• Title/Summary/Keyword: reference energy

Search Result 1,629, Processing Time 0.024 seconds

Trends of Annual and Monthly FAO Penman-Monteith Reference Evapotranspiration (연별 및 월별 FAO Penman-Monteith 기준증발산 추세 분석)

  • Rim, Chang-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.65-77
    • /
    • 2008
  • The effects of climatic changes owing to urbanization, geographical and topographical conditions on annual and monthly FAO Penman-Monteith (FAO P-M) reference evapotranspiration, and energy and aerodynamic terms of FAO P-M reference evapotranspiration were studied. In this study, 21 climatological stations were selected. The statistical methods applied for trend analysis are Spearman rank test, Sen's test, linear regression analysis and analysis of actual variation ratio. Furthermore, the cluster analysis was applied to cluster 21 study stations by considering the geographical and topographical characteristics of study area. The study results indicate that urbanization affects the trend and amount of FAO P-M reference evapotranspiration, energy term and aerodynamic term; however, the result of Sen's test indicates that urbanization does not significantly affect the magnitude of trend (Sen's slope). The energy term increased at study stations located in coastal area; however, decreased at study stations located in inland area. The topographical slope of study area did not significantly influence on the trend of energy term. The aerodynamic term increased in both coastal area and inland area, indicating much significantly increasing trend in inland area, and it was also affected by the topographical slope of the study area.

Comparative Analysis of Elemental Components in Airborne Particulate Matter by k0-NAA Methods (대기분진의 원소분석에 대한 k0-NAA법의 비교)

  • Chung, Yong-Sam;Moon, Jong-Hwa;Cho, Hyun-Je;Kim, Young-Jin
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.51-58
    • /
    • 2005
  • A comparison of the analytical data obtained by three $k_0$-NAA software programs was carried out using both the airborne particulate matter collected from an urban site and the certified reference materials of the air filter and urban dust to evaluate the performance of the analysis. The individual $k_0$-NAA standardization methods of three countries, Korea, China and Vietnam which had been modified from the well established $k_0$-program were used for the comparative analysis. The measured concentrations of 30 elements from the two kinds of air samples based on this software were in agreement with each other within about 20% analytical error except for a few elements. By contrast, the results of China and Vietnam were moderately higher than that of Korea due to a systematic error associated with the detection efficiency, gamma peak analysis and geometric effect.

Scoping Calculations on Criticality and Shielding of the Improved KAERI Reference Disposal System for SNFs (KRS+)

  • Kim, In-Young;Cho, Dong-Keun;Lee, Jongyoul;Choi, Heui-Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.spc
    • /
    • pp.37-50
    • /
    • 2020
  • In this paper, an overview of the scoping calculation results is provided with respect to criticality and radiation shielding of two KBS-3V type PWR SNF disposal systems and one NWMO-type CANDU SNF disposal system of the improved KAERI reference disposal system for SNFs (KRS+). The results confirmed that the calculated effective multiplication factors (keff) of each disposal system comply with the design criteria (< 0.95). Based on a sensitivity study, the bounding conditions for criticality assumed a flooded container, actinide-only fuel composition, and a decay time of tens of thousands of years. The necessity of mixed loading for some PWR SNFs with high enrichment and low discharge burnup was identified from the evaluated preliminary possible loading area. Furthermore, the absorbed dose rate in the bentonite region was confirmed to be considerably lower than the design criterion (< 1 Gy·hr-1). Entire PWR SNFs with various enrichment and discharge burnup can be deposited in the KRS+ system without any shielding issues. The container thickness applied to the current KRS+ design was clarified as sufficient considering the minimum thickness of the container to satisfy the shielding criterion. In conclusion, the current KRS+ design is suitable in terms of nuclear criticality and radiation shielding.

Electrical Characteristic Changes of ZnO Varistors by Energy Absorption

  • Kim, Woo-Hyun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.12
    • /
    • pp.817-821
    • /
    • 2017
  • As a ZnO varistor is subjected to electrical and environmental stresses, it degrades gradually, which may result in power interruption by short circuit. This study investigates changes in the electrical characteristics of ZnO varistors due to deterioration owing to energy absorption, and determines the optimal parameters for on-line diagnosis of the varistor. Two types of varistors were used for an accelerated aging experiment involving the application of the $8/20{\mu}s$ standard lightning impulse current. The electrical characteristics in terms of the reference voltage, total leakage current, resistive leakage current, and third-harmonic component of the total leakage current were measured, and their change rates were analyzed. The results revealed that the total leakage current increased slightly with an increase in the varistor absorbed energy, while the resistive leakage current and the third-harmonic component increased apparently. Therefore, the third-harmonic component of the total leakage current was proposed as the optimal parameter for on-line monitoring of ZnO varistor conditions.

Development of an information reference system using reconstruction models of nuclear power plants

  • Harazono, Yuki;Kimura, Taro;Ishii, Hirotake;Shimoda, Hiroshi;Kouda, Yuya
    • Nuclear Engineering and Technology
    • /
    • v.50 no.4
    • /
    • pp.606-612
    • /
    • 2018
  • Many nuclear power plants in Japan are approaching the end of their planned operational life spans. They must be decommissioned safely in the near future. Using augmented reality (AR), workers can intuitively understand information related to decommissioning work. Three-dimensional (work-site) reconstruction models of dismantling fields are useful for workers to observe the conditions of dismantling field situations without visiting the actual fields. This study, based on AR and work-site reconstruction models, developed and evaluated an information reference system. The evaluation consists of questionnaires and interview surveys administered to six nuclear power plant workers who used this system, along with a scenario. Results highlight the possibility of reducing time and mitigating mistakes in dismantling fields. Results also show the ease of referring to information in dismantling fields. Nevertheless, it is apparently difficult for workers to build reconstruction models of dismantling fields independently.

Current Conservation Factors for Consistent One-Dimensional Neutronics Modeling

  • Lee, Kibog;Joo, Han-Gyu;Cho, Byung-Oh;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.235-243
    • /
    • 2000
  • A one-dimensional neutronics formulation is established within the framework of the nonlinear analytic nodal method such that it can result in consistent one-dimensional models that produce the same axial information as their corresponding reference three-dimension81 models. Consistency is achieved by conserving axial interface currents as well as the planar reaction rates of the three-dimensional case. For current conservation, flux discontinuity is introduced in the solution of the two-node problem. The degree of discontinuity, named the current conservation factor, is determined such that the surface averaged axial current of the reference three-dimensional case can be retrieved from the two-node calculation involving the radially collapsed group constants and the discontinuity factor. The current conservation factors are derived from the analytic nodal method and various core configurations are analyzed to show that the errors in K-eff and power distributions can be reduced by a order of magnitude by the use of the current conservation factor with no significant computational overhead.

  • PDF

Experimental evaluation of splicing of longitudinal bars with forging welding in flexural reinforced concrete beams

  • Sharbatdar, Mohammad K.;Jafari, Omid Mohammadi;Karimi, Mohammad S.
    • Advances in concrete construction
    • /
    • v.6 no.5
    • /
    • pp.509-525
    • /
    • 2018
  • In this paper the application of forging process as benefit technique in Reinforced Concrete (RC) beam bars and comparison to lap splices was experimentally investigated with four concrete beam specimens with same dimensions and reinforcement details. The reference specimen was with no splices and the other three beams were with different splices (100% forging in the middle, 50% forging, and 100% lap splices in the middle). Beams were tested with the four points load system. Experimental test results indicated that using forging process as new bar splicing method can have high effects on increasing ductility and energy dissipation of concrete structures. It also proved that this method increased the flexural rigidity, energy absorption, and ductility of the RC beams. And also this research results showed that the flexural capacity and ductility of the beam with 50% forging were respectively increased up to 10% and 75% comparing to that of reference specimen, but the energy absorption of this beams was decreased up to 27%. The ductility of beam with 50% forging was increased up to 25% comparing the ductility of beam with 100% forging.

The study of the solar radiation emitted per hour in Incheon applied in load calculation programs (부하계산 프로그램에서 적용되는 인천지역의 시간당 일사량에 관한 연구)

  • Yoo, Ho-Chun;Lee, Seon-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.108-117
    • /
    • 2010
  • Although many researches of simulation programs to predict climate under the current climate change have been performed but more detailed studies of weather date which might influence the load of buildings seem insufficient. In this study, in Incheon are analyzed IES (Integrated Environmental Solutions)6.0, Ecotect 2010, EnergyPlus v4.0's IWEC file and ISO-TRY, the Korean standard weather data provided by the Korean Solar Energy Society for direct normal radiation which is used in load calculation programs. The results show that the radiation of the programs is the same as that of direct normal radiation per month but has a mere difference, compared with the radiation per hour and IWEC has also 77.12% when compared with ISO-TRY, meaning that it could affect load values of buildings when applied to them. And in case of ISO-TRY, it could be judged that the application of test reference year applied by the data measured has higher reliability than IWEC file.

Comparison and analysis of typical metrological data by in korea (대한민국의 지역별 표준기상데이터 비교분석)

  • Yoo, Ho-Chun;Noh, Kyoung-Hwan;Kang, Hyun-Gu;Shin, In-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.361-366
    • /
    • 2009
  • Amid the crisis of global climate change, interest in low carbon and energy-saving building has been increasingly growing. Korea is likely to be designated as one of the countries subject to CO2 reduction under the 'Post-2012 Climate System' The efforts to minimize the building energy has been made and in line with the increasing need of low carbon and eco-friendly building, a demand for building evaluation programs has been on the rise. However, the metro logical data which is necessary for such program has not been effectively provided and moreover, the source, calculation method and period remain uncertain. This study was intended to evaluate the regional typical metro logical data (ISO TRY) provided by Korean Solar Energy Society and compile the month of test reference years (TRY), and analyze the regional weather using dry-bulb temperature, wet-bulb temperature and solar irradiance which are regarded the representative metro logical data.

  • PDF

Innovative Decision Reference Based Algorithm for Photovoltaic Maximum Power Point Tracking

  • Mehrnami, Siamak;Farhangi, Shahrokh
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.528-537
    • /
    • 2010
  • A novel decision reference based method for the maximum power point tracking (MPPT) of PV arrays is presented in this paper. The proposed decision reference was derived from a simplified solar cell model. This method solves the problems of conventional MPPT algorithms, such as oscillation of the operating point at the steady state and confusion under rapidly changing insolation. It is shown by simulation and experimental results that the method properly tracks a rapidly changing insolation profile. The signal to noise ratio (SNR) of the new decision reference is also higher than those of conventional P&O and INC methods. An updating subroutine was included in the proposed MPPT algorithm to compensate for temperature and aging effects.