A Note on the Geostrophic Velocity Estimation from a AVHRR Image and its Application (AVHRR 자료를 이용한 지형류의 추정과 그 적용)

  • 이태신;정종률;오임상
    • Korean Journal of Remote Sensing
    • /
    • v.9 no.1
    • /
    • pp.79-93
    • /
    • 1993
  • The relative geostrophic velocity is estimated by using the MCSST(Multi-Channel Sea Surface Temperature) from a NOAA/AVHRR image and applied to the Korea Strait. Remote sensing technique can play a useful role to research for oceanic phenomena because of its synoptic, simultaneous and repetitive viewing. The high resolution data of AVHRR can determine the geostrophic flow more precisely than the hydrographic data on shipboard. As a result of research, the relative geostrophic velocity in the weatern channel of the Korea Strait is the strongest in the trough area and its maximum speed is about 23.8cm/sec in April, 1992. But this results include the error due to neglecting the effect of salinity in estimation the geopotential anomaly. The geostrophic volume transport through the western channel of the Korea Strait is the largest between trough area and the Tsushima Island.

Effect of Thermal Diffusion on Autumn Traffic in Street Space (가을철 교통조건에 따른 가로공간 열확산 분포 영향)

  • Yoon, Yong-Han;Kim, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.26 no.4
    • /
    • pp.467-481
    • /
    • 2017
  • This study sought to determine the changes in weather conditions in urban streets, along with conditions of traffic and roads in urban areas. The variations in weather conditions depending on traffic differed according to distance. First, the temperature difference measured by traffic results is as follows: T1 point $1.03^{\circ}C$, T2 point $1.04^{\circ}C$, T3 point $0.9^{\circ}C$, T4 point $1.01^{\circ}C$, and T5 point $0.31^{\circ}C$. The average difference between the measured temperatures by the point of measurement was $0.86^{\circ}C$. The changes in wind velocity according to traffic volume results of the measurements is T1 point 1.32 m/s, T2 point 0.80 m/s, T3 point 0.29 m/s, T4 point 0.04 m/s, and T5 point 0.09 m/s. The difference between the average wind speeds was 0.51 m/s and traffic jams caused substantial differences in distance. The relative humidity tended to be inversely proportional to temperature. The measurements results ares T1 point 2.29%, T2 point 2.67%, T3 point 2.47%, T4 point 2.16%, and T5 point 0.91% The difference between the average relative humidity was 7.3%. In case of independent sampling T test according to traffic volume, changes in wind velocity and temperature were directly proportional to the level of statistical significance(p<0.01). On the other hand, relative humidity tended to be inversely proportional; however, there was no statistical significance.

The assessment of the relative contribution of the shape of instantaneous unit hydrograph with heterogeneity of drainage path (배수경로 이질성에 의한 순간단위도 형상의 상대적 기여도 평가)

  • Choi, Yong-Joon;Kim, Joo-Cheol;Kim, Jae-Han
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.11
    • /
    • pp.897-909
    • /
    • 2009
  • The relative contribution of between hillslope-flow and stream-flow by heterogeneity of drainage path are quantitatively assessed in the present study with GIUH model based on grid of GIS. Application watersheds are selected Pyeongchang, Bocheong and Wi river basin of IHP in Korea. The mean and variance of hillslope and stream length are estimated and analyzed in each watershed. And coupling with observation storm events, estimate hillslope and stream characteristic velocity which dynamic parameters of GIUH model. The mean and variance of distribution of travel time (i.e. IUH) calculate using estimated pass lengths and characteristic velocities. And the relative contributions are assessed by heterogeneity of drainage path. As a result, the effect of the variance that determine shape of IUH dominate with hillslope's effect in the small watershed area (within 500 $km^2$). Thus, GIUH in the small watershed area must consider hillslope-flow.

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

Accelerated life testing of concrete based on stochastic approach and assessment

  • Zhu, Binrong;Qiao, Hongxia;Feng, Qiong;Lu, Chenggong
    • Computers and Concrete
    • /
    • v.19 no.1
    • /
    • pp.111-120
    • /
    • 2017
  • This study aimed to design the accelerated life testing (ALT) of concrete, which stimulating the special natural environment maximumly. Its evaluation indexes, such as dynamic elastic modulus, mass and ultrasonic velocity were measured, and the variation of relative mass and relative dynamic elastic modulus of concrete were studied. Meanwhile, the microanalysis method was used. Moreover, an exploratory application of the stochastic approach, the Weibull distribution and the lognormal distribution, were made to assess the durability of concrete structures. The results show that the ALT for simulating natural environment is more close to the service process of concrete structure under actual conditions; The relative dynamic elastic modulus can be used as the dominant durability evaluation parameters, because it is more sensitive to the environmental factors compared with the relative quality evaluation parameters; In the course of the concrete deterioration, the destruction of the salt freezing cycle is the dominant factor, supplemented by other factors; Both of those two stochastic approaches can be used to evaluate the reliability of concrete specimens under the condition of ALT; By comparison, The lognormal distribution method is better to describe the reliability process.

Gas Detecting Characteristics Using Catalytic Combustion Type Gas Sensor (접촉연소식 가스 센서를 이용한 감도특성)

  • Yoon, Hun-Ju;Ko, Keel-Young;Lee, Jong-Pil;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.773-777
    • /
    • 2002
  • In this study, we analyzed the LPG and LNG sensitivity measurement and voltage variation using catalytic type gas sensor characteristics in catalytic combustion type gas detecter sensors. gas detector shall operate as intended when exposed for 24 hours to air having a relative humidity of 0~85 percent at a temperature of $20[{\mu}m]$ and humidity of 45 percent at a temperature of $-10{\sim}40[^{\circ}C]$ the gas detecter sensors are to be subjected to operation for 210 days in an area that has been detemined to be equivalent to a typical residential atmosphere with an air velocity of 50 [cm/sec]. The source of energy for a gas detector sensors employing a supplementary basic circuit is energized from a separate source of supply direct applied voltage 2.1[V], 2.2[V], 2.3[V]. As a result, it was confirmed that the relative humidity and temperature by regression each analysis, compared to the LPG characteristic graph and methane characteristics graph by a relative humidity of 0 ~ 85 [%] at a temperature range of $-10{\sim}40[^{\circ}C]$ show a similar linear pattern on the whore.

  • PDF

SIMULATION OF RELATIVE MOTION OF FLOATING BODIES INCLUDING EFFECTS OF A FENDER AND A HAWSER (방현재와 계류삭 효과를 고려한 부유체의 상대운동 모사)

  • Shin, Sangmook
    • Journal of computational fluids engineering
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • A developed code is applied to simulate relative motion of floating bodies in a side-by-side arrangement, including effects of a fender and a hawser. The developed code is based on the flux-difference splitting scheme for immiscible incompressible fluids and the hybrid Cartesian/immersed boundary method. To validate the developed code for free surface flows around deforming boundaries, the water wave generation is simulated, which is caused by bed movement. The computed wave profile and time histories of wave elevation are compared with other experimental and computational results. The effects of a fender and a hawser are modeled by asymmetric force acting on the floating bodies according to a relative displacement with the bounds, in which the fender and the hawser exert no force on the bodies. It has been observed that the floating body can be accelerated by a gap flow due to a phase difference caused by the free surface. Grid independency is established for the computed time history of the body velocity, based on three different size grids.

A Study on The Velocity Distribution in Closed Conduit by Using The Entropy Concept (엔트로피 개념을 이용한 관수로내의 유속분포에 관한 연구)

  • Choo, Tai Ho;Ok, Chi Youl;Kim, Jin Won;Maeng, Seung Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4B
    • /
    • pp.357-363
    • /
    • 2009
  • When yields the mean velocity of the closed conduit which is used generally, it is available to use Darcy Weisbach Friction Loss Head equation. But, it is inconvenient very because Friction Loss coefficient f is the function of Reynolds Number and Relative roughness (${\varepsilon}$/d). So, it is demanded more convenient equation to estimate. In order to prove the reliability and an accuracy of Chiu's velocity equation from the research which sees hereupon, proved agreement very well about measured velocity measurement data by using Laser velocimeter which is a non-insertion velocity measuring equipment from the closed conduit (Laser Doppler Velocimeter: LDV) and an insertion velocity measuring equipment and the Pitot tube which is a supersonic flow meter (Transit-Time Flowmeters). By proving theoretical linear-relation between maximum velocity and mean velocity in laboratory flume without increase and decrease of discharge, the equilibrium state of velocity in the closed conduit which reachs to equilibrium state corresponding to entropy parameter M value has a trend maintaining consistently this state. If entropy M value which is representing one section is determinated, mean velocity can be gotten only by measuring the velocity in the point appearing the maximum velocity. So, it has been proved to estimate simply discharge and it indicates that this method can be a theoretical way, which is the most important in the future, when designing, managing and operating the closed conduit.

Do Inner Planets Modulate the Solar Wind Velocity at 1 AU from the Sun?

  • Kim, Jung-Hee;Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Quite recently, it has been suggested that the interaction of the solar wind with Mercury results in the variation in the solar wind velocity in the Earth's neighborhood during inferior conjunctions with Mercury. This suggestion has important implications both on the plasma physics of the interplanetary space and on the space weather forecast. In this study we have attempted to answer a question of whether the claim is properly tested. We confirm that there are indeed ups and downs in the profile of the solar wind velocity measured at the distance of 1 AU from the Sun. However, the characteristic attribute of the variation in the solar wind velocity during the inferior conjunctions with Mercury is found to be insensitive to the phase of the solar cycles, contrary to an earlier suggestion. We have found that the cases of the superior conjunctions with Mercury and of even randomly chosen data sets rather result in similar features. Cases of Venus are also examined, where it is found that the ups and downs with a period of ~ 10 to 15 days can be also seen. We conclude, therefore, that those variations in the solar wind velocity turn out to be a part of random fluctuations and have nothing to do with the relative position of inner planets. At least, one should conclude that the solar wind velocity is not a proper observable modulated by inner planets at the distance of 1 AU from the Sun in the Earth's neighborhood during inferior conjunctions.

Determination of Weighting Factor in the Inverse Model for Estimating Surface Velocity from AVHRR/SST Data (AVHRR/SST로 부터 표층유속을 추정하기 위한 역행렬 모델에서 가중치의 설정)

  • Lee, Tae-Shin;Chung, Jong-Yul;Kang, Hyoun-Woo
    • 한국해양학회지
    • /
    • v.30 no.6
    • /
    • pp.543-549
    • /
    • 1995
  • The inverse method has been used to estimate a surface velocity field from sequential AVHRR/SST data. In the model, equation system was composed of heat equation and horizontal divergence minimization and the velocity field contained in the advective term of the heat equation, which was linearized in grid system, was estimated. A constraint was the minimization of horizontal divergence with weighting factor and introduced to compensate the null space(Menke, 1984) of the velocity solutions for the heat equation. The experiments were carried out to set up the range of weighting factor and the matrix equation was solved by SVD(Singular Value Decomposion). In the experiment, the scales of horizontal temperature gradient and divergence of synthetic velocity field were approximated to those of real field. The neglected diffusive effect and the horizontal variation of heat flux in the heat equation were regarded as random temperature errors. According to the result of experiments, the minimum of relative error was more desirable than the minimum of misfit as the criteria of setting up the weighting factor and the error of estimated velocity field became small when the weighting factor was order of $10^{-1}$

  • PDF