• Title/Summary/Keyword: ray.

Search Result 20,659, Processing Time 0.042 seconds

Doses of Pediatric and X-ray Examination Assistants according to Changes in Pediatric X-ray Exposure Conditions (소아 X선 촬영조건 변화에 따른 소아 및 촬영보조자 선량)

  • Beom-Jin Jang;Ha-Yun Nam;Hye-Min Shin;Dong-Min Yun;Seung-Kook Lee;In-Hwa Jang;Sungchul Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.5
    • /
    • pp.409-415
    • /
    • 2023
  • Although pediatric X-ray examinations are continuously increasing, there are not many studies on the radiation exposure to children and X-ray examination assistants according to X-ray Exposure conditions. Accordingly, we measured the radiation exposure dose of pediatric and X-ray examination assistants according to the standard guidelines and clinical average X-ray Exposure conditions when X-ray examination 10-year-old children. The effective dose and organ dose to pediatric were measured using an Dose area production meter and Monte Carlo-based PCXMC program, and the exposure dose of X-ray examination assistants was measured using an ion-chamber. When performing abdominal supine AP projection, the effective dose to children was up to 2.38 times higher under clinical average X-ray Exposure conditions than the standard guidelines. In addition, during abdominal supine AP projection, the radiation exposure dose to the X-ray examination assistants was highest on the hands at 0.0148 ~ 0.0709 mSv, and exposure dose could be reduced by up to 35% when wearing protective gloves. In conclusion, because the X-ray Exposure conditions used in clinical are unnecessarily high, unnecessary medical radiation exposure could be reduced if appropriate X-ray Exposure conditions and the radiation field area were minimized and the assistant wore shielding gloves.

Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors (휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석)

  • Byung-Wuk Kang;Sun-Kook Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.897-902
    • /
    • 2023
  • The purpose of this paper is to analyze the characteristics of Silicon Photomultiplier (SiPM) for the realization of high-sensitivity radiation detection in portable detectors. Portable X-ray detectors offer the advantage of quickly accessing the patient's location and obtaining real-time images, allowing physicians to perform rapid diagnoses. However, this mobility comes with challenges in achieving accurate radiation detection. In existing detectors, SiPM is used for a simple purpose of detecting X-ray triggers. To verify the feasibility of high-sensitivity X-ray detection through SiPM, seven types of SiPM sensors were compared and selected, and their characteristics were analyzed. The SiPM used in the final test demonstrated the ability to distinguish signals at the ultra-low radiation level of 10 nGy, and it was observed that the slope of the signal rise curve varies with the X-ray tube voltage. Utilizing the characteristics of SiPM, which exhibits changes in signal level and duration with X-ray dose, it appears possible to achieve high-sensitivity measurements for X-ray detection.

Change of the Scattered Dose by Field Size in X-ray Radiography (X선 촬영에서 조사야 크기에 따른 산란선량의 변화)

  • Choi, Seong-Kwan
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.3
    • /
    • pp.198-203
    • /
    • 2013
  • The purpose of this study is to investigate the scattered dose of X-ray at a distance of 30cm from the area to be examined when X-ray field is the most optimized and maximized when X-ray is performed on hand, skull and abdomen. As a result of scattered dose of X-ray on hand, skull and abdomen, first, when X-ray field was the most optimized upon adult X-ray examination, it was $0.08{\mu}Sv$, $4.39{\mu}Sv$ and $5.56{\mu}Sv$, respectively. When x-ray field was maximized, it was $0.58{\mu}Sv$, $33.47{\mu}Sv$ and $35.93{\mu}Sv$, respectively. Second, when X-ray field was the most optimized upon pediatric X-ray examination, it was $0.40{\mu}Sv$, $14.51{\mu}Sv$ and $18.86{\mu}Sv$, respectively. When x-ray field was maximized, it was $2.78{\mu}Sv$, $107.40{\mu}Sv$ and $117.52{\mu}Sv$, respectively(P<0.001). As a result, when the size of X-ray field was decreased down to be necessary and optimal upon X-ray examination, emission of scattered X-ray around specimen is reduced approximately 6-7 times as much as that when it was maximized.

The Development of X-ray Unit of Remote Emergency medical System (원격응급시스템에 적합한 X-ray 장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yang, Hae-Sool;Han, Man-Seok;Han, Sang-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.49-54
    • /
    • 2006
  • The X-ray unit developed by this study is to diagnose emergency cases which is too far from a hospital and to classify the patients. We have to use the X-ray in a ambulance or the scene of an accident where we cannot use the AC220 outlet because of the distance from a hospital as well. The X-ray unit developed has a characteristics as follows. First of all, as the unit has a condenser in itself where there is no electric supply, we can use the X-ray inspector in a mountain area or a island. Second, we can detect by digital detector the information taken by X-ray from DC 12[V] electricity and store as a form of file. A control circuit can secure the reliability of the X-ray unit by using the Pic16F84A X-ray and provide various functions. The X-ray unit which suits remote emergency system can be efficiently used for the emergent cases who is too far from a doctor and a hospital or in the situation where it is difficult to diagnose, transcribe and treat simultaneously.

Gas Typed Digital X-ray Image Sensor Using PDP Fabrication Process (PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서)

  • Kim, Chang Man;Kim, Si Hyung;Nam, Ki Chang;Kim, Sang Hee;Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.322-327
    • /
    • 2012
  • Parallel-plate-type scanning sensors have been commercially used for X-ray imaging sensors. In this study, we manufactured the scan typed 1D X-ray image sensor that can be used to obtain scanning images, by using the plasma display panel (PDP) fabrication process. We fabricated drift and pixel electrodes in the glass chamber and injected Xe gas at atmospheric pressure. We evaluated the intensity of a pixel signal depending on the bias voltage on the drift electrode and investigated the characteristics of shielding effect on the single pixel using lead (Pb). The adsorption rate of X-ray photon is low (4%) on the soda lime glass (1.1mm) and the electrical signal detected on the X-ray sensor was increased in the high bias voltage. We acquired digital X-ray scanning image with our DAS (data acquisition system) and sensor scanning system.

3D Non-local Means(NLM) Algorithm Based on Stochastic Distance for Low-dose X-ray Fluoroscopy Denoising (저선량 X-ray 영상의 잡음 제거를 위한 확률 거리 기반 3차원 비지역적 평균 알고리즘)

  • Lee, Min Seok;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.61-67
    • /
    • 2017
  • Low-dose X-ray fluoroscopic image sequences to avoid radiation exposure risk are contaminated by quantum noise. To restore these noisy sequences, we propose a 3D nonlocal means (NLM) filter based on stochastic distancesed can be applied to the denoising of X-ray fluoroscopic image sequences. The stochastic distance is obtained within motion-compensated noise filtering support to remove the Poisson noise. In this paper, motion-adaptive weight which reflected the frame similarity is proposed to restore the noisy sequences without motion artifact. Experimental results including comparisons with conventional algorithms for real X-ray fluoroscopic image sequences show the proposed algorithm has a good performance in both visual and quantitative criteria.

Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

  • Kim, Gyehong;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.272-276
    • /
    • 2016
  • To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the study was to addresses the anode heel effect and off-axis spectra for different target angles. MCNPX has been utilized to simulate the diagnostic x-ray tube with the aim of predicting optimum target angle and angular distribution of x-ray intensity around the x-ray target. For simulation of x-ray spectra, MCNPX was run in photon and electron using default values for PHYS:P and PHYS:E cards to enable full electron and photon transport. The x-ray tube consists of an evacuated 1 mm alumina envelope containing a tungsten anode embedded in a copper part. The envelope is encased in lead shield with an opening window. MCNPX simulations were run for x-ray tube potentials of 70 kV. A monoenergetic electron source at the distance of 2 cm from the anode surface was considered. The electron beam diameter was 0.3 mm striking on the focal spot. In this work, the optimum thickness of tungsten target was $3{\mu}m$ for the 70 kV electron potential. To determine the angle with the highest photon intensity per initial electron striking on the target, the x-ray intensity per initial electron was calculated for different tungsten target angles. The optimum anode angle based only on x-ray beam flatness was 35 degree. It should be mentioned that there is a considerable trade-off between anode angle which determines the focal spot size and geometric penumbra. The optimized thickness of a target material was calculated to maximize the x-ray intensity produced from a tungsten target materials for a 70 keV electron energy. Our results also showed that the anode angle has an influencing effect on heel effect and beam intensity across the beam.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

A New X-Ray Image Sensor Utilizing a Liquid Crystal Panel (새 구조의 액정 엑스선 감지기)

  • Rho, Bong-Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • We developed a new x-ray image sensor utilizing a reflection-mode liquid crystal panel as its sensitive element, and tested its functionality by using it to obtain an x-ray image of a printed circuit board. In the liquid crystal x-ray image sensors hitherto reported, the liquid crystal layer is in direct contact with the photoconductive film which is deposited on a glass substrate. In the fabrication of the new x-ray image sensor, a liquid crystal panel is fabricated in the first step by using a pair of glass plates of a few centimeters thicknrss. Then one of the glass substrates is ground until its thickness is reduced to about $60\;{\mu}m$. After polishing the glass plate, dielectric films for high reflectance at 630 nm, a film of amorphous selenium for photoconduction, and a transparent conductive film for electrode are deposited in sequence. The new x-ray image sensor has several merits: primarily, fabrication of a large area sensor is more easily compared with the old fashioned x-ray image sensors. Since the reflection type liquid crystal panel has a very steep response curve, the new x-ray sensor has much more sensitivity to x-rays compared with the conventional x-ray area sensor, and the radiation dosage can be reduced down to less then 20%. By combining the new x-ray sensor with CCD camera technology, real-time x-ray images can be easily captured. We report the structure, fabrication process and characteristics of the new x-ray image sensor.

The Effect of Applying the X-ray Screening Ability Rating for Security Screening Persons in Incheon International Airport (인천국제공항 보안검색요원 X-ray 판독등급제 적용 효과)

  • Yung-Kil Lee;Jeong-Sun Baek;Dong-Min Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.733-739
    • /
    • 2023
  • The purpose of this study verify to the effect of applying the X-ray screening ability rating for security screening persons in Incheon International Airport. Data collected through a evaluation score of 1,034 security screening persons in Incheon International Airport. Data analysis performed using paired sample t-test. The research results found that it was a statistically significant difference pre-test and post-test applying the X-ray screening ability rating. In this article, we asserts that the X-ray screening ability rating is effective in improving the X-ray screening ability of security screening persons. This paper contribute to the academic expansion of motivation theory and self-determination theory. This study is valuable as a preemptive empirical research that provides practical implications about the application of X-ray screening ability rating for security screening persons.