• Title/Summary/Keyword: reference coordinates

Search Result 241, Processing Time 0.021 seconds

Objective evaluation of the color of tongue substance using L*a*b* color coordinates

  • Park, Young-Jae;Park, Young-Bae
    • Advances in Traditional Medicine
    • /
    • v.6 no.2
    • /
    • pp.112-120
    • /
    • 2006
  • The purpose of this study was to analyze whether quantitative evaluation of the color of the tongue substance using $L^*a^*b^*$ color coordinates system could minimize the problems arising from the different illuminating conditions or not. In controlled 4 different illuminating conditions (by natural light, flashlight, f-number, shutter speed),12 healthy subjects were photographed of their tongue substance through a digital camera (C-2100uz, Olympus Co.), both on the top surface and on the bottom surface of the tongue substance by two examiners, twice at 3 day intervals. Clinician evaluation was also performed grading the redness of the tongue substance in the form of 5-points scale by 6 clinicians. As a result, there was no significant difference in color differences between the color of the tongue substance and the reference red card in the 4 different illuminating conditions. Intra-rater reliability was satisfied and even though limitedly, inter-rater reliability was satisfied. Color differences were significantly correlated with the results by the clinicians, although they were applicable limitedly to specific illuminating conditions. Our results indicate that the application of the color differences in tongue diagnosis could not only evaluate the color information quantitatively, but also minimize the problems arising from the different illuminating conditions and that there was the significant difference in the visual evaluation of the red color of the tongue substance, both between the clinicians and between the illuminating conditions.

An Camera Information Detection Method for Dynamic Scene (Dynamic scene에 대한 카메라 정보 추출 기법)

  • Ko, Jung-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.275-280
    • /
    • 2013
  • In this paper, a new stereo object extraction algorithm using a block-based MSE (mean square error) algorithm and the configuration parameters of a stereo camera is proposed. That is, by applying the SSD algorithm between the initial reference image and the next stereo input image, location coordinates of a target object in the right and left images are acquired and then with these values, the pan/tilt system is controlled. And using the moving angle of this pan/tilt system and the configulation parameters of the stereo camera system, the mask window size of a target object is adaptively determined. The newly segmented target image is used as a reference image in the next stage and it is automatically updated in the course of target tracking basing on the same procedure. Meanwhile, a target object is under tracking through continuously controlling the convergence and FOV by using the sequentiall extracted location coordinates of a moving target.

Implementation on the Urine Analysis System using Color Correction and Chromaticity Coordinates Transform Methods (색 보정 및 색 좌표 변환 기법을 이용한 요분석 시스템의 구현)

  • 김기련;예수영;손정만;김철한;정도운;이승진;장용훈;전계록
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.183-192
    • /
    • 2003
  • A transformation methode of the chromaticity coordinates was proposed to calibrate the measured data obtained by a urine analysis system which implemented in our previous study. Generally. the reacted color of a reagent strip by urine analysis system often exhibit the color distortions due to nonlinear characteristics of the various devices that is the optic module mechanism. hardware, and surround circumstance. A color correction method for minimizing the color distortion play a few role in maintaining high accuracy and reproduction of the urine analysis system. In this work, we used the compensation method such as the shading correction, the characteristic curve extraction of RGB color by means of third order spline interpolation, and linear transformation using a reference color. In addition, 1931 CIE XYZ color space was used to compensate the color of the measured data by a standard reference system as colorimeter. A compensation matrix was obtained so that the output values of the urine analysis system is nearly equal to that of a standard reference system for identical color sample. Color correction obtained by a urine analysis system which implemented in our previous study exhibited a good color accuracy when it was compared with the reference data. Observed result from an experiments on ten items or a urinalysis strip that color difference or between two urine analysis system was 1.28.

The Coordinates Computation of the GPS Base Station by Precise Point Positioning (정밀절대측위(PPP)기법에 의한 GPS 기준점 좌표의 산정)

  • 이용창
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.2
    • /
    • pp.145-152
    • /
    • 1999
  • JPL(Jet Propulsion Laboratory) has been routinely produced the precise GPS ephemeris and clock's correction parameter using data collected from globally distributed permanent GPS tracking stations, and has been offering the automated GPS data analysis(Precise Point Positioning: PPP) service by using them. In this study, after investigating the potential capacity of JPL's PPP service, the coordinates computation of the GPS base station by this service were investigated. For this, the dual frequency P codes data of 24 hours were observed from continuously operating four reference stations in USA. sent to the JPL's main computer through E-mail and/or ftp, and then were processed by Gipsy/Oasis-II (GOA-II) software with the precise GPS transmitter parameters. Centimeter-level positioning results were available to obtain in X, Y, Z geocentric rectangular coordinate system.

  • PDF

Proposal and Validation of a New Flame Stability Diagram to Gas Estimate Interchangeability (가스호환성 판정에 편리한 새로운 화염안정영역의 도시법의 제안 및 유용성 검토)

  • Lee, Chang-Eon;Kim, Jong-Min;Hwang, Cheol-Hong;Kim, Jong-Hyun
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.3
    • /
    • pp.1-8
    • /
    • 2008
  • A flame stability diagram in a partially premixed flame is typically expressed using the axis coordinates of heat input rate and equivalence ratio. These diagrams are inadequate for identifying changes in combustion conditions and flame stability when a reference fuel is substituted with other fuels under identical operating conditions. This study proposes a new type of diagram and validates it experimentally. In this new diagram, the axis coordinates are air flow rate and Wobbe fuel flow rate, defined as the fuel flow rate multiplied by the square root of the relative density. The diagram was validated in trials using various fuels, including $CH_4$, $C_{3}H_{8}$, and LFG-$C_{3}H_{8}$ mixed fuels, in a domestic gas-range and an gas interchangeability test burner. The results of these trials show that the new diagram can provide information useful for assessing gas interchangeability of combustion conditions and flame stability when one fuel is substituted with another under identical operating conditions.

  • PDF

Color Compensation Method for Non-Contact Color Inspection on Plasma Display Panel (플라즈마 디스플레이 패널에서 비접촉식 칼라 검사를 위한 칼라 보정 방법)

  • 도현철;김우섭;진성일;태흥식
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.5
    • /
    • pp.71-75
    • /
    • 2004
  • An efficient color compensation method is proposed to reduce the color difference between the camera based inspection system and the colorimeter based inspection system in a plasma display panel production line. The color compensation matrix can be constructed by using the relationship between RGB to XYZ conversion matrices, which are obtained by the RGB primaries and reference white chromaticity coordinates. Experimental results show that the non-contact color inspection system using the proposed color compensation method satisfactorily compensates the chromaticity coordinates acquired by the area color CCD camera to be matched to those measured by the colorimeter for various test color.

Quantitative Evaluation of Setup Error for Whole Body Stereotactic Radiosurgery by Image Registration Technique

  • Kim, Young-Seok;Yi, Byong-Yong;Kim, Jong-Hoon;Ahn, Seung-Do;Lee, Sang-wook;Im, Ki-Chun;Park, Eun-Kyung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.103-105
    • /
    • 2002
  • Whole body stereotactic radiosurgery (WBSRS) technique is believed to be useful for the metastatic lesions as well as relatively small primary tumors in the trunk. Unlike stereotactic radiosurgery to intracranial lesion, inherent limitation on immobilization of whole body makes it difficult to achieve the reliable setup reproducibility. For this reason, it is essential to develop an objective and quantitative method of evaluating setup error for WBSRS. An evaluation technique using image registration has been developed for this purpose. Point pair image registrations with WBSRS frame coordinates were performed between two sets of CT images acquired before each treatment. Positional displacements could be determined by means of volumetric planning target volume (PTV) comparison between the reference and the registered image sets. Twenty eight sets of CT images from 19 WBSRS patients treated in Asan Medical Center have been analyzed by this method for determination of setup random error of each treatment. It is objective and clinically useful to analyze setup error quantitatively by image registration technique with WBSRS frame coordinates.

  • PDF

Analysis of Dynamic Response of a Floating Crane and a Cargo with Elastic Booms Based on Flexible Multibody System Dynamics (붐의 탄성효과를 고려한 해상크레인의 유연 다물체 동역학 해석)

  • Park, Kwang-Phil;Cha, Ju-Hwan;Lee, Kyu-Yeul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.47 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • This study analyzes the dynamic response of a floating crane with a cargo considering an elastic boom to evaluate(or for evaluation of) its flexibility effect on their dynamic response. Flexible multibody system dynamics is applied in order to establish a dynamic equation of motion of the multibody system, which consists of flexible and rigid bodies. In addition, a floating reference frame and nodal coordinates are used to model the boom as a flexible body. The study also simulates the coupled surge, pitch, and heave motions of the floating crane carrying the cargo with three degrees of freedom by numerically solving the equation. Finally, the simulation results of the elastic and rigid booms are comparatively analyzed and the effects of the flexible boom are discussed.

Geomagnetism measured in DZN (Daejeon) Geomagnetic Observatory and its time-variation (대전지자기관측소에서 측정된 지자기 값과 시간에 따른 변화)

  • Lim, Mu-Taek;Park, Yeong-Sue;Rim, Hyeong-Rae;Koo, Sung-Bon;Lee, Young-Cheol;Na, Jae-Shin
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.353-360
    • /
    • 2007
  • KIGAM has installed a FLARE+ continuous geomagnetic observation system in 1998 in Daejeon of which the IAGA identification code is DZN. The coordinates of the absolute measurement plinth precisely determined by the PDGPS(Post-Processing Differential Global Positioning System) is (127-21-37.19E, 36-22-43.96N, 45.93 m) in WGS84 for the horizontal and from the geoid surface for the vertical. Periodically we have conducted the absolute geomagnetic measurement on the plinth above. We have processed the continuous time-variation 3-axis geomagnetic data measured on arbitrary sensors' coordinates in the observatory and absolute geomagnetic data together to get as the results the time-variation H(orizontal), D(eclination), Z(vertical down), F(scalar calculated from 3 components) and P(Proton Precession Magnetometer Data). We have compared our own data with those calculated from the 10th generation IGRF(International Geomagnetic Reference Field). All the measured data in the DZN Observatory can be acquired through the website http://geomag.kigam.re.kr.

  • PDF

Standard Terminology System Referenced by 3D Human Body Model

  • Choi, Byung-Kwan;Lim, Ji-Hye
    • Journal of information and communication convergence engineering
    • /
    • v.17 no.2
    • /
    • pp.91-96
    • /
    • 2019
  • In this study, a system to increase the expressiveness of existing standard terminology using three-dimensional (3D) data is designed. We analyze the existing medical terminology system by searching the reference literature and perform an expert group focus survey. A human body image is generated using a 3D modeling tool. Then, the anatomical position of the human body is mapped to the 3D coordinates' identification (ID) and metadata. We define the term to represent the 3D human body position in a total of 12 categories, including semantic terminology entity and semantic disorder. The Blender and 3ds Max programs are used to create the 3D model from medical imaging data. The generated 3D human body model is expressed by the ID of the coordinate type (x, y, and z axes) based on the anatomical position and mapped to the semantic entity including the meaning. We propose a system of standard terminology enabling integration and utilization of the 3D human body model, coordinates (ID), and metadata. In the future, through cooperation with the Electronic Health Record system, we will contribute to clinical research to generate higher-quality big data.