    • /
    • no.2
    • /
    • pp.61-81
    • /
    • 1999
  • While the progress of preparation for the 2002 World Cup games goes on the environment is changing by industrializations development of science and specialization of technology, because of that recently the crime has also became intellectual so the importance on countermeasure of safety has raised. The countermeasure for safety The stadium is a limited space where amount of population could be concentrated, so that in a moment there could be a great casualties by terrorism, specially there should be efficient countermeasures for bomb terrorism. So to be prepared for the problems that had been appeared on bomb terrorism activities of North Korea around the world, we should know about the inspection environment and special inspection environment, and for the prevention first of all I've studied on suitable way to inspect the stadiums secondly to plan on specialized training of the necessary personnel on inspection and finally efficiency of use on inspection equipment. With there following plans we could make perfect safety countermeasures focused on prevention for the successful World Cup games.

  • PDF

Concrete Crack Detection Inside Finishing Materials Using Lock-in Thermography (위상 잠금 열화상 기법을 이용한 콘크리트 마감재 내부 균열 검출)

  • Myung-Hun Lee;Ukyong Woo;Hajin Choi;Jong-Chan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.30-38
    • /
    • 2023
  • As the number of old buildings subject to safety inspection increases, the burden on designated institutions and management entities that are responsible for safety management is increasing. Accordingly, when selecting buildings subject to safety inspection, appropriate safety inspection standards and appropriate technology are essential. The current safety inspection standards for old buildings give low scores when it is difficult to confirm damage such as cracks in structural members due to finishing materials. This causes the evaluation results to be underestimated regardless of the actual safety status of the structure, resulting in an increase in the number of aging buildings subject to safety inspection. Accordingly, this study proposed a thermal imaging technique, a non-destructive and non-contact inspection, to detect cracks inside finishing materials. A concrete specimen was produced to observe cracks inside the finishing material using a thermal imaging camera, and thermal image data was measured by exciting a heat source on the concrete surface and cracked area. As a result of the measurement, it was confirmed that it was possible to observe cracks inside the finishing material with a width of 0.3mm, 0.5mm, and 0.7mm, but it was difficult to determine the cracks due to uneven temperature distribution due to surface peeling and peeling of the wallpaper. Accordingly, as a result of performing data analysis by deriving the amplitude and phase difference of the thermal image data, clear crack measurement was possible for 0.5mm and 0.7mm cracks. Based on this study, we hope to increase the efficiency of field application and analysis through the development of technology using big data-based deep learning in the diagnosis of internal crack damage in finishing materials.