• Title/Summary/Keyword: ray number

Search Result 1,127, Processing Time 0.028 seconds

The Clinical Features of Endobronchial Tuberculosis - A Retrospective Study on 201 Patients for 6 years (기관지결핵의 임상상-201예에 대한 후향적 고찰)

  • Lee, Jae Young;Kim, Chung Mi;Moon, Doo Seop;Lee, Chang Wha;Lee, Kyung Sang;Yang, Suck Chul;Yoon, Ho Joo;Shin, Dong Ho;Park, Sung Soo;Lee, Jung Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.671-682
    • /
    • 1996
  • Background : Endobronchial tuberculosis is definded as tuberculous infection of the tracheobronchial tree with microbiological and histopathological evidence. Endobronchial tuberculosis has clinical significance due to its sequela of cicatrical stenosis which causes atelectasis, dyspnea and secondary pneumonia and may mimic bronchial asthma and pulmanary malignancy. Method : The authors carried out, retrospectively, a clinical study on 201 patients confirmed with endobronchial tuberculosis who visited the Department of Pulmonary Medicine at Hangyang University Hospital from January 1990 10 April 1996. The following results were obtained. Results: 1) Total 201 parients(l9.5%) were confirmed as endobronchial tuberculosis among 1031 patients who had been undergone flexible bronchofiberscopic examination. The number of male patients were 55 and that of female patients were 146. and the male to female ratio was 1 : 2.7. 2) The age distribution were as follows: there were 61(30.3%) cases in the third decade, 40 cases(19.9%) in the fourth decade, 27 cases(13.4%) in the sixth decade, 21 cases(10.4%) in the fifth decade, 19 cases(9.5%) in the age group between 15 and 19 years, 19 cases(9.5%) in the seventh decade, and 14 cases(7.0%) over 70 years, in decreasing order. 3) The most common symptom, in 192 cases, was cough 74.5%, followed by sputum 55.2%, dyspnea 28.6%, chest discomfort 19.8%, fever 17.2%, hemoptysis 11.5%, in decreasing order, and localized wheezing was heard in 15.6%. 4) In chest X-ray of 189 cases, consolidation was the most frequent finding in 67.7%, followed by collapse 43.9%. cavitary lesion 11.6%, pleural effusion 7.4%, in decreasing order, and there was no abnormal findings in 3.2%. 5) In the 76 pulmanary function tests, a normal pattern was found in 44.7%, restrictive pattern in 39.5 %, obstructive pattern in 11.8%, and combined pattern in 3.9%. 6) Among total 201 patients, bronchoscopy showed caseous pseudomembrane in 70 cases(34.8%), mucosal erythema and edema in 54 cases(26.9%), hyperplastic lesion in 52 cases(25.9%), fibrous s.enosis in 22 cases(10.9%), and erosion or ulcer in 3 cases(1.5%). 7) In total 201 cases, bronchial washing AFB stain was positive in 103 cases(51.2%), bronchial washing culture for tuberculous bacilli in 55 cases(27.4%). In the 99 bronchoscopic biopsies, AFB slain positive in 36.4%. granuloma without AFB stain positive in 13.1%, chronic inflammation only in 36.4%. and non diagnostic biopsy finding in 14.1%. Conclusions : Young female patients, whose cough resistant to genenal antitussive agents, should be evaluated for endobronchial tuberculosis, even with clear chest roentgenogram and negative sputum AFB stain. Furthermore, we would like to emphasize that the bronchoscopic approach is a substantially useful means of making a differential diagnosis of atelectasis in older patients of cancer age. At this time we have to make a standard endoscopic classification of endobronchial tuberculosis, and well designed prospective studies are required to elucidate the effect of combination therapy using antituberculous chemotherapy with steroids on bronchial stenosis in patients with endobronchial tuberculosis.

  • PDF

Comparative Analysis of Delivery Management in Various Medical Facilities (의료기관별 분만관리 양상의 비교 분석)

  • Park, Jung-Han;You, Young-Sook;Kim, Jang-Rak
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.4 s.28
    • /
    • pp.555-577
    • /
    • 1989
  • This study was conducted to compare the delivery management including laboratory tests, medication and surgical procedures for the delivery in various medical facilities. Two university hospitals, two general hospitals, three hospitals, two private obstetric clinics, and two midwifery clinics in a large city were selected as they permitted the investigators to abstract the required data from the medical and accounting records. The total number of deliveries occurred at these 11 facilities between 15 January and 15 February, 1989 was 789 among which 606(76.8%) were vaginal deliveries and 183 (23.3%) were C-sections. For the normal vaginal deliveries, CBC, Hb/Hct level, blood typing, VDRL, hepatitis B antigen and antibody, and urinalysis were routinely done except the private clinics and midwifery clinics which did not test for hepatitis B and Hb/Hct level at all. In one university hospital ultrasonography was performed in 71.4% of the mothers and in one general hospital liver function test was done in 76.7% of the mothers. For the C-section, chest X-ray, bleeding/clotting time and liver function test were routinely done in addition to the routine tests for the normal vaginal deliveries. Episiotomy was performed in 97.2% of the vaginal deliveries. The type and duration of fluid infused and antibiotics administered showed a wide variation among the medical facilities. In one university hospital antibiotics was not administered after C-section at all while in the general hospitals and hospitals one or two antibiotics were administered for one week on the average. In one private clinic one pint of whole blood was transfused routinely. A wide variation was observed among the medical facilities in the use of vitamin, hemostatics, oxytocics, antipyreptics, analgesics, anti-inflammatory agents. sedatives. digestives. stool softeners. antihistamines. and diuretics. Mean hospital day for the normal vaginal deliveries of primipara was 2.6 days with little variation except one hospital with 3.5 days. Mean hospital day for the C-section of primipara was 7.5 days and that of multipara was 7.6 days and it ranged between 6.5 days and 9.4 days. Average hospital fee for a normal vaginal delivery without the medical insurance coverage was 182,100 Won for the primipara and 167,300 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 82,400 Won and a multiparous mother paid 75,600 Won. Average hospital fee for a C-section without the medical insurance was 946,500 Won for the primipara and 753,800 Won for the multipara. In case of the primipara covered by the medical insurance a mother paid 256,200 Won and a multiparous mother paid 253,700 Won. Average hospital fee for a normal vaginal delivery in the university hospitals showed a remarkable difference, 268,000 Won vs 350,000 Won, as well as for the C-section. A wide variation in the laboratory tests performed for a normal vaginal delivery and a C-section as well as in the medication and hospital days brought about a big difference in the hospital fee and some hospitals were practicing the case payment system. Thus, standardization of the medical care to a certain level is warranted for the provision of adequate medical care for delivery.

  • PDF

The study on the cleft lip and/or palate patients who visited Dept. of Orthodontics, Seoul National University Dental Hospital during last 11 years (1988.3-1999.2) (최근 11년간 서울대학교병원 교정과에 내원한 순구개열 환자의 내원 현황에 관한 연구(1988.3 - 1999.2))

  • Yang, Won-Sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.467-481
    • /
    • 1999
  • Cleft lip and/or palate is one of the most common congenital craniofacial anomalies. According to previous epidemiologic studies, incidence of cleft lip and/or palate has been increasing nowadays. However, there is no report about epidemiologic study of cleft lip and/or palate patients who visited dept. of orthodontics in Korea. So the purpose of this study was to provide the epidemiological characteristics and important basic clinical data for the diagnosis and the treatment of the cleft lip and/or palate patients. With the orthodontic and cleft charts, diagnostic models and X-ray films from 250 patients with cleft lip and/or palate who visited Dept. of Orthodontics, Seoul National University Dental Hospital during the last 11 years, the authors investigated patient's visiting yew, types of cleft, patient's gender, and Angle's classification of malocclusion, and surgery timing. The results were as follows ; 1. The number of cleft patients who visited Dept. of Orthodontics, SNUDH increased during 1988-1990 and then it declined until 1992. From 1993 to 1996, it showed a stationary trend. After 1997 it showed an overwhelmingly increasing trend. 2. In the cleft type, the ratio of cleft lip cleft lip and alveolus cleft palate : cleft lip and palate was 7.6:19.2:9.6:63.6. In cleft position, unilateral clefts were more than bilateral ones (cleft lip 79:21, cleft lip and alveolus 77:23, cleft lip and palate 75.5:24.5). In cleft side, left clefts were mote than right clefts (cleft lip 53.3:46.7 cleft lip and alveolus 59.5:40.5, cleft lip and palate 59.2:40.8). 3. In gender ratio, males were more than females in cleft lip (57.9:42.1), cleft lip and alveolus (68.8:31.2) and cleft lip and palate (76.1:23.9). But in cleft Palate females were more than males as 41.7: 58.3. 4. In the age groups, 7-12 year group was the most abundant as $52\%$, and then 0-6 year group ($20.4\%$), 13-18 year group ($17.2\%$), more than 18 yew group ($10.4\%$) were followed as descending order. 5. Most of the cleft lip repair surgeries were operated in 0-3 month ($60.3\%$) and 4-6 month ($17.9\%$). 6. The cleft palate repair surgeries were done in 1-2 year ($31.7\%$), 0-1 year ($25.6\%$), 2-3 year ($12.1\%$), more than 5 year ($11.6\%$) as descending order. 7. The lip scar revision surgeries were done before admission at elementary school in $60\%$. (4-6 you ($27.5\%$), 6-8 year ($19.6\%$), more than 10 year ($19.6\%$), 2-4 year ($13.7\%$) as descending order) 8. The rhinoplasties were done before admission at elementary school in $51.7\%$. (0-2 year ($7.1\%$), 2-4 year ($14.3\%$), 4-6 year ($21.4\%$), 6-8 year ($14.3\%$)). 9. The pharyngeal flap were done at 6 Y (72.5 months) after birth on average and there was even distribution of surgery timing. 10. In relationship between Angle's classification of malocclusion and cleft types, Class I was most abundant and Class III, Class II were followed as descending order in cleft lip group. But Class III was most abundant and Class I, Class II were followed as descending order in cleft lip and alveolus group, cleft palate group, and cleft lip and Palate group. The percentage of frequency in Class III malocclusion was overwhelmingly higher in cleft lip and palate group than any other groups. 11. Because the frequency of class III malocclusion was most prevalent in all age groups, anterior crossbite was the most common chief complaint of cleft patients.

  • PDF

A Survey on the Perception of the Counterplans of Medical Accident and Dispute of Dental Hygienist (의료사고 및 의료분쟁에 대한 치위생사의 인식도 조사)

  • Oh, Jin-Ho;Kwon, Jeong-Seung;Ahn, Hyoung-Joon;Kang, Jin-Kyu;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.1
    • /
    • pp.9-33
    • /
    • 2007
  • In the field of dentistry, there existed relatively few emergency patients or patients who need intensive care and thus had low medical dispute rates. However, these days, there is a general tendency of increased medical disputes. Although many medical disputes are caused by medical accidents of the dentists, because dental assistants are also lawfully involved in practicing dentistry, there is a possibility of medical disputes or medical accidents caused by dental assistants. Therefore, the role of the dental assistants cannot be ignored. This study consists of a survey given to dental hygienists currently working in general hospitals, dental hospitals and private dental clinics. Following is the results of the analysis of 275 respondents' backgrounds, medical disputes rates including patients' complaints, their understanding of medical regulations and their general understanding of overall dental practice and medical disputes. 1. 251 of 274(91.6%) respondents doubted the risk of medical accident and dispute. 2. 81(29.5%) dental hygienist experienced complaint from patients. They have been working in the private dental clinic, the rate of this experience was high. 3. 349 case of 1805(19.3%) the complaints by patients, highest percentage among its category, were those regarding dental fees and poor service. 4. 129 case of 1805(7.1%) patients' complaints, highest percentage among it's subcategory, were those regarding the absence of explanations of precautions or request of agreements before dental treatment. 5. 252 of 267 (94.4%) dental hygienists chart after a scaling treatment. However, only 55(20.7%) dental hygienists chart the fact of explaining the precautions. 6. 6(2.2%) dental hygienists do not inspect patients' medical history, if patients don't mention it. 7. 104 of 274(38.0%) dental hygienists responded to be capable of administering first aid treatment. 8. 115(41.8%) dental hygienists have a first aid kit and equipment. 9. In case of medical dispute, 268(97.8%) dental hygienists respond that, charting plays a big role in resolving the dispute. 10. In case of medical dispute, 272(93.3%) dental hygienists respond that, explanation and agreement before treatment have an important role in settlement of dispute 11. Only 160(58.4%) dental hygienists responded correct answer that the duration of keeping medical records is 10 years. 12. 124(45.3%) respondents thought that it is legal for a dental hygienist to take a panoramic dental X-ray, 71(25.9%) respondents thought that it is legal practice cervical resin treatment by dental hygienist, and 37(13.5%) respondents thought that it is legal extract primary teeth by dental hygienist. 13. 24(18.76%) respondents thought that it doesn't matter to tell patient's state to others 14. 272(99.27%) responded that receiving education for the prevention of medical disputes was needed and of them, 61.0% thought it was urgent. 15. 186(64.2%) has never had classes regarding the prevention of medical disputes while in school and 212(77.4%) has not had the same type of classes after graduating from school. 16. 256(93.4%) responded that there will be even more of an increased number of medical disputes. Among them, 83.3% of respondents though that due to the increased opportunity of acquiring information through the internet and mass media. The study shows that 29.5 percentage of dental hygienists have experienced the medical disputes and complaints and they are lack of recognition of medical regulations and dental hygienist's official duty. So, there is a big potential of the percentage to increase. Therefore, the correct understanding of explaining precautions and requesting agreement before dental treatments and performing them are mandatory. Moreover, classes regarding the prevention and counterplans of medical disputes need to be widely offered.

Anatomical Studies on Root Formation in Hypocotyl and Epicotyl Cuttings of Woody Plants (임목(林木)의 배축(胚軸) 및 유경삽수발근(幼茎揷穗発根)의 해부학적(解剖学的) 연구(研究))

  • Choi, Man Bong
    • Journal of Korean Society of Forest Science
    • /
    • v.52 no.1
    • /
    • pp.1-30
    • /
    • 1981
  • The origin and development of adventitious roots was studied using hypocotyl and epicotyl cuttings of 34 species, 24 genus of woody plants. These cuttings obtained from young seedlings cultured in vials containing distilled water only. The several characteristics of cuttings materials studied are shown in Table 1. The results are summerized as follows: 1. The circumference shapes of cross-sections of hypocotyl and epicotyl cuttings can be divided into six categories, namely, round, irregular round, ellipse, irregular ellipse, square, and triangle. Species differences within a genus did not show any difference of hypocotyl and epicotyl cross-sections shape, however, a noticeable variation among genus or higher taxa. 2. The arrangements of vascular bundles in the cross-sections of hypocotyls or epicotyls were almost all collateral types and generally showed generic characteristics differing one to the other. However, there were some variations between species within the genus. Six models of vascular bundle arrangement were proposed for all the above speices. 3. The rooting portions of hypocotyl and epicotyl cuttings in this experimental materials can be grouped as follows: (1) Interfascicular parenchyma; (Thuja orientalis. T. orientalis for. sieboldii, Acer microsieboldianum, A. palmatum, A. saccharinum, Cercis chinensis, Lespedeza bicolor, Magnolia obovata, M. sieboldii, Mallotus japonicus, Staphylea bumalda) (2) Cambial and phloem parenchyma: (Chamaecyparis obtusa, C. pisifera, Albizzia julibrissin, Buxus microphylla var. Koreana, Cereis chinensis, Euonymus japonica, Firmiana platanifolia, Lagerstroemia indica, Ligustrum salicinum, L. obtusifolium, Magnolia kobus, M. obovata, Mallotus japonicus, Morus alba, Poncirus trifoliata, Quercus myrsinaefolia, Rosa polyantha, Styrax japonica, Styrax obassia) (3) Primary ray tissues; (Euonymus japonica, Styrax japonica) (4) Leaf traces; (Quercus acutissima, Q. aliena) (5) Cortex parenchyma; (Ailanthus altissima) (6) Callus tissues; (Castanea crenata, Quercus aliena, Q. myrsinaefolia, Q. serrata) 4. As a general tendency throughout the species studied, in hypocotyl cuttings, the adventitious root primordia were originated from the interfascicular parenchyma tissue, however, leaf traces and callus tissues were contributed to the root primordia formation in epicotyl cuttings. The hypocotyl cuttings of Ailanthus altissima exhibited a special performance in the root primordia formation, this means that cortex parenchyma was participated to the origin tissue. And in Firmiana platanifolia, differening from the other most species, the root primordia were formed at the phloem parenchyma adjacent outwardly to xylem tissue of vascular bundle system as shown photo. 48. 5. All the easy-to, or difficult-to root species developed adventitious roots in vials filled with distilled water. In the difficult-to-root species, however, root formations seemed to be delayed because they almost all had selerenchyma or phloem fiber which gave some mechanical hindrance to protrusion of root primordia. On the other hand, in the easy-to-root species they seemed to form them more easily because they did not have the said tissues. The rooting portions between easy-to-root and difficult-to-root species have not clearly been distinguished, and they have multitudinous variations. 6. The species structured with the more vascular bundles in number compared with the less vascular bundles exhibited delayed rooting. In the cuttings preparation, the proximal end of cuttings was closer to root-to-stem transition region, the adventitious root formation showed easier. 7. A different case occured however with the mature stem cuttings, in both the needle-leaved and the broad-leaved species. In the hypocotyl cuttings, parenchymatous tissues sited near the vascular bundles become the most frequent root forming portions in general and relevant distinctions between both species were hardly recognizable. 8. In the epicotyl cuttings, root primordia originated mainly in leaf traces in connection with cambial and phloems or callus tissues itself. In the hypocotyl cuttings, interfascicular parenchyma was the most frequent portion of the root primordia formation. The portions of root primordia had more connection with vascular cambium system, as the tissues were continuing to be developed.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF