• Title/Summary/Keyword: resolving power

검색결과 170건 처리시간 0.024초

개방된 챔버 입구에서 작동하는 소형 프로펠러 팬 주위의 난류유동해석 (Numerical analysis of turbulent flow around a small propeller fan operating at the inlet of open chamber)

  • 오건제;강신형
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1586-1594
    • /
    • 1997
  • Performance characteristics of a small propeller fan are numerically investigated solving the continuity and Reynolds-averaged Navier-Stokes equations. The Reynolds stresses for turbulent transport are modelled using a k-.epsilon. turbulence model. The present numerical procedure is constructed using the Finite Volume Method with the SIMPLE algorithms. The performance parameters obtained from the calculations are compared with the measured values for the various flow rates. A performance test of the fan shows different characteristics between a radial type at small flow rates and an axial type at large flow rates. Comparisons between the predictions and the measurements show that the predicted results are in good agreement with the measured values and reasonably reproduce the sharp variations of the power and head coefficient around a flow coefficient .PHI.=0.3. These comparisons indicate that the present numerical method is capable of resolving the performance characteristics with reasonable accuracy. At low flow rates, it is found that the flow enters the fan in an axial direction and is discharged radially outward at the tip which happens in the centrifugal fan. The centrifugal effect makes a significant difference in the characteristics of a fan at the low and high values of flow coefficient.

GMM을 이용한 응급 단어와 비응급 단어의 검출 및 인식 기법 (Detection and Recognition Method for Emergency and Non-emergency Speech by Gaussian Mixture Model)

  • 조영임;이대종
    • 한국지능시스템학회논문지
    • /
    • 제21권2호
    • /
    • pp.254-259
    • /
    • 2011
  • 일반적으로 어떤 순간에 발생할지 모르는 응급 상황을 CCTV의 영상 정보만으로 상황을 항상 모니터링하기에는 인력과 비용의문제점이 발생되고 있다. 본 논문에서는 응급상황을 동적으로 보여주는 CCTV환경에서 감지하기 위해 GMM을 이용한 응급단어와 비응급단어의 검출 및 인식기법을제안하고자 한다. 제안된 방법은 Global GMM 모델에 의해 응급단어와 일반단어를 검출하고 이 모델에 의해 응급단어라 판정된 경우에는 Local GMM 모델에 응급단어 인식을 수행하게 된다. 제안된 방법은 다양한 환경하에서 취득한 응급단어와 일반단어에 대해 적용하여 타당성을 검증하였다.

CCTV 응급상황에 따른 지능형 음성인식 시스템 구현 (Implementation of Intelligent Speech Recognition System according to CCTV Emergency Information)

  • 조영임;장성순
    • 한국지능시스템학회논문지
    • /
    • 제19권3호
    • /
    • pp.415-420
    • /
    • 2009
  • 일반적으로 어떤 순간에 발생할지 모르는 응급 상황을 CCTV의 영상 정보만으로 상황을 항상 모니터링하기에는 인력과 비용의문제점이 발생되고 있다. 본 논문에서는 응급상황을 동적으로 보여주는 CCTV환경에서 감지하기 위해 음성인식 기술을 도입하여 문제점을 해결하고자 한다. 이를 위해 본 논문에서는 HMM(Hidden Markov Model) 기반 음성인식을 이용하여, 상황판단의 선택 여부로 고려하였으며, CCTV 환경의 기본적인 잡음 환경은 Wiener 필터를 이용하여 효과적으로 제거하고자 하며, 향후 응급 상황만을 효과적으로 CCTV 관리자에게 제공을 하여 상황인지 하고자 한다.

이중 주파수에 의한 천해 천부지층의 분해력과 투과력에 관한 사고 (Sub-Bottom Profile Analysis Using Dual Frequency Prototype 15/100 KHz)

  • 김소구
    • 한국해안해양공학회지
    • /
    • 제5권2호
    • /
    • pp.143-150
    • /
    • 1993
  • 이중 주파수(Dual Frequency)를 사용한 Prototype형 천해 지층 탐사기를 사용하여 얻은 탐사 기록지가 제시되었다. 이중 주파수로는 3.5/100KHz 혹은 15/100KHz를 이용해서 고주파수에 의한 고해상도(High Resolution)을 얻고 동시에 저주파수(3.5~15KHz)에 의한 심층 투과력을 높이는데 본 연구의 목적이 있다. 특히 탐지하는 목표물이 Fresnel 반경에 비해서 매우 작을 때는 쌍곡선형 회절무늬(Hyperbolic Diffraction)가 나타나기 때문에 쉽게 목표물을 찾을 수 있다. 감쇠상수가 큰 모래층은 작은 감쇠상수를 갖고 있는 점토보다 지진파의 투과력을 약하게 만든다. 이와같이 이중 주파수의 동시 운용은 해저 지질. 모래와 점토(Silt/Clay) 분포 오니토 및 해양고고학 유물 탐사에 크게 활용할 수 있다.

  • PDF

High-Throughput Active Compound Discovery using Correlations between Activity and Mass Profiles

  • Park, Kyu-Hwan;Yoon, Kyo-Joong;Kwon, Kyung-Hoon;Kim, Hyun-Sik
    • Mass Spectrometry Letters
    • /
    • 제1권1호
    • /
    • pp.13-16
    • /
    • 2010
  • The active components in a plant extract can be represented as mass profiles. We introduce here a new, multi-compound discovery method known as Scaling of Correlations between Activity and Mass Profiles (SCAMP). In this method, a correlation coefficient is used to quantify similarities between the extract activity and mass profiles. The method was evaluated by first measuring the anti-oxidation activity of eleven fractions of an Astragali Radix extract using DPPH assays. Next, 15 T Fouriertransform ion cyclotron resonance (FT-ICR) MS was employed to generate mass profiles of the eleven fractions. A comparison of correlation coefficients indicated two compounds at m/z 285.076 and 286.076 that were strong antioxidants. Principal component analyses of these profiles yielded the same result. FT-ICR MS, which offers a mass resolving power of 500,000, was used to discern isotopic fine structures and indicated that the molecular formula corresponding to the peak at m/z 285.076 was $C_{16}H_{13}O_5$. SCAMP in combination with high-resolution MS can be applied to any type of mixture to study pharmacological activity and is a powerful tool for active compound discovery in plant extract studies.

SWRF를 이용한 전시영상의 MTF 측정 (Measurement of MTF in Display image on monitor by SWRF)

  • 김창복;이경섭;김영근;조수영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집
    • /
    • pp.15-17
    • /
    • 2004
  • The quality of X -ray image is depending on the acquired signal pattern So far, the MTF(modulation transfer function) of medical image system has been obtained through various kinds of calculationprocesses after using SWRF (A square wave response function method) to print out it into films. In this study, a tool has been developed that can help the actual user who actually creates the medical images measure the MTF of the finaldisplay image very simply by applying Borland C++ builder software as well as LEAD tools software for the SWRF calculation process to analyze the MTF even on the display image. Films have been printed out by this newly developed MTF measuring tool under the same conditions with the ones for the existing tools and also the calculation method has shown no difference with any existing SWRF calculation method. By using this, it was found out that the MTF of the resolving power of the computed radiography(CR) Image plate (IP) that is a conventional X-ray detection system Jar the conventional X-ray purpose was about 10% at the range of 3.00 LP/mm.

  • PDF

카메라폰 렌즈의 MTF 측정장치 개발 (Development of an Equipment for measuring the MTF of Camera Phone Lenses)

  • 홍성목;조재흥;이윤우;이회윤;양호순;이인원
    • 한국광학회지
    • /
    • 제18권1호
    • /
    • pp.31-36
    • /
    • 2007
  • 직경과 초점거리가 수 mm인 카메라폰 렌즈의 성능을 평가하는 변조전달함수(Modulation Transfer Function: MTF) 측정장치를 개발 하였다. 전체 측정장치는 물체부, 상분석부, 렌즈 마운터로 구성되며, 물체부는 비축상 측정을 위하여 회전한다. 렌즈의 정밀한 정렬을 위하여 정밀한 수평형 거치대를 제작하였으며 광축 조정과 렌즈의 기울어짐 등의 문제를 매우 효과적으로 개선하였다. 시험렌즈의 초기정렬이 끝나면 자동으로 MTF를 측정하며 측정시간은 10초 이내이다.

Wafer-to-Wafer Integration을 위한 생산수율 챌린지에 대한 연구 (Manufacturing yield challenges for wafer-to-wafer integration)

  • 김사라은경
    • 마이크로전자및패키징학회지
    • /
    • 제20권1호
    • /
    • pp.1-5
    • /
    • 2013
  • 3D integration 기술 특히 W2W integration 기술은 전자산업의 디바이스 scaling 문제를 해결하고 고성능화 소형화 추세에 맞춘 가장 핵심적인 기술 방향이다. 그러나 W2W integration 기술은 현재 가격과 생산수율의 장애를 가지고 있고, 이를 해결하기 위해서 웨이퍼 매칭, 리던던시, 다이 면적 축소, 배선 층 수 축소와 같은 디자인 연구들이 진행되고 있다. W2W integration 기술이 대량생산으로 연결되기 위해서는 우선적으로 웨이퍼 본딩, 실리콘연삭, TSV 배선 공정의 최적화가 이루어져야 하겠지만, 가격을 포함한 생산수율을 높이기 위해서는 반드시 디자인 연구가 선행되어야 하겠다.

The Chemical Abundances of Hypervelocity Stars in the Milky Way Disk

  • Yeom, Bum-Suk;Lee, Young Sun;Kim, Young Kwang;Han, Doo-Ri
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.77.2-77.2
    • /
    • 2016
  • We present preliminary results of the analysis of chemical abundances for seven hypervelocity star (HVS) candidates. These objects are G and K dwarfs in the Galactic disk selected from the Sloan Extension for Galactic Understanding and Exploration. Unlike other HVSs discovered thus far, their stellar orbits and kinematics suggest that they do not originate in the Galactic center or in an accretion event. These factors imply yet-unknown mechanisms that give rise to these kinematically-extreme disk stars. In order to study in detail their progenitors and possible formation mechanisms, we obtained spectra of these stars at a resolving power of R~6000, with the Dual Imaging Spectrograph at the Apache Point Observatory. We derive the abundances of chemical elements, C, Mg, Ca, Ti, Cr, Fe, and Ba from the observed spectra, using MOOG. We compare them with the ones of typical Galactic disk stars and discuss discrepancies between them to search for clues to their origin.

  • PDF

Fast High-throughput Screening of the H1N1 Virus by Parallel Detection with Multi-channel Microchip Electrophoresis

  • Zhang, Peng;Park, Guenyoung;Kang, Seong Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권4호
    • /
    • pp.1082-1086
    • /
    • 2014
  • A multi-channel microchip electrophoresis (MCME) method with parallel laser-induced fluorescence (LIF) detection was developed for rapid screening of H1N1 virus. The hemagglutinin (HA) and nucleocapsid protein (NP) gene of H1N1 virus were amplified using polymerase chain reaction (PCR). The amplified PCR products of the H1N1 virus DNA (HA, 116 bp and NP, 195 bp) were simultaneously detected within 25 s in three parallel channels using an expanded laser beam and a charge-coupled device camera. The parallel separations were demonstrated using a sieving gel matrix of 0.3% poly(ethylene oxide) ($M_r$ = 8,000,000) in $1{\times}$ TBE buffer (pH 8.4) with a programmed step electric field strength (PSEFS). The method was ~20 times faster than conventional slab gel electrophoresis, without any loss of resolving power or reproducibility. The proposed MCME/PSEFS assay technique provides a simple and accurate method for fast high-throughput screening of infectious virus DNA molecules under 400 bp.