• Title/Summary/Keyword: response pattern

Search Result 1,484, Processing Time 0.029 seconds

Relationship Analysis of Power Consumption Pattern and Environmental Factor for a Consumer's Short-term Demand Forecast (전력소비자의 단기수요예측을 위한 전력소비패턴과 환경요인과의 관계 분석)

  • Ko, Jong-Min;Song, Jae-Ju;Kim, Young-Il;Yang, Il-Kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.11
    • /
    • pp.1956-1963
    • /
    • 2010
  • Studies on the development of various energy management programs and real-time bidirectional information infrastructures have been actively conducted to promote the reduction of power demands and CO2 emissions effectively. In the conventional energy management programs, the demand response program that can transition or transfer the power use spontaneously for power prices and other signals has been largely used throughout the inside and outside of the country. For measuring the effect of such demand response program, it is necessary to exactly estimate short-term loads. In this study, the power consumption patterns in both individual and group consumers were analyzed to estimate the exact short-term loads, and the relationship between the actual power consumption and seasonal factors was also analyzed.

Prediction of Deficiency Pattern in Diabetic Patients Using Multi-frequency Bioimpedance Resistance (다주파수 생체임피던스 저항을 이용한 당뇨병 환자의 허증 변증 예측)

  • Kim, Kahye;Kim, Seul Gee;Cha, Jiyun;Yoo, Ho-Ryong;Kim, Jaeuk U.
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.94-99
    • /
    • 2022
  • The discovery of biomarkers related to pattern identification (PI), the core diagnostic theory of Korean medicine (KM), is one of the methods that can provide objective and reliable evidence by applying PI to clinical practice. In this study, 40 diabetic patients and 41 healthy control subjects recruited from the Korean medicine clinic were examined to determine the human electrical response related to the deficiency pattern, a representative pattern of diabetes. Qi-Blood-Yin-Yang deficiency pattern scores, which are representative deficiency patterns for diabetes mellitus, were obtained through a questionnaire with verified reliability and validity, and the human electrical response was measured non-invasively using a bioimpedance meter. In ANCOVA analysis using gender as a covariate, the 5 kHz frequency resistance and 5-250 kHz frequency reactance were significantly lower in the diabetic group than in non-diabetic control group. In addition, the multiple regression analysis showed a positive correlation (R2=0.11~0.19) between the Yang deficiency pattern score and resistance value for the diabetic group; the correlation was higher at higher frequencies of 50kHz (R2=0.18) and 250kHz (R2=0.19) compared to 5kHz(R2=0.11). In contrast, there was no such significant association in the control group. It implies that bioimpedance resistance measured at finite frequencies may be useful in predicting Yang deficiency, which is closely related to diabetic complications by reflecting the decrease in body water content and metabolism. In the future, large-scale planned clinical studies will be needed to identify biomarkers associated with different types of PI in diabetes.

Analysis of the Simon effect using Amplitude of RTA-ERP and Response time (응답속도정합-유발전위의 진폭과 응답 속도를 이용한 사이먼효과 분석)

  • Kim, HyeJin;Yoo, SunKook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.179-185
    • /
    • 2013
  • In this paper, the RTA-ERP(Response Time Aligned-Evoked Relative Potential) was modelled to analyze the effect of motor activation pattern in response to visual sensory stimuli. Simon effect was analysed using the amplitude response of RTA-ERP and measured response time. The 'odd number' experiments, which identify an odd number mixed with same numbers, was performed with 15 healthy adult participants(9 males and 6 females, whose mean age of 31) for 7 minutes for each participant. Throughout experimentation, we observed that the proposed RTA-ERP can compensate the timing variation due to different neural processing procedures in the brain, and shows enhanced LRP(Lateralized Readiness Potential) and Pe(Error Related Positivity). Regarding to 'congruence' and 'incongruence' testing patterns, the amplitude of RTA-ERP and the response time for the 'congruence' are $0.03{\mu}V$ larger, and 43 ms faster than those for the 'incongruence', respectively. The amplitude characteristics of RTA-ERP, obtained by synchronizing the onset times with respect to response time, corresponds more likely to that of P300 in the ERP pattern (the characteristics of the Simon effect).

A Study on Accuracy Improvement of Dual Micro Patterns Using Magnetic Abrasive Deburring (자기 디버링을 이용한 복합 미세패턴의 형상 정밀도 향상)

  • Jin, Dong-Hyun;Kwak, Jae-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.11
    • /
    • pp.943-948
    • /
    • 2016
  • In recent times, the requirement of a micro pattern on the surface of products has been increasing, and high precision in the fabrication of the pattern is required. Hence, in this study, dual micro patterns were fabricated on a cylindrical workpiece, and deburring was performed by magnetic abrasive deburring (MAD) process. A prediction model was developed, and the MAD process was optimized using the response surface method. When the predicted values were compared with the experimental results, the average prediction error was found to be approximately 7%. Experimental verification shows fabrication of high accuracy dual micro pattern and reliability of prediction model.

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

Calculation of Composite Desirability Function According to the Measurement Unit and Numerical Pattern of Characteristics in the Multiple Response Analysis (MRA에서 특성값의 측정단위와 수치형태에 따른 종합 만족도 산출 방법)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2009.11a
    • /
    • pp.565-572
    • /
    • 2009
  • This paper presents the optimization steps with weight and importance of estimated characteristic values in the multiresponse surface analysis(MRA). The research introduces the shape parameter of individual desirability function for relaxation and tighening of specification bounds. The study also proposes the combinded desirability function using arithmetic, geometric and harmonic means considering the measurement unit and numerical pattern.

  • PDF

A1gorithm Embodiment for Automatic Pump Operation Pattern (원격지 수도시설 펌프운영 패턴의 자동화 알고리즘 구현)

  • Byun, Doo-Gyoon;Yoon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2474-2476
    • /
    • 2003
  • An algorithm was embodied to automatic pump operation Pattern for remote control located in 60 km far. This automation pattern included least cost operation, peak load time response, pump operation time balancing etc. It was programmed four kind of operation mode as following; normal operation nude, before peak load time nude, peak load time operation, after peak load time operation.

  • PDF

The Effect of Emotional Response on Satisfaction according to the Dining-Out Consumption Pattern (외식 소비 성향에 따른 감정 반응이 만족도에 미치는 영향)

  • Kim, Ki-Young;Baek, Jong-On
    • Culinary science and hospitality research
    • /
    • v.16 no.3
    • /
    • pp.147-160
    • /
    • 2010
  • This study aims to analyze the effect of emotional response from dining out experience on satisfaction after dining out based on the customers who have visited a luxurious Korean restaurant. For this study, it designed a research model through literary research and derived hypotheses. For the empirical analysis, 250 copies of the questionnaire using the self-administered method were distributed and 230(94%) copies were collected. Among them, 220(88%) copies were used for the analysis. SPSS WIN Version 12.0 statistical package program was used for the analysis of data processing, the frequency analysis, reliability analysis and factor analysis were operated, and the hypothesis testing was verified by the regression analysis. The results of the analyses are as follows. For the hypothesis that "the dining-out consumption pattern will have a significant effect on the emotional response," it was verified that the style which pursues health and the style which is loyal to relationships had significant effects on pleasure while the style which pursues rest didn't. Also, the style which pursues health and the style which is loyal to relationships had significant effects on arousal while the style which pursues rest didn't. For the hypothesis that "emotional response will have a significant effect on satisfaction," it was verified that pleasure and simulation had significant effects on satisfaction. As a result of the study, the current dining-out consumption pattern is changed from the purpose of having meals for the biological needs in the past to considering emotional response such as preferred taste or mood.

  • PDF

Cell-type-specific Gene Expression Patterns in Human Carcinoma Cells followed by Irradiation (방사선에 의한 암세포주 특이적 유전자 발현 양상)

  • Park Ji-Yoon;Kim Jin-Kyu;Chai Young Gyu
    • Korean Journal of Environmental Biology
    • /
    • v.23 no.2 s.58
    • /
    • pp.152-156
    • /
    • 2005
  • Ionizing radiation is a well- known therapy factor for human carcinoma cells. Genotoxic stress mediates cell cycle control, transcription and cellular signaling. In this work, we have used a microarray hybridization approach to characterize the cell type-specific transcriptional response of human carcinoma MCF-7 and HeLa cell line to $\gamma-radiation$, such as 4Gy 4hr. We found that exposure to $\gamma-ray$ alters by at least a $log_2$ factor of 1.0 the expression of known genes. Of the 27 genes affected by irradiation, 11 are down- regulated in MCF-7 cells and 2 genes induced by radiation,15 are repressed in HeLa cells. Many genes were involved in known damage- response pathways for cell cycling, transcription factor and cellular signaling response. However, in MCF-7 cells, we observed gene expression pattern in chromatin, apoptosis, stress, differentiation, cytokine, metabolism, ribosome and calcium. In HeLa cells, it showed clearly the expression changes in adhesion and migration, lysosome, brain, genome instability and translation. These insights reveal new therapy directions for studying the human carcinoma cell response to radiation.

The Pattern of Failure after Definitive Radiotherapy for Squamous Cell Carcinoma of the Lung (편평상피 세포성 폐암의 방사선치료 실패 양상)

  • Jang Yang Suk;Kim Jae Cheol;Ryu Samuel;Park In Kyu
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 1989
  • From Feb.1985 to Feb.1988,76 patients with squamous cell carcinoma of the lung treated at the Department of Therapeutic Radiology in Kyungpook National University Hospital were available for the analysis of this study. All patients received radiation of 4000cGy-6600cGy with curative aim. The overall rate of complete response was 25.0% and partial response was 452.6% The complete and partial regression of tumor was 14.3% in patients treated with dose below 5000cGy and 84.1% in the group treated with dose above 5000cGy (p<0.01). The complete response was seen only in the group of patients received radiation at least 6000cGy. The patterns of failure were as follows. The rate of initial intrathoracic recurrence was 52.6% in patients with complete response. The overall rate of failure was 68.8%. Distant metastasis was found in 47.4% of patients. Bone, contralateral lung, and brain were common metastatic sites in decreasing order All of the distant metastases and 80% of local recurrences were found within the first year after treatment.

  • PDF