• 제목/요약/키워드: restorative material

검색결과 406건 처리시간 0.023초

Effect of moisture and drying time on the bond strength of the one-step self-etching adhesive system

  • Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제37권3호
    • /
    • pp.155-159
    • /
    • 2012
  • Objectives: To investigate the effect of dentin moisture degree and air-drying time on dentin-bond strength of two different one-step self-etching adhesive systems. Materials and Methods: Twenty-four human third molars were used for microtensile bond strength testing of G-Bond and Clearfil $S^3$ Bond. The dentin surface was either blot-dried or air-dried before applying these adhesive agents. After application of the adhesive agent, three different air drying times were evaluated: 1, 5, and 10 sec. Composite resin was build up to 4 mm thickness and light cured for 40 sec with 2 separate layers. Then the tooth was sectioned and trimmed to measure the microtensile bond strength using a universal testing machine. The measured bond strengths were analyzed with three-way ANOVA and regression analysis was done (p = 0.05). Results: All three factors, materials, dentin wetness and air drying time, showed significant effect on the microtensile bond strength. Clearfil $S^3$ Bond, dry dentin surface and 10 sec air drying time showed higher bond strength. Conclusions: Within the limitation of this experiment, air drying time after the application of the one-step self-etching adhesive agent was the most significant factor affecting the bond strength, followed by the material difference and dentin moisture before applying the adhesive agent.

Effect of three nanobiomaterials on microhardness of bleached enamel

  • Khoroushi, Maryam;Shirban, Farinaz;Kaveh, Sara;Doustfateme, Samaneh
    • Restorative Dentistry and Endodontics
    • /
    • 제41권3호
    • /
    • pp.196-201
    • /
    • 2016
  • Objectives: The aim of this in vitro study was to evaluate the effect of incorporating three different nanobiomaterials into bleaching material on microhardness of bleached enamel. Materials and Methods: The crowns of 24 extracted sound human molars were sectioned. Sixty enamel specimens ($2{\times}3{\times}4 mm$) were selected and divided into five groups (n = 12): Group 1 received no bleaching procedure (control); Group 2 underwent bleaching with a 40% hydrogen peroxide (HP) gel; Groups 3, 4, and 5 were bleached with a 40% HP gel modified by incorporation of bioactive glass (BAG), amorphous calcium phosphate (ACP) and hydroxyapatite (HA), respectively. The enamel microhardness was evaluated. The differences in Knoop microhardness data of each group were analyzed by one-way ANOVA, followed by post hoc Tukey tests. Results: Significant differences were observed between the study groups. The enamel microhardness changes in Groups 1, 3, 4, and 5 were significantly lower than that of Group 2 (p < 0.001). Conclusions: Within the limitations of this study, it can be concluded that incorporation of each one of the three tested biomaterials as remineralizing agents might be effective in decreasing enamel microhardness changes subsequent to in-office bleaching.

치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가 (Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece)

  • 한명철;김정관;최명욱
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

호제근충재(糊劑根充材) Vitapex의 근관폐쇄성(根管閉鎖性)에 관(關)한 연구(硏究) (A STUDY ON THE USE OF VITAPEX WITH GUTTA-PERCHA CONES AS A ROOT CANAL FILLER)

  • 임성삼
    • Restorative Dentistry and Endodontics
    • /
    • 제9권1호
    • /
    • pp.127-132
    • /
    • 1983
  • The purpose of this study was to examine the sealing ability of the vitapex, when used with gutta-percha cone, as a root canal filling material. Fourty five canals from extracted human maxillary and mandibular teeth were randomly selected and instrumented in a conventional method with k-file. After instrumentation and dry the canal with paper points, the canals were divided into three groups and fifteen canals in each group were filled with the following materials; Vitapex, Vitapex in combination with gutta-percha cone, and Gutta-percha cone and Zinc-oxide Eugenol Cement. All the specimens were immersed in 2% methylenblue dye solution and the depth of dye penetration into the canals were evaluated by macroscope at the intervals of 1 day, 2days and 7days. The following results were obtained; 1. All the materials experimented showed varying degrees of dye penetration. 2. The canals filled with Vitapex and Vitapex in combination with gutta perch a cone revealed sudden increase of dye penetration with time passage compared to the canals obturated with Gutta-percha cone and Zinc-oxide eugenol cement. 3. In the canals filled with Vitapex, the mean dye penetration was 1.6mm at 1day, but the specimen exposed to the dye for 7days showed mean dye penetration of 9.2mm. 4. In the canals obturated with Vitapex and gutta-percha cone, the mean dye penetration was 2mm at 1day, 2.2mm at 2days, and 8mm at 7days.

  • PDF

불화물(弗化物)의 상아질도포효과(象牙質塗布效果)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY OF THE EFFECT OF FLUORIDES ON HUMAN DENTIN)

  • 전동문;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제13권1호
    • /
    • pp.23-38
    • /
    • 1988
  • In order to investigate the material formed by application of fluoride on human dentin, exposed dentin of tooth cervix and sound dentin powder was treated by several fluoride solutions. The former was observed by scanning electron microscope and the latter was analysed by x-ray diffractometer and infrared spectrophotometer. The results obtained were as follows: 1. Application with NaF, $SnF_2$ and $Na_2PO_3F$ on exposed dentin of tooth cervix formed mineralized materials covered. 2. The amount of mineralized materials increased with time intervals of applying the fluorides. 3. The density of mineralized materials was highest in $Na_2PO_3F$ treatment group, and NaF treatment group was higher than $SnF_2$ treatment group. 4. $SnF_2$ remained in covering of mineralized materials. 5. Application with NaF and $Na_2PO_3F$ formed mineralized materials characterized apatitic crystals. 6. The crystallinity of mineralized materials was higher prominently in $Na_2PO_3F$ treatment group.

  • PDF

Retrofilling시 수종충전재료의 변연누출에 관한 연구 (A COMPARATIVE STUDY ON THE APICAL LEAKAGE OF VARIOUS RETROFILLING MATERIALS)

  • 온영석;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.118-125
    • /
    • 1991
  • Eighty - eight recently extracted teeth were used to evaluate the leakage characteristics of the following retrofilling materials; amalgam, zinc oxide eugenol cement, glass - ionomer cement, and cermet glass - ionomer cement. Root canals were prepared with step - back method and obturated with gutta percha and zinc oxide eugenol sealer. Root apex were resected 2 mm from apex and class I cavities were prepared with 2 mm or 4 mm depth. The cavities were filled with above materials. After application of varnish on all surface except resected surface, the roots were placed in 1 % methylene blue solution for 6 days. After longitudinal polishing to expose cental parts of filled materials, penetrated depths of dye were measured. The results were as follws. 1. As retrofilling material, glass ionomer cement filling groups showed less leakage than the other groups except zinc oxide eugenol cement filling group(p<0.01). 2. Amalgam filling groups had greater leakage than zinc oxide eugenol cement filling group(p<0.01). 3. 4 mm depth of retrofilled cavity had no effect on leakage characteristics compared with 2 mm depth cavity(p>0.05). 4. Glass ionomer cement and cermet glass ionomer cement filling groups showed less apical leakage than amalgam filling groups. But there was no statistical significance(p>0.05). 5. There was no difference in apical leakage between glass ionomer cement filling groups and cermet glass ionomer cement filling groups(p>0.05).

  • PDF

수종 표면 보호재의 도포가 광중합형 유리 아이오너머 수복물의 변연 누출 및 미세 경도에 미치는 영향 (The effect of various surface coatings on microleakage and microhardness of light-cured glass ionomer restoration)

  • 김기섭;김용기
    • 대한소아치과학회지
    • /
    • 제24권3호
    • /
    • pp.495-510
    • /
    • 1997
  • The purpose of this study was to evaluate the efficacy of several surface coating agents in preventing microleakage and increasing microhardness of light-cured glass ionomer restoration. 50 and 25 sound molar teeth were used for the microleakage test and microhardness test respectively. Data were analyzed statistically using Kruskal-Wallis and/or Mann-Whitney test. The results of the present study were as follows: 1. The effect of surface coating in reducing microleakage was proven only at the gingival margin of restorations with statistical significance(p<.05). 2. The distribution of microleakage score at gingival margin was shown to be better than that of occlusal margin in general but with no statistically significant differences(p>.05). 3. No statistically significant differences in microhardness could be found between groups (p>.05) regardless of depth of measurement. 4. Under the present experimental conditions, the types or application of surface coating agents did not impose any significant effect on microhardness of glass ionomer restorative material whereas the protective effect of surface coating in reducing microleakage was partly proven.

  • PDF

A micro-computed tomography evaluation of voids using calcium silicate-based materials in teeth with simulated internal root resorption

  • Tek, Vildan;Turker, Sevinc Aktemur
    • Restorative Dentistry and Endodontics
    • /
    • 제45권1호
    • /
    • pp.5.1-5.8
    • /
    • 2020
  • Objectives: The obturation quality of MTA, Biodentine, Total Fill BC root canal sealer (RCS), and warm gutta-percha (WGP) in teeth with simulated internal root resorption (IRR) was evaluated by using micro-computed tomography. Materials and Methods: Standardized IRR cavities were created using 40 extracted maxillary central incisor teeth and randomly assigned into 4 groups (n = 10). IRR cavities were filled with MTA, Biodentine, Total Fill BC RCS (bulk-fill form) and WGP + Total Fill BC RCS. Percentage of voids between resorptive cavity walls and obturation material (external void), and inside the filling materials (internal voids) were measured. Results: Total Fill BC sealer in the bulk-fill form presented significantly highest values of external and internal void percentages (p < 0.05). Biodentine showed a significantly lowest external void percentage (p < 0.05). WGP + Total Fill BC RCS presented significantly lower values of internal void percentages than all groups (p < 0.05), except Biodentine (p > 0.05). Conclusion: None of the filling materials were created void-free obturation in resorption cavities. Biodentine may favor its application in teeth with IRR over Angelus MTA and bulkfill form of Total Fill BC.

잔존 상아질 후경에 따른 S. mutans의 성견 치수반응에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF THE EFFECT OF S. MUTANS ON THE PULP IN RELATION TO THE REMAINING DENTIN THICKNESS)

  • 김형동
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.34-45
    • /
    • 1990
  • The purpose of this study was to evaluate the pulpal responses of S. mutans (6715, serotype A) in relation to the remaining dentin thickness. The material was consisted of 72 teeth from 6 dogs. Cl. V cavities were prepared into 2 different thickness (0.5mm, 1.0mm) of remaining dentin. In the control groups, the cavities were filled with filter paper of broth, tin foil, and IRM$^{(R)}$ cement. In the experimental groups, the cavities were filled with filter paper of S. mutans, filter paper of broth, tin foil, and IRM$^{(R)}$ cement. The intervals of observation period were 1 week, 3 weeks, and 8 weeks respectively after the experiment. The specimens were fixed with 10% formalin and decalcified in 5% nitric acid. All specimens were stained with Hematoxylin-Eosin and examined histopathologically under the microscope. The results were as follows. 1. The changes and congestion of odontoblastic layers were more frequent and lasting in the control group of 0.5mm than in that of 1.0mm remaining dentin thickness. 2. There was no characteristic difference between the control group of 1.0mm and the experimental group of 1.0mm in all pulp responses. 3. Acute and chronic inflammatory cells were seen in the experimental group of 0.5mm, but not seen in the control group of 0.5mm.

  • PDF

Retrograde filling시 수종 충전재료에 따른 폐쇄효과에 대한 연구 (A STUDY OF THE APICAL LEAKAGE OF VARIOUS RETROGRADE FILLING MATERIALS)

  • 도정욱;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.97-105
    • /
    • 1989
  • This study was conducted to evaluate and compare the apical leakage among the retrograde filling materials; retrograde filling with non-zinc amalgam, cavity varnish and non-zinc amalgam, z.o.e cement, Glass Ionomer cement, scotch bond and silux. Sixty single rooted teeth were divided into six groups and each tooth was individually prepared for its particular group. The specimens were incubated at $37^{\circ}C$ for 24 hrs and then were infiltrated by 2% methylene blue for 7 days. Apical leakage was evaluated by measuring the degree of dye penetration between the filling material and the canal wall. The results were as follows: 1. The scotch bond and silux group showed the least amount of apical leakage and the control group showed the greatest amount of apical leakage. 2. The groups retrofilled with cavity varnish and amalgam, glass-Ionomer cement, scotch bond and silux showed significantly good apical seal than control group. 3. The groups retrofilled with glass Ionomer cement, scotchbond and silux showed significantly good apical seal than the groups retrofilled with Amalgam and Zinc oxide eugenol cement.

  • PDF