• Title/Summary/Keyword: resonance test

Search Result 991, Processing Time 0.029 seconds

Analysis on the Degree of Cerebral Activity According to Cognition Task in Welders Exposed to Manganese (망간 노출 용접공의 인지수행에 따른 뇌 활성화 정도 분석)

  • Choi, Jae-Ho
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2011
  • In this study, we examined the impact caused by chronic exposure to Mn by investigating the degree of brain activation based on the data of recognition activities using fMRI (functional magnetic resonance imaging). A questionnaire survey, blood tests, and fMRI tests were carried out with respect to two groups. Group 1 was an exposure group consisting of 15 male workers who are 34 years old or older, and who worked for longer than 10 years in a shipbuilding factory as a welder. Group 2 was a control group consisting of 15 workers in manufacturing industries with the same gender and age. The results showed that blood Mn concentration of Group 1($1.3\;{\mu}g/dl$) was significantly higher than that of Group 2($0.8\;{\mu}g/dl$)(p < 0.001), and Pallidal Index (PI) of Group 1 was also significantly higher than that of Group 2 (p < 0.001). PI value of the group whose blood Mn concentration was $0.93\;{\mu}g/dl$ or higher was significantly higher than that of the group whose blood Mn concentration was less than $0.93 \;{\mu}g/dl$ (p < 0.001). As for brain activity area within the control group, the right and the left areas of occipital cortex showed significant activity and the left area of middle temporal cortex, the right area of superior inferior frontal cortex and inferior parietal cortex showed significant activity. Unlike the control group, the exposure group showed significant activity on the right area of superior inferior temporal cortex, the left of insula area. In the comparison of brain activity areas between the two groups, the exposure group showed significantly higher activation than the control group in such areas as the right inferior temporal cortex, the left area of superior parietal cortex and occipital cortex, and cerebellum including middle temporal cortex. However, in nowhere the control group showed more activated area than the exposure group. As the final outcome, chronic exposure to Mn increased brain activity during implementation of arithmetic task. In an identical task, activation increased in superior inferior temporal cortex, and insula area. And it was discovered that brain activity increase in temporal area and occipital area was more pronounced in the exposure group than in the control group. This result suggests that chronic exposure to Mn in the work environment affects brain activation neuro-network.

A study on Evaluating Validity of SNR Calculation Using a Conventional Two Region Method in MR Images Applied a Multichannel Coil and Parallel Imaging Technique (다중채널코일과 병렬영상기법 이용 시 두영역측정법을 사용한 신호대잡음비 측정의 문제점)

  • Choi, Kwan-Woo;Son, Soon-Yong;Min, Jung-Whan;Kwon, Kyung-Tae;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.403-410
    • /
    • 2015
  • The purpose of this study was to investigate the problems of a signal to noise ratio measurement using a two region measurement method that is conventionally used when using a multi-channel coil and a parallel imaging technique. As a research method, after calculating the standard SNR using a single channel head coil of which coil satisfies three preconditions when using a two region measurement method, we made comparisons and evaluations after calculating an SNR by using a two region measurement method of which method is problematic because it is used without considering the methods recommended by reputable organizations and the preconditions at the time of using a multi-channel coil and a parallel imaging technique. We found that a two region measurement method using a multi-channel coil and a parallel imaging technique shows the highest relative standard deviation, and thus shows a low degree of precision. In addition, we found out that the difference of SNR according to ROI location was very high, and thus a spatial noise distribution was not uniform. Also, 95% confidence interval through Blend-Altman plot is the widest, and thus the conformity degree with a two region measurement method using the standard single channel head coil is low. By directly comparing an AAPM method, which serves as a standard of a performance evaluation test of a magnetic resonance imaging device under the same image acquisition conditions, an NEMA method which can accurately determine the noise level in a signal region and the methods recommended by manufacturers of a magnetic resonance imaging device, there is a significance in that we quantitatively verified the inaccurate problems of a signal to noise ratio using a two region measurement method when using a multi-channel coil and a parallel imaging technique of which method does not satisfy the preconditions that researchers could overlook.

Static and Dynamic Analysis for Railway Tunnel according to Filling Materials for overbroken tunnel bottom (철도터널 하부 여굴처리 방법에 대한 정적 및 동적 안정성 검토)

  • Seo, Jae-Won;Cho, Kook-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.668-682
    • /
    • 2017
  • Alignments of railways recently constructed in Korea have been straightened due to the advent of high-speed rail, which means increasing the numbers of tunnels and bridges. Overbreak during tunnel construction may be unavoidable, and is very influential on overall stability. Over-excavation in tunneling is also one of the most important factors in construction costs. Overbreak problems around crown areas have decreased with improvements of excavation methods, but overbreak problems around bottom areas have not decreased because those areas are not very influential on tunnel stability compared with crown areas. The filling costs of 10 cm thickness of overbreak at the bottom of a tunnel are covered under construction costs by Korea Railway Authority regulations, but filling costs for more than the covered thickness are considered losses of construction cost. The filling material for overbreak bottoms of tunnels should be concrete, but concrete and mixed granular materials with fractured rock are also used for some sites. Tunnels in which granular materials with fractured rock are used may have a discontinuous section under the concrete slab track. The discontinuous section influences the propagation of waves generated from train operation. When the bottom of a tunnel is filled with only concrete material, the bottom of the tunnel can be considered as a continuous section, in which the waves generated from a train may propagate without reflection waves. However, a discontinuous section filled with mixed granular materials may reflect waves, which can cause resonance of vibration. The filled materials and vibration propagation characteristics are studied in this research. Tunnel bottom filling materials that have ratios of granular material to concrete of 5.0 %, 11.5 %, and 18.0 % are investigated. Samples were made and tested to determine their material properties. Static numerical analyses were performed using the FEM program under train operation load; test results were found to satisfy the stability requirements. However, dynamic analysis results show that some mixed ratios may generate resonance vibration from train operation at certain speeds.

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

Comparison of the SNR in the MR images on dental implant material (치아 임플란트 재료에 따른 자기공명영상의 SNR 비교)

  • Kim, Dong-Hyun;Ko, Seong-Jin;Ye, Soo-Young
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.4
    • /
    • pp.149-155
    • /
    • 2015
  • Tooth implant is located in oral cavity and affects neck, skull base, and facail image. These magnetic inhomogeneities are usually frequency encoding direction which cause artifacts due to change of signal strength and geometric distortion. First, to evaluate signal to noise ratio (SNR) of magnetic resonance image caused by tooth implant this study uses meat phantom which is similar to human body and is consisted with fat, muscle, and water to measure signal to noise ratio. Second, signal to noise ratio by using custom-made fixed phantom is measured, and then signal to noise ratio size of different tooth implant types is compared and analyzed. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for meat phantom were 2.76, 2.22, 1.88, and 1.57 on T1 SE, 1.88, 1.78, 1.65, and 1.79 on T2 FLAIR, 2.28, 2.25, 2.88, and 2.05 on T2 FSE, and 2.74, 1.94, 1.67, and 1.48 on T2 GRE. The measured signal to noise ratio values of Brushite, HSA, Metal, and RBM for fixed water phantom were 1.2, 1.06, 1.12, and 1.22 on DWI, 1.93, 1.87, 1.93, and 2.06 T1 SE, 1.83, 1.76, 1.82, and 1.92 on T2 FLAIR, 1.85, 1.79, 7.86, and 1.97 on T2 FSE, and 1.97, 1.93, 1.99, and 2.06 on T2 GRE. By considering through the results, patients and dentists need to consider some impacts from testing many aspects although their main purpose of having tooth implants is a dental restoration. Moreover, depending on the tooth implant characteristics of individual patients this study results can be used as baseline data when choosing test protocol.

A Study on The Measurement of Cerebral Cortical Thickness in Patients with Mood Disorders (기분장애 환자의 대뇌 피질 두께 측정에 관한 연구)

  • Do-Hun Kim;Hyo-Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2024
  • This study compared the cortical thickness of patients with mood disorders and a control group to assess structural abnormalities. A retrospective study was conducted from September 2020 to August 2022 at the Department of Psychiatry, P Hospital in Yangsan, Gyeongsangnam-do. The study included 44 individuals diagnosed with mood disorders and 59 healthy individuals without any pathological lesions. The 3D-T1 MPRAGE images obtained from magnetic resonance imaging examinations were utilized, and FreeSurfer software was employed to measure cortical thickness. Statistical analysis involved independent samples t-tests to measure the differences in means between the two groups, and Cohen's d test was used to compare the effect sizes of the differences. Furthermore, the correlation between the measured average cortical thickness and Positive and Negative Syndrome Scale scores was analyzed. The research results revealed that patients with mood disorders exhibited decreased cortical thickness compared to the normal control group in both superior frontal regions, both rostral middle frontal regions, both caudal middle frontal regions, both pars opercularis, pars orbitals, pars triangularis regions, both superior temporal regions, both inferior temporal regions, both lateral orbitofrontal regions, both medial orbitofrontal regions, both fusiform regions, both posterior cingulate regions, both isthmus cingulate regions, both superior parietal regions, both inferior parietal regions, both supramarginal regions, left postcentral region, right bank of the superior temporal sulcus region, right middle temporal region, right rostral anterior cingulate region, and right insula region. Among them, regions that showed differences with effect sizes of 0.8 or higher were left fusiform (d=0.82), pars opercularis (d=0.94), superior frontal (d=0.88), right lateral orbitofrontal (d=0.85), and pars orbitalis (d=0.89). Additionally, there was a weak negative correlation between PANSS scores and average cortical thickness in both the left hemisphere (r=-0.234) and right hemisphere (r=-0.230). These findings are expected to be helpful in identifying areas of cortical thickness reduction in patients with mood disorders compared to healthy individuals and understanding the relationship between symptom severity and cortical thickness changes.

Association between Texture Analysis Parameters and Molecular Biologic KRAS Mutation in Non-Mucinous Rectal Cancer (원발성 비점액성 직장암 환자에서 자기공명영상 기반 텍스처 분석 변수와 KRAS 유전자 변이와의 연관성)

  • Sung Jae Jo;Seung Ho Kim;Sang Joon Park;Yedaun Lee;Jung Hee Son
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.2
    • /
    • pp.406-416
    • /
    • 2021
  • Purpose To evaluate the association between magnetic resonance imaging (MRI)-based texture parameters and Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in patients with non-mucinous rectal cancer. Materials and Methods Seventy-nine patients who had pathologically confirmed rectal non-mucinous adenocarcinoma with or without KRAS-mutation and had undergone rectal MRI were divided into a training (n = 46) and validation dataset (n = 33). A texture analysis was performed on the axial T2-weighted images. The association was statistically analyzed using the Mann-Whitney U test. To extract an optimal cut-off value for the prediction of KRAS mutation, a receiver operating characteristic curve analysis was performed. The cut-off value was verified using the validation dataset. Results In the training dataset, skewness in the mutant group (n = 22) was significantly higher than in the wild-type group (n = 24) (0.221 ± 0.283; -0.006 ± 0.178, respectively, p = 0.003). The area under the curve of the skewness was 0.757 (95% confidence interval, 0.606 to 0.872) with a maximum accuracy of 71%, a sensitivity of 64%, and a specificity of 78%. None of the other texture parameters were associated with KRAS mutation (p > 0.05). When a cut-off value of 0.078 was applied to the validation dataset, this had an accuracy of 76%, a sensitivity of 86%, and a specificity of 68%. Conclusion Skewness was associated with KRAS mutation in patients with non-mucinous rectal cancer.

Clinical and Imaging Findings of Neonatal Seizures Presenting as Diffuse Cerebral White Matter Abnormality on Diffusion-Weighted Imaging without any Structural or Metabolic Etiology (확산강조영상에서 미만성 대뇌 백질의 이상을 보이는 신생아 경련 환자에서 구조적 이상이나 대사와 관련된 원인이 없을 경우 임상적 소견과 영상 소견의 특징)

  • Maeran Kim;Jae-Yeon Hwang;Yeoun Joo Lee;Yong-Woo Kim;Shin Yun Byun;Yun-Jin Lee;Jeong A Yeom;Ung Bae Jeon;Ki Seok Choo;Kyung Jin Nam;Storm Nicholas Shaun Reid
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1412-1423
    • /
    • 2020
  • Purpose Some patients with neonatal seizures show diffuse, symmetric diffusion-restricted lesions in the cerebral white matter. The aim of this study was to describe clinical and imaging findings of patients with neonatal seizures who had diffuse, symmetric diffusion-restricted lesions without any structural or metabolic etiology. Materials and Methods A total of 56 neonates aged less than 1 week underwent brain magnetic resonance imaging (MRI) for evaluation of seizures from November 2008 to February 2017. After excluding 43 patients, 13 patients showed diffuse white matter abnormality on diffusion-weighted imaging. Initial and follow-up clinical and MRI findings were analyzed retrospectively. Results All 13 patients were born at full term. Among the ten patients who underwent a stool test for viruses, six were positive for rotavirus and one for astrovirus. MRI revealed diffuse, symmetric diffusion-restricted lesions distributed along the cerebral white matter, thalami, and midbrain variably. Conclusion Diffuse, symmetric diffusion-restricted lesions involving the cerebral white matter can be seen in patients with neonatal seizures without any structural or metabolic etiology. Rotavirus is commonly but not exclusively detected in these patients. Nevertheless, viral infection-associated encephalopathy should be considered for patients with characteristic clinical and MRI findings.

The usefulness of diagnostic tests in children with language delay (언어 발달지연 환아에서 진단적 검사의 유용성)

  • Oh, Seung Taek;Lee, Eun Sil;Moon, Han Ku
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.3
    • /
    • pp.289-294
    • /
    • 2009
  • Purpose : To assess the usefulness of magnetic resonance imaging (MRI), karyotyping, brainstem auditory evoked potential (BAEP), electroencephalogram (EEG), tandem mass screening test, and newborn metabolic screening test in children with language delay for diagnosing underlying diseases. Methods : From January 2000 to June 2007, a retrospective chart review was performed for 122 children with language delay who visited the Child Neurology Clinic at Yeungnam University Hospital and who underwent neuropsychologic tests and other diagnostic evaluations for underlying diseases. They were grouped into phenomenological diagnostic categories, and test results were analyzed according to the underlying diseases. Results : Of 122 patients, 47 (38.5%) had mental retardation, 40 (32.8%) had developmental language disorders, 23 (18.9 %) had borderline IQ, and 12 (9.8%) had autism spectrum disorder. In 26 (21.3%) cases, the causes or relevant clinical findings to explain language delay were found. Eight (10.4%) of 77 MRIs, 6 (8.0%) of 75 EEGs, and 4 (5%) of 80 BAEPs showed abnormal results. Results directly attributed to diagnosing underlying diseases were 2 hearing defects in BAEPs and 1 bilateral perisylvian cortical dysplasia in MRIs. No abnormal results were found in karyotyping, tandem mass screening tests, and new-born screening tests. Conclusion : Commonly used tests to diagnose the cause of language delay are not very effective and should only be used selectively, according to patient characteristics. However, despite the low diagnostic yields from these tests, because many patients show abnormal results, these tests are useful when conducted in complete evaluation.

Relationship between disk displacement of temporomandibular joint and dentofacial asymmetry (측두하악관절 원판 변위와 치열 및 안면부 비대칭의 관계에 대한 연구)

  • Nahm, Kyoung-Soo;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.33 no.3 s.98
    • /
    • pp.211-222
    • /
    • 2003
  • The purpose of this study was to determine whether there is an association between disk displacement of the Temporomandibular Joint (TMJ) and dentofacial asymmetry In orthodontic patients. The subjects consisted of 60 female orthodontic patients between the ages of 18 and 38 years (mean age 23.3 years) who had visited the Department of Orthodontics at Seoul National University Dental Hospital from January 2000 to April 2002. On the basis of magnetic resonance imaging (MRI) of their bilateral TMJs, the subjects were divided Into four groups'. bilateral normal group (twenty-one persons); disk displacement of right TMJ group (six persons); disk displacement of left TMJ group (nine persons); and disk displacement of both TMJs group (twenty-four persons) Postero-anterior (PA) cephalograms and diagnostic models which had been taken before orthodontic treatment were measured. In the linear measurements, a line connecting the right and left Latero-Orbitale (Lo) represented the horizontal reference line (H). The vertical reference line (V) was constructed as a line bisecting and running perpendicular to H. One-way analysis of variance (ANOVA) was used to test whether the mean values of measurements between groups were significantly different. In addition, Bonferronil's multiple comparison test was performed at a level of 0.05. The results were as follows; 1 In the diagnostic model analysis, the overjet, nght molar relationship, and left molar relationship were significantly different among the four groups. 2. In the PA cephalometric analysis, differences in the right and left vertical position of the lower first molar and Ag were significantly dissimilar among the four groups. 3. If the disk displacement of TMJ was present on one side, the ipsilateral ramus was shorter, resulting in asymmetry in the vertical position of Ag. This study indicated that dentofacial asymmetry might be related to the disk displacement of TMJ.