• Title/Summary/Keyword: removal torque

Search Result 145, Processing Time 0.023 seconds

INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS (임플란트 직경이 골유착에 미치는 영향에 관한 연구)

  • Lee Jun-Ho;Shin Sang-Wan;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

Investigation of osseointegration according to the healing time after having iatrogenic mobility of implant fixtures (임플란트 고정체의 인위적 비틀림 후 시간 경과에 따른 골재유착 반응에 관한 연구)

  • Hwang, Yun-Jin;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.308-314
    • /
    • 2010
  • Purpose: The purpose of this study is to analyze the change in re-osseointegration over time and bone reaction at the interface between implant fixture and the surface of the bone, after destroying re-osseointegration by distorting the bone-implant interface artificially. Materials and methods: Experimental implant fixtures (cp titanium, ${\phi}3.75\;mm{\times}4\;mm$) which didn't have surface treatment were produced. Two or three fixtures were implanted on both tibias of twelve female rabbits (New Zealand white, more than 3.5 kg). Then after six weeks, removal torque (RT) was measured and the results were recorded as the first measurement values. The fixtures were submerged again to get reosseointegration between the bone and fixture. To identify the change in re-osseointegration of submerged fixtures over time, six groups had the healing time for four days (group I), one week (group II), two weeks (group III), three weeks (group IV), four weeks (group V) and five weeks (group VI), and then the secondary removal torque was measured for each group. To identify the bone formation under fluorescent light, tetracycline (15 mg/kg, IM) were treated on the rabbits of each group. After the second measurement, the rabbits were sacrificed, and 16 slides were made, two or three for each group. The slides were observed under the fluorescent light with light microscope. To find out the change in the secondary removal torque over the primary removal torque in progress of time, the averages of the increase rate of the primary and secondary torque removal force were calculated. Then, to find out if there were any critical differences between the primary removal torque and the secondary removal torque in each group and among the groups, the results were analyzed statistically by paired t- test, one-way ANOVA, and Duncan's Multiple Range Test. Results: In group I and II, secondary removal torque decreased, especially in group I. In group III, IV, V, and VI, secondary removal torque increased critically. Comparing the differences among the groups, the critical difference was shown between group I, II and group III, IV, V, VI. Mineralization at the interface between the bone and implant fixture was identified from the first week, and bone formation was shown more clearly from the second week. Conclusion: If the implant fixture remains unforced for a certain period of time after the fixture has had iatrogenic mobility, re-osseointegration occurs at the surface of the fixture, and for tibias of rabbits, higher re-osseointegration was obtained within two weeks.

Comparison of removal torque between prefabricated and customized abutment screw (기성품과 맞춤형 임플란트 지대주 나사의 풀림 토크 비교)

  • Jamiyandorj, Otgonbold;Kim, Jee-Hwan;Kim, Mu-Seong;Park, Young-Bum;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.243-248
    • /
    • 2012
  • Purpose: The purpose of this study is to compare the removal torque between prefabricated and customized implant abutment screw. Materials and methods: Three types of implant system (Osstem, Astra, Zimmer) were used. For each system, prefabricated abutment screw (control group) and customized abutment screw (test group) were used to connect the fixture and the abutment (n = 6). Digital torque gauze was used to control the tightening torque and the screws were tightened under each manufacturer's recommendation. 10 minutes after the connection the same tightening torque was applied, and 5 minutes after the second connection, the removal torque was measured. This procedure was repeated 10 times. In the cyclic loading test, 10 minutes after the first connection to the 6 groups (n = 3), the same tightening torque was applied, and a total of 1,000,000 time loading was applied at 30 degree angle to long axis with 50 N load. Repeated measures of ANOVA test (${\alpha}$=.05) was used as statistics to evaluate the effect of repeated loading number on the removal torque. Independent t-test was used to evaluate the difference in removal torque after cyclic loading. Results: The removal torque significantly decreased as the number of loading repetition increased (P<.05). In the 10 time repetition test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Also in the cyclic loading test, there was no significant difference between the prefabricated and customized implant abutment screw of the 3 implant system (P<.05). Conclusion: Within the limitation of this study, there was no significant difference in the removal torque between the prefabricated abutment screw and customized abutment screws.

Effect of dual pitch mini-implant design and diameter of an orthodontic mini-implant on the insertion and removal torque (교정용 미니임플랜트의 이중 피치와 직경의 차이가 삽입 및 제거 토크에 미치는 영향 평가)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.275-283
    • /
    • 2006
  • Objective: Small orthodontic mini-implants are useful as anchorage. However they have some weaknesses such as loosening. This study was carried out to analyze the mechanical effects of the dual pitch and diameter on the insertion and removal torque of mini-implants. Methods: The threads of mini-implants were mono and dual pitch. The diameters of mini-implants were 1.4 mm and 1.6 mm. Four groups were tested (mono 1.4 mm, mono 1.6 mm, dual 1.4 mm and dual 1.6 mm). All were inserted and removed on polyurethane foam with the torques being measured. Results: The maximum torque of the dual pitch groups was higher than the mono pitch groups during removal but lower during insertion. The maximum torque of the 1.6 mm diameter groups was higher than the 1.4 mm diameter groups during insertion and removal. The dual pitch 1.4 mm group showed the lowest insertion torque but had similar or superior levels of removal torque to that of the mono pitch 1.6 mm group. Conclusions: The dual pitch especially showed a continuous high removal torque after the peak. Despite the small diameter, the dual pitch might improve the initial mechanical stability.

Comparison of histologic observation and insertional and removal torque values between titanium grade 2 and 4 microimplants (Grade 2, 4 티타늄 마이크로 임플랜트의 식립 및 제거 토크와 식립 후 조직학적 반응의 비교)

  • Kang, Sung-Taek;Sung, Jae-Hyun;Kyung, Hee-Moon;Park, Hyo-Sang;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.36 no.3 s.116
    • /
    • pp.171-177
    • /
    • 2006
  • The purpose of this study was to evaluate the light microscopic features and the maximum insertional and removal torque value of microimplants, made from titanium grade 2 or 4, in the tibia of 6 rabbits. First, the maximum torque values of microimplants at implantation were measured. After 2, 8, and 12 weeks of healing time, the microimplant-containing segments of tibia of 2 rabbits were removed and the maximum removal torque of each microimplant were measured. Comparisons of histologic examination and insertional and removal torque values were carried out for the two groups of microimplants. Removal torque values were significantly increased in both groups after 8 and 12 weeks as compared to 2 weeks after implantation. Other values measured did not show any statistically significant differences and there were no histological differences between grade 2 and 4 titanium. Based on these results, this study showed that there were no significant differences between grade 2 and 4 titanium. It seems better to use grade 4 titanium for making microimplants because grade 4 titanium is mechanically harder than grade 2 titanium and has similar retention.

An investigation of reosseointegration according to time course after mechanical loosening of the osseointegrated implant fixtures (표면처리 임플란트 고정체의 의원성 동요 후 시간 경과에 따른 재골유착에 관한 연구)

  • Ye, Sun-Hae;Cho, Jin-Hyun;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.3
    • /
    • pp.203-211
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the reosseointegration periods when the rough surface implants, which had complete bone-implant ankylosis, suddenly losed the osseointegration. Materials and Methods: The implants with RBM surface treatment were inserted into both tibias of 23 rabbits. Two implants were submerged into each side. After six weeks, the primary removal torque was measured by Digital torque gauge, and then the implants were replaced and submerged to estimate the level of reosseointegration. After assigned healing periods for each group, the removal torque was measured again. BIC (Bone-Implant contact, %) ratio was measured through histomorphometric analysis.Paired t-test was processed by SPSS 14.0. One-way ANOVA and Tukey's post-hoc test was processed to analyze statistically significant differences among the groups. Results: In comparison with the primary removal torque, the secondary removal torque was increased after 11 days and significantly increased from 2 weeks. In fluorochrome labeling, the origin of mineralization was observed after 7 days, which showed as fluorescent bands around the bone-implant interfaces. After 11 days, the bone formation was apparent, and it is increased continuously with the passage of the time. Conclusion: In 11 days after the implant replacement, the secondary removal torque was almost as same as the primary value, and was significantly higher from 2 weeks. The mineralized shapes were observed in 7 days after the implant replacement, and then the bone formation appeared visibly in 11 days.

Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias (단일, 이중 산처리 임플란트의 회전제거력 비교)

  • Kim, Jong-Jin;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.335-341
    • /
    • 2019
  • Purpose: Chemically strong-acids (HF and $HCl/H_2SO_4$) dual etching implant surfaces have higher strengths of osseointegration than machined implant surfaces. However, the dual acid treatment deteriorates the physical properties of the titanium by weakening the fatigue resistance of the implant and causing microcracks. The removal torque comparison between the dual-acid etched (hydrochloric acid, sulfuric acid, HS) and single-acid etched implants (hydrochloric acid, H) could reveal the efficiency of implant surface acid treatment. Materials and methods: Nine $3.75{\times}4mm$ dual-acid etched SLA implants and nine single-acid etched SLA implants were inserted into New Zealand rabbit tibias. After 10 days, removal torque, roughness, and wetting angle were measured. Results: Mean removal torque values were as follows: Mean removal torque were 9.94 Ncm for HS group and 9.96 Ncm for H group (P=.995). Mean surface roughness value were $0.93{\mu}m$ for HS group and $0.84{\mu}m$ for H group (P=.170). Root mean square roughness (RSq) values were $1.21{\mu}m$ for HS group and $1.08{\mu}m$ for H group (P=.294), and mean wetting angle values were $99^{\circ}$ for HS group and $98^{\circ}$ for H group (P=.829). Statistical analysis showed no significant difference between the removal torques, roughness, or wetting angles of the two groups. Conclusion: In this experiment, we found no significant difference in removal torque, roughness, or wetting angle between dual-acid etched and single-acid etched implants.

Osseointegration between Oxide Layer of Titanium and Bone by Different Heat Treatments (열처리에 따른 티타늄 Oxide Layer와 Bone 사이의 Osseointegration에 대한 연구)

  • Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.171-178
    • /
    • 2002
  • 본 연구의 목적은 순수 티타늄에 열처리를 통해 서로 다른 두께의 산화막을 형성하여 온도차이에 따른 골결합에 대한 영향을 관찰하고자 하는 것이다. 총 52개의 임플란트를 제작하여 열처리를 하지 않은 26개의 임플란트를 대조군으로, $600^{\circ}F(316^{\circ}C)$에서 10분간 열처리한 13개의 임플란트를 실험군 1로, $1200^{\circ}F(649^{\circ}C)$에서 10분간 열처리한 13개의 임플란트를 실험군 2로 하여 13마리의 가토의 경골에 식립한 후 12주 후의 removal torque를 측정 비교함으로써 다음과 같은 결과를 얻었다. 1. 실험군 2에서는 결정구조가 생성된 것이 관찰되었으나, 실험군 1에서는 무정형이었다. 2. 대조군에 비해 열처리를 한 실험군들이 더 큰 removal torque 값을 나타냈다(p=0.0059, 0.0039). 3. 실험군 2가 실험군 1에 비해 큰 removal torque 값을 나타냈다(p=0.0488).

The influence of iatrogenic mobilization in the initial stage of implant installation on final osteointegration (임플란트 식립 초기 의원성 동요가 최종 골결합에 미치는 영향)

  • Kwak, Myeong-Bae;Cho, Jin-Hyun;Lee, Du-Heong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.105-112
    • /
    • 2014
  • Purpose: The aim of present investigation was to find out the influence of several times iatrogenic mobilization in the initial stage of implant installation on bone-implant osteointegration. Materials and methods: The experimental implants (3.75 mm in diameter, 8.0 mm in length) were made of commercially pure (Grade IV) titanium, and were treated with RBM ($MegaGen^{(R)}$: Ca-P) on lower 4.0 mm part. Only lower part of implant was inserted to bone and the implants were nonsubmerged. The 130 implants (two in each tibia) were inserted into the monocortical tibias of 33 rabbits which each weighed more than 3.5 kg (Female, New Zealand White). According to the removal torque interval, the groups were divided into 13 groups, group I (1 day), group II (1 day + 2 days), group III (1 day + 2 days + 3 days), group IV (1 day + 2 days + 3 days + 4 days), group V (2 days), group VI (2 days + 4 days), group VII (2 days + 4 days + 6 days), group VIII (2 days + 4 days + 6 days + 8 days), group IX (4 days), group X (4 days + 7 days), group XI (4 days + 7 days + 10 days), group XII (4 days + 7 days + 10 days + 14 days) and control group. In the control group, the removal torque was measured at 8 weeks with a digital torque gauge (Mark-10, USA). In the experimental groups, the removal torque was given once, twice, three times or four times by experiment design before the final removal torque and the value was measured each time. The implants were then screwed back to their original positions. All the experimental groups were given a final healing time of 8 weeks after placement, in which values were compared with the control groups and the 1st, 2nd, 3rd or 4th removal torque values in each experimental group. Results: In comparison of the final removal torque tests among experimental groups, the removal torque value of experimental groups except group XII were not statistically different that of control group. And the values of group I and II were significantly higher than the values of group VI, VIII, X, XI, and XII. In addition, the values of group III, IV, and V were significantly higher than group XI and XII. In comparison of the removal torque in the each experimental group, the final removal torque were significantly higher in all groups except group VIII, X, XI, and XII. Conclusion: If sufficient healing time was allowed, a few mobilization of fixture at the very early stage after the implant placement in the rabbits didn't interrupt the final bone to implant osseointegration.

Screw Joint Stability under Cyclic Loading of Zirconia Implant Abutments (지르코늄 임플란트 지대주의 나사결합부 안정성에 관한 연구)

  • Lee, Mi-Soon;Suh, Kyu-Won;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.164-173
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of abutment material on screw-loosening before and after cyclic loading. Among the different materials of abutments, zirconia and metal abutment were used. Material and methods: Two types of implant systems: external butt joint(US II, Osstem Implant, Korea) and internal conical joint(GS II, Osstem Implant, Korea) were used. In each type, specimens were divided into two different kinds of abutments: zirconia and metal(n=5). The implant was rigidly held in a special holding to device ensure fixation. Abutment was connected to 30 Ncm with digital torque gauge, and was retightened in 30 Ncm after 10 minutes. The initial removal torque values were measured. The same specimens were tightened in 30 Ncm again and held in the cycling loading simulator(Instron, USA) according to ISO/FPIS 1480. Cycling loading tests were performed at loads 10 to 250 N, for 1 million cycles, at 14 Hz,(by subjecting sinusoidal wave from 10 to 250 N at a frequency of 14 Hz for 1 million cycles,) and then postload removal torque values were evaluated. Results: 1. In all samples, the removal values of abutment screw were lower than tightening torque values(30 Ncm), but the phenomenon of the screw loosening was not observed. 2. In both of the implant systems, initial and postload removal torque of zirconia abutment were significantly higher than those of metal abutment(P<.05). 3. In both of the implant systems, the difference in removal torque ratio between zirconia abutment and metal abutment was not significant(P>.05). 4. In metal abutments, the removal torque ratio of GS II system(internal conical joint system) was lower than that of US II system(external butt joint system)(P<.05). 5. In zirconia abutments, the difference in removal torque ratio between the two implant systems was not significant(P>.05). Conclusion: Zirconia abutment had a good screw joint stability in the condition of one million cycling loading.