• Title/Summary/Keyword: rib height

Search Result 180, Processing Time 0.029 seconds

Behavior of Braced Rib Arch in Shallow Tunnel Excavated by Semi-Cut and Cover Method (반개착식으로 굴착한 천층터널에서 Braced Rib Arch의 거동)

  • An, Joung-Hwan;Lee, Sang-Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.419-425
    • /
    • 2009
  • Recently, the number of shallow tunnel construction increases to improve the structural safety and environment-friendliness. In Semi-Cut and Cover Method, ground is excavated to the crown arch level and braced rib arch is set to backfill before the excavation of lower face. Semi-Cut and Cover Method is proposed to solve the problems occurred by the conventional Cut and Cover Method, such as unstability, high-cost and the large cutting slope to be reinforced. In this paper, the behaviors of Braced Rib Arch in shallow tunnel excavated by semi-cut and cover method was studied. Model tests in 1:10 Scale were performed in real construction sequences. The distance between supports of rib arch was 1.8 m and the length of spacer was 1.0 m. the size of test pit was 4.0 m (width)$\times$3.3 m (length) 4.0 m (height) in dimension. Tests results show that backfill load acting on arch was smaller than that in the conventional Open-Cut Method.

The study on the electrical and optical characteristics as cell spec in ac-pdp (ac-PDP에서의 셀 치수에 따른 전기, 광학적 특성에 관한 연구)

  • Moon, Young-Seop;Lee, Sung-Hyun;Lim, Sung-Hyun;Shin, Choong-Hong;Yoo, Choong-Hee;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1582-1584
    • /
    • 2001
  • In ac plasma display(PDP), an image quality mainly depends on the contrast ratio. And the contrast ratio is affected by the driving condition and size of discharge cell. In this study, the electrical and optical characteristics during reset, address and sustain discharge were investigated as the height and width of barrier rib were varied in order to obtain the highest contrast ratio. As a result, the optimum rib height and width were 140${\mu}m$ and 600${\mu}m$, respectively.

  • PDF

Effects of Cell Structure on the Contrast Ratio in AC PDP

  • Park, Chung-Hoo;Moon, Young-Seop;Lee, Sung-Hyun;Kim, Goon-Ho;Kim, Dong-Hyun;Lee, Ho-Jun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.613-616
    • /
    • 2002
  • Luminance and contrast ratio is one of the most fundamental and important parameters of plasma display panel. Understanding the effects of cell design parameters on the display and background luminance is inevitable for improving the contrast ratio. We report the experimental results on the relationships between cell parameters and contrast ratio of the ac PDP driven by ADS scheme. It was found that the contrast ratio is the most significantly affected by rib height and optimum range of the rib height simultaneously affects the facing discharge during the reset periods, diffusion loss of plasma and shadowing of the visible light emitted from phosphor.

  • PDF

Heat Transfer and Friction in Rectangular Convergent Channels with Ribs on One Wall

  • Kim, Won-Cheol;Lee, Myung-Sung;Bae, Sung-Taek;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.12-18
    • /
    • 2014
  • The local heat transfer of developed turbulent flows in the stationary ribbed rectangular convergent channels has been investigated experimentally. The rectangular convergent channels with one ribbed surface only have the inclination of $0.72^{\circ}$ and $1.43^{\circ}$ at which the ribbed wall is manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (p) to height (e) =10. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000. The local heat transfer characteristics of the rectangular convergent channels are quite different from those of the ribbed square straight channel.

The Optimum Phosphor Thickness to Obtain the Highest Luminance and Luminous Efficiency in ac PDP

  • Heo, Jeong-Eun;Kim, Young-Kee;Park, Hun-Gun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.14-19
    • /
    • 2001
  • Plasma display panel(PDP) have gained great attention due to their potential application to large-area display including HDTV. The luminance and luminous efficiency of PDP, however, should be improved to realize this goal. In this study, we examined experimentally the effects of phosphor thickness and discharge gap on the luminance and luminous efficiency of ac PDP. For the rib height of 110 ${\mu}m$, whereas the optimum phosphor thickness was about 30 ${\mu}m$. The optimum thickness of green phosphor was about 50 ${\mu}m$ for the rib height of $120{\sim}160\;{\mu}m$.

  • PDF

A Study on the Welding Distortion Analysis According to Rib Height in Fillet Welding (필릿용접에서 리브높이에 따른 용접변형 해석에 대한 연구)

  • Kim, Yong-Rae;Song, Gyu-Yeong;Wang, Chao;Kim, Jae-Woong
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.107-111
    • /
    • 2013
  • The welding distortion is caused by welding heat in the structures which are widely used in shipbuilding and automotive industries, thus many researchers have proposed such methods to control the welding distortion through trials and numerical studies. The welding distortion has been the main cause of low productivity due to the structural strength degradation, apparent flaw, additional deformation caused by the process followed the current assembly step, and the increase of correction workload. The deformation of fillet welding is investigated in this study, and the influence of the rib height on the welding distortion is verified through the actual experiment. And the numerical analysis model using the FE software MSC.marc for analysis of welding distortion is proposed.

An Experimental Studies on Heat Transfer and Friction Factor in a Square Channel with Varying Number of Ribbed Walls

  • Oh Se-Kyung;Kim Won-Cheol;Ahn Soo-Whan;Kang Ho-Keun;Kim Myoung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.281-289
    • /
    • 2005
  • An experimental study on the heat transfer and friction characteristics of a fully developed turbulent air flow in a square channel with $45^{\circ}$ inclined ribs on one, two, and four walls is reported. Tests were performed for Reynolds number ranging from 7,600 to 24,900. The pitch-to-rib height ratio, p/e, was kept at 8 and rib height-to-channel hydraulic diameter ratio, $e/D_h$, was kept at 0.0667. The heat transfer coefficient and friction factor values were enhanced with the increase in the number of ribbed walls. Results of this investigation could be used in various applications of internal channel turbulent flows involving different number of roughened walls.

Effects of Rotation Speed on Heat Transfer and Flow in a Coolant Passage with Turning Region ( I ) - Cross Ribbed Duct - (곡관부를 가지는 내부 냉각유로에서 회전수 변화에 따른 열전달 및 유동 특성 ( I ) - 엇갈린 요철배열 덕트 -)

  • Kim Kyung Min;Kim Yun Young;Rhee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.737-746
    • /
    • 2005
  • The present study investigates heat/mass transfer and flow characteristics in a ribbed rotating passage with turning region. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter ($D_h$) of 26.67 mm. Rib turbulators are attached in the cross arrangement on the leading and trailing surfaces of the passage. The ribs have a rectangular cross section of $2\;mm\;(e){\times}\;mm\;(w)$ and an attack angle of $70^{\circ}$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio ($e/D_h$) is 0.075. The rotation number ranges from 0.0 to 0.20 while the Reynolds number is constant at 10,000. To verify the heat/mass transfer augmentation, internal flow structures are calculated for the same conditions using a commercial code FLUENT 6.1. The heat transfer data of the smooth duct for various Ro numbers agree well with not only the McAdams correlation but also the previous studies. The cross-rib turbulators significantly enhance heat/mass transfer in the passage by disturbing the main flow near the surfaces and generating one asymmetric cell of secondary flow skewing along the ribs. Because the secondary flow is induced in the first-pass and turning region, heat/mass transfer discrepancy is observed in the second-pass even for the stationary case. When the passage rotates, heat/mass transfer and flow phenomena change. Especially, the effect of rotation is more dominant than the effect of the ribs at the higher rotation number in the upstream of the second-pass.

Analysis of the turbulent flow on the periodically arranged semi-circular ribs in a rectangular channel (사각채널 내 주기적으로 배열된 반원 리브 영향의 유동해석)

  • Lee, G.H.;Nine, Md.J.;Choi, S.H.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 2011
  • The flow characteristics on the periodically arranged semi-circular ribs in a rectangular channel for turbulent flow have been investigated numerically. The aspect ratio of the rectangular channel was AR=5, the rib height to hydraulic diameter ratio was 0.07 and rib height to channel height ratio was e/H=0.117. The v2-f turbulence model and SST k-${\omega}$ turbulence model were used to find the flow characteristics of near the wall which are suited for realistic phenomena. The numerical analysis results show turbulent flow characteristics and pressure drop at the near the wall as observed experimentally. The results predict that turbulent kinetic energy(k) is closely relative to the diffusion of recirculation flow, and v2-f turbulence model simulation results have a good agreement with experimental.

Heat/Mass Transfer Augmentation in a Square Duct . Roughened with Angled Discrete Ribs Having Narrow Gaps (정사각 덕트 내에서 열/물질전달 촉진을 위한 경사진 단락 요철의 좁은 틈새 효과)

  • Wu, Seong-Je;Lee, Sei-Young;Choi, Chung;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.1
    • /
    • pp.150-158
    • /
    • 2002
  • Local heat/mass transfer and friction loss in a square duct roughened with various types of continuous and discrete rib turbulators are investigated. The combined effects of the gap flows of the discrete ribs and the secondary flows are examined for the purpose of the reduction of thermally weak regions and the promotion of the uniformity of heat/mass transfer distributions as well as the ;augmentation of average heat/mass transfer. The rib-to-rib pitch to the rib height ratio (p/e) of 8 and the rib angles of 90° and 60° are selected with e/D$\_$h/=0.08. The vortical structure of the secondary flows induced by the parallel angled arrays are quite distinct from that induced by the cross angled arrays. This distinction influences on heat/mass transfer and friction loss in all the tested cases. The gap flows of the discrete ribs reduce the strength of the secondary flows but promote local turbulence and flow mixing. Consequently, the angled discrete ribs with the small gaps provide a more uniform heat/mass transfer distribution sustaining high average heat/mass transfer.