• Title/Summary/Keyword: residential fire

Search Result 191, Processing Time 0.03 seconds

A Basic Study on the Fire Flame Extraction of Non-Residential Facilities Based on Core Object Extraction (핵심 객체 추출에 기반한 비주거 시설의 화재불꽃 추출에 관한 기초 연구)

  • Park, Changmin
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.13 no.4
    • /
    • pp.71-79
    • /
    • 2017
  • Recently, Fire watching and dangerous substances monitoring system has been being developed to enhance various fire related security. It is generally assumed that fire flame extraction plays a very important role on this monitoring system. In this study, we propose the fire flame extraction method of Non-Residential Facilities based on core object extraction in image. A core object is defined as a comparatively large object at center of the image. First of all, an input image and its decreased resolution image are segmented. Segmented regions are classified as the outer or the inner region. The outer region is adjacent to boundaries of the image and the rest is not. Then core object regions and core background regions are selected from the inner region and the outer region, respectively. Core object regions are the representative regions for the object and are selected by using the information about the region size and location. Each inner region is classified into foreground or background region by comparing its values of a color histogram intersection of the inner region against the core object region and the core background region. Finally, the extracted core object region is determined as fire flame object in the image. Through experiments, we find that to provide a basic measures can respond effectively and quickly to fire in non-residential facilities.

A Study for Thermal Mechanism of Residential Combustibles with Numerical Modeling (주거공간 단위가연물의 열역학적 수치해석 모델링에 관한 연구)

  • Ahn, Chan-Sol;Kim, Jung-Yup;You, Yong-Ho;Kweon, Oh-Sang;Joo, Sang-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.58-63
    • /
    • 2011
  • This study is intended to present a computational thermal model for the combustibles in a residential building. As the Performance Based Design is more popular, fire-intensity and fire-load have turned out to be very important factors for building design and can be predicted through some computational work. To predict and estimate the thermal properties of the residential combustible fire, we made some numerical models of combustibles in a residential building. In a bid to validate the estimate values, computational analysis results from numerical models were compared with real fire tests. For computational analysis, the Fire Dynamics Simulator was used with Large Eddy Simulation model for turbulence. Consequently, each heat release rate and total heat release curves were successfully estimated.

A Study on the Increase Installation of Sprinkler System in Residential Occupancies (주거용 스프링클러설비 설치의 확대에 관한 연구)

  • Jeong, Hyun-Gyu;Song, Yong-Sig;Lee, Jun-Suk;Cho, Won-Chol;Lee, Tae-Shik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.522-525
    • /
    • 2007
  • This study is for reduce the damage of human life and property occurred by a fire in the normal house and market according to increase rate of a fire. this is focused on the present domestic code about prevent a fire and sprinkler system in residential occupancies.

  • PDF

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

An Investigation on the Existing Literature to Prevent Fire Spread of High-rise Buildings (고층 건축물의 화재확대방지를 위한 기존 문헌 조사)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.102-103
    • /
    • 2021
  • In Korea, starting with the Busan residential-commercial fire in 2010, the frequency of fire expansion in high-rise buildings has been continuously increasing. In the case of such large-scale fires, most of the fires generated from the inside tend to expand to the upper floors by riding the exterior material or exterior wall panels through the process of being ejected to the outside. It has been revised so that combustible exterior materials cannot be used in buildings. However, due to the legal fluoride level, the fire risk of high-rise buildings is still high, such as the case of a 33-story residential-commercial fire in Ulsan. In order to prevent such fire expansion, it is considered that it is necessary to first understand the nature of the fire occurring inside and the mechanism of the fire expansion in the upper floor. The purpose of this study is to propose improvements in domestic fire safety design through a review of existing literature to prevent fire expansion of high-rise buildings.

  • PDF

A Study on the Fire Safety of Residential Facility Considering Grenpel Tower Fire (그렌펠 타워 화재를 고려한 주거시설 화재안전에 관한 연구)

  • Lee, Kyu-Min;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • Recently, The Building has became high rising and large scaling according to development of economy in domestic and other country, also the building has increased a variety of functions of insulation for warmth. and it has a symbol of economic growth, but it has risk factor for disasters such as fire. this hazards include not only general building but also residential building. Recently, Grenfell Fire that occurred in England has increased in combustion to the 24th floor of the 1st floor for 1 hour. it resulted in 80 deaths and 79 missing persons. In this study we suggest basic data of residential building for fire safety design related to domestic environment to analyze the problem of Grenfell Tower.

  • PDF

A Study on the Risks Factors of Fire Occurrence and Expansion for Traditional Markets (전통시장 화재 발생 및 확대 위험요인에 관한 연구)

  • Kim, Jung-Gon;Park, Chang-Il;Jung, Jae-Wook;Kim, Seong-Gon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2021
  • Purpose: Traditional markets often have irregular space utilization patterns because the spaces are created and divided as time passed. Internally, there is high risk of fire due to problems such as aging facilities and high-density of stores and externally, there is high risk of fire spread since it is often adjacent to deteriorated residential and commercial facilities. Method: In this paper, on-site investigations were carried out to check fire risk factors and fire spread risk, and fire occurrence and expansion risk factors were investigated for traditional markets in Hwanghak-dong and Dong-daemun by using large-scale fire data from existing traditional markets. Result: As a result of the analysis, there are likely to be various problems such as high fire load and lack of safety awareness due to aging facilities and high-density of stores. In particular, it is necessary to prepare countermeasures because deteriorated residential facilities with narrow alleys around traditional markets have high fire spread. It is situation that while traditional markets mainly are managing for fire and disaster centering on the merchant association, the surrounding residential areas are not properly managed. Conclusion: It is necessary to manage deteriorated residential facilities with traditional markets, also to be linked early warning system and information to evacuate rapidly in case of fire there.

A Study on the combustible materials Combustion Characteristics in residential facilities fire behavior prediction (주거시설 화재성상예측을 위한 가연물 연소특성에 관한 연구)

  • Kim, Dong Eun;Kim, Gi Hyeon;Seo, Dong Goo;Kwon, Young Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.103-104
    • /
    • 2013
  • As a result of experimenting 6 loading combustibles in domestic residential facilities by using Furniture Calorimeter, values of 2,391.26kW were appeared from sofas, 1,891.80kW from drawers, 1,778.95kW from mattress, 1,104kW from chairs, 291kW from tables, and 135.09kW from TV. Also, if applying α value of fire growing rate by classifying fire- growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), mattress can be defined as Ultra-Fast, sofa and drawers Fast, TV Slow, tables Slow, and chairs Medium.

  • PDF

A Study on the Development of the Photo-electric Single Station Smoke Alarm of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력의 광전식 단독경보형감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • This is a case report of a photo-electric single station alarm for residential fire prevention. The detector was developed for the certification in Japanese market which is more than 100 times bigger than Korean market. A comparison and review for test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively is also conducted. The detector alarms with a buzzer and an indicating LED. Operating period and time in alarm, low battery and fire situation is stated. The electronics circuit part to reduce its current and the detector's characteristics are described. It is explained that the measured current and experimental result of the battery discharge can meet the 10 years operation.

A Study on the make Fire Scenario for Residential Facility Combustible Materials

  • Kim, Dong-Eun;Lee, Dong-Yeol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.137-143
    • /
    • 2021
  • In the case of residential facilities, general fire scenarios cannot be applied. Becauseit is difficult to quantify due to the types of combustibles and various fire loads. Existing research conducting surveys of combustibles, but research on fire characteristics is insufficient. Therefore, in this study, an Excel macro that can be quantified by experimenting with the HRR experiments of sofa, drawer, mattress, chair, desk and TV, which are typical combustibles. As a result of experimenting 6 loading combustibles in domestic residential facilities by using a furniture calorimeter, values of 2,391.26kW appeared from the sofa, 1,891.80kW from the drawer, 1,778.95kW from the mattress, 1,104kW from the chair, 291kW from the desk, and 135.09kW from the TV. Also, by applying the α value of the fire growth rate by classifying fire-growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), the mattress can be defined as Very Fast, the sofa and drawer Fast, the TV Slow, the desk Slow, and the chair Medium.