• Title/Summary/Keyword: resonant sensor

Search Result 215, Processing Time 0.028 seconds

Study on Relation of Optimum Resonant Frequencies between Piezo Ceramic and Matching Layer (피에조 세라믹과 매칭레이어와의 최적 공진주파수 관계에 대한 연구)

  • Kim, Kwon-Se;Choi, Doo-Seuk;Kim, Young-Choon;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3191-3196
    • /
    • 2013
  • Ultrasonic transducer is the sensor which is measuring distance. Piezo ceramic of ultrasonic sensor and adhesive technique of matching layer are the most core techniques. With the study of relation on matching layer which takes off the ultrasonic wave into the air, this paper aims to find the second useful frequency as the results which can be changed are extracted in case piezo ceramic and matching layer are bonded. And the experiment is done with piezo ceramic as real piezoelectric element and matching layer of chemical wood. OD of piezo ceramic has designed by ${\Phi}50{\times}3T$ and OD of matching layer is designed by ${\Phi}62{\times}12t$ with ${\lambda}=1/4$. Acoustic impedance is generated at the most optimum resonant frequency of 53 Khz. As experimental result, more available frequency can be generated by using the adhesive close to solid than the flexible one.

A Telemetry Silicon Pressure Sensor of LC Resonance Type (LC공진을 이용한 원격측정용 압력센서의 제작 및 실험)

  • Kim, Hak-Jin;Kim, Soon-Young;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1872-1874
    • /
    • 2001
  • This paper presents an implantable telemetry LC resonance-type pressure sensor to measure the cerebral ventricle pressure. The sensor consists of an inductor and a capacitor. The LC resonant circuit consists of the sensor and an external antenna coil that are coupled magnetically. The resonance frequency of the circuit decreases as the applied pressure increases the capacitance of the sensor. The sensor is designed in consideration of the biocompatibility and long lifetime for continuous monitoring of the ventricle pressure. The sensor is simple to fabricate and small in comparison with others reported previously. The inductor is fabricated by electroplating and the variable capacitor is constructed with a flexible p+ diaphragm. Also, the deflection of the diaphragm, the variation of the capacitance and the resonance frequency are analyzed and calculated.

  • PDF

A Study on an Activated Carbon Coated Sensor for the Detection of Marine Pollution (해양오염 감지를 위한 활성탄 코팅 센서에 관한 연구)

  • 최광재;김영한
    • Journal of Korean Port Research
    • /
    • v.14 no.3
    • /
    • pp.373-378
    • /
    • 2000
  • Oil spill in sea water is the most frequent and significant problem of marine pollution. As an early detection sensor of the pollution, an activated carbon coated quartz crystal is prepared and examined for its performance of detection sensitivity and stability. Powdered activated carbon and phenol resin is coated on the surface of the sensor and the sensor is baked for an hour. Adsorption of acetone dissolved in water and salt water is measured using frequency shift of quartz crystal at different concentrations of solute material. The outcome indicates that the sensor preparation is adequate and the measurement of solute concentration is stable and sensitive enough to be implemented on the monitoring of solute concentration is stable and sensitive enough to be implemented in the monitoring of organic pollution of sea water.

  • PDF

Development of a MEMS Resonant Accelerometer Based on Robust Structural Design (강건 구조설계에 기반한 미소 공진형 가속도계의 개발)

  • Park, U-Sung;Boo, Sang-Pil;Park, Soo-Young;Kim, Do-Hyung;Song, Jin-Woo;Jeon, Jong-Up;Kim, Joon-Won
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.114-120
    • /
    • 2012
  • This paper describes the design, fabrication and testing of a micromachined resonant accelerometer consisting of a symmetrical pair of proof masses and double-ended tuning fork(DETF) oscillators. Under the external acceleration along the input axis, the proof mass applies forces to the oscillators, which causes a change in their resonant frequency. This frequency change is measured to indicate the applied acceleration. Pivot anchor and leverage mechanisms are adopted in the accelerometer to generate larger force from a proof mass under certain acceleration, which enables increasing its scale factor. Finite element method analyses have been conducted to design the accelerometer and a silicon on insulator(SOI) wafer with a substrate glass wafer was used for fabricating it. The fabricated accelerometer has a scale factor of 188 Hz/g, which is shown to be in agreement with analysis results.

A Study on the Identification Odorants using Six Channel Piezoelectric Crystals (6채널 압전소자를 이용한 냄새인식에 관한 연구)

  • 권영수;장상목;박옥순;최용성
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.947-950
    • /
    • 1992
  • At-cut quartz crystal has been applied as chemical vapour sensors. The responses of quartz crystal at 9 MHz coated with phosphatidylglycerol(PG), phosphatidylinositol(PI), phosphatidylethanolamine(PE), phosphatidylserine(PS), and lipid A(LA) are determined for amyl acetate, acetoin, menthone and other organic gases which showed different affinities for each lipid. The identification of odorants depending on the species of lipid used for coating is discussed in terms of the normalized resonant frequency shift pattern.

  • PDF

Telemetry Silicon Pressure Sensor Using LC Resonance (LC 공진을 이용한 원격측정용 실리콘 압력센서)

  • Kim, Soon-Young;Pak, Jean-Sung;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2254-2256
    • /
    • 2000
  • This paper presents an implantable telemetry LC resonance-type pressure sensor for the measurement of the ventricle pressure. This sensor consists of a capacitor and an inductor. This resonant circuit is magnetically coupled with an external antenna coil. The resonance frequency of the circuit decreases as the sensor capacitance is increased by the applied pressure. The inductance and the capacitance are 428nH and 0.98${\mu}F$, respectively. The resonance frequency is 245.7MHz when the differential pressure is zero. The sensitivity of the sensor is 9.477kHz/Pa.

  • PDF

A new reconfigurable liquid-metal-antenna-based sensor

  • Zhou, Xiaoping;Fu, Yihui;Zhu, Hantao;Yu, Zihao;Wang, Shanyong
    • Smart Structures and Systems
    • /
    • v.30 no.4
    • /
    • pp.353-369
    • /
    • 2022
  • In this paper, a new sensor chip with frequency reconstruction range of 2.252 GHz ~ 2.450 GHz is designed and fabricated. On this basis, a self-designed "T-shaped" shell is added to overcome the disadvantage of uneven deformation of the traditional steel shell, and the range of the sensor chip is expanded to 0 kN ~ 96 kN. The liquid metal antenna is used to carry out a step-by-step loading test, and the relationship between the antenna resonance frequency and the pressure load is analyzed. The results show that there is a good linear relationship between the pressure load and the resonant frequency. Therefore, the liquid metal antenna can be regarded as a pressure sensor. The cyclic loading and unloading experiments of the sensor are carried out, and different loading rates are used to explore the influence on the performance of the sensor. The loading and unloading characteristic curves and the influence characteristic curves of loading rate are plotted. The experimental results show that the sensor has no residual deformation during the cycle of loading and unloading. Moreover, the influence of temperature on the performance of the sensor is studied, and the temperature correction formula is derived.

Detection of odorants and study on the odorant sensor system by using SAW device (SAW 디바이스를 이용한 냄새물질 측정 및 냄새센서 시스템의 연구)

  • 장상목;김기영;김종민;최용성;권영수
    • Electrical & Electronic Materials
    • /
    • v.8 no.1
    • /
    • pp.48-55
    • /
    • 1995
  • A surface acoustic wave (SAW) sensor for the detection of odorants has been constructed by depositing various phospholipids and fatty acids onto the surface of the SAW device. The characteristics of a SAW device operating at 310 MHz deposited with silicon monoxide were analyzed. Menthone, amylacetate, acetoin, and other organic gases show different affinities to the coated lipids. An explanation is given for different odorant affinities based on the monolayer properties of phospholipids. The identification of odorants depending on the tkpe of lipid used for coating is discussed in terms of the similarity of their normalized resonant frequency shift patterns. Using a number of different lipid-coated SAW devices, odorants can be identified by a computerized pattern recognition algorithm.

  • PDF