• Title/Summary/Keyword: removable

Search Result 671, Processing Time 0.036 seconds

A Study on Application of Removable Soil Nail Walls (제거식 쏘일네일 벽체의 적용성에 관한 연구)

  • 김홍택;강인규;정성필;박사원;박시삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.481-488
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study controlled displacement and controlled force field pull-out tests are carried out 7 times in order to evaluate short-term and long-term pull-out characteristics of the removable soil nail. For evaluating application of removable soil nailing system, bending tests of removable soil nails and tensile tests of fixed sockets are carried out. In the removable soil nailing system, the predicted horizontal displacements from FLAC-2D are also compared with the field measurements occurred in stepwise excavation. And approach for the stability analysis of removable soil nailing system after removed is proposed.

  • PDF

TREATMENT OF MALOCCLUSION USING REMOVABLE ORTHODONTIC APPLIANCE AND MEAW IN GROWING CHILDREN (성장기 아동에서 가철식 교정장치와 MEAW를 이용한 부정교합의 치험례)

  • Yang, Kyu-Ho;Choi, Eun-Jong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.637-649
    • /
    • 1997
  • Early orthodontic treatment in growing children requires the removable orthodontic appliances. The removable orthodontic appliance can be used in the primary dentition and mixed dentition. The purposes of use of removable orthodontic appliance in prmary dentition or mixed dentition are the interception of skeletal or dental malocclusion, guiding the normal dentition, and retention after comprehensive orthodontic treatment. Therefore, it is needed to use the removable orthodontic appliance in children with malocclusion. This report presents cases of growing children with skeletal class II and III malocclusion treated with removable orthodontic appliance during mixed dentition and Multiloop Edgewise Arch Wire(MEAW) during permanent dentition. The results obtained through these cases were summarized as follows : 1. Removable orthodontic appliances guide normal dentition and skeletal growth in growing children. 2. Removable orthodontic appliances play an important role in intercepting malocclusion in mixed dentition before use of fixed orthodontic appliance. 3. MEAW can be applied to finishing stage of all cases and is effective in correction of occlusal plane, achievement of interdigitation, and control of dental inclination. 4. It is needed that removable appliances are used during mixed dentition through correct diagnosis and fixed appliance are used in permanent dentition.

  • PDF

STRESS ANALYSIS AT SUPPORTING TISSUE OF ABUTMENT TEETH AND RESIDUAL RIDGE ACCORDING TO DENTURE DESIGN WITH REMAINING UNILATERAL POSTERIOR TEETH (편측 후방 치아 잔존시 의치 설계에 따른 지대치지지 조직과 잔존 치조제의 응력 분석에 관한 연구)

  • Ahn, Kwang-Ho;Jung, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.185-199
    • /
    • 1999
  • This study was peformed to investigate the distribution and magnitude of stress at supporting tissue of abutment teeth and residual ridge tissue with remaining unilateral posterior teeth. Four types of removable partial dentures that included clasp retained removable partial denture, attachment retained removable partial denture, telescopic removable partial denture, and swing-lock partial denture were designed, and strain gauge was used for stress analysis. Each prosthesis was subjected to simulated vertical and oblique load. The following conclusions were drawn from this study. 1. The clasp retained removable partial denture generally distributed simulated vertical force more evenly to the supporting structure. 2. The stress at buccal side of 1st premolar was the lowest in swing-lock partial denture and that was highest in attchment retained removable partial denture. The stress at lingual side of 1st premolar was the lowest in telescopic partial denture. 3. In clasp retained removable partial denture, stress was lower at load site and ridge crest at mid-line, but it was higher at 1st premolar area on vertical load. 4. In attachment removable partial denture, stresses at buccal side of 1st premolar. lingual side of 1st premolar on vertical load, and ridge crest at midline on oblique load were higher. 5. In telescopic removable partial denture, stress at lingual side of 1st premolar was the least in all removable partial dentures, but the stress at load site was higher. 6. In swing-lock removable partial denture, stress at buccal side of 1st premolar was the lowest, and stresses at load site and distal end of residual ridge crest were higher.

  • PDF

Evaluation of Behavior Characteristics of Removable Soil Nails from the Field Pull-Out Tests (현장인발시험을 통한 제거식 쏘일네일의 거동특성 평가)

  • 김홍택;강인규;이대형;정성필;박시삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.137-144
    • /
    • 1999
  • Recently a removable soil nail is demanded due to problems beyond of economical and engineering purpose. In this study removable soil nails are developed and field pull-out tests are carried out 16 times in order to analysis pull-out characteristics of the removable soil nail. For the spacing and the installed position of fixed socket, the length of the soil nail, and W/C ratio of cement grout in the removable soil nail, pull-out characteristics of pull-out tests are analyzed. From the pull-out characteristics of removable soil nails, it is found that the spacing of fixed socket and W/C ratio of cement grout are important design parameters.

  • PDF

A SURVEY OF PARTIAL EDENTULISM AND REMOVABLE PARTIAL DENTURE DESIGNS FOR PATIENTS IN KOREA (한국인의 부분 치아 결손 증례와 국소의치 설계에 관한 연구)

  • Lee Si-Hyuk;Chang Ik-Tae;Kim Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.2
    • /
    • pp.235-248
    • /
    • 1994
  • There were many studies that distribute the partial edentulous states and examine the removable partial denture designs in the planning of removable partial denture treatment. This study was performed in the point of removable partial denture prescription to evaluate partial edentulism and its removable partial denture designs. The data was collected from the dental laboratory of each three dental colleges in Seoul and from two dental laboratories only for removable partial dentures as a prescription form. A total of 1411 cases with prescription form collected from dental laboratories were distributed for this study, then 788 cases were selected for this study. The case selection was done according to the contents of prescription form. The selected cases were divided into maxillary arch and mandibular and classified in terms of types of major connector and direct retainer, unbroken anterior teeth, Kennedy classification, the number of remaining teeth, and distribution of age and sex. The analyzed results were as follows : 1. The Kennedy classification I showed highest frequency both in maxilla and mandible. 2. The arch distribution of removable partial denture was 50.08% for maxilla and 49.92% for mandible. 3. The highest frequency in the distribution of direct retainer was the RPA clasp design. 4. The frequency of unbroken anterior 6 was 73.36% for maxilla and 82.30% for mandible. 5. The design of broad palatal strap and lingual bar revealed the highest prevalence in the major connector construction. 6. The mean number of remaining teeth per arch was 8.25 for maxilla and 8.37 for mandible. 7. The mean age of the patients supplied with removable partial denture was 52.25 years for men, 51.68 years for women, 52.11 years for maxilla, and 51.76 years for mandible and women showed more prevalence.

  • PDF

THE PRINCIPLE OF THE TOOTH-BORNE AND FREE-END REMOVABLE PARTIAL DENTURE DESIGN (치아지지및 유리단 국소의치의 설계원칙)

  • Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.217-229
    • /
    • 1990
  • The Applegate-Kennedy classification, the drawing of removable partial denture design using color coding, the selective tissue placement impression method in case of Class I and Class II removable partial dentures, the design of the swing lock attachment of an alternative approach to conventional removable partial denture, the design of the intracoronal or extracoronal attachment, and the removable partial denture design using a rotational path were presented. The following conclusions from the above things were presented : 1. The swing lock attachment removable partial denture can be effective to an alternative approach when the design of conventional removable partial denture is improper with markedly mobile remaining teeth or missing key abutments. 2. Intracoronal or extracoronal attachments must be selected care-fully considering the conditions of the abutment teeth and alveolar ridge whether more occlusal loads to the abutment teeth or to the alveolar ridge are distributed. 3. It must be almost prerequisite that a functional impression is taken in case of Class I and class II removable partial dentures and in case of tooth-borne removable partial dentures, a removable partial denture using rotational path is strong, hygienic, esthetic, and can be accomplished successfully in the clinical aspect when it is properly designed and fabricated through the complete understanding of an indication and a principle. 4. All necessary informations must be achieved with carefully investigated surveying procedure according to each clinical case by Applegate-Kennedy classification which can be helpful and useful in the clinical application and it is important that dentists themselves must be in the habit of drawing a reasonable partial denture design using a color coding in the paper sheet.

  • PDF

Economic Analysis of Installing Fixed and Removable Insulation for Pipe Wall Thinning Management (배관감육 관리를 위한 고정식 및 탈착식 보온재 설치 경제성 분석)

  • Hwang, Kyeongmo;Yun, Hun
    • Corrosion Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.320-325
    • /
    • 2016
  • To perform ultrasonic testing (UT) thickness measurement of the secondary side piping installed in nuclear power plants, the insulation for preventing heat loss should be removed. The type of insulation can be divided into fixed and removable insulation. Fixed and removable insulation have their own strengths and weaknesses. Removable insulation has been installed in the components susceptible to wall thinning caused by FAC and erosion from Shin-Kori unit 1, which commenced its commercial operation in 2011. In this paper, the number of repeated inspections of components and the number of replacements of fixed insulation were estimated and a more economical way was identified based on the manufacturing and installation costs for fixed and removable insulation.

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.