• 제목/요약/키워드: resistance detection

검색결과 552건 처리시간 0.031초

지역난방배관의 누수감지 신뢰성 향상에 관한 연구 (A Study on the Improvement of Water-Leakage Detection Reliability in Local Heating System)

  • 신춘식;안영주;변기식
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.66-72
    • /
    • 1999
  • Local heating transportation pipe has sensor and return lines to detect water-leakage. There are impulse and resistance comparison measurement types for a water-leakage detection. The impulse type shows large detection error within a measurement range. Since the resistance comparison type can find a comparative accurate single water-leakage point in the measurement range of heating pipe, it has been used to detect water-leakages these days. However if the multi water-leakages are happened in the measurement range of transportation pipe. the resistance comparison type shows a detection error point by the parallel resistance between a detection sensor line and ground. But the detection error will be minimized by the divided transportation pipe loops. In this research, it suggests the design of remote controlled detection system which can divide a large pipe loop and a possible single water-leakage measurement process in each divided loops.

  • PDF

Damage detection of composite materials via IR thermography and electrical resistance measurement: A review

  • Park, Kundo;Lee, Junhyeong;Ryu, Seunghwa
    • Structural Engineering and Mechanics
    • /
    • 제80권5호
    • /
    • pp.563-583
    • /
    • 2021
  • Composite materials, composed of multiple constituent materials with dissimilar properties, are actively adopted in a wide range of industrial sectors due to their remarkable strength-to-weight and stiffness-to-weight ratio. Nevertheless, the failure mechanism of composite materials is highly complicated due to their sophisticated microstructure, making it much harder to predict their residual material lives in real life applications. A promising solution for this safety issue is structural damage detection. In the present paper, damage detection of composite material via electrical resistance-based technique and infrared thermography is reviewed. The operating principles of the two damage detection methodologies are introduced, and some research advances of each techniques are covered. The advancement of IR thermography-based non-destructive technique (NDT) including optical thermography, laser thermography and eddy current thermography will be reported, as well as the electrical impedance tomography (EIT) which is a technology increasingly drawing attentions in the field of electrical resistance-based damage detection. A brief comparison of the two methodologies based on each of their strengths and limitations is carried out, and a recent research update regarding the coupling of the two techniques for improved damage detection in composite materials will be discussed.

전기저항 측정기법을 이용한 오염물질 누출감지시스템의 개발: II. 현장모형시험을 통한 매립지에의 적용성 평가 (Development of Contaminant Leakage Detection System Using Electrical Resistance Measurement: ll. Evaluation of Applicability for Landfill Site by Field Model Tests)

  • 오명학;이주형;박준범;김형석;강우식
    • 한국지반공학회논문집
    • /
    • 제17권6호
    • /
    • pp.225-233
    • /
    • 2001
  • 본 논문에서는 격자망식 전선배치에 의한 침출수 누출감지시스템을 개발하기 위하여 현장모형시험을 통하여 적용성을 평가하였으며, 전기회로시험을 통하여 격자망 전선 배치에서 발생하는 전기회로적 효과를 파악하고자 하였다. 침출수는 전기저항을 감소시키기 때문에 누출지점에서는 다른 지점에 비해 낮은 전기저항값을 나타내었다. 따라서, 전기저항을 측정하는 본 누출감지시스템에 의하여 임의 지점에서 발생하는 침출수의 누출 감지가 가능하였으며, 평면적 분포도를 통하여 누출위치의 파악이 가능하였다. 전기저항이 감소된 지점과 동일한 전선상에 위치한 다른 센서에 서의 측정값도 약간 감소하는 경향을 나타내었으나, 이는 저항이 작은 곳으로 전류의 흐름이 발생하는 전기회로적 효과로 설명할 수 있었다.

  • PDF

전기저항 측정에 의한 FRP의 파괴 예측 기능의 평가 (Evaluation of Fracture Detection Function for the FRP by Electrical Resistance Measurement)

  • 신순기;김영희;이준희
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.135-139
    • /
    • 2002
  • Carbon powders (CP) and carbon fiber (CF) were introduced info glass fiber reinforced plastics (FRP) composites to obtain fracture detection function. The composites were evaluated through the relation between a load-displacement curve and an electrical resistance change curve in three point bending test. CP containing FRP (CP-FRP) has a sensitivity of electrical resistance change at much lower load level than CF containing FRP (CF-FRP). In loading-unloading tests, CP-FRP showed a large amount of residual electrical resistance which enables the estimation of loading hysteresis.

Fatigue damage detection of CFRP using the electrical resistance change method

  • Todoroki, Akira;Mizutani, Yoshihiro;Suzuki, Yoshiro;Haruyama, Daichi
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제14권4호
    • /
    • pp.350-355
    • /
    • 2013
  • Electrical resistance change measurements were performed, to detect fatigue damage of a quasi-isotropic CFRP and cross-ply CFRP laminates. A four-probe method was used to measure the exact electrical resistance change. A three-probe method was used to measure the electrical contact resistance change, during long cyclic loading. The specimen side surface was observed using a video-microscope to detect damage. The measured electrical resistance changes were compared with the observed damage. The results of this study show that the electrical resistance increase of the quasi-isotropic laminate was caused by a delamination crack between ${\pm}45^{\circ}$ plies. Matrix cracking caused a small electrical resistance increase of the cross-ply laminate, but the decreased electrical resistance caused by the shear-plastic deformation impedes matrix-cracking detection.

Damage Detection in Fiber Reinforced Composites Containing Electrically Conductive Phases

  • Shin, Soon-Gi;Hideaki Matsubara
    • The Korean Journal of Ceramics
    • /
    • 제6권3호
    • /
    • pp.201-205
    • /
    • 2000
  • Fiber reinforced plastic (FRP) composites and ceramic matrix composites (CMC) which contain electrically conductive phases have been designed and fabricated to introduce the detection capability of damage/fracture detection into these materials. The composites were made electrically conductive by adding carbon and TiN particles into FRP and CMC, respectively. The resistance of the conductive FRP containing carbon particles showed almost linear response to strain and high sensitivity over a wide range of strains. After each load-unload cycle the FRP retained a residual resistance, which increased with applied maximum stress or strain. The FRP with carbon particles embedded in cement (mortar) specimens enabled micro-crack formation and propagation in the mortar to be detected in situ. The CMC materials exhibited not only sensitive response to the applied strain but also an increase in resistance with increasing number of load-unload cycles during cyclic load testing. These results show that it is possible to use these composites to detect and/or fracture in structural materials, which are required to monitor the healthiness or safety in industrial applications and public constructions.

  • PDF

Detection of Delamination Crack for Polymer Matrix Composites with Carbon Fiber by Electric Potential Method

  • Shin, Soon-Gi
    • 한국재료학회지
    • /
    • 제23권2호
    • /
    • pp.149-153
    • /
    • 2013
  • Delamination crack detection is very important for improving the structural reliability of laminated composite structures. This requires real-time delamination detection technologies. For composite laminates that are reinforced with carbon fiber, an electrical potential method uses carbon fiber for reinforcements and sensors at the same time. The use of carbon fiber for sensors does not need to consider the strength reduction of smart structures induced by imbedding sensors into the structures. With carbon fiber reinforced (CF/) epoxy matrix composites, it had been proved that the delamination crack was detected experimentally. In the present study, therefore, similar experiments were conducted to prove the applicability of the method for delamination crack detection of CF/polyetherethereketone matrix composite laminates. Mode I and mode II delamination tests with artificial cracks were conducted, and three point bending tests without artificial cracks were conducted. This study experimentally proves the applicability of the method for detection of delamination cracks. CF/polyetherethereketone material has strong electric resistance anisotropy. For CF/polyetherethereketone matrix composites, a carbon fiber network is constructed, and the network is broken by propagation of delamination cracks. This causes a change in the electric resistance of CF/polyetherethereketone matrix composites. Using three point bending specimens, delamination cracks generated without artificial initial cracks is proved to be detectable using the electric potential method: This method successfully detected delamination cracks.

EKF를 이용한 BLDC 모터 구동기 인버터의 고장 검출 및 분리 (Fault Detection and Isolation for the Inverter of BLDC Motor Drive using EKF)

  • 김선기;성상만;강기호
    • 제어로봇시스템학회논문지
    • /
    • 제20권7호
    • /
    • pp.706-712
    • /
    • 2014
  • The inverters used to drive Brushless DC motors (BLDC) include switching devices such as FETs and the faults in FETs cause severe performance degradation in systems where a BLDC acts as actuator. This paper presents a fault detection and isolation method for the FETs of an inverter for BLDC motor control systems, which is based on the EKF (Extended Kalman filter). Firstly, an equivalent circuit model for a BLDC motor plus its inverter system was derived. Secondly, a state-space equation was established, where the on-resistance of the FETs is expressed as a state variable and the EKF equation estimates the on-resistance. If the estimated resistance differs greatly from the known value, it can be asserted that there is a fault on that FET. Thirdly, the local convergence of the established EKF was proved. Finally, through the experiments, the performance of the proposed method was verified. The results show that the on-resistance is estimated close to the value specified in the FET data sheet in normal operation, whereas the estimated resistance is a much larger value than the normal one in case an FET fault occurs. Therefore, it is confirmed that the proposed fault detection and isolation method works appropriately in real systems.

Detection of Colletotrichum spp. Resistant to Benomyl by Using Molecular Techniques

  • Dalha Abdulkadir, Isa;Heung Tae, Kim
    • The Plant Pathology Journal
    • /
    • 제38권6호
    • /
    • pp.629-636
    • /
    • 2022
  • Colletotrichum species is known as the major causal pathogen of red pepper anthracnose in Korea and various groups of fungicides are registered for the management of the disease. However, the consistent use of fungicides has resulted in the development of resistance in many red pepper-growing areas of Korea. Effective management of the occurrence of fungicide resistance depends on constant monitoring and early detection. Thus, in this study, various methods such as agar dilution method (ADM), gene sequencing, allele-specific polymerase chain reaction (PCR), and polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) were applied for the detection of benzimidazole resistance among 24 isolates of Colletotrichum acutatum s. lat. and Colletotrichum gloeosporioides s. lat. The result of the ADM showed that C. gloeosporioides s. lat. was classified into sensitive and resistant isolates to benomyl while C. acutatum s. lat. was insensitive at ≥1 ㎍/ml of benomyl. The sequence analysis of the β-tubulin gene showed the presence of a single nucleotide mutation at the 198th amino acid position of five isolates (16CACY14, 16CAYY19, 15HN5, 15KJ1, and 16CAYY7) of C. gloeosporioides s. lat. Allele-specific PCR and PCR-RFLP were used to detect point mutation at 198th amino acid position and this was done within a day unlike ADM which usually takes more than one week and thus saving time and resources that are essential in the fungicide resistance management in the field. Therefore, the molecular techniques established in this study can warrant early detection of benzimidazole fungicide resistance for the adoption of management strategies that can prevent yield losses among farmers.