• Title/Summary/Keyword: reference value

Search Result 2,286, Processing Time 0.032 seconds

Design of Low-Voltage Reference Voltage Generator for NVM IPs (NVM IP용 저전압 기준전압 회로 설계)

  • Kim, Meong-Seok;Jeong, Woo-Young;Park, Heon;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.375-378
    • /
    • 2013
  • A reference voltage generator which is insensitive to PVT (process-voltage-temperature) variation necessary for NVM memory IPs such as EEPROM and MTP memories is designed in this paper. The designed BGR (bandgap reference voltage) circuit based on MagnaChip's $0.18{\mu}m$ EEPROM process uses a low-voltage bandgap reference voltage generator of cascode current-mirror type with a wide swing and shows a reference voltage characteristic insensitive to PVT variation. The minimum operating voltage is 1.43V and the VREF sensitivity against VDD variation is 0.064mV/V. Also, the VREF sensitivity against temperature variation is $20.5ppm/^{\circ}C$. The VREF voltage has a mean of 1.181V and its three sigma ($3{\sigma}$) value is 71.7mV.

  • PDF

Reference Value of Mercury in Liver and Kidney of Korean (한국인의 간과 콩팥조직 내 수은 함유량의 참고치)

  • 최병선;박영주;권일훈;홍연표;박정덕
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.109-115
    • /
    • 2002
  • This study was conducted to investigate the reference value of mercury (Hg) in liver and kidney of Korean population. The mercury concentration in 244‘sudden and unexpected death’autopsies (male: 180, female: 64) aged from 0 to 87 years was analyzed. The concentration of mercury was measured by atomic absorption spectrophotometer (Perkin-Elmer Model 5100) with mercury/hydride generating system (FIAS 400). The contents of mercury in liver and kidney fitted well the log-normal distribution rather than normal distribution. Geometric mean concentration of mercury in liver and kidney was 0.115 $\mu\textrm{g}$/g wet weight and 0.149 $\mu\textrm{g}$/g wet weight, respectively. Geometric mean concentration of mercury in female was higher than in male (p < 0.01). The mercury content in liver and kidney increased with age up to the forties and slightly decreased there-after. The regression model of mercury deposit in liver and kidney by age was predicted as the following equation : Log LHg : -1.0576+0.0045$.$Age-0.0001$.$Age$^2$+0.0873$.$Sex, Log KHg = -1.0576+0.0152$.$Age-0.0002$.$Age$^2$+0.1935$.$Sex. The liver burden of mercury was estimated to be 158.3∼161.3 $\mu\textrm{g}$ in male and 163.0∼166.9 $\mu\textrm{g}$ in female. The kidney burden of mercury was estimated to be 42.0∼42.9 $\mu\textrm{g}$ in male and 55.5∼57.1 $\mu\textrm{g}$ in female.

The Application of New Calibrator[I-125]Set for Equipment Quality Management (장비정도관리에 Calibrator[I-125] Set 적용)

  • Kim, Ji-Na;An, Jae-seok;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.108-111
    • /
    • 2015
  • Purpose Lately, in accordance with the increasing interest about Healthcare accreditation program and International laboratory accreditation scheme, requirements about the instrument quality management are gradually taking shape. In nuclear medicine In vitro laboratory, the most typical instruments are multi detector gamma counter and automatic dispensing system. Each laboratory continue with the quality control adequate for circumstances. The purpose of this study is to application and establish the new Calibrator[I-125]Set which is efficient at standardization of equipment quality management. Materials and Methods Deviation between detectors were measured with 12 solid samples of the Calibrator[I-125]Set. their activities differ from each other by less than 1%. Multi detector gamma counters are GAMMA-10;Shinjin medics. Inc, Goyansi, Korea(Gamma counter A), SR300;Stratec biomedical systems AG, Gewerbestr, Germany(Gamma counter B) and COBRA II; Packard Instrument Co. Inc, Meriden, USA(Gamma counter C). Evaluation of two automatic dispensing system used A, B liquid tracer of the Calibrator[I-125]Set. After dispensing and counting, calculated using the ratio of the measured value and proposed value. We used solution A for 20, 25ul and solution B for 50, 100ul. Method of data analysis and reference range was provided by kit documentation. Furthermore, we could calculate our counter efficiency indirectly. Results The CV(%) of measured values by Gamma counter A, B, C are 0.34, 0.70, 1.30. Calculated value are 1.05314, 2.10419, 4.08485. Provided reference range is less than 3. A dispensing system's calculated values are 0.986, 0.989, 1.023, 1.017 and B are 0.874, 0.725, 1.021, 0.904. Provided reference range is from 0.95 to 1.05. Also, counter's efficiency are 74.18, 72.79, 74.32% at counter A, B, C and efficiency of the one detector counter is 79.26%. Conclusion If using this Calibrator[I-125]Set after verifying whether quality assurance, is applicable to equipment quality management on behalf of the role of gold standard.

  • PDF

Growth Characteristics of Creeping bentgrass Cultivars (크리핑 벤트그래스 품종의 생육 특성)

  • 이혜원;정대영;심상렬
    • Asian Journal of Turfgrass Science
    • /
    • v.17 no.2_3
    • /
    • pp.87-97
    • /
    • 2003
  • The growth characteristics of creeping bentgrass seeded in the seaside landfill golf course are as follows. 1. As a result of analysis on the chemical characteristics of soil mixture used for turfgrass ground in this experiment, soil pH was 7.9, which is somewhat higher than the creeping bentgrass reference value of pH 5.5∼6.5; T-N(%) was 0.02, which is proper for the reference value, and trace element too lacked. 2. The cultivar with the fastest water infiltration was Seaside II recorded as 226.2cm/sec, while that with the slowest water infiltration was Pennlinks recorded as 141.1 cm/hr which was too faster than the USGA water infiltration reference value of 15∼30cm/hr. For the surface hardness of turfgrass ground with different cultivars, no statistically significant variation was found between the Penncross grass and the Pennlinks recorded as 18.6mm and 19.1 mm, respectively. The soil penetration was the highest in Pennlinks recorded as 7.6kg/$\textrm{cm}^2$ and lowest in Penn A-1 as 6.1kg/$\textrm{cm}^2$. 3. As a result of evaluation on visual quality at the early stage of growth, Penncross showed the most excellent visual quality compared to the others. However, Penn A-1 showed the most excellent visual quality at a late stage of growth around Sep. 17, 2003, and it was also excellent in the evaluation of visual color. Seaside II showed higher density around the root and the longest root length and was highly resistant to salt compared to others, but the initial sprouting rate was not satisfied, and the visual quality in the summer season was inferior to others. 4. As a result of measurement of the traffic injury, Penncross showed the most tolerant to the traffic stress and Pennlinks showed the most susceptible.

Optimization of the Spreadable Modified Butter Manufacturing by Response Surface Methodology

  • Suh, Mun Hui;Lee, Keon Bong;Baick, Seung Chun
    • Food Science of Animal Resources
    • /
    • v.32 no.6
    • /
    • pp.783-788
    • /
    • 2012
  • The aim of this study was to optimize the manufacturing condition of spreadable modified butter by RSM. Based on the central composite design, the degree of optimization was expressed as a SFC as a dependent variable (Y, %) determined by NMR with 23 experimental groups. Three independent variables were the contents of butter ($X_1$, 35-75%), the contents of grape seed oil ($X_2$, 15-35%), and the contents of hydrogenated soybean oil ($X_3$, 0-4%). As the result, SFC at $10^{\circ}C$ was ranged from 32.37 to 42.76%. In addition, the regression coefficients were calculated for SFC at $10^{\circ}C$ by RSREG. The regression model equation for the SFC was $Y=39.18-0.04X_1X_3$. Consequently, the optimal contents for manufacturing spreadable modified butter were determined as 55.18% for butter, 40.78% for grape seed oil, and 4.08% for hydrogenated soybean oil, respectively. The predicted response value for SFC at $10^{\circ}C$ was 30.20%, comparable to the actual experimental SFC value as 29.85%. Finally hardness and spreadability in reference butter and spreadable modified butter produced under the optimal conditions was measured. The hardness in spreadable modified butter was 31.80 N as compared to 69.92 N in reference butter. The spreadability in spreadable modified butter was 5.6 point as compared to reference butter. This difference may be due to the contents of solid fat by butter and hydrogenated soybean oil. This study showed that the SFC value at $10^{\circ}C$ could be a suitable indicator for the manufacturing spreadable modified butter to predict important attributes such as mouth feel, hardness and spreadability.

Development of a Screw-Crane System for Pre-Lifting the Sternal Depression in Pectus Excavatum Repair: A Test of Mechanical Properties for the Feasibility of a New Concept

  • Park, Hyung Joo;Rim, Gongmin
    • Journal of Chest Surgery
    • /
    • v.54 no.3
    • /
    • pp.186-190
    • /
    • 2021
  • Background: Pre-lifting of the sternum marked a major turning point in pectus excavatum repair. The author developed the crane technique in 2002 and successfully applied it to more than 2,000 cases using sternal wire stitching. However, blind sternal suturing limited the use of the wire-stitch crane. We propose a novel screw for sternal lifting as a new tool for the crane technique. Methods: We developed a screw system strong enough to withstand the pressure needed for sternum lifting. The screw was designed to have a broader thread to hold the bony tissue securely. The screw's sustaining power was tested using the torsion, driving torque, and axial pull-out tests in a polyurethane block and ex-vivo porcine sternum. Results: The screws were easily driven into the sternum, and the head of the screw was connectable to the table-mounted retractor. In the torsion test, the 2° offset torsional yield was 4.53 N·m (reference value, 1 N·m). In the polyurethane block driving torque test, the maximum torque was 0.98 N·m (reference value, 0.70 N·m). The axial pull-out test was 446 N (reference value, 100 N). The maximum pull-out resistance in the ex-vivo porcine sternum model was 1,516 N. Conclusion: The screw crane was strong enough to sustain the chest wall weight to be lifted. Thus, the screws could effectively replace the sternal wire stitching in crane pre-lifting of the sternum. We expect that application of the screw-crane will be easy and that it will improve the safety and success rate of pectus repair surgery.

Study on the Tiered Applicability of Health-Based Reference Value in Chemical Risk Assessment (화학물질 위험성 평가 시 건강영향 기준값의 단계적 적용에 관한 고찰)

  • Hye Jin, Lee;Naroo, Lee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.350-358
    • /
    • 2022
  • Objectives: For chemical risk assessment in workplaces, it is necessary to determine a reference value through hazard assessment. In general, OEL (Occupational Exposure Limit) is used for this value. However, since chemicals with OEL were not enough, the concept of DNEL (Derived No Effect Level) was introduced in chemical safety assessment. In this study, the possibility and approach of applying DNEL for chemical risk assessment in domestic workplaces were investigated. Methods: The characteristics of OEL and DNEL were investigated. In addition, ACGIH TLV and GESTIS DNEL were compared and the corresponding scopes were analyzed among the chemical substances notified in South Korea. Results: OEL and DNEL are similar concepts reflecting reference values that should not be exposed based on health effects. While their evaluation and derivation are determined based on similar information and procedures, they may vary depending on the responsible actor, data availability, principles of judgment, and more. As a result of the comparative analysis of ACGIH TLV and GESTIS DNEL, it was confirmed that there is some correlation between TWA and DNEL. The conservatism of DNEL was around 50%. Additionally, it was found that the available range of DNEL among chemicals in South Korea is considerable. Conclusions: This study showed that DNEL can be applied when assessing the risk of chemical substances in domestic workplaces considering several regards. However, since this is not the same level as OEL, we have proposed a proper approach to carry out risk assessment step by step.

The Study of Dosages of Herbal Medicine Including Aconiti Lateralis Preparata Radix and Aconiti Tuber on Aspartate Aminotransferase, Alanine Aminotransferase (부자(附子) 및 천오(川烏)를 포함한 처방이 혈중 Aspartate Aminotransferase, Alanine Aminotransferase 수치에 미치는 영향)

  • Han, Hyun-Young;Hwang, Won-Duk
    • The Korea Journal of Herbology
    • /
    • v.24 no.4
    • /
    • pp.87-93
    • /
    • 2009
  • Objectives : Aconiti Lateralis Preparata Radix (附子) and Aconiti Tuber (川烏) are not commonly prescribed, but are necessary for some clinical conditions, despite of the fact that some negative effects have been known to occur with these medicines. This study shows the consequences for aspartate aminotransferase (AST), alanine aminotransferase (ALT) due to herbal medicines, including Aconiti Lateralis Preparata Radix (附子) and Aconiti Tuber (川烏). Methods : From 1st June 2007 to 10th May 2009, the results were analyzed for 64 patients belonging to the OO Oriental Medical Hospital who took herbal medicine, including Aconiti Lateralis Preparata Radix (附子) and Aconiti Tuber (川烏), more than 20 days. This is the study about the comparison and the investigation of AST, ALT. And the results were taken upon their hospitalization and to their departure. The Criteria of Diagnosis in Liver Injury of CIOMS was used as a standard for their examinations. Results : AST, ALT (total 64). The number of patients who were within normal reference value : 49. The number of patients who exceed the normal reference value after dosage, without satisfying the Criteria of Diagnosis in Liver Injury : 5. The number of patients who were recovered in normal reference value after dosage : 9. The number of patients who satisfying the Criteria of Diagnosis in Liver Injury after dosage : 1. Conclusions : This results suggest that these herbal medicines, including Aconiti Lateralis Preparata Radix (附子) and Aconiti Tuber (川烏), didn't cause adverse side-effects on AST, ALT of the patients who are taking them.

Estimation of Fluid Saturations Using Agarose Standard in NMR Imaging (자기 공명 영상법에서 Agarose 표준 물질을 사용한 유체 포화도의 계산)

  • Kim, Kyung-Hoe
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.160-165
    • /
    • 1999
  • Agarose gels can be used as reference standards for the measurement of fluid properties in porous media because the relaxation properties of the gel reference standard and those of the fluid in porous media can be closely matched. The use of reference standard to determine porosity and saturation is discussed and the requirements for gel NMR properties given. The relaxtion times of agarose gels measured at 2.0 Tesla are illustrated as a function of agarose and paramagnetic impurity ($CuSO_4$) concentrations. This work shows an empirical result between agarose gel composition and gel relaxtion times. The average value for the porosity distribution is 17.7%, which compares well with the value calculated with the gravimetric analysis. Finally, two phase immiscible displacement using agarose gels as a reference standard was performed. The saturation profiles appear to be consistent with what one might calculate for a one-dimensional displacement in a uniform porous media.

  • PDF

Stepwise Inertial Control of a Doubly-Fed Induction Generator to Prevent a Second Frequency Dip

  • Kang, Mose;Lee, Jinsik;Hur, Kyeon;Park, Sang Ho;Choy, Youngdo;Kang, Yong Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2221-2227
    • /
    • 2015
  • To arrest a frequency nadir, a stepwise inertial control (SIC) scheme generates a constant active power reference signal of a wind turbine generator (WTG) immediately after a disturbance and maintains it for the predetermined time. From that point, however, the reference of a WTG abruptly decreases to restore the rotor speed for the predefined period. The abrupt decrease of WTG output power will inevitably cause a second frequency dip. In this paper, we propose a modified SIC scheme of a doubly-fed induction generator (DFIG) that can prevent a second frequency dip. A reference value of the modified SIC scheme consists of a reference for the maximum power point tracking control and a constant value. The former is set to be proportional to the cube of the rotor speed; the latter is determined so that the rotor speed does not reach the minimum operating limit by considering the mechanical power curve of a DFIG. The performance of the modified SIC was investigated for a 100 MW aggregated DFIG-based wind power plant under various wind conditions using an EMTP-RV simulator. The results show that the proposed SIC scheme significantly increases the frequency nadir without causing a second frequency dip.