• Title/Summary/Keyword: reasonableness

Search Result 97, Processing Time 0.033 seconds

Multi-level PWM Inverter Considering the number of Output Voltage level and Current rating (출력전압 레벨 수와 전류정격을 고려한 PWM 다중레벨 인버터)

  • Park, N.S.;Seo, J.J.;Park, S.J.;Kim, K.H.;Cho, S.E.;Kim, C.U.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.659-662
    • /
    • 2005
  • In this paper, we proposed the novel hybrid multi-level inverter using combination of the output voltage of transformers to reduce the THD(Total Harmonic Distortion) and improve the waveform of output voltage. The proposed multi-level inverter used the output of transformer which is 1times, 2times, 4times of input of the transformers. So we increased the output voltage from the reduce the number of switching component and transformer. Also, we tested the proposed prototype 15-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi -level PWM inverter.

  • PDF

Low frequency Multi-level Switching Strategy based on Phase-Shift Control (위상 변위제어기법을 이용한 저주파 다중레벨 스위칭 방식)

  • Yu, Tao;Moon, C.J.;Park, S.J.;Nam, H.K.;Kwon, S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.673-676
    • /
    • 2005
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level inverter combined with H-Bridge Inverters and Transformers. and furthermore we suggested the new multi-level PWM inverter using PWM level to reduce THD(Total Harmonic Distortion). and we used the switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi-level PWM inverter.

  • PDF

Inverse Calibration of a Robot Manipulator Using Neural Network (뉴럴 네트워크를 이용한 로봇 매니퓰레이터의 역보정)

  • 정동연;김종수;한성현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.199-204
    • /
    • 1999
  • The robot inverse calibration method using a neural networks is proposed in this paper. A high-order networks has been used in this study. The Pi-Sigma networks uses linear summing units in the hidden layer and product unit in output layer. The inverse calibration model which compensates the difference of joint variables only between measuring value and analytic value about the desired pose(position orientation) of a robot is proposed. The compensated values are determined by using the weights obtained from the learning process of the neural networks previously. To prove the reasonableness, the selected compliance automatic robot arm type direct drive robot and anthropomorphic robot are simulated. It shows that the proposed calibration method can reduce the errors of the joint variables from ${\pm}$0.15$^{\circ}$to ${\pm}$0.12$^{\circ}$.

  • PDF

Development of the daily runoff simulation model (일유출량 모의 모형의 개발)

  • Kim, Yang-Su;Seo, Byung-Ha;Kang, Kwan-Weon
    • Water for future
    • /
    • v.22 no.3
    • /
    • pp.307-313
    • /
    • 1989
  • This study is aimed to develop a long-term daily runoff simulation model. The model is theoretically constructed and is applied to the practical problems to verify its reasonableness. A lumped, nonlinear model is proposed and is calibrated as quasilinearization procedures. The hydrological data used in the paper are precipitation, runoff, and evaporation records in the Bochong Stream which is one of the tributaries of the Geum River.

  • PDF

A Value-Based Real Time Pricing Under Imperfect Information on Consumer Behavior

  • Kim, Bal-Ho H.
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.49-54
    • /
    • 2009
  • One of the major challenges confronting a multiservice electric utility is the establishment of the right prices for its services. The key objectives of particular pricing schemes are reasonableness of company earnings, economic efficiency, the responsiveness of supply and of the allocation of sources to the desires of consumers, and maintenance of some degree of competition. This paper proposes a value-based pricing mechanism amenable to the current deregulation situation in electricity market allowing service differentiation. The proposed pricing mechanism can be implemented in a nodal auction model, and can also be applied to direct load control.

Reducing Switching Device of the HBML Inverter using the Transformers (변압기를 이용한 HBML 인버터의 스위칭소자 저감)

  • Lee H.C;Lee S.H.;Song S.G.;Cho S.E.;Park S.J.;Lee M.H
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.95-101
    • /
    • 2005
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level PWM inverter combined with H-Bridge Inverters and Transformers. and we proposed the switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

Novel Multi-Level PWM Inverter Using The Common Arm (공통암을 이용한 새로운 다중레벨 PWM 인버터)

  • .Song S.G;Yu tao;Lee S.H.;Cho S.E.;Moon C.J.;Kim C.U;Park S.J.
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.4
    • /
    • pp.195-200
    • /
    • 2005
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level inverter combined with H-Bridge Inverters and Transformers. and furthermore we suggested the new multi-level PWM inverter using PWM level to reduce THD(Total Harmonic Distortion). and we used the switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi-level PWM inverter.

3-phase IHCML inverter using common-arm (공통암 3상 IHMCL 인버터)

  • Song, S.G.;Park, S.J.;Moon, C.J.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.512-514
    • /
    • 2007
  • The number of transformers and the size of transformers in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm. Also, the equal-area method is used to calculate conduction angle with switching frequency equal to output fundamental frequency and it can reduce harmonics component of output voltage and switching loss. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

  • PDF

Multi-level Inverter Using 3-Phase isolated Transformers (3상 절연형 변압기를 이용한 다중레벨)

  • Lee, Hwa-Chun;Song, Sung-Gun;Park, Sung-Jun;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1134-1135
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

  • PDF

Cascade 3-Phase IHCML Inverter using maximal distension vector control (최근접 벡터 제어기법을 이용한 Cascade 3상 IHCML 인버터)

  • Song, Sung-Geun;Park, Sung-Jun;Nam, Hae-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.187-189
    • /
    • 2007
  • In this paper, the cascade 3-phase IHMCL inverter using two low frequency transformers is proposed. The proposed inverter is constructed by connecting a 3-phase IHCML inverter. the cascade 3-phase IHCML inverter has several advantages. One advantage is that only one input power source is required because of using transformers to isolate. Another advantage is that the switching frequency of the high power switches is almost fundamental frequency of reference and the other the switching frequency of the low power switches is higher. It can be known that cascade 3 phase IHCML inverter has the excellent efficiency and the outstanding electric quality. lastly, we tested the 5kW cascade 3-phase IHCML inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed inverter.

  • PDF