• Title/Summary/Keyword: refraction test

Search Result 130, Processing Time 0.025 seconds

Case Study of the Shallow Seismic Refraction Survey using Wave Glider (웨이브글라이더를 이용한 천해저 탄성파 굴절법 탐사 사례)

  • Kim, Young-Jun;Cheong, Snons;Koo, Nam-Hyung;Chun, Jong-Hwa;Kim, Jeong-Ki;Hwang, Kyu-Duk;Lee, Ho-Young;Heo, Sin;Moon, Ki-Don;Jeong, Cheol-Hun;Hong, Sung-Du
    • Geophysics and Geophysical Exploration
    • /
    • v.20 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • The applicability of refraction survey has been tested using a wave glider widely used in long-term ocean observations around the world. To record seismic refractions, a single channel streamer with metal weight and a seismic recording system were mounted on the wave glider. We used GPS precise time synchronization signal and radio frequency (RF) communication to synchronize shot and recorder triggers and to control acquired data quality in real time. When the wave glider is positioned close to the set point, a 2,000 J sparker is exploded along the designed track at 2 second intervals. Through the test survey, we were able to successfully acquire refractions from the subsurface.

Diurnal fluctuations of vision in myopes (근시안의 일일 시럭변동에 관한 연구)

  • Park, Sang-Chul;Sung, A-Young;Kim, Tae-Hyun;Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2005
  • Subjective and objective visions were measured on young adults(mean 21 yrs, 126 eyes) who were free of any ocular diseases and laser surgery and none wore contact lenses. The aim of this study was to investigate the diurnal variation of vision through subjective and objective measurements. Subjective visual acuity were measured at 5 m three times a day, morning(8:00 AM-10:00 AM), noon(12:00 PM-2:00 PM) and afternoon(4:00 PM-6:00 PM). The instrument used for objective refraction right after visual acuity measurement was Nvision-K 5001(shin-nippon) which unique in being able to disregard subject's accommodation because of its unrestricted viewing conditions. Also, we measured that three times and then calculated the average values. The result showed that an average subjective visual acuity in the morning, noon, afternoon were 0.256(${\pm}0.263$), 0.266(${\pm}0.276$), 0.242(${\pm}0.249$) respectively. Average spherical equivalent power in objective refraction of right eyes showed -3.416 D(${\pm}2.907$), -3.359 D(${\pm}2.735$), -3.297 D(${\pm}2.709$) respectively and dioptric power was decreased from morning to afternoon. Vision changed throughout the day in both subjective and objective measurements nevertheless its variations were statistically insignificant(p<0.05). Therefore it does not seem to matter of time for either visual acuity test or refraction.

  • PDF

The Relationship between Refractive Myopia and Corneal Astigmatism in Korea Women University Students (한국 여자대학생의 굴절성 근시와 각막난시 관계)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose. To analysis the prevalence of the myopia and corneal astigmatism in Korea women university students. Methods. From August 2011 to December 2012, one hundreds subjects were performed in refraction test using the Auto-Keratometry. Results. The mean age of the 100 subjects (200 eyes) was $21.23{\pm}2.34$. The mean spherical refractive power was -$1.78{\pm}1.65$(OD) and -$1.83{\pm}1.67$(OS) Diopter. The mean astigmatism power was $1.22{\pm}0.96$ (OD) and $1.27{\pm}0.91$ (OS). The mean corneal astigmatism was $1.44{\pm}0.81$(OD) and $1.55{\pm}0.93$(OS). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5%. There was a statistical significance between right eye and left eye in the spherical equivalent power(p=0.002). Also there was a statistical significance between spherical power and refractive astigmatism in OD(p=0.006) and OS(0.003) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.0003). However, there was not a statistical significance between spherical power and corneal astigmatism in OD(p=0.08) and OS(0.1) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.48). Conclusions. In this study, these results suggested that the analysis of the refractive myopia and corneal astigmatism can provide the visual correct and useful diagnosis information for the eyewear dispensing, contact lens fitting and corneal refraction surgery.

  • PDF

The Efficacy and Safety of Periocular Acupoint Stimulation on Myopia Progression in Children: A Study Protocol (소아근시에 대한 눈 주위혈 지압의 유효성 및 안전성 평가 연구)

  • Cha, Ho yeol;Jung, A Ram;Cheon, Jin Hong;Choi, Jun Yong;Kim, Ki Bong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.12-22
    • /
    • 2015
  • Objectives Myopia has a higher prevalence rate in eastern countries, which also have a higher rate of educational fever compared to western countries. Considering this, social costs paid for myopia will increase rapidly in Korea. Although the development of myopia treatment is necessary, there has been a lack of relevant studies. Thus, this study aims to produce data to prevent unnecessary treatments and medical expenses. Methods The objective is to evaluate the effect of periocular acupressure exerted by a medical massager for myopia. This is an open-label, prospective, single-arm, and pre and post superiority study. The subjects are 7~12-year-old myopia patients with under 5 D (diopter) of spherical equivalent. A total of 56 subjects were enrolled. The selected subjects will wear the massager for 15 minutes twice a day for 24 weeks. The primary endpoint is the refraction change. The secondary endpoint is the axial length change. Statistical analysis was performed at a significant level of 0.05, using a two-tailed test. The criterion for significantly improved refraction was $-0.17{\pm}0.50$ D/6 months and that of axial length change was 0.126 mm. Results and Conclusions This study did not include a control group because children represent a vulnerable group. This objective study will bring some impact on Korean medical myopia treatment. A long-term confirmatory clinical study may be necessary in future.

Fabrication of Planar Type Optical Waveguide for the Application of Biosensor and Detection Characteristics of Staphylococcus Aureus (바이오센서용 평판형 광도파로 센서 제작 및 황색포도상구균 검출 특성)

  • Kim, Jun-Hyong;Yang, Hoe-Young;Yu, Chong-Hee;Lee, Hyun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.223-223
    • /
    • 2009
  • In this paper, designed and simulated Power Splitter (PS) integrated Mach-Zehnder interferometer (MZI) based planar type optical waveguide devices (which is called here a PS-MZI). The PS-MZI optical waveguide sensor was preceded by a Y-junction, which splits the input power between the sensor, and a reference branch, to minimize the effect of optical power variations. The PS-MZI optical waveguide sensor induced changing phases of the incident beam, which had fallen upon the waveguide through computer simulation, according to the small changes in the index of refraction, thus beam intensity was changed. The waveguide were optimized at a wavelength of 1550 nm and fabricated according to the design rule of 0.45 delta%, which is the difference of refractive index between the core and clad. The fabrication of PS-MZI optical waveguide sensor was performed by a conventional planar lightwave circuit (PLC) fabrication process. The PS-MZI optical waveguide that was fabricated to be applied as a biosensor revealed a low insertion loss and a low polarization-dependent loss. After having etched the over-clad at the sensor part in the MZI optical waveguide that was fabricated, Ti deposition was made on the adhesion layer, and then Au thin-film deposition was carried out thereon. In addition, its optical properties were measured by having changed the index of refraction oil at the sensing part of the MZI. To apply the planar type PS-MZI optical waveguide as a biosensor, a detection test for Staphylococcus aureus was conducted according to changes in concentration, having adopted Ti-alkoxide as ligand. The detection result of the S. aureus by the PS-MZI optical waveguide sensor was possible to the level of $10^1$ CFU/ml.

  • PDF

The Study of the Abnormal Refraction Eye on the Women Middle and High school Students (여자 중·고등학생들의 굴절이상 눈에 대한 연구)

  • Kim, Douk-Hoon;Shin, Jang-Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.135-140
    • /
    • 1999
  • To investigate the visual acuity of the women middle and high school students, the visual acuity test was performed the object and subject methods. The results were as follows; 1. The eye types were 96.7% positive for myopia, 2.5% for emmetropia, and 0.8% for hyperopia, respectively. 2. The abnormal refraction eyes were 61% positive for simple myopia, 35.2% for myopitic compound astigmatism, 3% for myopic simple astigmatism, and 0.8% for simple presbyopia, respectively. 3. The asix of astigmatism were 95% positive for irregular astigmatism axis, 3% for regular astigmatism axis, and 2% for oblique astigmatism axis, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF

Classification of Rock Mass on Cutting Slopes in Muakjae, Seoul (서울 무악재 절취사면에서의 암판정 연구)

    • Tunnel and Underground Space
    • /
    • v.9 no.2
    • /
    • pp.158-167
    • /
    • 1999
  • There are substantial difficulties in assessing the volume of soill/rock to be excavated and the cost thereof, which is attributable to the subjective and qualitative methods of rock mass classification prevailing at the moment. This paper intends to introduce more objective and quantitative rock mass classification method easily applicable to the excavation of granites in Muakjae, Seoul. As a result of such study it is proven that Schmidt hammer and point load strength tests are fairly reliable and easily applicable to estimate and quantify uniaxial compressive strength of granitic material in Seoul. In an efforts to confirm the granitic rock mass conditions in 12 meters underground, seismic refraction surveys were made on the top of vertical exposures from where underlying rock mass conditions could be directly inspected. Rock mass boundaries determined by seismic refraction methods were found to agree within a 1m variance with visible differences in rock mass conditions in the vertical exposure beneath the test site. Thus it can be concluded that detailed geotechnical mapping on cutting slopes is a most efficient, dependable and cost-effective technique in assessing likely excavation conditions of shallow granitic mass in Seoul.

  • PDF

Analysis of Refractive Error according to Aging in Young Children in South Korea (한국 어린이의 연령에 따른 굴절이상 분석)

  • Kim, Douk-Hoon;Kim, Dae-Nyoun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose. to describe the prevalence of refractive error according to aging in young children in South Korea. Methods : From July 2013 to June 2014, five hundred subjects( 250 male subjects, 250 female subjects; aged between 7 and 12 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+2.00$ D, cylinder error ${\geq}0.75$ D and SE difference${\geq}1.00$ D between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 80.41%, astigmatism 44.89%, emmetropia 18.27%, anisometropia 16.92%, and hyperopia 1.32%. The prevalence of myopia increased with age. but hyperopia was decrease. Myopia and astigmatism were much more common in male than females although the difference was not statically significant. Emmetropia and hyperopia were much more common in female than males although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to 0.99 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between 9 year and 10 year of female in the spherical equivalent power(p>0.05). In all another group of age, there was not a statistical significance as aging in spherical equivalent power(p>0.5). However, there was a statistical significance between male and female as age in the spherical equivalent power(P>0.01). Conclusions: Myopia was the most common refractive error in Korea young children, while hyperopia was decreased after 7 years. There was a statistical significance as age between male and female at spherical equivalent power(P> 0.01). these results suggested that the analysis of the refractive error as age at young children can give the useful diagnosis data for the correction of visual function.

Development of underwater 3D shape measurement system with improved radiation tolerance

  • Kim, Taewon;Choi, Youngsoo;Ko, Yun-ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1189-1198
    • /
    • 2021
  • When performing remote tasks using robots in nuclear power plants, a 3D shape measurement system is advantageous in improving the efficiency of remote operations by easily identifying the current state of the target object for example, size, shape, and distance information. Nuclear power plants have high-radiation and underwater environments therefore the electronic parts that comprise 3D shape measurement systems are prone to degradation and thus cannot be used for a long period of time. Also, given the refraction caused by a medium change in the underwater environment, optical design constraints and calibration methods for them are required. The present study proposed a method for developing an underwater 3D shape measurement system with improved radiation tolerance, which is composed of commercial electric parts and a stereo camera while being capable of easily and readily correcting underwater refraction. In an effort to improve its radiation tolerance, the number of parts that are exposed to a radiation environment was minimized to include only necessary components, such as a line beam laser, a motor to rotate the line beam laser, and a stereo camera. Given that a signal processing circuit and control circuit of the camera is susceptible to radiation, an image sensor and lens of the camera were separated from its main body to improve radiation tolerance. The prototype developed in the present study was made of commercial electric parts, and thus it was possible to improve the overall radiation tolerance at a relatively low cost. Also, it was easy to manufacture because there are few constraints for optical design.

The Analysis of the State of Successful Refractive Surgery's Eye (성공적인 굴절교정수술자 안구상태분석에 대한 연구)

  • Jang, Woo-Yeong;Lee, Jeong-Yeong;Park, Jeong-Sik
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.223-230
    • /
    • 2014
  • Purpose. Scheduled calibration of refractive error's have various refractive surgery, and a side effect of post refractive surgery for refractive errors's before refractive surgery, by analyzing the eye condition of the refractive error's good state, it tries to increase the satisfaction of refractive error's refractive surgery. Methods. In response to 60 people preoperative data 20-30 generations of age, were analyzed for eye conditions. Results. IOP, thickness of the cornea, liquid leakage amount inspection, the corneal endothelium inspection, the size of the pupil, have been conducted auto refraction test and showed a numerical value in most normal range. Conclusion. Surgery can be of individual differences of patients, it is difficult to define the full normal range, to the surgery based on the case of this study, the side effects of patients after surgery is expected to be prevention.