• Title/Summary/Keyword: resin duct

Search Result 31, Processing Time 0.023 seconds

The Variation of Isoenzymes and Morphological Characteristics of Needle, Cone and Seed According to Resin Duct Index in Pinus densiflora and Pinus thunbergii (소나무 및 곰솔의 수지구지수(樹脂溝脂數)에 따른 침엽(針葉), 구과(毬果) 및 종자(種子)의 형태적(形態的) 특성(特性)과 동위효소(同位酵素)의 변이(變異))

  • Son, Doo Sik;Park, Sang Jun;Hwang, Jae Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.4
    • /
    • pp.424-430
    • /
    • 1990
  • The variation of needle, cone and seed characteristics and of allelic frequency in isoenzyme, ADH, ME and PGI, according to different resin duct index in Pinus densiflora, Pinus thunbergii and their hybrids was analyzed. The results obtained were as follows : 1. With increase of number of resin ducts, morphological characteristics such as needle length, needle sheath length, cone size, seed size, seed wing size, 1000 seeds weight, etc. tended to he increased, while number of stomata row in needle to be decreased. 2. As the results of discriminant analysis for the morphological characteristics of needle, cone and seed, most individuals are generally coincided with number of resin duct mostly in Pinus densiflora were not. 3. According to the canonical discriminant function obtained from the morphological characteristics in Pinus densiflora, Pinus thunbergii and their hybrids including introgressive hybrid, the resin duct index, 1000 seeds weight, cone size and neelde sheath length characterized fairly their species. 4. With increase of resin duct index, hybrid index tended to be higher. The results obtained from the discriminant analysis and the hybrid index were nearly same each other. 5. With increase of number of resin duct, the allelic frequencies for isoenzyme, ADH-$B_2$, ME-$A_2$ and PGI-$B_1$. $B_2$ tended to increase but those of ADH-$B_3$, ME-$A_4$, and PGI-$B_3$, to decrease. It is thought that this increase of frequency for the former four isoenzymes was resulted in introgressive gene flow from Pinus thunbergii to Pines densiflora and accordingly the frequency of latter three isoenzymes tended to decrease.

  • PDF

Surface Ageing Property of Polymer Insulator for Transmission line with Forest Fire Test (H종 주상용 몰드 변압기의 덕크구조에 따른 열해석 특성)

  • Cho, Han-Goo;Kim, Kyang-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.111-111
    • /
    • 2010
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. In this paper, the temperature distribution and thermal stress analysis of H class 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

Identification of Root Age by Histochemical Staining of Secretory Duct Layers in Ginseng (인삼 분비도관의 조직화학적 염색에 의한 연근판별)

  • 이경환;이성식;이명구;김은수
    • Journal of Ginseng Research
    • /
    • v.25 no.2
    • /
    • pp.101-105
    • /
    • 2001
  • Identification of the age of ginseng root is very important in commercial market as well as in research field. However, any criterion abut it has not been clearly established yet. We studied to find a clear morphological key for identification of ginseng root\\`s age using the histochemical staining method. Fresh sections of 3, 4, 5, and 6 year old roots were stained with 1% nile blue, observed under the light microscopy, and compared each other. The number of secretory duct layers(SDL) is a useful key to confirm the age of ginseng root as follow; three-year-old root has two, four-year-old one has three, fie-year-old one has four, and six-year-old one has five resin duct layers on each cortical region of roots. Secretory ducts are thought to be formed by the vascular cambium every year. Unlike the surrounding parenchyma cells, secretory epithelial cells lack starch grains in the cytoplasm.

  • PDF

Variation in Needle Morphology of Natural Populations of Abies nephrolepis Maxim. and A. Koreana Wilson in Korea (분비·구상나무 천연집단(天然集團)의 침엽특성(針葉特性) 변이(變異))

  • Song, Jeong-Ho;Lee, Jung-Joo;Lee, Kab-Yeon;Lee, Jae-Cheon;Kim, Young-Yul
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.4
    • /
    • pp.387-392
    • /
    • 2007
  • Characteristics of needle morphology and anatomy were examined in 14 populations of Abies nephrolepis (Trautv.) Maxim. and A. koreana Wilson. Additionally we studied the classification index to distinguish between the species by the method of discriminant analysis. Characteristics of needle for A. nephrolepis could be distinguished from those for A. koreana by flatten arrangement, thin and long length for needle form, many stomata row, and marginal position of resin duct Nested ANOVA showed that there were statistically significant differences among populations as well as among individuals within populations in all 9 needle traits. For the needle indices such as needle thickness, number of stomata row, and the distance between resin duct and vascular for both species, variance components among populations were larger than those among individuals within populations. The characteristics that contributed most to the separation of A. nephrolepis and A. koreana according to the discriminant analysis using stepdisc procedures were needle index and thickness of needle, needle arrangement index, distance between resin duct and vascular, and number of stomata row.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구)

  • 조한구;이운용;박영두
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드변압기의 덕트에 따른 열해석 특성 연구)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1135-1138
    • /
    • 2003
  • The transformer is major equipment in power receiving and substation facilities. Necessary conditions required for the transformer are compactness, lightness, high reliability, economic advantages, and easy maintenance. The pole-mount transformer installed in distribution system is acting direct role in supply of electric power and it is electric power device should drive for long term. Most of modem transformer are oil-filled transformer and accident is happening considerable. The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. One body molding transformer needs some cooling method because heat radiation between each winding is difficult. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

  • PDF

The Temperature Distribution Analysis of Mold transformer (100kVA 주상용 몰드 변압기의 온도분포 해석)

  • Cho, Han-Goo;Lee, Un-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.125-129
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by FEM(finite element method) to analyze winding temperature rise. In this paper, the temperature distribution and thermal stress analysis of 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

An Analysis of Morphological Variation in Abies koreana Wilson and A. nephrolepis (Traut.) Maxim. of Korea (Pinaceae) and Their Phylogenetic Problems (한국산(韓國産) 분비나무와 구상나무의 형질분석(形質分析)과 종간유연관계(種間類緣關係))

  • Chang, Chin-Sung;Jeon, Jeong Ill;Hyun, Jung Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.86 no.3
    • /
    • pp.378-390
    • /
    • 1997
  • Ten total populations of Korean fir (Abies koreana Wilson) and Manshurian fir [A. nephrolepis (Traut.) Maxim.] were sampled from south Korea to investigate patterns of intraspecific variation in these species and to evaluate a recognition of the two species. Principal components analysis and cluster analysis were performed both on seed-cone data and on needle morphology data. The characters that contributed most to the separation between A. koreana and A. nephrolepis along three principal components axis were leaf width, length of seed, width of seed wing, length of seed wing, cone width, width of scale, and length of bract tip, but these characters were not diagnostic because of overlap in reality. Therefore, all these characters were not reliable in distinguishing these two taxa including bract position (exerted and recurved vs. exerted and straight). The individuals of A. koreana from Mt. Chi-ri appeared quite unique probably on account of its larger cone size and longer scale tip, while those from Mt. Hal-la of A. koreana were generally distinct from others in terms of their larger seed and seed wing and longer scale width. The Mt. Duk-yu specimens of A. korecana appeared somewhat smaller but more data were needed due to the small sampling size. Generally, the gradual clinal geographic trends made evident by the position of resin ducts in leaves of A. koreana can be detected. The southern populations, Mt. Hal-la (an insular population) were generally distinct from the northern populations (Mt. Chi-ri, Mt. Ga-ya and Mt. Duk-yu) in terms of their position of resin duct (medial, within mesophyll vs marginal, close to epidermis : 100% vs 75 or 50%). Although no sharp boundary separating these two species could be detected based on cone and needle morphology, the observed clinal pattern was distinct in northern populations of A. koreana and southern population of A. nephrnlepis. In a preceding study of the flavonoids variation of 20 species in eastern Asia, flavanone (5-deoxyflavanone) was found to be characteristic of A. faxoniana Rehder et Wilson, A. georgei Orr of China and A. koreana of Korea. A. faxoniana, which is assumed to be primitive species, has position of resin duct relative to both the medial and the marginal, while A. georgei and A. koreana are identified by marginal position of resin duct. With respect of foliar flavonoids chemistry, A. koreana was distinct from A. nephrolepis : the southmost samples (Mt. Hal-la and Mt. Chi-ri) contained additional flavonoids derivatives (mainly flavanone) that were not found in the northmost samples of A. nephrolepis except a few individuals from Mts. Seo-rak and Tae-bak populations of Kwang-won province. The presence of A. koreana type flavonoids in two Chinese species suggested that position of resin duct may be a phyletic character. Abies koreana including two Chinese taxa, exhibited the most elaborate and specialized flavonoids profile within the Abies in eastern Asia. Contrary to our initial expectations, the apparent intermediates between A. nephrolepis and A. koreana in Duk-yu and Ga-ya mountains were found. The pattern of variation on position of resin duct and flavonoids chemistry in these populations of A. kareana suggested that genetic interchange or natural hybridization had occurred between these two species. The evidence needed to resolve the status of this taxon is still inconclusive in our opinion until intermediate individuals from Mts. Duk-yu and Ga-ya show indication of hybridization between the two species.

  • PDF

Flow Analyses in the Bifurcated Duct with PIV System and Computer Simulation (입자영상유속계와 컴퓨터 시뮬레이션을 이용한 분기관내 유동해석)

  • Sub, Sang-Ho;Choi, Yul;Roh, Hyung-Woon;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.123-130
    • /
    • 1999
  • The objective of the current study is to understand steady 3-dimensional flow phenomena in a bifurcated duct experimentally. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. The gray level cross-correlation method is applied to the image processing algorithm. The subpixel and the area interpolation methods are used to obtain the final velocity vectors. The finite volume predictions are used to analyze the flow patterns in the bifurcation model. The results of the computer simulation and the PIV experiment for three-dimensional flow show the recirculation zone and the formation of the paired secondary flow distal to the apex of the bifurcation model. The results obtained with the two methods also show that the branch flow strongly strikes the inner wall due to the inertial effect and accompanied helical motion as it flows toward the outer wall.