• 제목/요약/키워드: reference value

검색결과 2,240건 처리시간 0.032초

A Study on Optimum Value of Design Parameter of Multivariate EWMA and CUSUM charts for Monitoring Dispersion Matrix

  • Chang, Duk-Joon
    • 통합자연과학논문집
    • /
    • 제14권3호
    • /
    • pp.116-122
    • /
    • 2021
  • Properties and comparison of multivariate CUSUM and EWMA charts for monitoring Σ of multivariate normal N(${\underline{\mu}}$, Σ) process has considered. Comparison of the performances of the considered charts, the numerical values are obtained by simulation with 10,000 iteration in terms of ATS, ANSS and ANSW. We found that EWMA chart with small values of smoothing constant more effectively detects the process changes than with large smoothing constant. And we also found that CUSUM chart with small value of reference value is more effectively detecting the process change than with large reference value. If a process engineer has interest in detecting small amount of shift rather than large shift, he/she can be recommended to use small smoothing constant in EWMA chart and small reference value in CUSUM chart.

해역의 환경특성을 고려한 해양환경 기준설정과 수질등급 평가 (Reference Values and Water quality Assessment Based on the Regional Environmental Characteristics)

  • 노태근;이동섭;이상룡;최만식;박철;이종현;이재영;김성수
    • 한국해양학회지:바다
    • /
    • 제17권2호
    • /
    • pp.45-58
    • /
    • 2012
  • 육상기인 오염원의 해양유입의 급속한 증가로 인해 유해성 적조발생이 빈번해졌을 뿐 아니라, 양식기술의 발달과 과밀양식으로 인해 연안역의 자가 오염증가가 가속화되고 있다. 따라서 해양환경 관리와 적절한 해역이용을 위해 과학적인 관리의 필요성이 증가하고 있다. 현행 환경기준은 일본의 해역 수질기준을 준용하여 육상의 배수기준에 희석 비율을 적용시켜 설정하는 공학적인 방식이다. 그리고 해역의 환경특성을 고려하지 않고 일률적인 값을 적용하였다. 유럽연합, 미국, 호주, 캐나다 등의 선진국에서는 이미 20여 년 전부터 종합적인 수질관리대책을 마련하고 있다. 따라서 본 연구에서는 우리나라 해양환경 특성에 적합한 수질평가 기준을 설정하기 위해 해역을 해류, 조석, 탁도 등을 기준으로 다섯 가지의 생태구로 구분하였다. 그리고 국가해양측정망의 관측항목 중에서 부영양화의 원인항목(용존 무기질소(dissolved inorganic nitrogen, DIN), 용존 무기인(dissolved inorganic phosphorus, DIP)과 일차반응항목(클로로필, Secchi depth)과 이차반응항목(저층용존산소포화도, bottom dissolved oxygen saturation)에 해당하는 항목들을 평가항목으로 선정하였다. 용존 무기질소, 용존 무기인과 클로로필의 기준값은 각각의 생태구에서 하천의 유입 영향이 최소인 외양역 정점의 2000년에서 2007년까지의 계절별 평균값 중 최대값으로 하였고, Secchi depth는 계절별 평균값 중 최소값을 선택하였다. 그리고 저층용존산소 포화도는 외양역의 평균값 중 최소포화도 값인 90%를 전체 생태구의 기준값으로 정하였다. 전체연안을 체계적이고 동일한 기준으로 관리하기 위해서 개별 평가항목의 점수로부터 원인항목, 일차반응 항목, 이차반응 항목 순으로 큰 가중치를 부여하는 가중선형합산 방식으로 수질지수를 계산하였다. 2000년부터 2007년까지 모든 정점에서 구한 수질지수의 분포는 최소값인 20과 중앙값이 30에서 빈도수가 높은 쌍봉분포가 나타났다. 따라서 수질지수의 쌍봉분포 앞부분에 해당하는 23이하를 매우좋음(I등급)으로 하였고 최소값+표준편차 이하를 좋음(II등급), 최소값+2표준편차 이하를 보통(III등급), 최소값+3표준편차 이하를 나쁨(IV등급), 그리고 최소값+3표준편차 초과일 때 아주나쁨(V등급)으로 정하였다.

A Reference Value for Cook's Measure

  • Lee, Jae-Jun
    • Communications for Statistical Applications and Methods
    • /
    • 제6권1호
    • /
    • pp.25-32
    • /
    • 1999
  • A single outlier can influence on the least squares estimators and can invalidate analysis based on these estimators. The Cook's statistic has been introduced to measure influence of individual data point on parameter estimation and the quantile of the F distribution is recommended as a reference value. but in practice subjective judgement is applied in the choice of appropriate quantile. A simple reference value is introduced in this paper which is developed by approximating conditional quantities of Cook's measure. The performance of the proposed criterion is evaluated through analysis of real data set.

  • PDF

반복측정의 불확도를 이용한 인증값 확인 (Confirmation of reference value using uncertainty of multiple measurements)

  • 최종오;소헌영;우진춘;황의진
    • 분석과학
    • /
    • 제15권6호
    • /
    • pp.580-583
    • /
    • 2002
  • New approach is developed employing the overall uncertainty obtained from multiple measurements to evaluate the statistical significance for the difference between a given reference value and its measured value determined in a lab. The overall uncertainty is determined by separate combinations of the uncertainties arising from systematic and random effects. It is shown that the uncertainty term in regular t-test can be underestimated by n measurements.

혈청 아밀로이드 P (SAP)의 정상 참고치 탐색을 위한 문헌 고찰 (Reference value of serum amyloid P : a systematic review)

  • 박선주;정지연;장수빈
    • 대한예방한의학회지
    • /
    • 제23권2호
    • /
    • pp.91-99
    • /
    • 2019
  • Objectives : The aim of this study was to examine the reference value of biomarker serum amyloid p (SAP) to diagnose blood stasis objectively. Methods : Pubmed-Medline, Cochrane library, EMBASE were searched using the key words 'SAP' and 'serum amyloid p' in June 2018. Original articles of human adults that published in English, studies that recruited from the clinical research settings or well defined population based cohorts were only included. Results : A total of 12 studies were selected to extract the reference value of SAP. It was between 8.5 ng/mL (0.0085 mg/L) to 57.5 mg/L. Although the disease varied, most of them showed elevated SAP levels in the disease group (1.1-1.5 times). Conclusions : This study is meaningful in that it summarizes the results of previous researches of SAP, which has the potential to be diagnostic index of blood stasis.

저압설비 플리커 특성평가를 위한 국내 저압계통 기준 임피던스 산정 연구 (A Study on the Calculation of Reference Impedances in Domestic Low-Voltage Power System)

  • 강문호;송양회;이흥호
    • 전기학회논문지
    • /
    • 제60권9호
    • /
    • pp.1651-1655
    • /
    • 2011
  • The reference impedances which is about 95% supply impedance value of residential consumers' supply impedances was published by IEC in 1980. The reference impedances are the standard values for use in determining the voltage disturbance characteristics of electrical equipment like the flicker. In IEC 60725, the reference impedances for premises having service current capacities less than 100A per phase and for service current capacities more than 100A per phase are recommended. And these reference impedances are targeted for the countries using 50Hz power frequency. Because of the frequency difference, the reactance values of the reference impedances will be increased in 60Hz power system like Korea, And also the reference impedances are different significantly each other according to declared voltage variation, power consumption and service wire length etc. Therefore It is needed to calculate the reference impedances suitable for domestic low-voltage power system. In this paper, the reference impedances for service current capacities less than 100A in 220/380V, 60Hz single-phase two wire and three-phase four wire low-voltage system are calculated, And the equations for service current capacities more than 100A to calculate the modulus value of maximum supply impedances are suggested base on IEC 60725 and the reference impedances for those are calculated on service current of 100A per phase.

Adaptive Shot Change Detection using Mean of Feature Value on Variable Reference Blocks and Implementation on PMP

  • Kim, Jong-Nam;Kim, Won-Hee
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.229-232
    • /
    • 2009
  • Shot change detection is an important technique for effective management of video data, so detection scheme requires adaptive detection techniques to be used actually in various video. In this paper, we propose an adaptive shot change detection algorithm using the mean of feature value on variable reference blocks. Our algorithm determines shot change detection by defining adaptive threshold values with the feature value extracted from video frames and comparing the feature value and the threshold value. We obtained better detection ratio than the conventional methods maximally by 15% in the experiment with the same test sequence. We also had good detection ratio for other several methods of feature extraction and could see real-time operation of shot change detection in the hardware platform with low performance was possible by implementing it in TVUS model of HOMECAST Company. Thus, our algorithm in the paper can be useful in PMP or other portable players.

  • PDF

CA 72-4 참고치 설정에 관한 연구 (A Study on Establishment of Reference Value of CA 72-4)

  • 안재석;김지나;조예지;윤상혁;김윤철
    • 핵의학기술
    • /
    • 제25권2호
    • /
    • pp.25-28
    • /
    • 2021
  • CA 72-4는 두 종류의 단일클론항체 CC49와 B72.3을 사용하여 혈청 내 종양관련단백인 TAG-72(tumor associated glycoprotein 72)를 측정 하여 결과를 나타내는 종양표지자이다. CA 72-4는 위암, 난소암, 췌장암등의 진단에 사용되고 있으며 특히 위암에 높은 특이도를 나타내는 것으로 알려져 있다. 본 연구는 CA 72-4의 참고치 재검증을 통하여 제조사에서 제공하는 참고치를 재평가 하고, 나아가 임상에서 보다 정확한 진단을 내리는데 유용한 도움을 주고자 진행하였다. 2020년 11월 국립암센터 건강검진센터에서 건강검진을 진행한 환자 271명을 대상으로 하였다. 대상자의 성별은 남자 140명 여자 131명 이었고, 30대부터 60대까지의 환자를 대상으로 진행하였다. 시약은 CA 72-4 IRMA KIT (ISOTOPES, Hungary)를 사용하였고, 감마카운터는 Dream Gamma-10(신진메딕스, Korea)을 사용하여 측정하였다. 종양표지자 참고치 설정 시 주로 사용하는 Hoffmann 법과 Bayesian 법으로 통계처리 하였다. 대상자 271명의 CA72-4를 측정한 결과 평균(Mean, M)값은 4.54 U/mL 이었고 중앙값(Median)은 3.30 U/mL 이었다. 3SD(standard deviation)를 벗어난 24명의 값을 제외하고 측정한 결과 M값은 3.53 U/mL, 중앙값은 3.00 U/mL, SD는 1.89 이었다. 이 값을 토대로 계산한 참고치 값은 7.31 U/mL 이었다. 제조사에서 제공되는 참고치는 4 U/mL 이하이며 이것은 본 연구에서 계산되어진 값인 7.31 U/mL과는 다소 차이가 있어 검사실 환경에 맞게 참고치 재설정이 필요해 보인다. 현재 국립암센터 위암센터에서는 지속적으로 현재 사용하고 있는 참고치에 관하여 문의가 오고 있다. 이번에 진행된 연구와 더불어 추가적인 연구를 진행한다면 보다 정확한 참고치 설정이 가능할 것이다.

Countermeasures of Specimens Showing below Reference Value in APTT Result

  • Choi, Hyun Oh;Kim, Seung Gu;Park, Sang Hee;Lee, Jae Ki;Koo, Bon Kyung;Park, Chang Ho
    • 대한임상검사과학회지
    • /
    • 제45권3호
    • /
    • pp.87-90
    • /
    • 2013
  • The activated partial thromboplastin time (APTT) is used primarily to evaluate coagulation abnormalities in the intrinsic pathway. The proper specimen is very important factor for precise results of blood coagulation analysis. The objective of this study was to get to the conclusion of whether to analyze again and to collect blood sample over again when APTT result shows below the reference value. We evaluated 126 samples showing a value below 20.0 sec at ATPT result, which consist of 48 males and 78 females candidates during night duty from March 2012 to December 2012. Average comparisons of APTT result between first and retested analysis among study subjects were significantly different in male samples. APTT results comparison of recollected subjects among clotted samples were also significantly different with both sexes (p<0.000). We suggest that we should carefully check the samples to get accurate results and collect samples again in case of only obtaining improper samples; even though the APTT result show below reference value.

  • PDF

한국 성인남성 표준인을 대상으로 한 방사성옥소($^{131}I$)의 S-value 도출 (S-value of Radioiodine($^{131}I$) in Korean Reference Adult Male)

  • 김정훈;임창선;황주호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권1호
    • /
    • pp.41-47
    • /
    • 2008
  • 한국 성인 남성 표준인(Korean Reference Adult Male)의 기초 자료를 이용하여 수학적 모의 피폭체(Mathematical Phantom)를 제작하였다. 또한 이를 이용하여 방사성옥소($^{131}I$)의 각 장기별 S-value를 산출 하였다. 산출된 S-value는 기존 ICRP-23표준인에 근거하여 산출한 MIRD 5, 및 ORNL-TM 8381자료와 비교해 보았다. 그 결과 S-value는 한국 성인 남성 표준인에 기초한 모의 피폭체가 높은 값을 나타냈다. 이는 몸통이라는 특수한 공간에 위치하게 되는 선원장기(source organ) 및 표적장기(target organ)가 함유하고 있는 구성물질도 중요하지만 그에 못지않게 이들이 차지하고 있는 위치 및 방사성핵종의 특성 또한 중요하게 작용한다는 것을 알 수 있었다.

  • PDF