• Title/Summary/Keyword: real-time patient monitoring

Search Result 113, Processing Time 0.023 seconds

Development of ROM Measurement Device capable of IoT-based Real-time Monitoring for Rehabilitation Patients (재활환자를 위한 IoT 기반의 실시간 모니터링이 가능한 ROM 측정 장치 개발)

  • Kang, Min-Soo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • In this thesis, the range of motion of the joint was measured using a flexible sensor without using a goniometer, and the measured values were transferred to a smart device. Current range of joint motion measurement is measured by a person using a goniometer. Since the method of measuring by a person is different according to the measuring method and position of the measuring person, it is difficult to make consistent measurement, and an error may occur. The sensor for measurement is a flexible sensor that measures the resistance value that changes according to the movement of the joint. The sensed value can be transmitted to the smart device wirelessly through the ROM sensor node. Also, the sensed analog values were converted to digital values using an ADC. The converted value can be transmitted to the smart device wirelessly through the sensor node. The developed ROM measuring device can perform more consistent measurement than the measurement using general articulator and real time monitoring by interlocking with smart device, so that rapid diagnosis according to the movement of the joint can help the patient's rapid treatment and rehabilitation medical advancement will be.

Ontology-based u-Healthcare System for Patient-centric Service (환자중심서비스를 위한 온톨로지 기반의 u-Healthcare 시스템)

  • Jung, Yong Gyu;Lee, Jeong Chan;Jang, Eun Ji
    • Journal of Service Research and Studies
    • /
    • v.2 no.2
    • /
    • pp.45-51
    • /
    • 2012
  • U-healthcare is real-time monitoring of personal biometric information using by portable devices, home network and information and communication technology based healthcare systems, and fused together automatically to overcome the constraints of time and space are connected with hospitals and doctors. As u-healthcare gives health service in anytime and anywhere, it becomes to be a new type of medical services in patients management and disease prevention. In this paper, recent changes in prevention-oriented care is analyzed in becoming early response for Healthcare Information System by requirements analysis for technology development trend. According to the healthcare system, PACS, OCS, EMR and emergency medical system, U-healthcare is presenting the design of a patient-centered integrated client system. As the relationship between the meaning of the terms is used in the ontology, information models in the system is providing a common vocabulary with various levels of formality. In this paper, we propose an ontology-based system for patient-centered services, including the concept of clustering to clustering the data to define the relationship between these ontologies for more systematic data.

  • PDF

Studies on Effective Fluid Monitoring Terminal design with the Use of location-based service (위치기반서비스를 활용한 효율적인 수액 모니터링 단말기 디자인에 관한 연구)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.4
    • /
    • pp.421-426
    • /
    • 2016
  • Fluid is normally used so that certain drug can be administered to patients for certain period of time. There are many incidents in which patients or guardians need to call upon medical staff after estimating the time of fluid injection termination. In case fluid injection is terminated during certain period such as sleeping time or others, it may cause more fatigue for either patients or guardians. Also, it may lead to ineffective work as medical staff needs to monitor the quantity of fluid several times in order to check the time of fluid injection termination. Therefore, the purpose of this study is to propose LBS system combined of minimum equipment and active RFID to monitor the level of fluid in order to solve abovementioned problems. Also, it is expected to enhance the quality of medical service with service in which real-time monitoring of fluid quantity and patient location is conducted to provide accurate information to either patients, guardians, or medical staff(nurse) so that medical staff can locate and see patients at the time of fluid injection termination.

Self-Organizing Middleware Platform Based on Overlay Network for Real-Time Transmission of Mobile Patients Vital Signal Stream (이동 환자 생체신호의 실시간 전달을 위한 오버레이 네트워크 기반 자율군집형 미들웨어 플랫폼)

  • Kang, Ho-Young;Jeong, Seol-Young;Ahn, Cheol-Soo;Park, Yu-Jin;Kang, Soon-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.7
    • /
    • pp.630-642
    • /
    • 2013
  • To transmit vital signal stream of mobile patients remotely, it requires mobility of patient and watcher, sensing function of patient's abnormal symptom and self-organizing service binding of related computing resources. In the existing relative researches, the vital signal stream is transmitted as a centralized approach which exposure the single point of failure itself and incur data traffic to central server although it is localized service. Self-organizing middleware platform based on heterogenous overlay network is a middleware platform which can transmit real-time data from sensor device(including vital signal measure devices) to Smartphone, TV, PC and external system through overlay network applied self-organizing mechanism. It can transmit and save vital signal stream from sensor device autonomically without arbitration of management server and several receiving devices can simultaneously receive and display through interaction of nodes in real-time.

Novel Real Time PCR Method for Detection of Plasmodium vivax (새로운 Real Time PCR 방법을 통한 Malaria(Plasmodium vivax)의 검출)

  • Ki, Yeon-Ah;Kim, So-Youn
    • Microbiology and Biotechnology Letters
    • /
    • v.33 no.2
    • /
    • pp.148-153
    • /
    • 2005
  • Malaria is a re-emerging infectious disease that is spreading to areas where it had been eradicated, such as Eastern Europe and Central Asia. To avoid the mortality from malaria, early detection of the parasite is a very important issue. The peripheral blood smear has been the gold standard method for the diagnosis of malaria infection. Recently, several other methods have been introduced for quantitative detection of malaria parasites. Real time PCR that employs fluorescent labels to enable the continuous monitoring of PCR product formation throughout the reaction has recently been used to detect several human malaria parasites. 18S rRNA sequences from malaria parasites have been amplified using Taqman real time PCR assay. Here, a SYBR Green-based real time quantitative PCR assay for the detection of malaria parasite-especially, Plasmodium vivax - was applied for the evaluation of 26 blood samples from Korean malaria patients. Even though SYBR Green-based real time PCR is easier and cheaper than Taqman-based assay, SYBR Green-based assay cannot be used because 18S rRNA cannot be specifically amplified using 1 primer set. Therefore, we used DBP gene sequences from Plasmodium vivax, which is specific for the SYBR Green based assays. We amplified the DBP gene from the 26 blood samples of malaria patients using SYBR Green based assay and obtained the copy numbers of DBP genes for each sample. Also, we selected optimal reference gene between ACTB and B2M using real time assay to get the stable genes regardless of Malaria titer. Using selected ACTB reference genes, we successfully converted the copy numbers from samples into titer, ${\sharp}$ of parasites per microliter. Using the resultant titer from DBP based SYBER Green assay with ACTB reference gene, we compared the results from our study with the titer from Taqman-based assay. We found that our results showed identical tendency with the results of 18S rRNA Taqman assay, especially in lower titer range. Thus, our DBP gene-utilized real time assay can detect Plasmodium vivax in Korean patient group semi-quantitatively and easily.

Integration of Wireless Body Area Networks (WBANs) and WAN, WiMAX and LTE

  • Hu, Long;Dung, Ong Mau;Liu, Qiang;Han, Tao;Sun, Yantao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.5
    • /
    • pp.980-997
    • /
    • 2013
  • Nowadays, wireless communication has a great advantage in technology. We use wireless devices almost in all expected life such as: entertainment, working and recently in the healthcare area, where Wireless Body Area Networks (WBANs) become a hot topic for researchers and system designers. Recent work on WBANs focus on related issues to communication protocol, especially ZigBee network is fine tuned to meet particular requirements in healthcare area. For example, some papers present real-time patient monitoring via ZigBee communication given the short distance between body sensors and remote devices, while the other work solve the limited coverage problem of Zigbee by designing mechanisms to relay Zigbee data to other types of wire or wireless infrastructure. However, very few of them investigate the scenarios of ZigBee coexisting or integrated with other networks. In this paper, we present the real-time data transmission from ZigBee end devices to Wide Area Network (WAN), Worldwide interoperation for microwave access network (WiMAX) and Long Term Evolution network (LTE). We provide in detail the ZigBee gateway components. Our simulation is conducted by OPNET, we visualize many topology network scenarios in ZigBee hybrid system. The results in simulation show that ZigBee end devices can successfully transmit data in real-time to other network end devices.

A decision support system the interface between PACS and Laboratory Information (PACS 와 임상검사정보의 연동으로 인한 의사결정시스템; 크레아틴 수치정보전송으로 인한 조영제 부작용 예방)

  • Kim, Sean-Chil;Cho, Hune
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.17-19
    • /
    • 2007
  • This study applies in case of operating an exam using by the contrast order or inputting an order of a contrast media the exam of Radiology Department. It is developed for helping decision making as regards a process of an exam from reading the creatinine value automatically linked with Laboratory Information System. It can be confirmed by real-time information; therefore, the creditability of the information is able to be improved. We will create the base for Patient Monitoring System with the data from the side effect of the creatinine value and allergies. Decision Support System minimize the inconvenience and the riskiness of the given contrast medium for CT tests. We would like to improve medical services by providing a standard circumstance where patients are able to run tests safely and comfortably.

  • PDF

Study on bubble detection sensor for safe sap and blood injection

  • Yun, Young Gi;Lee, Hoo Young;Park, Koo Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.9
    • /
    • pp.149-154
    • /
    • 2017
  • The infusion of fluid and blood is necessary in the ward, operating room, recovery room, neonatal room, etc. for nutrition and blood supply to the patient, but air bubbles generated during infusion of fluid and blood circulate along the artery or vein. Serious illnesses occur and there is also a risk of death. In this paper, we propose a medical bubble detection system, a bubble detection system, a bubble detection alarm system, and a communication method in order to develop a safer fluid and blood injection system in the existing system, which is detected by a medical staff monitoring system or an ultrasonic bubble detection sensor In this study, infrared rays are transmitted to a tube through a tube for injecting fluid or blood into a patient, infrared rays transmitted by an infrared ray emitting section are received, and the amount of light is measured in real time. Based on the data, we study how to detect and analyze the presence of bubbles in fluid and blood.

Explainable Machine Learning Based a Packed Red Blood Cell Transfusion Prediction and Evaluation for Major Internal Medical Condition

  • Lee, Seongbin;Lee, Seunghee;Chang, Duhyeuk;Song, Mi-Hwa;Kim, Jong-Yeup;Lee, Suehyun
    • Journal of Information Processing Systems
    • /
    • v.18 no.3
    • /
    • pp.302-310
    • /
    • 2022
  • Efficient use of limited blood products is becoming very important in terms of socioeconomic status and patient recovery. To predict the appropriateness of patient-specific transfusions for the intensive care unit (ICU) patients who require real-time monitoring, we evaluated a model to predict the possibility of transfusion dynamically by using the Medical Information Mart for Intensive Care III (MIMIC-III), an ICU admission record at Harvard Medical School. In this study, we developed an explainable machine learning to predict the possibility of red blood cell transfusion for major medical diseases in the ICU. Target disease groups that received packed red blood cell transfusions at high frequency were selected and 16,222 patients were finally extracted. The prediction model achieved an area under the ROC curve of 0.9070 and an F1-score of 0.8166 (LightGBM). To explain the performance of the machine learning model, feature importance analysis and a partial dependence plot were used. The results of our study can be used as basic data for recommendations related to the adequacy of blood transfusions and are expected to ultimately contribute to the recovery of patients and prevention of excessive consumption of blood products.

Design and Implementation of a Wearable $SpO_2$ Module based WSN (무선센서네트워크 기반의 손목 착용형 $SpO_2$ 모듈 설계 및 구현)

  • Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.495-498
    • /
    • 2008
  • This paper describes design of a real-time, wearable reflectance pulse oximetry which is based Wireless Sensor Network. For the purpose of continuously monitoring vital signs of a human, wearable reflectance pulse oximetry is built into a wrist type that can be obtained $SpO_2$ value of patient unobtrusively. This designed $SpO_2$ module is based on a low-power 8 bit ATmega128L microcontroller operating in 3V. Low power operating $SpO_2$ module was integrated to wireless sensor node for user's health monitoring. This paper is focused on the successful integration of all these components into wearable reflectance pulse oximetry and evaluates its ability to measure patient' $SpO_2$ value. Information from this sensor was wirelessly transmitted to a base-station for storage and display purposes.

  • PDF