• Title/Summary/Keyword: reference range

Search Result 1,775, Processing Time 0.029 seconds

A Target Tracking Based on Bearing and Range Measurement With Unknown Noise Statistics

  • Lim, Jaechan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1520-1529
    • /
    • 2013
  • In this paper, we propose and assess the performance of "H infinity filter ($H_{\infty}$, HIF)" and "cost reference particle filter (CRPF)" in the problem of tracking a target based on the measurements of the range and the bearing of the target. HIF and CRPF have the common advantageous feature that we do not need to know the noise statistics of the problem in their applications. The performance of the extended Kalman filter (EKF) is also compared with that of the proposed filters, but the noise information is perfectly known for the applications of the EKF. Simulation results show that CRPF outperforms HIF, and is more robust because the tracking of HIF diverges sometimes, particularly when the target track is highly nonlinear. Interestingly, when the tracking of HIF diverges, the tracking of the EKF also tends to deviate significantly from the true track for the same target track. Therefore, CRPF is very effective and appropriate approach to the problems of highly nonlinear model, especially when the noise statistics are unknown. Nonetheless, HIF also can be applied to the problem of timevarying state estimation as the EKF, particularly for the case when the noise statistcs are unknown. This paper provides a good example of how to apply CRPF and HIF to the estimation of dynamically varying and nonlinearly modeled states with unknown noise statistics.

Post-tuning of Sample Position in Common-path Swept-source Optical Coherence Tomography

  • Park, Jae-Seok;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.380-385
    • /
    • 2011
  • Common-path interferometers are widely used for endoscopic optical coherence tomography (OCT) because an arbitrary arm length can be chosen for the endoscopic imaging probe. However, the scheme suffers from the limited range of the sample position distance from the end of the imaging probe because the position between the reference reflector and the sample is limited by the optical path-length difference (OPD) to induce an interference signal. In this study, we developed a novel method for compensating the arbitrary sample position in common-path swept-source OCT by adding an extra Mach-Zehnder interferometer in the post-path of the interfered optical signal. Theoretical analysis and an experimental demonstration of imaging depth tuning for the flexible sample position of an endoscopic OCT image are discussed. After post-tuning of sample position distance, the positioning limitation between the reference reflector and the sample can be solved for various sample positions over a range of 26 mm for the cross-sectional images of a fish eye sample.

A study to reduce measurement errors of an ultrasonic rangefinder (초음파 거리 센서의 계측오차 감소를 위한 연구)

  • 도용태;김태호;유석환
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.43-52
    • /
    • 1997
  • Ultrasonic sensors are widely employed in detecting range to a target by the virtue of their low cost and simplicity. However, the sensor's measurements are corrupted by systematic errors due mainly to the dependency of sound speed upon surrounding conditions and random errors of uncertain origin. In this paper, we present the results of research carried out to reduce these errors for increasing the reliability of an untrasonic sensor system to be used in orbotic or other automated system's range finding. The sensor system designed herein is in a peuliar structure having a reference target and two receivers. Echoes from a small reference target placed at a known distance are used for compensating the variations of sound speed according to the changes of sensing conditions. Unlike existing ones, the technique proposed can compensate the effects of temperature or any other physical parameters without an additional sensor dedicated to the compensation. The measurements by two redundantly employed receivers are fused to reduce random errors in a statistical sense. The correlation of the signals from the receivers sharing a hardware in part is considered in the fusion process. The methodology desicribed in this paepr is conceptually simple, easy to be implemented, and effetive to increase the accuracy of the sensor measurements as experimental results confirm.

  • PDF

An Automatic Threshold Control Circuit Adaptive to Burst Optical signal Levels (버스트 광 신호 레벨 적응형 기준레벨 자동 발생회로)

  • 기현철
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.12
    • /
    • pp.24-30
    • /
    • 2003
  • In this paper, we proposed an adaptive ATC(Automatic Threshold Control) circuit with more decreased settling time by improving the structure of the peak detector. We showed that it could reduce a good deal of the settling time because it showed less than half the error voltage ratio that the ATC circuit with conventional structure showed in analysis. We also designed a burst-mode ATC circuit for the 1.25Gbps EPON system using a commercial foundry. It produced the reference levels in very short time, 6㎱ in 40 ㏈ input dynamic range.

A Case of Hunter Syndrome Presented with Chronic Purulent Rhinorrhea in 24-month-old Boy (24개월에 만성 화농성 비루를 주소로 내원하여 진단된 헌터 증후군 1례)

  • Kim, I An;Jin, Jang Yong;Park, Jae Ock;Hong, Yong Hee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.160-164
    • /
    • 2015
  • Hunter syndrome(Mucopolysaccharidosis type II, MPS type II) is an X-linked disorder of glycosaminoglycans (GAGs) metabolism caused by an iduronate-2-sulfatase (IDS2) deficiency. A 24-month-old boy visited the department of pediatrics with the chief compliant of chronic purulent rhinorrhea beginning at age one. He had a history of repeated acute otitis media and chronic rhinitis. On physical examination he had a coarse face, enlarged tongue, distended abdomen, joint stiffness, and Mongolian spots at his first visit. The urine GAGs level was elevated at 66.10 mg/mmolCr (reference range, <11.1) and iduronate-2-sulfatase activity in leukocyte was decreased at 0.21 nmol/mg protein/hr (reference range, 18.7-57). Finally with an IDS gene mutational analysis, recombinant known mutation between intron 7 and distal of exon 3 in IDS2 was detected. Recombinant iduronate-2-sulfatase therapy was started without any infusion related reactions. The author highlights the importance of suspecting Hunter syndrome when pediatric patients visit with chronic purulent rhinorrhea which is a common cause of hospital visits for infants and children.

A Modified Methylation Method to Determine Fatty Acid Content by Gas Chromatography

  • Wirasnita, Riry;Hadibarata, Tony;Novelina, Yus Maria;Yusoff, Abdull Rahim Mohd;Yusop, Zulkifli
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.11
    • /
    • pp.3239-3242
    • /
    • 2013
  • An improved rapid method for determination of the fatty acid composition using modified methylation procedure was compared with the AOAC reference procedure based on the methylation of fatty acid with the addition of BF3 catalyst before and while heating. The new method is useful for research and routine quality control and has a number of advantages over the reference procedure which are more rapid, simple and also reliable. Applicability of the modified methylation method was confirmed with three vegetable oil samples (palm oil, coconut oil and olive oil). Based on the validation method results, we obtained that a quite linear calibration curve of fatty acids was performed with $R^2$ in range of 0.9972-0.9994. The sensitivity of gas chromatography instrument was able to analyze the fatty acids up to a few ppm, the precision and accuracy were good enough with the %RSD between 1.5%-19.5% and the recovery of linolenic acid was 99.1% in the range of 80.0%-113.3%.

Stimulated Brillouin scattering using a source with a few axial modes and an optical fiber ring resonator (수개의 종모드를 갖는 광원에 의한 고리형광섬유공진기에서의 유도브릴루앙산란)

  • 이현재;윤병호;이동호;전영윤;김향균
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.324-330
    • /
    • 1995
  • Stimulated Brillouin scattering theory is described in an optical fiber. Frequency change with an optical heterodyne method is analyzed between reference signal of a source and stimulated Brillouin scattering signal in an optical fiber. By coupling a source with a few axial modes and an optical fiber ring resonator, Brillouin scattering is studied with a spectrum analyzer. Using reference beating signal of a source, we have reduced the Brillouin beating frequency from 13 GHz range to below GHz. Experimentally, we can see the Brillouin beating frequency from 13 GHz range to below GHz with a dispersion shifted fiber (1.32 GHz), Ti-doped fiber (900 MHz) and single mode optical fiber (870 MHz). MHz).

  • PDF

Acute pancreatitis in hand, foot and mouth disease caused by Coxsackievirus A16: case report

  • Park, Byungsung;Kwon, Hyuckjin;Lee, Kwanseop;Kang, Minjae
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.10
    • /
    • pp.333-336
    • /
    • 2017
  • Coxsackievirus A16 (CA16), which primarily causes hand, foot, and mouth disease (HFMD), is associated with complications, such as encephalitis, acute flaccid paralysis, myocarditis, pericarditis, and shock. However, no case of pancreatitis associated with CA16 has been reported in children. We report a case of CA16-associated acute pancreatitis in a 3-year-old girl with HFMD. She was admitted because of poor oral intake and high fever for 1 day. Maculopapular rashes on both hands and feet and multiple vesicles on the soft palate were observed on physical examination. She was treated conservatively with intravenous fluids. On the fourth hospital day, she had severe abdominal pain and vomiting. The serum levels of amylase and lipase were remarkably elevated (amylase, 1,902 IU/L; reference range, 28-100 IU/L; lipase, >1,500 IU/L; reference range, 13-60 IU/L), and ultrasonography showed diffuse swelling of the pancreas with a small amount of ascites. The real-time reverse transcription polymerase chain reaction result from a stool sample was positive for CA16. CA16 can cause acute pancreatitis, and should be considered in the differential diagnosis of abdominal pain in children with HFMD.

Digital Image Quality Assessment Based on Standard Normal Deviation

  • Park, Hyung-Ju;Har, Dong-Hwan
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.20-30
    • /
    • 2015
  • We propose a new method that specifies objective image quality factors by evaluating an image quality measurement model using random images. In other words, No-Reference variables are used to evaluate the quality of an original image without using any reference for comparison. 1000 portrait images were collected from a web gallery with votes constituting over 30 recommendation values. The bottom-up data collecting process was used to calculate the following image quality factors: total range, average, standard deviation, normalized distribution, z-score, preference percentage. A final grade is awarded out of 100 points, and this method ranks and grades the final estimated image quality preference in terms of total image quality factors. The results of the proposed image quality evaluation model consist of the specific dynamic range, skin tone R, G, B, L, A, B, and RSC contrast. We can present the total for the expected preference points as the average of the objective image qualities. Our proposed image quality evaluation model can measure the preferences for an actual image using a statistical analysis. The results indicate that this is a practical image quality measurement model that can extract a subject's preferred image quality.

Development of Optimum Rutin Extraction Process from Fagopyrum tataricum (쓴 메밀에서의 루틴 추출 최적 공정 개발)

  • Yoon, Seong-Jun;Cho, Nam-Ji;Na, Seog-Hwan;Kim, Young-Ho;Kim, Young-Mo
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.16 no.5
    • /
    • pp.573-577
    • /
    • 2006
  • The rutin content of Fagopyrum tataricum is 100-fold higher than that of Fagopyrum esculentum. For the development of a rutin-containing beverage, a suitable method to extract rutin from buckwheat (Fagopyrum tataricum) with high rutin yield was investigated. A roasting temperature range of $310/240^{\circ}C$ (Ed-confirm that this is indeed a range; otherwise perhaps, 'Roasting temperatures ranging from 310 to $240^{\circ}C$ were considered$\ldots$') was considered to be the best as the basic color reference. Rutin content varied according to the roasting time and heating temperature; i.e., it decreased with increasing roasting time and temperature. (Ed- this sentence is unnecessarily complicated and should be simplified to 'Rutin content decreased with increasing roasting time and heating temperature.') The optimal extraction temperature and processing time were obtained as $80^{\circ}C$ and 10 minutes to maximize the rutin concentration in the extract.

  • PDF