• Title/Summary/Keyword: repeated measurements

Search Result 441, Processing Time 0.027 seconds

The effect of aromatherapy on pain in individuals with diabetes: a systematic review and meta-analysis

  • Mi-Kyoung Cho;Mi Young Kim
    • Journal of Korean Biological Nursing Science
    • /
    • v.26 no.2
    • /
    • pp.71-82
    • /
    • 2024
  • Purpose: This study systematically analyzed the impact of aromatherapy on pain in individuals with diabetes. Methods: A search was performed in seven electronic databases based on the PICO-SD (Population, Intervention, Comparison, Outcome, Study Design) framework. The population (P) of interest was individuals with diabetes, and the intervention (I) included aromatherapy targeting pain reduction. The comparison (C) consisted of control groups that received no intervention, another intervention, or usual care. The outcome (O) measured was pain. The quality of the selected literature was assessed using the Joanna Briggs Institute checklist. In MIX 2.0 Pro, the pooled overall effect of pain was calculated using Hedge's g and a random-effects model, and heterogeneity was calculated using the Q statistic and Higgin's I2 values. Meta-regression and exclusion sensitivity analyses were performed. Results: Five articles and seven studies were included, showing a significant pooled overall effect of aromatherapy on diabetes-related pain (Hedge's g = -1.83, 95% CI: -2.76 to -0.91). Meta-regression demonstrated that effectiveness in reducing pain was associated with studies conducted in West Asia, those with IRB approval, and those receiving funding. Additionally, interventions involving subjects under 60, lavender oil (vs. turpentine oil or blended oils), massage therapy (vs. topical application), fewer hours per session, and more repeated measurements (vs. pre/post measurements) were associated with pain reduction. Conclusion: Aromatherapy, especially with lavender oil, effectively manages diabetes-related pain. Short-duration massage application is also effective. A personalized selection of oil type and application method could optimize therapeutic outcomes for individuals with diabetes.

Effects of Gait Training Using a Shoulder-Back Orthosis on Balance and Gait in Patients with Stroke

  • Han-Byul Youn;Jong-Kyung Lee;Yu-Min Ko;Ji-Won Park
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.200-205
    • /
    • 2023
  • Purpose: The purpose of this study is to find out how gait training with shoulder-back assistive device affects dynamic and static balance, gait of patients with stroke and to help improve body alignment, balance, and gait ability in stroke patients. Methods: Measurements were taken of the 20 subjects before intervention without shoulder-back assistive device, after intervention with device, and follow up after an hour compared. Berg balance scale used to evaluate dynamic balance; wii balance board was used to measure static balance; and gait ability were measured by timed up and go test and 10-meter walk test. To analyze the results, a one-way repeated measures analysis of variance was implemented to compare the measurements. Results: The results showed that, after wearing the shoulder-back assistive device, the subjects' dynamic balance statistically significantly improved; no statistically significant difference was observed in static balance, although their balance ability was enhanced; and their increase in gait ability was statistically significant. Conclusion: This study proved that gait training combined with a shoulder-back assistive device positively impacted dynamic and static balance, gait of patients with stroke.

Reproducibility and accuracy of tooth size measurements obtained by the use of computer (컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구)

  • Kim, Eun-Jeong;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.563-573
    • /
    • 1999
  • The purpose of this study was to evaluate the availability of computer system for the measurement of tooth size in the model analysis through the comparison of two measurements: One was to use a computer; and the other was to use vernier calipers. Twenty sets of casts were used, which showed a moderate degree of crowding and full eruption of all teeth. The mesio-distal width of 12 teeth from the left central incisor to the left first molar at each set of the casts were measured twice with vernier calipers and a computer respectively. This measurement was repeated two weeks later. First, for the reproducibility analysis, the two computer measurements were compared then the vernier calipers measurements were compared. Second, all the teeth were sepapated into the region of mesiodistal contact points and its width was measured by a micrometer to obtain standard measurements. For the accuracy analysis, these standard measurements were compared with the measurements from the dental casts using two methods. The difference between them was defined as the measurement error. To investigate the cause of measurement error, an examination was made for the presence and degree of contact point deviation on each tooth from the upper and lower occlusograms, and the mesio-distal angulation of each tooth was measured with TARG. Following results were obtained through statistical analysis. 1. In the analysis for reproducibility; the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in one out of twelve teeth. 2. In the analysis for accuracy; compared with the standard measurements, the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in two out of twelve teeth. 3. Compared with the standard measurements, the measurements with vernier calipers were apt to be larger at the upper first molar, and smaller at the lower first molar The computer measurements, however, were apt to be larger at both upper and lower first molars. 4. The measurements with vernier calipers showed the largest error at the lower first molar and the degree of error was variable according to the tooth while the difference of error was small in the computer measurements. 5. In the analysis for the correlation of the degree of measurement errors with the contact point deviation index and the mesio-distal crown angulation of each tooth, the measurements with vernier calipers did not show significant correlation while the measurements with computer showed slight Positive correlations. The results of this study indicate that a computer system may be useful for the measurement of tooth size in the model analysis.

  • PDF

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

Customized Pattern-Recognition Technique using Vision Measurement System Development in New Car Manufacturing Process (패턴인식 기법을 적용한 신차 제조공정 맞춤식 비젼 계측시스템 개발)

  • Lee, Gyung-Il;Kim, Jae-yeol;Roh, Chi-sung;Choi, Choul Jun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.51-59
    • /
    • 2016
  • Measurements of the automobile manufacturers are available anywhere and anytime, directly based on the criterion of failure is measured. The maintenance of high-precision production activities is direct evidence of the fact that competitive manufacturing activities are very important in determining the success of companies to recall defective starting from raw material costs. The current manufacturing sites produce calipers and clearance gauge the degree of tool only specific. Therefore, judging the quality, including the number of errors, requires a lot of attention to the dimension failures in day-to-day measurements and measurement tasks and duties repeated in difficult situations. In this paper, we aim to develop a vehicle manufacturing plant site using each of the manufacturing processes while operating a measurement tool. We display it using the Image Processing PC-based S/W with all those visual facts by management and recorded as image information a more accurate and current situation to obtain information and share visual measurements. We carry out research on the design and development vision inspection algorithm applied for pattern-recognition techniques that can help manufacturing site quality control.

Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man (인체에서 Pick 원리 및 열희석법에 의한 심박출량 측정의 비교 연구)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 1981
  • Measurement of cardiac output by thermodilution method is easy to perform and can be repeated at very short intervals and offers a number of theoretical and practical advantages. The purpose of this paper is to reevaluate the accuracy and reproducibility of the thermodilution cardiac output by comparing the results with those obtained by the direct Fick technique. From January through April 1981 [4 months], 26 simultaneous cardiac output measurements were made using thermodilution and direct Fick methods in 12 patients in the intensive care unit of Severance Hospital following open heart surgery. The average age of the patients was $34.8{\pm}12.0$ [SD] years [range; 17-57 years]. For cardiac output determination by thermodilution technique [$CO_TD$], a Swan-Ganz Thermodilution Catheter, Model 93A-131-7F [Edwards Laboratories], a Cardiac Output Computer, Model 9520A, and Strip Chart Recorder, Model 9810 [Edwards Laboratories] were used. For the determination of cardiac output by direct Fick principle [$CO_Fick$], a Van Slyke Manometric Apparatus [Thomas] for the measurements of arteriovenous oxygen content difference and a Collin`s Respirometer with Kymograph for the measurement of oxygen consumption were used. The correlation between the simultaneously measured $CO_TD$ and $CO_Fick$ was found to be $CO_Fick$ = 0.95.$CO_TD$ + 0.1073, [r= 0.9777, P < 0.001 ]. For 26 double or triple determinations of $CO_TD$, the values ranged from 1.77 L/min to 6.66 L/min, with a reproducibility of 2.18%. The maximum difference of $CO_TD$ for $CO_Fick$ was between +11.99% and -12,99% [$Mean{\pm}SD$ = $6.07{\pm}3.97$%]. Measurement of cardiac output by thermodilution method provides a simple, rapid, reproducible and highly accurate method for multiple cardiac output measurements suitable for use at the bedside. Comparison of Cardiac Output Determination by Direct Fick and Thermodilution Method in Man.

  • PDF

Influence of Cervical Accessibility of Maxillary Molars on Plaque Control (상악대구치의 치경부 접근도가 치태조절에 미치는 영향)

  • Roh, Tae-Kyung;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.4
    • /
    • pp.815-821
    • /
    • 2000
  • The purpose of this study was to evaluate the influence of accessibility to dental cervices of maxillary molars upon plaque control level of these areas. Fifthy-seven dental students with healthy gingiae participated in this study. Maxillary dental casts were fabricated for each participants. Using the casts, cervical accessibility was measured at the mid-palatal point of maxillary first and second molars. Cervical accessibility was defined as the perpendicular distance from the entrance of gingival sulcus to the imaginary line between the most protruded points of palatal gingiva and tooth surface, and classified into degree I(${\leq}0.5mm$), II($>0.5mm,\;{\leq}1.0mm$), III($>1.0mm,\;{\leq}1.5mm$), and IV(>1.5mm). Plaque score was recorded as the distance from crest of gingival margin to the most coronal extent of plaque. Measurements of plaque score were repeated 3 times at 1-week intervals. After the baseline measurements, the participants began to use unitufted brushes on randomly assigned right or left side. Two weeks later, a session of plaque score records identical to the baseline measurements was started. The maxillary second molars showed higher cervical accessibility than the first molars(p<0.01), but the plaque scores of maxillary second molars were also higher than those of first molars(p<0.01). For the maxillary first molars, correlation between accessibility and plaque score was statistically significant, but such correlation was not found for the second molars. Use of unitufted brushes decreased the plaque score(p<0.01). Correlation between accessibility and the degree of plaque score improvement was not found. These findings suggest that cervical accessibility may influence the amount of plaque, and use of adjunctive oral hygiene devices may be helpful in maintaining optimal oral hygiene level at the areas of low cervical accessib ility.

  • PDF

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

  • Lee, Jeong-Il;Lee, Cheol Min;Shim, In-Keun;Kim, Seong-Mi;Lee, Woo-Seok;Kim, Yoon-Shin
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2394-2398
    • /
    • 2013
  • Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798, 10.1977, $98.3768{\mu}g/m^3$, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is $0.9435{\mu}g/m^3$ and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate ($1{\mu}L$ or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.

Rotordynamic Performance Measurements of a Two-Pad Beam-Type Gas Foil Journal Bearing for High Speed Motors (고속 전동기용 2 패드 빔 타입 가스 포일 저널 베어링의 회전체동역학 성능 측정)

  • Jeong, Kwon Jong;Hwang, Sung Ho;Baek, Doo San;Kim, Tae Young;Kim, Tae Ho
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.205-212
    • /
    • 2022
  • This paper presents experimental measurements of the structural characteristics of a two-pad beam-type gas foil journal bearing and its rotordynamic performance for a high-speed motor-driven turbocompressor. The test bearing had two top foils and two beam foils, each with an arc length of ~180°. Each beam foil was etched to obtain 40 beams with six geometries of different lengths and widths. The insertion of beam foils into the bearing housing produces equivalent beam heights. The structural tests of the bearing with a non-rotating journal revealed a smaller bearing clearance and larger structural stiffness for the load-on-pad configuration than for the load-between-pads configuration. Rotordynamic performance measurements during driving tests up to 100 krpm demonstrated synchronous vibrations and subsynchronous vibrations with large amplitudes. The test was repeated after inserting the shim between the top foil and beam foil to reduce the bearing radial clearance. The reduced bearing clearance resulted in a reduction in the peak amplitude of the synchronous vibrations and an increase in the speed at which the peak amplitude occurred. In addition, the onset speed and amplitude of the subsynchronous vibrations were dramatically increased and diminished, respectively. The rotor coast-down tests at 100 krpm show that the reduction in the bearing clearance extends the time to rotor stop, thus implying an improvement in hydrodynamic pressure generation and a reduction in bearing frictional torque.

The effect of repeated firings on the color of zirconia-based all-ceramic system (반복 소성이 지르코니아 전부도재관의 색조에 미치는 영향)

  • Jang, Jung-Eun;Kim, Mu-Hyon;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.73-79
    • /
    • 2011
  • Purpose: The aim of this study was to evaluate the effect of repeated firings on the color of zirconia restoration with different shading method. Materials and methods: Three different types of zirconia frameworks (adding metallic pigments to the initial zirconia powder before sintering (Group NM), dipping the milled frameworks in dissolved coloring agents (Group KI), or application of liner material to the sintered white frameworks (Group KW) were used to support A3 shade dentin porcelain. Repeated firings (3, 5, or 7) were performed, color differences among ceramic specimens were measured using a colorimeter. Repeated measurements analysis of variance (ANOVA) was used to analyze the data for significant difference. The Tukey Honestly Significant Different (HSD) test was used to perform multiple comparisons (${\alpha}$ = .05). Results: 1. $L^*a^*b^*$ values of the ceramic systems were affected by the number of firings (1, 3, 5 or 7 firings) (P < .001) and shading methods (P < .001). 2. As the number of firings increased, the $L^*$ (for all groups) and $a^*$ value (for KW and NM groups) decreased and the $b^*$ value(for all groups) increased. 3. The mean color differences caused by repeated firings were perceptible (${\Delta}E$ > 1) for group KW and KI fired after 3 times, except for group NM fired after 7 times. 4. In order of decreasing ${\Delta}E$ value fired after 7 times, the values were group KI(${\Delta}E$ = 2.26) > group KW (${\Delta}E$ = 1.47) > group NM (${\Delta}E$ = 1.08) (P < .001). Conclusion: Repeated firings influenced the color of the zirconium-oxide all-ceramic specimens with different shading methods.