• 제목/요약/키워드: regenerator

검색결과 146건 처리시간 0.031초

고온 초전도 회전자 냉각을 위한 탑재형 맥동관 냉동기 연구 (Investigation on-board pulse tube refrigerator for high temperature superconducting rotor)

  • 남중원;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.316-319
    • /
    • 2003
  • Cryogenic refrigerator system is necessary for cooling the superconducting rotor. Among the various cryogenic refrigerator systems, on-board hybrid pulse tube cryocooler is designed for cooling the superconducting rotor. Hybrid pulse tube cryocooler is composed of pulse tube cryocooler and Stirling cryocooler. This Stirling cryocooler precools the middle point of regenerator to obtain lower temperature at cold part of pulse tube cryocooler. In this paper, only Stirling cryocooler is on-boarded then rotated by motor for various rotating speeds and heat loads at cold part of Stilting cryocooler. Through this experiment the feasibility of the on-board cryocooler is investigated.

  • PDF

차세대 신형원자로의 피동형 안전 주입장치를 위한 프리피스톤 스터링 펌프의 동특성 모델 (Dynamic Modeling of the Free Piston Stirling Pump for the Passive Safety Injection of the Next Generation Nuclear Power Plant)

  • Lee, Jae-Young
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.149-154
    • /
    • 1999
  • This paper describes a passive safety injection system with free piston Stirling pump working withabundant decay heat in the nuclear reactor during the hypothetical accident. The water column in the tube assembly connected from the hot chamber to the cold chamber in the pump oscillates periodically due to thermal volume changes of non-condensable gas in each chamber. The oscillating pressure in the water column is converted into the pumping power with a suction-and-bleed type valve assembly. In this paper a dynamic model describing the frequency of oscillation and pumping pressure is developed. It was found that the pumping pressure is a function of the temperature difference between the chambers. Also, the frequency oscillation depends on the length of the tube with water column.

  • PDF

제동디스크 소재의 마찰-마모특성 시험 (A test for friction and wear characteristic of brake disk materials)

  • 임충환;구병춘
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1761-1765
    • /
    • 2008
  • In the braking of a railroad car, mechanical brake systems using wheel tread and brake disk are applied as well as electrical brake systems by regenerator and rheostat. It is very important to consider the frictional characteristic because kinetic energy of the vehicle is dissipated as converted thermal energy through friction between disk and brake pad during disk braking. A friction coefficient and wear characteristic are decided from the interrelationship of disk and friction material in the disk brake system. Lab-scale dynamometer test on developed brake disk materials for increasing heat resistance was performed in this study. Each candidate material was tested at various braking speeds and pressures and we obtained the friction coefficient and wear characteristic. And we executed comparative evaluation of the result from the test.

  • PDF

일체형 스터링 냉동기의 설계, 제작 및 성능특성에 관한 연구 (A study on the performance characteristics of rotary type Stirling cryocooler)

  • 박성제;홍용주;김효봉;김양훈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.54-58
    • /
    • 2006
  • Stirling cryocooler is relatively compact, reliable, commercially available. and uses helium as a working fluid. Over the past decade and a half, there has been rapid development of Stirling cryocooler, mainly for military and space applications. Stirling cryocoolers have been widely used lot the cooling of infrared sensors and high temperature superconducting filters to the temperature of the liquid nitrogen. The Stirling cryocooler with the rotary compressor is applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. In this paper, integral Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.6W cooling at 80K for 20W of input power from 24V DC power supply.

스털링 기관용 재생기에 관한 기초 연구(III) - 철선을 축열재로 한 재생기의 온도 분포와 압력 강하 특성 - (Basic Study on the Regenerator of Stirling Engine (III) - Temperature Distribution and Pressure drop property of the regenerator with steel wire -)

  • 김태한;오대건;이정택
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2002년도 동계 학술대회 논문집
    • /
    • pp.548-557
    • /
    • 2002
  • 본 연구는 스털링 기관의 성능에 가장 큰 영향을 미치는 재생기의 설계에 적합한 축열재를 찾을 목적으로 단일 철선 종류(ø0.7, ø0.9, ø1.2, ø1.6, ø2.0, ø2.7), 복합 철선 4종류 (ø1.6-ø1.2, ø1.2-ø1.6, ø0.9-ø1.2, ø1.2-ø0.9), 철망-철선을 서로 다르게 혼합한 축열재 8종류(150-ø0.9, 150-ø01.2, ø0.9-150, ø1.2-150, 150-ø0.9-150, 150-ø1.2-150, 150-ø1.6-150, 150-ø2.0-150)을 공시 축열재로 하여 스털링 기관의 운전조건과 동일한 왕복 유동 상태에서 축열재의 삽입 방법에 따른 온도 분포 및 압력 강하 특성에 관한 실험을 수 행한 결과를 요약하면 다음과 같다. 1. 단일 철선을 축열재로 사용한 경우, 재생기 양단의 온도차는 단일 철선의 직경이 작을수록 커지는 경향을 보였으나, 양단의 압력 차는 단일 철선의 직경이 커질수록 작아졌다. 단일 철선 ø0.7과 ø0.9의 성능은 이들 2종류의 공시 축열재의 성능을 비교하기 위하여 재생기 양단의 온도차 증가에 따른 기관의 압력증가량과 압력강하 곡선의 차를 비교한 결과, 거의 비슷함을 알 수 있었으며 최적치를 나타냈다. 2. 복합 철선 4종류의 경우, 가열부 쪽에 ø1.2, 냉각부 쪽에 ø0.9를 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차가 큰 반면, 압력 차는 적으므로 재생기 축열재로서 더 적합한 것으로 나타났다. 복합 철선을 사용할 경우 가열부 쪽보다 냉각부 쪽에 철선 직경이 작은 것을 삽입하는 것이 효과적임을 알 수 있다. 또한 철선의 직경이 큰 것의 조합보다는 직경이 작은 철선의 조합이 재생기 양단의 온도차가 큼을 알 수 있다. 3. 철망-철선 혼합재를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.

  • PDF

Effects of cyclic mean pressure of helium gas on performance of integral crank driven stirling cryocooler

  • Hong, Yong-Ju;Ko, Junseok;Kim, Hyo-Bong;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권3호
    • /
    • pp.30-34
    • /
    • 2016
  • An integral crank driven Stirling cryocooler is solidly based on concepts of direct IR detector mounting on the cryocooler's cold finger, and the integral construction of the cryocooler and Dewar envelope. Performance factors of the cryocooler depend on operating conditions of the cryocooler such as a cyclic mean pressure of the working fluid, a rotational speed of driving mechanism, a thermal environment, a targeted operation temperature and etc.. At given charging condition of helium gas, the cyclic mean pressure of helium gas in the cryocooler changes with temperatures of the cold end and the environment. In this study, effects of the cyclic mean pressure of helium gas on performances of the Stirling cryocooler were investigated by numerical analyses using the Sage software. The simulation model takes into account thermodynamic losses due to an inefficiency of regenerator, a pressure drop, a shuttle heat transfer and solid conductions. Simulations are performed for the performance variation according to the cyclic mean pressure induced by the temperature of the cold end and the environment. This paper presents P-V works in the compression and expansion space, cooling capacity, contribution of losses in the expansion space.

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권1호
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

Experimental results of Stilting type Pulse Tube refrigerator with inertance tube

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong;Park, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.118-122
    • /
    • 2003
  • Pulse tube refrigerator, which has no moving parts at its cold section, is attractive fer obtaining higher reliability, simpler construction and lower vibration than Stilting refrigerator or Gifford-McMahon refrigerator. Commonly used means to achieve optimum performance of Stilting type pulse tube refrigerator is an inertance tube. The use of inertance tube is a simple way to generate the phase shift needed to make pulse tube refrigerator operate as efficiently as Stilting refrigerator. In this study, the performance of the inertance pulse tube refrigerator (IPTR) was investigated experimentally. An in-line type IPTR consists of a linear compressor with two reciprocating pistons driven by linear motors, which makes pressure waves, a regenerator a pulse tube with the inertance tube, and a reservoir, The dynamic pressures (the compressor, pulse tube, reservior) and the temperature at the cold heat exchanger are measured to explore the dependence of the inertance tube on the performance of the IPTR. The experimental results show the dependency of cool-down characteristics, no-load temperature and amplitude of the pressures on the length and diameter of the inertance tube.

태양열 온수기를 이용한 다목적 공조시스템의 재생효율에 관한 연구(제1보 액체흡수제 온도가 재생량에 미치는 영향) (Research on the Performance of Regenerator using Hot Water from Solar Water Heater(1st paper : On the Effect of Solution Temperature to Regeneration Rate))

  • 우종수;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제24권1호
    • /
    • pp.53-61
    • /
    • 2004
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an efficient solar water heater, this study examines a regeneration process using hot water obtained from solar water heater to recover absorption potential by evaporating moisture in the liquid desiccant. In this paper, a solar absorption dehumidifying system with solar water heater is suggested to save the electricity for operating an air conditioner. LiGl(lithium chloride) solution was adopted as a liquid desiccant in the proposed system, and hot water obtained from the solar water heater was used for regenerating the liquid desiccant. As a result, it was clear that the dilute LiCl solution could be regenerated by hot water, and the regeneration rate depends mostly on temperature level of liquid desiccant. The regeneration rates were about 2.4kg/h with $40^{\circ}C$, 4.0kg/h with $50^{\circ}C$, and 6.2kg/h with $60^{\circ}C$ of hot water respectively.

$\alpha$형 스터링 엔진의 최적 설계 조건 (A Study on the Theoretical Analysis and Optimal Design Conditions for the $\alpha$ type Stirling Engine)

  • 강문규;이택희;유재환
    • 한국안전학회지
    • /
    • 제13권4호
    • /
    • pp.142-154
    • /
    • 1998
  • A stirling engine is a mechanism used to convert heat to power and operates on a closed regenerative thermodynamic cycle with compression and expansion of the working fluid at different temperature. The performance of a stilting cycle machine is a function of six independent parameters, namely; (1) speed N(r.p.m), (2) pressure of the working fluid p(Pa), (3) ratio of the temperature in the compression and expansion space ${\tau}(=T_C/T_E)$ , (4) ratio of the swept volumes in these two spaces K, (5) phase angle $\alpha$ and (6) dead volume ratio X. This paper describes the procedure and presents the results of computations carried out to establish the optimum combinations of these six parameters for maximum engine output for the machine acting as a prime mover, over a combined temperature range from $300^{\circ}K$ to $1000^{\circ}K$ and dead volume ratio X ranging from 0.1 to 2.0. The output of a stilting cycle machine can be expressed in terms of nondimensional power in several different ways. Four methods were studied in detail, the parameters optimized and design charts and engine power charts prepared. The results of this paper may be useful as a guide to the likely effects on the performance of some of the important design parameters and regenerator design.

  • PDF