• 제목/요약/키워드: removal torque

검색결과 145건 처리시간 0.032초

Influence of the implant abutment types and the dynamic loading on initial screw loosening

  • Kim, Eun-Sook;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권1호
    • /
    • pp.21-28
    • /
    • 2013
  • PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at $30^{\circ}$ to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for $10^5$ cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (${\alpha}$=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after $10^5$ cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.

THE EFFECT OF AUTOLOGOUS PLATELET-RICH PLASMA (PRP) ON BONE FORMATION AROUND DENTAL IMPLANT IN THE RABBIT: A HISTOMOR-PHOMETRIC AND REMOVAL TORQUE STUDY

  • Yi Yang-Jin;Yang Jae-Ho;Lee Sun-Hyung;Kim Yung-Soo;Kwon Sang-Ho
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.659-681
    • /
    • 2001
  • Platelet-rich plasma(PRP) has been known to increase the rate and degree of bone formation by virtue of growth factors in concentrated platelets. Although its great healing effect on bone defect or pre-implantation site preparation in conjunction with bone substitute has been reported, the effect associated with implant is unknown. The purpose of this study was to investigate the effect of PRP on rapid osseointegration of endosseous dental implants in the rabbit tibiae. Twenty two adult female New Zealand white rabbits, weighing approximately 2.7-3.3kg, were used for this study. Twelve of the 22 animals were used for histomorphometric analysis and ten of the 22 were for removal torque test. Each animal received two implants in each tibia (two treated with PRP and two as control) and was given fluorochrome intramuscularly. For histomorphometric analysis, rabbits were divided into four groups according to the healing period. At 1 week, 2 weeks, 4 weeks and 8 weeks postoperatively, each three animals were sacrificed serially and the amount and rate of bone formation around dental implant were examined on the undecalcified sections under fluorescent microscope, polarized microscope and light microscope connected to a personal computer equipped with image analysis system. For removal torque test, rabbits were divided into two groups and removal torque tests were performed at 4 weeks, 10 weeks after implant placement. In total, 88 screw shaped, commercially pure titanium implants (Neoplant, Neobiotech, Seoul, Korea) were used in this study. Labeling pattern reflected differences of two groups in bone formation rate at each period. Histomorphometrically, PRP group showed significantly higher bone volume within threads compared to control group at 2 weeks ($70.30{\pm}4.96%$ vs. $50.68{\pm}6.33%$; P < .01) and 4 weeks ($82.59{\pm}5.94%$ vs. $72.94{\pm}4.57%$; P < .05 ). PRP group at 1, 2 and 4 weeks revealed similar degree of bone volume formation comparable to control group at 2, 4 and 8 weeks, respectively. On the other hand, while PRP group showed higher bone-implant contact ($47.37{\pm}8.09%$) than control group ($33.16{\pm}13.47%$) at 2 weeks, there were no significant differences between PRP group and control group for any experimental period. Removal torque values also showed no significant differences between PRP group and control group at any experimental period (P > .05). These findings imply that PRP could induce rapid, more bone formation around implant during early healing period and get faster secondary stability for reducing healing period, though it has not induced bone maturation enough to resist functional loading.

  • PDF

가토 경골에 식립된 Ca-P 박막코팅 임프란트의 뒤틀림 제거력 및 조직형태학적 평가 (THE EVALUATION OF THE REMOVAL TORQUE AND THE HISTOMORPHOMETRY OF THE CA-P COATING SURFACE IN RABBIT TIBIA)

  • 곽명배;이청희
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.556-571
    • /
    • 2004
  • Statement of problem: Surface texture of the implant is one of the important factors of the implant success, especially in the immediate implant loading. Many methods of the surface treatment of implant have developed and introduced. Purpose : This study was to evaluate the effects of the Ca-P coating implant crystallized the hydroxyapatite on the surface by the removal torque test and the histomorphometric analysis in vivo. Material and methods: 135 screw type implants, 4.0mm in length and 3.75mm in diameter were used in this study. Implants were divided into 3 groups and treated in the different mothods. Group I was not treated, Group II was treated in the SLA method, and Group III was treated in the Ca-P coating with the anodizing method and the hydroxyapatite was crystallized on the surface with the hydrothermal treatment. Firstly, the surface roughness of each group was measured, 45 rabbits were used in this experiment. Two implants were inserted on right tibial metaphysis and one implant was inserted on left side with the alternating order. After the healing periods of 3, 5, and 12 weeks, the rabbits were sacrificed to evaluate the osseointergration by the removal torque test and the histomorphometric analysis. Results : 1. In the analysis for the surface roughness, Group II showed the highest roughness. And Group III showed higher secondly. There was a significant difference one another statistically 2. In the removal torque test, Group III and II were significantly higher than Group I. There was no statistical difference between Group III and Group II. 3. For all Groups, the removal torque values at 12th week were significantly higher than at 3rd and 5th week. 4. In histomorphometric analysis, the bone implant contact rates of Group III and II were higher than that of Group I at 3rd and 5th week. There was a significant difference at 5th week. 5. In histomorphometric analysis, the bone implant contact rate of Group III and II increased from 3rd week to 5th week, but decreased at 12th week. In Group I, the contact rate at 12th week was significantly higher than at 3rd week and 5th week.

사용 방법에 따른 임플란트 토크 조절기의 정확성 비교 분석 연구 (Comparative analysis of accuracy of how to use the implant torque controllers)

  • 조리라;박찬진;허윤혁;이지혜;김대곤
    • 대한치과보철학회지
    • /
    • 제51권4호
    • /
    • pp.300-306
    • /
    • 2013
  • 연구 목적: 임상에서 가장 보편적으로 사용되는 기계식 토크 조절기를 선택하여 토크 조절기를 사용하는 방법에 따라서 제조사에서 권장하는 토크를 적용하고 유지하는데 정확도의 차이가 있는지를 비교, 분석하고자 하였다. 연구 재료 및 방법: 36개월을 사용한 3개 제조회사 제품의 토크 최대값 제한 장치 형태의 기계식 토크 조절기를 대상으로 하였다. 토크 조절기를 사용할 때마다 핸들 부위를 조이고 사용 후에는 핸들 부위를 풀어서 토크 조절기 내부의 스프링이 압축력에 의해 변형되는 것을 막고자 한 그룹과 토크 조절기를 사용 후에도 핸들 부위를 풀어내지 않고 토크 조절기 내부의 스프링이 압축력 하에 유지되게 사용한 그룹으로 나누어, 총 6개의 토크 조절기를 이용하여 풀림 토크를 측정하였다. 반복 측정에 따른 풀림 토크값의 차이를 비교하기 위해 repeated measures of ANOVA test (${\alpha}=.05$)를 사용하였고, 사용 방법의 차이에 따른 두 그룹간의 비교를 위해 독립표본 t-검정(Independent sample t-test)을 시행하였다. 결과:모든 실험군에서 반복 측정에 따라 풀림 토크값이 유의성 있게 감소하는 것으로 나타났고(P<.05), 사용 방법에 따른 두 그룹 간에 풀림 토크값은 유의한 차이가 있었다. 결론: 토크 조절기를 사용한 뒤 다시 핸들부분을 풀어서 토크 조절기 내부의 스프링이 압축력에 의해 변형되는 것을 막고 스프링의 복원력을 회복한 그룹은 그렇게 사용하지 않은 그룹과 통계적으로 유의한 차이가 관찰됐고, 기준 토크값(30 Ncm)에 좀 더 가까운 풀림 토크값을 보였다.

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants

  • Mohammed, Hnd Hadi;Lee, Jin-Han;Bae, Ji-Myung;Cho, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.62-69
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION. Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

Comparison of removal torques of SLActive® implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application

  • Park, Sang-Hun;Park, Kyung-Soon;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.110-115
    • /
    • 2016
  • PURPOSE. The purpose of this study was to compare the removal torques of a chemically modified SLActive implant and a blasted, laser-treated (BLT) implant, which were soaked in saline for 2 weeks after their surface modifications. The removal torques of the two implants were measured 4 weeks after their implantation into the bone defect area in rabbit tibias with concentrated growth factor (CGF) application. MATERIALS AND METHODS. To make artificial bone defects in the cortical layers of both tibias, an 8-mm diameter trephine bur was used. Then, prepared CGF was applied to the bony defect of the left tibia, and the bony defect of the right tibia was left unfilled. Four weeks later, the surgical sites of 16 rabbits were re-exposed. For 8 rabbits, the SLActive implants (Straumann, Switzerland) were inserted in the left tibia, and the BLT implants (CSM implant, Daegu, Korea) were inserted in the right tibia. For other rabbits, the BLT implants were inserted in the left tibia, and the SLActive implants were inserted in the right. Four weeks afger the insertion, torque removal was measured from 4 rabbits exterminated via $CO_2$ inhalation. RESULTS. No significant difference was observed between removal torques of the BLT implant and the SLActive implant (P>.05). CONCLUSION. It was found that BLT surface modification exhibited excellent osseointegration. In addition, CGF application did not affect the insertion and removal torque of the implants.

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

Bone Response to Anodized Titanium Implants in Rabbits

  • Lee, Jae-Hyun;Lee, Cheol-Won;Kim, Chang-Hyen;Pyo, Sung-Woon
    • Journal of Korean Dental Science
    • /
    • 제4권1호
    • /
    • pp.26-32
    • /
    • 2011
  • Purpose: The quality of implant surface is one of the factors that influence wound healing of implant site and subsequently affect osseointegration. The objective of modification of the surface properties of an implant is to affect the biological consequence. The purpose of this study is to evaluate the biologic response of osseous tissue to anodized implants. Materials and Methods: Two machined titanium implants for control group were installed in a tibia of each rabbit and two anodized implants for test group were installed in the other tibia of each rabbit. At the moment the implants were installed, resonance frequency analysis (RFA) values were measured. After healing periods of 1, 2, 3, and 7 weeks, the implants were uncovered and RFA values were measured again. Removal torque was measured for one implant in the test group and one implant in the control group. Histological evaluation was executed in the other implants. Results: Both of test group and control group have the tendency of greater RFA change rate and removal torque value as healing periods became longer, but were statistically insignificant (P>0.05). However, in the case of the same healing period, the test group tended to have greater RFA change rate and removal torque than the control group (P<0.05). More active new bone formation from endosteal surface was noted on the anodized surface than machined surface in specimen after 1 week. There were no significant differences between the test group and control group in histological evaluations. Conclusion: In summary, the anodized surface showed slightly favorable results and it is postulated that it may facilitate improved stability in bone.

The influence of systemically administered oxytocin on the implant-bone interface area: an experimental study in the rabbit

  • Cho, Sung-Am;Park, Sang-Hun;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.505-511
    • /
    • 2014
  • PURPOSE. The purpose of this study was to assess the effect of systemically administered oxytocin (OT) on the implant-bone interface by using histomorphometric analysis and the removal torque test. MATERIALS AND METHODS. A total of 10 adult, New Zealand white, female rabbits were used in this experiment. We placed 2 implants (CSM; CSM Implant, Daegu, South Korea) in each distal femoral metaphysis on both the right and left sides; the implants on both sides were placed 10 mm apart. In each rabbit, 1 implant was prepared for histomorphometric analysis and the other 3 were prepared for the removal torque test (RT). The animals received intramuscular injections of either saline (control group; 0.15 M NaCl) or OT (experimental group; $200{\mu}g/rabbit$). The injections were initiated on Day 3 following the implant surgery and were continued for 4 subsequent weeks; the injections were administered twice per day (at a 12-h interval), for 2 days per week. RESULTS. While no statistically significant difference was observed between the two groups (P=.787), the control group had stronger removal torque values. The serum OT concentration (ELISA value) was higher in the OT-treated group, although no statistically significant difference was found. Further, the histomorphometric parameter (bone-to-implant contact [BIC], inter-thread bone, and peri-implant bone) values were higher in the experimental group, but the differences were not significant. CONCLUSION. We postulate that OT supplementation via intramuscular injection weakly contributes to the bone response at the implant-bone interface in rabbits. Therefore, higher concentrations or more frequent administration of OT may be required for a greater bone response to the implant. Further studies analyzing these aspects are needed.