• 제목/요약/키워드: rise on temperature

검색결과 1,480건 처리시간 0.024초

고온초전도선재의 과전류 통전특성 측정 (Measurement of HTS tapes Properties under Over current condition)

  • 이광연;임형우;이희준;차귀수;이지광
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.263-266
    • /
    • 2002
  • Rises of temperature and resistance are observed in HTS tapes under over current condition. In this paper, we measured HTS tapes properties under low-over current condition with a little temperature rise as well as high-over current condition with a large temperature rise. According to the results of measurement, rises of temperature and resistance strongly depend on insulation level and duration of over current condition.

  • PDF

이중외피에서 창문 개폐 및 블라인드 설치에 따른 하절기 실내 열환경 특성 변화 실험 연구 (An Experimental Study on Indoor Thermal Characteristics in accordance with the Use of Windows and Blinds in Double Skin Facade in Summer)

  • 김동균;윤갑천;강재식;김강수
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.59-67
    • /
    • 2011
  • This paper is focused on the effect of indoor temperature rise according to the use of windows and blinds in double skin facade in summer. For the experiment, we set up the mock-up of double skin facede and measuring temperature and solar radiation. Total 7 cases were used for measuring solar transmittance and indoor temperature rise. When the venetian blind was not installed, solar transmittance was 44.5%, and solar transmittance for the case that installed the venetian blind (angle 0) was 22.5%. Cases that opened inner and outdoor windows for ventilation showed lower indoor temperature rise than cases with closed windows. In addition, Case 5 (opened inner and outdoor windows with the venetian blind (angle 0) to reduce solar transmittance) indicated lower indoor temperature rise than Case 3(opened inner and outdoor windows). Consequently, Case 5 which uses inner and outdoor window for ventilation and venetian blind to reduce solar transmittance is the most effective way to reduce indoor temperature rise among all cases tested in this research.

Characterisation of Tensile Deformation through Infrared Imaging Technique

  • B. Venkataraman, Baldev Raj;Mukhophadyay, C.K.
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.609-620
    • /
    • 2002
  • It is well known that during tensile testing, a part of the mechanical work done on the specimen is transformed into heat energy. However, the ultimate temperature rise and the rate of temperature rise is related to the nature of the material, conditions of the test and also to the deformation behaviour of the material during loading. The recent advances in infrared sensors and image/data processing techniques enable observation and quantitative analysis of the heat energy dissipated during such tensile tests. In this study, infrared imaging technique has been used to characterise the tensile deformation in AISI type 316 nuclear grade stainless steel. Apart from identifying the different stages during tensile deformation, the technique provided an accurate full-field temperature image by which the point and time of strain localization could be identified. The technique makes it possible to visualise the region of deformation and failure and also predict the exact region of fracture in advance. The effect of thermal gradients on plastic flow in the case of interrupted straining revealed that the interruption of strain and restraining at a lower strain rate not only delays the growth of the temperature gradient, but the temperature rise per unit strain decreases. The technique is a potential NDE tool that can be used for on-line detection of thermal gradients developed during extrusion and metal forming process which can be used for ensuring uniform distribution of plastic strain.

고농도 오존일의 강우와 운량 (Precipitation and Cloud Cover on High Ozone Days)

  • 김영성;김영진;윤순창
    • 한국대기환경학회지
    • /
    • 제15권6호
    • /
    • pp.747-755
    • /
    • 1999
  • Effects of precipitation and cloud cover on high ozone days are examined by investigating the precipitation and average cloud cover before the ozone peak time within a day. High ozone days above 100 ppb in the Greater Seoul Area(GSA) for the ozone season from May to September are chosen for the analyses in terms of the surface meteorological data during 1990~1997. The result shows that the effect of precipitation on the rise of ozone concentration is definitely negative so that ozone concentration could not rise above 100ppb immediately after precipitation. But, the effect of cloud cover is associated with the variations of other meteorological parameters. The number of high ozone days with "zero" cloud cover is rather less than that with cloud cover of 1 to 4 since temperature is usually lower in "zero" cloud cover days. Furthermore, ozone concentration can rise above 100ppb even with full cloud cover when the wind is weak and the temperature is high.temperature is high.

  • PDF

변압기 절연유의 물성치 변화에 따른 온도특성해석 (Temperature Characteristic Analysis according to Variation of Properties of Transformer Insulating Oil)

  • 김지호;이욱
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.327-332
    • /
    • 2014
  • In this paper, the temperature distribution according to the property change of the insulating oil of the power transformer and max temperature were predicted through the ductility interpretation which heat-flow is coupled. By using CFD (Computation Fluid Dynamics) for the interpretation, the temperature distribution of 154kV the class single phase power transformer was predicted. The power loss causing the temperature rise of the transformer was changed to the heat source and we used as the input value for the heat-flow analysis. The temperature distribution was predicted according to the change of the density, specific heat, thermal conductivity and viscosity, that is the ingredient having an effect on the temperature rise of the transformer oil. The mineral oil of 4 kinds used in domestic and international based on the interpreted result was selected and the temperature distribution according to each load and Hot Spot temperature was predicted.

전력용 변압기의 온도상승 예측을 위한 전자계-열계 결합해석기법 연구 (A Study of Coupled Electromagnetic-Thermal Field Analysis for Temperature Rise Prediction of Power Transformer)

  • 안현모;김민수;송재성;한성진
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1838-1845
    • /
    • 2011
  • This paper deals with coupled electromagnetic-thermal field analysis for thermal fluid analysis of oil immersed power transformer. Electric power losses are calculated from electromagnetic field analysis and are used as input source of thermal field analysis based on computational fluid dynamics(CFD). Particularly, In order to accurately predict the temperature rise in oil immersed power transformer, the thermal problem should be coupled with the electromagnetic problem. Moreover, to reduce analysis region, the heat transfer coefficient is applied to boundary surface of the power transformer model. The coupling method results are compared with the experimental values for verifying the validity of the analysis. The predicted temperature rises show good agreements with the experimental values.

고속 스핀들용 공기 베어링의 열 특성에 관한 연구 (A Study on Thermal Characteristics of Air Bearing System for High-Speed Spindle)

  • 이득우;이종렬;김보언;안지훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1021-1026
    • /
    • 2000
  • The thermal characteristics of high-speed air spindle system with built-in motor are studied. Experiment and finite element method analysis obtain temperature rise and temperature distribution of housing. For the analysis three-dimensional model is built and temperature rise and distribution in thermal steady state are computed for each rotational frequency. Generally. It is said that the heat generation of air bearing is negligible. But it is certain that the heat generation of air bearing can not be negligible especially in high-speed conditions Frequency response test for air spindle system is executed. In case that the heat generation of air spindle system is high, natural frequency of the system becomes lower when it reaches thermal steady-state and it means that the stiffness of air hearing becomes smaller due to the change of bearing clearance. It is shown that the temperature rise of all spindle system causes thermal expansion md induces the variation of hearing clearance. In consequence the st illness of air bearing becomes smaller.

  • PDF

풍력발전기 Air Guide 위치별 온도상승 해석 (Analysis of Temperature Rise on the Air-Guide's Position of Wind Power Generator)

  • 한창우;김현재;권기영;이학성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.282-285
    • /
    • 2008
  • In this paper, the numerical analysis of the model without air-guide was carried out in wind power generator. From numerical results, the temperature rise was not satisfied for the class F insulation and the non-uniformity of temperature distribution was a wide difference in heating elements. To improve these problems, the air-guide was installed in front of the coil head of non-drive end(NDE). The short distance between coil head and air-guide was more effective than long distance in cooling performance. Compared to that of the preliminary design, it was found that the cooling performance of the modification design was improved about 12%.

  • PDF

자계-열계를 결합한 초고압 GIS용 모선의 온도상승 예측 (Prediction of Temperature Rise in EHV GIS Bus Bar by Coupled Magneto-Thermal F.E A)

  • 김중경;민경조;김한균;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.990-992
    • /
    • 2005
  • This paper presents a new magneto-thermal finite element analysis for predicting the temperature rise of the EHV GIS bus bar. The power losses of a bus bar calculated by the magnetic field analysis are used as the input data to predict the temperature rise for the thermal analysis. The heat-transfer coefficients on the boundaries are analytically calculated by applying the Nusselt number considering material constant and model geometry for the natural convection. The temperature distribution in a bus bar by coupled magneto-thermal finite element analysis shows good agreement with the experimental data.

  • PDF

차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구 (A Study on the Development of Standardization Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector)

  • 김시국;육현대;양승현;지승욱;이춘하
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.85-92
    • /
    • 2009
  • 본 논문은 차동식스포트형열감지기 현장점검용 표준화기기 개발에 관한 연구이다. 현재 소방점검 시 차동식스포트형열감지기의 성능확인을 위해 사용되는 점검기기(4 Type)들을 실험대상으로 선정하여 문제점을 찾고, 도출된 문제점을 바탕으로 차동식스포트형열감지기 형식승인 시 감도시험기준과 동일한 온도조건인 실온보다 $30^{\circ}C$ 높은 온도로 자동설정 할 수 있고 설정된 온도를 계속 유지할 수 있는 기능과 풍속 조건인 풍속 85cm/s를 유지할 수 있는 차동식스포트형열감지기 현장점검용 표준화기기의 회로를 설계하고 시제품을 제작하였다. 개발된 시제품의 성능확인 결과 차동식스포트형열감지기의 형식승인시험 시 감도시험조건과 동일한 성능이 나타나는 것을 확인하였다.