• Title/Summary/Keyword: safety D/B

Search Result 627, Processing Time 0.027 seconds

Optimum Design of High Voltage Fuse Holder with a Built-in Acoustic Absorber System (흡음장치를 내장한 고전압 퓨즈홀더의 최적설계에 관한 연구)

  • Jin, Yeung-Jun;Lee, Hae-Won;Hwang, Yu-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.1
    • /
    • pp.8-14
    • /
    • 2011
  • Noise and vibration are likely to disturb the sensory system of human body leading to psychological stress and thereby property damage. In this research, a cut out switch(COS) with a built-in acoustic absorber along with a COS fuse broken was developed to reduce percussion noise. This new system is based on a design approach that combines existing absorber systems: expansion type, resonator type, and acoustic absorber type silencer The noise performance of the new system was simulated using the $SYSNOISE^{TM}$ software under optimized parameters: the diameter of perforated plate 2 mm, the plate thickness 3 mm, the width of expansion room 25 mm, the impinging vortex room 14 mm, and the noise absorbtion room 10 mm. The results showed that it reduced noise by approximately 41.1 dB compared to the current systems available in the market. Furthermore, it showed reduced noise by approximately 12 dB more than a product with an acoustic absorber of the Fault Tamer(USA).

A Study on the Burning Rate of Puzzle Mats (퍼즐매트의 연소속도에 관한 연구)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.84-90
    • /
    • 2008
  • The mass loss rate and heat release rate of puzzle mats were analysed using variable external irradiation level. Five samples of puzzle mat were tested in this study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. Incident heat fluxs of $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $70kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminum foil. Each sample was nominally 20mm thick and 100mm square. The combustion heat and mass loss rate were carried out from Oxygen bomb calorimeter and mass loss calorimeter according to ISO 5660-1 respectively. Heat release rates were calculated using the equation ${\dot{Q}}=A_f{\dot{m}}"_X{\Delta}H_c=0.75A_f{\dot{m}}"{\Delta}H_c$. where $A_f$ is the horizontal burning area of the sample, $\dot{m}"$ is mass loss rate per unit area, ${\Delta}H_c$ is complete heat of combustion and 0.75 is combustion efficiency.

Evaluation of Microstructures and Mechanical Properties in Functionally Graded Materials (STS 316L and Low Alloy Steel) Produced by DED Processes (DED 공정으로 제조된 경사조성재료 (STS 316L과 저합금강)의 미세조직 및 기계적특성 평가)

  • Shin, G.;Choo, W.;Yoon, J.H.;Yang, S.Y.;Kim, J.H.
    • Journal of Powder Materials
    • /
    • v.29 no.4
    • /
    • pp.309-313
    • /
    • 2022
  • In this study, additive manufacturing of a functionally graded material (FGM) as an alternative to joining dissimilar metals is investigated using directed energy deposition (DED). FGM consists of five different layers, which are mixtures of austenitic stainless steel (type 316 L) and low-alloy steel (LAS, ferritic steel) at ratios of 100:0 (A layer), 75:25 (B layer), 50:50 (C layer), 25:75 (D layer), and 0:100 (E layer), respectively, in each deposition layer. The FGM samples are successfully fabricated without cracks or delamination using the DED method, and specimens are characterized using optical and scanning electron microscopy to monitor their microstructures. In layers C and D of the sample, the tensile strength is determined to be very high owing to the formation of ferrite and martensite structures. However, the elongation is high in layers A and B, which contain a large fraction of austenite.

Ultimate strength of long-span buildings with P.E.B (Pre-Engineered Building) system

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.19 no.6
    • /
    • pp.1483-1499
    • /
    • 2015
  • With the improvement of the quality of construction materials and the development of construction technologies, large-scale long-span steel frame buildings have been built recently. The P.E.B system using tapered members is being employed as an economically-efficient long-span structure owing to its advantage of being able to distribute stress appropriately depending on the size of sectional areas of members. However, in December 2005 and in February 2014, P.E.B buildings collapsed due to sudden loads such as snow loads and wind gusts. In this study, the design and construction of the P.E.B system in Korea were analyzed and its structural safety was evaluated using the finite element analysis program to suggest how to improve the P.E.B system in order to promote the efficient and rational application of the system.

A numerical study on the 3-Dimensional shape characteristics of small underground cavities (소규모 지하공동 3차원 형상 특성을 반영한 수치해석에 관한 연구)

  • An, Joon-Sang;Kang, Kyung-Nam;Son, Ki-Il;Kim, Woo-Seok;Kim, Byung-Chan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.5
    • /
    • pp.787-807
    • /
    • 2018
  • When conducting the underground safety impact assessment under the special law in Korea, it is essential to investigate the occurrence of underground cavities. When underground cavities were discovered, the underground safety was assessed through numerical analysis. The previous study has suggested the stability evaluation based on the factor of safety by changing the 2D shape of the small underground cavity. In this study, the effects of small underground cavities considering 3D shapes were examined using a continuum analysis program and compared with the 2D results presented in previous study. If the 3-Dimensional shape of the underground cavity is found close to the sphere type, it would be reasonable to evaluate the factor of safety by the shear strength reduction method regardless of the size and position of the cavity. If a high-aspect ratio underground cavity with a depth of 2 m or more from the ground surface and an aspect ratio (a/b) of 2.0 or more is in the vertical direction, not only the factor of safety but the failure mode shape should be cautions in the stability evaluation using the shear strength reduction method. The results of this study are expected to be basic data on underground safety impact assessment.

Assessment of Noise Exposure and Hearing Loss Among Workers in Textile Mill (Thamine), Myanmar: A Cross-Sectional Study

  • Zaw, Aung K.;Myat, Aung M.;Thandar, Mya;Htun, Ye M.;Aung, Than H.;Tun, Kyaw M.;Han, Zaw M.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.199-206
    • /
    • 2020
  • Background: In a wide range of industries, noise-induced hearing loss remains one of the most prevalent occupational problems. This study aimed to assess the noise exposure level and associated factors of hearing loss among textile workers in Yangon Region, Myanmar. Methods: A cross-sectional study was conducted at a Textile mill (Thamine), Yangon Region, from April to December 2018. In total, 226 workers who were randomly selected from 3 weaving sections participated in face-to-face interviews using a structured questionnaire. A digital sound level meter and pure-tone audiometer were used for the assessment of noise exposure level and hearing loss, respectively. Logistic regression analysis was performed to assess the associated factors of hearing loss. Results: In total workers, 66.4% were exposed to ≥85 dB(A) of noise exposure, and the prevalence of hearing loss was 25.7%. Age ≥35 years, below high school education, hearing difficulty, tinnitus, hypertension, > 9 years of service duration in a textile mill were positively associated with hearing loss. After adjusting confounding factors, age ≥35 years (adjusted odds ratio = 6.90, 95% confidence interval = 3.45-13.82) and tinnitus (adjusted odds ratio = 2.88, 95% confidence interval = 1.13-7.37) were persistently associated with hearing loss. Conclusion: Providing occupational hazard education and enforcement of occupational safety regulations should be taken to decrease the noise exposure level. The regular audiometry test should be conducted for assessment of hearing threshold shift. The employer needs to implement a hearing conservation program in workplace when noise exposure reaches or exceeds 85 dB(A) for 8 hours.

A Case Study on Chloride Corrosion for the End Zone of Concrete Deck Subjected to De-icing Salts Added Calcium Chloride (염화칼슘이 함유된 제설제로 인한 콘크리트 바닥판 단부의 염해에 관한 사례 연구)

  • Chung, Jee-Seung;Kim, Bo-Heon;Kim, Il-Sun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.87-93
    • /
    • 2014
  • In this study, the reinforced concrete rahmen bridge damaged by the chloride attack was investigated. According to the investigation, the degraded concretes on cantilever kerb and end part were intensively observed. Thus, the chloride content test and half-cell method were performed to evaluate the degraded parts. As a result, the contents of chloride on degraded parts were C and D grade. On the other hand, the half-cell potential values of rebar in degraded concrete were measured with the minor corrosion. This rebar corrosion is expected to progressing. Chloride content D grade is due to expansion pressure by corrosion of rebar and freeze-thaw by permeate water, could see progresses rapidly degradation. In order to prevent chloride attack to concrete deck caused by deicing salts, corresponding to the chloride critical concentration must maintain grade b or at least grade c. Chloride condition evaluation standard apply to evaluation of marine structure chloride attack with chloride attack by deicing salts.

A Study on the Risk Assessment Method of Indoor-Impulsive Noise (실내 충격소음 위험 평가 방법에 관한 연구)

  • Chung, Sung Hak;Song, Ki Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.90-97
    • /
    • 2016
  • The objective of this study is to evaluate the operator's safety for the risk assessment method of impulsive noise division. Literature reviews on the basis of the impulsive noise study, the measuring methods and procedures, based on the results of the analysis process presents a risk assessment methods. In this study, analysis of the MIL-STD-1474D, B-duration graph for the peak noise level to cross the line from the measurement results is limited by the risk retracted. It is possible to determine whether there is quick can be determined whether the risk. Measurement positions measured by the microphone is installed on the risk of applying results are so located within the tolerance impulsive noise in the measurement position can interpret subjective safety is ensured. In addition, Proportional Dose technology was the proposed by the Patterson with the risk assessment method was applied to the indoor-impulsive noise. As results of this study, results for the same value of applying the technique of Proportional Dose technology results calculated by MIL-STD-1474D methods allows 1 count once increased in comparison to the result obtained.

An inter-comparison between ENDF/B-VIII.0-NECP-Atlas and ENDF/B-VIII.0-NJOY results for criticality safety benchmarks and benchmarks on the reactivity temperature coefficient

  • Kabach, Ouadie;Chetaine, Abdelouahed;Benchrif, Abdelfettah;Amsil, Hamid
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2445-2453
    • /
    • 2021
  • Since the nuclear data forms a vital component in reactor physics computations, the nuclear community needs processing codes as tools for translating the Evaluated Nuclear Data Files (ENDF) to simulate nuclear-related problems such as an ACE format that is used for MCNP. Errors, inaccuracies or discrepancies in library processing may lead to a calculation that disagrees with the experimentally measured benchmark. This paper provides an overview of the processing and preparation of ENDF/B-VIII.0 incident neutron data with NECP-Atlas and NJOY codes for implementation in the MCNP code. The resulting libraries are statistically inter-compared and tested by conducting benchmark calculations, as the mutualcomparison is a source of strong feedback for further improvements in processing procedures. The database of the benchmark experiments is based on a selection taken from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP handbook) and those proposed by Russell D. Mosteller. In general, there is quite good agreement between the NECP-Atlas1.2 and NJOY21(1.0.0.json) results with no substantial differences, if the correct input parameters are used.

Evaluation of Structural Safety for Hydrogen Tube Trailer Considering Dynamic Property (동적 특성을 고려한 수소 튜브 트레일러의 구조 안전성 평가)

  • Y. B. Kim;M. G. Kim;D. C. Ko
    • Transactions of Materials Processing
    • /
    • v.33 no.3
    • /
    • pp.169-177
    • /
    • 2024
  • Recently, hydrogen energy has been widely used because of strict regulations on greenhouse gas emissions. For using the hydrogen energy, it is required to supply hydrogen through a tube trailer. However hydrogen tube trailer can have excessive load problems during transportation due to reasons such as road shape and driving method, which may lead a risk of hydrogen leakage. So it is necessary to secure a high level of safety. The purpose of this study is to evaluate structural safety for the conservative design of hydrogen tube trailer. First, finite element(FE) modeling of the designed hydrogen tube trailer was performed. After that, safety evaluation method was established through static structural simulation based on the standard GC207 conditions. In addition, effectiveness of the designed model was confirmed through the results of the structural safety evaluation. Finally, driving simulation was used to derive acceleration graph according to time, which was considered as a dynamic property for the evaluation of conservative tube trailer safety evaluation. And dynamic structural simulation was conducted as a condition for actual transportation of tube trailer by applying dynamic properties. As a results, conservative safety was evaluated through dynamic structural simulation and the safety of hydrogen tube trailer was confirmed through satisfaction of the safety rate.