• 제목/요약/키워드: rise height

검색결과 506건 처리시간 0.023초

고층건물에 작용하는 풍하중에 관한 수치 해석적 연구 (Numerical study of wind load on the high-rise building)

  • 송지수;박승오;김동우;하영철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.205-208
    • /
    • 2008
  • The wind load on building surface is numerically investigated. The geometry of target building is a square cross section and aspect ratio (height (H) to width (d)) is 6. On building surface, the pressure was measured, compared to obtained value from numerical simulation. The numerical simulations were done using URANS with three different turbulence models such as v2-f model, k-${\omega}$model, and k-${\varepsilon}$ model, respectively. The v2-f model showed the best agreement with experimental data in simulating mean pressure coefficients on front, rear and side surface. But unsteady characteristics of pressure history measured on surface is shown a discrepancy between experiment and numerical simulation.

  • PDF

초고층 건축물의 수직부재 보정 방법에 관한 연구 (A Study on The Compensation Method of Vertical Members for High-rise building)

  • 이재옥;소광호;유인근;양극영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문 발표회
    • /
    • pp.33-36
    • /
    • 2003
  • Time-dependent axial shortening in the cores and columns of tall concrete buildings requires special attention to ensure proper behavior for strength of the structure and the nonstructural clement. The effects of column shortening, both elastic and inelastic, take on added significance and need special consideration in design and construction with increased height of structures. In this paper, the compensation method of column shortening are introduced. It could be conclued that the survey is a significant factor for the compensation of column shortening.

  • PDF

UNIVERSAL AND SPECIFIC FEATURES IN INTONATION PERCEPTION

  • Makarova, Veronika
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2000년도 7월 학술대회지
    • /
    • pp.139-148
    • /
    • 2000
  • This paper reports the results of an experimental phonetic study of intonation contrasts perception by speakers of British English, Japanese and Russian. Six series of re-synthesized two-syllable rise-fall contours with manipulated parameters of the rise in the first and the fall in the second syllable were employed in the experiment. Modifications of pitch height were executed in 2 st steps, and of duration - in 30ms steps. The subjects, who were native speakers of British English, Japanese and Russian, identified the sentence type of presented re-synthesized stimuli. The results of the experiments demonstrate overall similarity of the perception strategies across the three groups of subjects, especially regarding the thresholds of 'declarative' sentence type judgement. Non-declarative judgements are more language-specific. The results can be employed for the teaching of English, Japanese and Russian as foreign languages as well as for speech synthesis and recognition.

  • PDF

초고층 건축물의 수직부재 보정 방법에 관한 연구 (A Study on The Compensation Method of Vertical Members for High-rise building)

  • 이재옥;소광호;유인근;양극영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.33-36
    • /
    • 2003
  • Time-dependent axial shortening in the cores and columns of tall concrete buildings requires special attention to ensure proper behavior for strength of the structure and the nonstructural element. The effects of column shortening, both elastic and inelastic, take on added significance and need special consideration in design and construction with increased height of structures. In this paper, the compensation method of column shortening are introduced. It could be concluded that the survey is a significant factor for the compensation of column shortening.

  • PDF

액체 요오드의 표면장력 (The Surface Tension of Liquid Iodine)

  • 김성완;장세헌
    • 대한화학회지
    • /
    • 제9권2호
    • /
    • pp.110-112
    • /
    • 1965
  • 액체 요오드의 표면장력을 측정하기 위하여 새로운 장치를 고안하고 differential capillary rise method를 써서 $125.0^{\circ}C,\;135.0^{\circ}C,\;145.0{\circ}C$$155.0^{\circ}C$ 에서 각각 36.88, 35.87, 34.83 및 34.04 dye/cm의 값들을 얻었다. 이 측정된 값들로부터 Eotvos 상수를 구해본 결과 각 온도에서 비슷한 값을 보여주고 있음을 알았다.

  • PDF

Construction of a 300-Meter Vertical City: Abeno Harukas

  • Mizutani, Kenichi;Hirakawa, Kiyoaki;Nakashima, Masato
    • 국제초고층학회논문집
    • /
    • 제4권3호
    • /
    • pp.199-207
    • /
    • 2015
  • Abeno Harukas is the tallest building in Japan and is located in Abeno, which is one of the three main railway transport nodes in Osaka. This building has a height of 300 meters, and its lowest levels are 30 meters below ground. It contains a department store, museum, offices, a hotel, and an observatory. In this urban renewal project, a section of the department store that encloses the station was dismantled and replaced by a supertall building complex, while infrastructure was simultaneously constructed, including: upgrades to the station and the existing department store, improved connections to the subway and pedestrian bridges, and a new pedestrian walkway over the road. In this paper, the ingenious erection processes, newly developed technologies, and precise construction management techniques are introduced for Japan's tallest building.

Placemaking in the High-Rise City: Architectural and Urban Design Analyses

  • Al-Kodmany, Kheir
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.153-169
    • /
    • 2013
  • The past decade has witnessed an unprecedented boom in tall and supertall building construction worldwide (Wood, 2011). Because of their massive bulk and soaring height, tall buildings often create serious placemaking problems. Employing extensive photographs and sketches, this paper examines architectural and urban design strategies that improve placemaking with tall buildings. The paper embraces a comprehensive approach that considers the relationship of tall buildings to their surroundings at the macro and micro scales. It also considers non-physical factors that tall buildings need to address, such as the social life the building creates. It is hoped that the placemaking factors discussed in this article will provide the required groundwork for future research that explores regulations and codes that foster placemaking with tall buildings.

인동간격에 따른 일조환경에 대한 연구 (A Study on Sunshine Environment with Different Distance between Buildings)

  • 최용석;최지혜;김용식
    • 한국주거학회논문집
    • /
    • 제15권2호
    • /
    • pp.55-62
    • /
    • 2004
  • Apartment design in residential Area is restricted by building distance limit code. Building distance limit decreases gradually to the 0.8H(height), and residential area has 250% site area ratio by building code, so site using has become efficient. In this study, examine the relationship between present building distance limit and right of daylighting environment by computer simulation. As well, high-rise residential officetel and multipurpose residential building becomes increase in commercial non-residential area. In the domestic, residential type multipurpose building made at the business area or central business area has 400∼800% site area ratio by building code. However, at a dweller's point of view, there are much lacks of environmental consideration to provide suitable daylighting environment. And, POE: Post Occupancy Evaluation is not completed yet. In this study, however, progress architectural environment prediction, basis by right of daylighting, and examine the possibility of daylighting by architectural distance limit code in residental area and by high-rise, high-density residential building in non-residental downtown area.

반복하중을 받는 철근콘크리트 저형 전단벽의 이력거동에 관한 실험적 연구(II) -바벨형 단면(Barbell Shape)의 내력과 연성을 중심으로- (Experimental Study on the Hysteretic Behavior of R/C Low-Rise Shear Walls under Cyclic Loads)

  • 최창식;이용재;윤현도;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.68-73
    • /
    • 1991
  • Results of an experimental investigation of low-rise reinforced concrete shear walls with barbell cross section under cyclic loads are discussed and evaluated. Four halr scale models of test specimens with height to length ratio of 0.75 were experimented. The dimension of all walls is 1500mm wide $\times$ 950 mm high $\times$ 100 mm thick and the section of all boundary column at both ends is 200 mm $\times$ 200mm. Main variables are : design concept, vertical flexural reinflrcement ratios and reinforcement details(including crossed diagonal shear reinforcement in SW7 specimen). In SW7 specimen, maximum strength and consequently dissipating energy index were 1.45 and 1.28 times greater than those of SW6 specimen, respectively.

  • PDF

A MULTI-STORY FIRE IN HIGH-RISE APARTMENT BUILDING DEVELOPED THROUGH BALCONIES - INVESTIGATION AND EXPERIMENTS -

  • Hasemi, Yuji;Hayashi, Yoshihiko;Hokugo, Akihiko;Yoshida, Masashi
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.361-368
    • /
    • 1997
  • Summary of experiments for the investigation of a fire which caused an upward fire spread for over 12 floors through balconies in a high-rise apartment complex is reported. The experiments include indoor tests to obtain fire properties of vertical PMMA fences and outdoor ones with a full scale model of the balcony. The test results suggest significance of the increase of total flame height by the merging of flames and a cooperative effect of the burning of the PMMA fence and combustibles on the balconies for the generation of a tall flame enough to cause ignition on the upper floors.

  • PDF