• 제목/요약/키워드: residence IT system

검색결과 252건 처리시간 0.026초

자유수면습지의 잔재물층에 의한 하천수 질소제거 비교 (Comparison of Nitrogen Removal in Free Water Surface Wetlands Purifying Stream Water with and without Litter Layer on its Bottom)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제11권6호
    • /
    • pp.120-129
    • /
    • 2008
  • Removal rate of $NO_3-N$ and TN in a free water surface wetland system with litter layer on its bottom was compared with that without one. The system was established on floodplain in the down reach of the Gwangju Stream in 2001. Its dimensions were 31 meters in length and 12 meters in width. Water of the stream was funneled into it and its effluent was discharged back into the channel. Average litter layer of 9.6 cm was formed on its bottom in 2007. The layer and above-ground parts of reeds and cattails on the system were eliminated in Spring 2008. Volumes and water quality of inflow and outflow of the system were analyzed from May to November in 2007 and 2008, respectively. Inflow into the system both in 2007 and 2008 averaged approximately $40m^3/day$ and hydraulic residence time both in 2007 and 2008 was about 1.5 days. Average influent $NO_3-N$ concentration in 2007 and 2008 was 2.16 and 2.05 mg/L, respectively and influent TN concentration in 2007 and 2008 averaged 3.98 and 3.89 mg/L, respectively. With a 0.05 significance level, effluent temperatures, influent concentrations of $NO_3-N$ and TN, and stem numbers per square meter and height of the emergent plants showed no difference between the system with litter layer and without one. $NO_3-N$ removal in the system with litter layer and without it averaged 55.59 and 46.06%, respectively and TN retention averaged 57.24 and 48.97%, respectively. Both $NO_3-N$ and TN abatement rates in the system with litter layer were significantly high (p < 0.001) when compared with those without one. The wetland system having litter layer on its bottom was more efficient for $NO_3-N$ and TN retention than that without one.

실시간 입자분포 측정을 위한 Radial Exhaust Multi-port System의 개발 및 성능평가 (Development and Performance Evaluation of Radial Exhaust Multi-port System for Real-time Particle Size Distribution Measurement)

  • 이홍규;이양우;전기수;안강호
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.133-137
    • /
    • 2013
  • Measuring particle size distribution is one of the primary concerns in aerosol studies. For a nano-particle size distribution measurement, many scientists use a combination of a differential mobility analyzer (DMA) and a condensation particle counter (CPC) system, which is a called scanning mobility particle sizer (SMPS). Although it has a very high particle size resolution, some issues still remain. These problems include residence time between a DMA and a CPC, discontinuity of a CPC, and disturbance due to long scanning time during the precise measurement of particles. In particular, long scanning time is not adequate for measuring particle size distribution since the particle concentration is changing during the measurement. In this study, we developed radial exhaust multi-port system (REM-system) with no scanning time and high resolution to measure real-time particle size distribution. As a result of the REM-system performed using mono-disperse particle, it is expected that this system will be suitable for measuring continuously changing aerosol. If the counting efficiency of multi-condensation particle counter (M-CPC) and data inversion matrix are completed, REM-system will be a very adequate system for unsteady aerosol, which changes for SMPS scanning time.

북한이탈주민의 한국의료서비스 신뢰에 대한 결정요인 (Determinants of North Korean Refugees' Trust in South Korea Health Service)

  • 엄태림;민하주;이태호;이은주;진기남
    • 보건행정학회지
    • /
    • 제28권1호
    • /
    • pp.70-76
    • /
    • 2018
  • Background: The purpose of this study was to investigate the determinants of North Korean refugees' trust in South Korea health service. Methods: This study surveyed 168 North Korean refugees aged 19 and over living in Seoul, Gyeonggi, Incheon, and Gangwon. The collected data were analyzed by frequency analysis, t-test, analysis of variance, and hierarchical regression analysis to analyze the effect on the trust of refugees. Results: The difference analysis showed statistically significant difference according to duration of residence and employment status. The determinants of North Korean refugees' trust in South Korea health services were duration of residence, basic communication skills, health communication skills, and experience of health service. Conclusion: In order to increase the trust of North Korean defectors in South Korea medical services, it is necessary to resolve communication problems and improve the satisfaction of health services. For this, the interpreter service should be activated. And specific education should be given to the North Korean refugees about the health care system and the utilization methods of health service in Korea.

오마하 시스템 가이드라인의 스마트폰 애플리케이션 개발 (Developing a Smart Phone Application for the OMAHA System Guidelines)

  • 홍해숙;이인근;홍성정;김화선
    • 지역사회간호학회지
    • /
    • 제21권4호
    • /
    • pp.512-521
    • /
    • 2010
  • Purpose: The remarkable progress in information and communication technology has had a great effect on the healthcare delivery system. The development of smart phone applications is a new field. The aim of our research was to provide assistance in developing smart phone applications for community health nursing. Methods: Based on an informative approach, this study developed persona and site maps, followed by a storyboard as a way of analyzing users' requirements and designing responses in the context of smart phone application development methodology. Results: We developed persona, user interface and database design successfully, and then seven nurses selected four nursing problems (income, residence, pain, and digestion hydration). The search time in seconds for the 2005 English OMAHA guidelines to find three nursing interventions for these problems was used to evaluate the effectiveness of the smart phone application. The results showed that smart phone applications' search was 21 times faster on the average than book guidelines. Conclusion: An English version of the OMAHA system application was developed for the Android smart phone market. It is hoped that smart phone applications such as this will be used internationally for nursing education.

주거자 만족도를 고려한 주택 에너지관리 시스템의 부하제어 방법 연구 (A Study on Load Control Method for Home Energy Management System (H-EMS) Considering the Human Comfort)

  • 전정표;김광호
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1025-1032
    • /
    • 2014
  • The effective energy management method will provide the significant advantage to the residential customers under real time pricing plan since it can reduce the electricity charge by controlling the energy consumption according to electricity rate. The earlier studies for load management mainly aim to minimize the electricity charges and peak power but put a less emphasis on the human comfort dwelling in the residence. The discomfort and displeasure from the energy management only focusing on reduction of electricity charge will make the residential customer reluctant to enroll the real time pricing plan. In this paper, therefore, we propose optimal load control strategy which aim to achieve not only minimizing the electricity charges but also maintaining human comfort by introducing "the human comfort coefficient." Using the human comfort coefficient, the energy management system can reflect the various human personality and control the loads within the range that the human comfort is maintained. Simulation results show that proposed load control strategy leads to significant reduction in the electricity charges and peak power in comparison with the conventional load management method.

수원시 상수관망에서 잔류염소와 재염소주입의 효과 예측 (Simulation for Chlorine Residuals and Effect of Rechlorination in Drinking Water Distribution Systems of Suwon City)

  • 김경록;이병희;유효식
    • 상하수도학회지
    • /
    • 제14권1호
    • /
    • pp.108-116
    • /
    • 2000
  • Chlorine is widely used as a disinfectant in drinking-water systems throughout the world. Chlorine residual was used as an indicator for prediction of water quality in water distribution systems. The variation of chlorine residual in drinking water distribution systems of Suwon city was simulated using EPANET. EPANET is a computerized simulation model which predicts the dynamic hydraulic and water quality behavior within a water distribution system operating over an extended time period. Sampling and analysis were performed to calibrated the computer model in 1999 (Aug. Summer). Water quality variables used in simulations are temperature, roughness coefficient, pipe diameter, pipe length, water demand, velocity and so on. Extended water residence time affected water quality due to the extended reaction time in some areas. All area showed the higher concentration of chlorine residual than 0.2mg/l(standard). So it can be concluded that any area in Suwon city is not in biological regrowth problem. Rechlorination turned out to be an useful method for uniform concentration of free chlorine residual in distribution system. The cost of disinfectant could be saved remarkably by cutting down the initial chlorine concentration to the level which guarantees minimum concentration (0.2mg/l) throughout the distribution system.

  • PDF

계통측에서 본 풍력발전단지 도입에 따른 해결과제 및 대책연구 (Problem and Solution of Wind Farm based on Distribution Power system)

  • 윤기갑;박상만;허엽;정상봉;김홍필;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.488-490
    • /
    • 2001
  • A dispered power system means a little bit of small power generation equipment located near the power-damend areas. Due to no power supply line, such a power source is very favorable for the decrease in loss of electric power supply, in comparison to the giantly focused power source, Because of small power source, this power source also corresponds promptly to the variation of power demend. On the basis of energy saving, environmental reservation, and utilization of natural or unused energy, solar power plants can be introduced into the residence section of cities and small water or wind-power plants near the urban areas. In case of Korea, some wind farm have been introduced into Cheju island, Condensed introduction of several small power sources into an used distribution line may, however, result in a big problem, it is, therefore, necessary that protective-cooporative plans between power quality and distribution line should be introduced for efficient utilization of KEPCO distribution system.

  • PDF

HEAT-UP AND COOL-DOWN TEMPERATURE-DEPENDENT HYDRIDE REORIENTATION BEHAVIORS IN ZIRCONIUM ALLOY CLADDING TUBES

  • Won, Ju-Jin;Kim, Myeong-Su;Kim, Kyu-Tae
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.681-688
    • /
    • 2014
  • Hydride reorientation behaviors of PWR cladding tubes under typical interim dry storage conditions were investigated with the use of as-received 250 and 485ppm hydrogen-charged Zr-Nb alloy cladding tubes. In order to evaluate the effect of typical cool-down processes on the radial hydride precipitation, two terminal heat-up temperatures of 300 and $400^{\circ}C$, as well as two terminal cool-down temperatures of 200 and $300^{\circ}C$, were considered. In addition, two cooling rates of 2.5 and $8.0^{\circ}C/min$ during the cool-down processes were taken into account along with zero stress or a tensile hoop stress of 150MPa. It was found that the 250ppm hydrogen-charged specimen experiencing the higher terminal heat-up temperature and the lower terminal cool-down temperature generated the highest number of radial hydrides during the cool-down process under 150MPa hoop tensile stress, which may be explained by terminal solid hydrogen solubilities for precipitation, and dissolution and remaining circumferential hydrides at the terminal heat-up temperatures. In addition, the slower cool-down rate generates the larger number of radial hydrides due to a cooling rate-dependent, longer residence time at a relatively high temperature that can accelerate the radial hydride nucleation and growth.

초고층 주상복합 건물의 실내 환경 성능 향상을 위한 외피부 개선방향에 관한 연구 (A Study on the Envelop to Improve Interior Environment Performance of High-rise Residential Building)

  • 박상훈;조가영;이선우;조재훈;여명석;김광우
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.306-309
    • /
    • 2006
  • The architectural difference between the existing residence and high-rise residential building causes changes on environmental conditions such as ventilation and insulation. The object of this study is to present the improvement on envelop of high-rise residential buildings to reduce heating and cooling load. To improve the environmental performance of envelop, it is necessary to modify envelop vent system and ensure intermediate space. In this study, the shape of vents in high-rise residential buildings has been inspected, and the survey about the interior environmental conditions related to the envelop of high-rise residential building has been conducted. Environmental measurement has been done to examine out door air quality for natural ventilation.

  • PDF

A Study on the Optimization of Microwave System for the Preparation of Activated Carbon

  • Kim, Dong-Sik;Park, Hwa-Chun;Byeon, Kyeong-Hwa
    • Carbon letters
    • /
    • 제3권4호
    • /
    • pp.205-209
    • /
    • 2002
  • In the reaction of gas-solid phases, the microwave energy plays a role as a catalyst, because it causes friction between adjacent molecules and enables an unique characteristics of interior heating of the materials. When the dipole gases are adsorbed inside of the pore of carbon materials, the gases are decomposed by the microwave energy and reacted with the carbon atoms. Using this principle, we could make the activated carbon from coconut shell within 20 minute, and this residence time for activation is about 1/16 of rotary kiln. The BET surface area of activated carbon made by microwave is about $1,100m^2/g$ similar to conventional method of rotary kiln. In this study, the power of microwave generator was 400~1000W, and the gas for activation was steam mainly.

  • PDF