• Title/Summary/Keyword: reasonable deviation

Search Result 133, Processing Time 0.022 seconds

Evaluation of Quality Levels with Multiple Probability Distributions Under the Taguchi's Feedback Control System (다구찌의 피드백 제어시스템 내 다수 함수 품질특성 고찰)

  • Song, Do-Hyun;Lee, Sang-Heon
    • Korean Management Science Review
    • /
    • v.24 no.1
    • /
    • pp.77-90
    • /
    • 2007
  • Taguchi assumed that a product characteristic has the uniform distribution in its preventive maintenance limit when deriving the expected loss generated by the quality deviation. But it is reasonable to assume that a product characteristic has the normal distribution than the uniform distribution. On this paper, we first find the optimum inspection interval and the optimum preventive maintenance limit under the truncated triangular distribution. Secondly we use the beta-general distribution and compare with the truncated triangular distribution. By using the numerical examples, we find the optimum inspection interval and the optimum preventive maintenance limit under their distributions. As a result, we find that the beta-general distribution gives the best solution and easy calculation.

Static Test and Analysis of Wing Support Structure for External Stores (외부장착물지지 주익구조 정적 시험 및 해석)

  • Uhm, Wonseop;Yoon, Jongmin
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • Armed aircraft of a basic trainer class installs external stores under wing box by using pylon and performs an operation such as weapon delivery and jettison, and should be designed to withstand all kinds of loads applied to external stores. The static strength test of pylons and wing box was performed to assess the static strength of pylon and their support structures for substantiation. Based on the test, the structures were verified to fully satisfy a given design requirement. In this paper, methods of test load generation of wing box and pylon, evaluation of test result data and design result of test set-up were presented. Comparing the FEM analysis with the same test data can lead to good match and reasonable deviation between both. Finally, based on the test and the analysis, the static strength of test article was substantiated and the reliability and effectiveness of analysis math model were obtained.

A Temperature Analysis Study of Korea and its Neighbor Regions for Temperature Specification (온도규격 설정을 위한 한반도 및 주변권역 온도분석 연구)

  • Kim, In-Soo;Kang, Chee-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.55-65
    • /
    • 2015
  • This paper describes the results of a temperature analysis of Korea and its neighbor regions for temperature specification of weapon systems to be deployed in Korea, and introduces the concept of a standard deviation frequency of occurrence which represents a frequency of yearly occurrence. On the basis of this analysis, reasonable operational temperatures for the Korea weapon systems are recommended, and the regional frequency of yearly occurrence of temperatures worse than recommended operational temperatures in each country regions are presented.

An Investigation into the Application of the Modal Analysis to the Calculation o Transverse Vibration Responses of Ship Hulls (선체횡진동응답(船體橫振動應答)의 Model Analysis에 관한 고찰(考察))

  • S.B.,Han;K.C.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.2
    • /
    • pp.29-34
    • /
    • 1984
  • The degree of deviation from the orthogonality relations of the actual ship's natural modes and its effects on the vibration responses are numerically investigated. The results show that, for the practical application of the modal analysis, it is not an essential requirement in utilization of the expansion theorem to assume the added mass being constant regardless of the mode shapes, or to take the dry hull's natural modes. That is, it is more reasonable to take the actual ships natural modes as the set of the normal modes and to get the solution of the normal coordinates equation by neglecting both the inertia coupling and the stiffeness coupling.

  • PDF

Recommended Practice for Demand Factor using Regression Analysis Theory depending on Power Consumption Characteristics in General Hospitals (종합병원의 전력소비 특성을 고려한 회귀분석이론을 이용한 수용률 기준 설정)

  • Kim, Se-Dong;Shin, Hyo-Seop;Kim, Soo-Gil;Oh, Kie-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.233-237
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the general hospitals and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 32 general hospitals and 9 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimun and thus it was carried linear and nonlinear regression analysis.

  • PDF

A Study on Comparative Analysis of Power Consumption Characteristics and the revulsion of investment on the application of a BESS in Subway Substation (도시철도 변전소 단위구간의 전력사용 실태 및 피크제어용 BESS 도입에 따른 경제성 분석)

  • Jung, Hyun-Ki;Kim, Se-Dong;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.85-90
    • /
    • 2014
  • This paper shows a reasonable demand power, that was made by the systematic and statistical way considering actual conditions, such as investigated transformer capacity and peak power for the last 6 years of subway substation customer as to AMR. In this dissertation, it is necessary to analyze the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimum and thus it was carried by the linear and nonlinear regression analysis. And we studied on the application of a BESS. Analysis showed that the revulsion of capital is about 3 years and 4 months.

An investigation of normal range of tongue color in numerical coordinate (정상 설색의 수치적 기준에 관한 고찰)

  • Kim, Changhee;Kim, Kiwang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.3
    • /
    • pp.215-223
    • /
    • 2013
  • Objectives Although tongue diagnosis is one of major diagnostic methods in east Asian traditional medicine, the standard of normal tongue color have not established. So we tried to suggest the method to establish the standard of normal tongue color range and the pilot data about the normal range. Materials and methods: 22 precedent study papers that presented the numerical data of normal (light red) tongue color were analyzed. At the same time, 46 adult people tongue color data were also collected and analyzed. Results Precedent studies showed remarkable fluctuations of the range of normal tongue color. Collected tongue color data of the 46 people showed mean Hue value 2 and standard deviation 14 in HSB system. Additionally, 3 ways of standard establishment for normal tongue color were suggested. Conclusion We suggest statistical method as a reasonable method for tongue color standard establishment and $2{\pm}14$ as a reference Hue value for normal tongue color.

Recommended Practice for Lighting Load Density by Feature Parameters and Regression Analysis depending on Power Consumption Characteristics in Subway Stations (회귀분석이론을 이용한 지하철 역사의 조명부하밀도 분석)

  • Jung, Hyeon-Ki;Kim, Se-Dong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.254-259
    • /
    • 2006
  • It is increased electrical energy consumption with the development of intelligence society in the subway station and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design load density in subway stations, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 34 subway stations and 10 electrical design offices. In this dissertation, it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, maximum and thus it was carried linear and nonlinear regression analysis.

  • PDF

A Study of Eliminating NNSS Speed Error by Use of Deviation of NNSS Position Error (NNSS 선위오차의 편차를 이용한 속도오차소법에 관한 연구)

  • 양창진
    • Journal of the Korean Institute of Navigation
    • /
    • v.4 no.1
    • /
    • pp.1-18
    • /
    • 1980
  • As the NNSS system calculates ship's position by the doppler shift of the NNSS radio waves caused by the change of the distance between Transit Satellite and the ship, ship's speed error inevitably results in the position error, and moreover this kind of erroris most dominant compared with other errors especially in high speed ships and airplanes. Most NNSS receivers now in use have adoptedsuccessive short doppler counts as positioning data and by investigating the dispersion of serval successive positions calculated and by neglecting the mean position having dispersion of over certain threshold level, more accurate adn safe position is to be achieved. This paper proposes the method of finding ship's true speed by selecting a speed having least position dispersion for given successive doppler counts. And by computer simulation it was verified that the method proposed here is reasonable in finding the ship's desired correct speed together with the correct ship's position.

  • PDF

Recommended Practice for o Reasonable Design Demand Factor and Analysis of Power Consumption Characteristics by Loads in Office Buildings (사무소용 빌딩의 부하종별 전력소비특성 분석 및 수용률 기준 정립에 관한 연구)

  • Kim, Se-Dong;Lee, Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.111-118
    • /
    • 2005
  • It is increased electrical energy consumption with the development of intelligence society in the once buildings and thus an energy conservation through efficient use of electricity became more important. This paper shows a reasonable design demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, peak power consumption, demand factor, etc., for 54 office buildings and 34 electrical design offices. In this dissertation it is necessary to analyse the key features and general trend from the investigated data. It made an analysis of the feature parameters, such as average, standard deviation, median, maximum, minimum and thus it was carried the linear and nonlinear regression analysis.