• Title/Summary/Keyword: ray code

Search Result 184, Processing Time 0.035 seconds

Automatic ray-code generation for efficient ray tracing (효율적인 파선추적을 위한 파선코드 자동 생성에 관한 연구)

  • 이희일
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.55-62
    • /
    • 2000
  • In constructing a synthetic seismogram using ray-tracing method a suite of ray-code is required to obtain a realistic seismogram which is similar to the actual seismogram or earthquake record under consideration. An infinite number of rays exist for any arbitrarily located source and receiver. One select only a finite number of such rays in computing a synthetic seismogram so their selection becomes important to the validity of the seismogram being generated. Missing certain important rays or an inappropriate selection of ray-codes in tracing rays may result in wrong interpretation of the earthquake record or seismogram. Automatic ray-code generation will eliminate such problems. In this study we have developed an efficient algorithm, with which one can generate systemastically all the ray-codes connecting source and receiver arbitrarily located. The result of this work will helpful in analysing multiple reflections in seismic data processing as well as simulating Lg wave and multiply reflected or converted phases in earthquake study.

  • PDF

The Effects of the Q-Ray View on Reliability of Assessing a Tooth Status for Dental Hygiene Process (Q-Ray View 활용이 치위생과정을 위한 치아 검사의 신뢰도 향상에 미치는 영향)

  • Oh, Hye-Young;Jung, Hoi-In;Ku, Hye-Min;Kim, Baek-Il
    • Journal of dental hygiene science
    • /
    • v.14 no.4
    • /
    • pp.461-467
    • /
    • 2014
  • The objective of this study was to evaluate the impact of the Q-ray view, a novel optical device on reliability of assessing a tooth status by dental hygiene students in the training for dental hygiene process. Twenty patients were enrolled in this study. Oral examinations were conducted by both seventeen third-year dental hygiene students and a trained faculty member. Traditional visual inspection was performed in phase I and then re-examined with Q-ray view in phase II. Restoration codes and lesion codes for each tooth were recorded separately according to the predefined criteria. As a measure of reliability, percent agreement and Cohen's kappa were determined. Agreements for each intraoral regions and types of lesion and restoration were calculated. Paired t-test and Pearson chi-square test for two proportions were used to compare mean Cohen's kappa and percent agreement at each phase. For the lesion code, mean kappa values of phase II for intraoral regions were significantly greater than that of phase I (p=0.017). For the both of the lesion code and restoration code, percent agreements of phase II for each types of lesion and restoration were significantly greater than that of phase II (p<0.001 and p<0.001, respectively). Especially difference of percent agreements between phase I and II for incipient caries, caries and fracture were significant for the lesion code (p=0.046, p<0.001, and p=0.029, respectively) and for not restored or sealed, tooth-colored restoration were significant for the restoration code (p<0.001 and p=0.011, respectively). The reliability of assessing a tooth status was improved when the Q-ray view used in dental hygiene student with beginner level of expertise. Q-ray view can be a promising device for conducting and educating the dental hygiene process better.

Medical Image Automatic Annotation Using Multi-class SVM and Annotation Code Array (다중 클래스 SVM과 주석 코드 배열을 이용한 의료 영상 자동 주석 생성)

  • Park, Ki-Hee;Ko, Byoung-Chul;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.16B no.4
    • /
    • pp.281-288
    • /
    • 2009
  • This paper proposes a novel algorithm for the efficient classification and annotation of medical images, especially X-ray images. Since X-ray images have a bright foreground against a dark background, we need to extract the different visual descriptors compare with general nature images. In this paper, a Color Structure Descriptor (CSD) based on Harris Corner Detector is only extracted from salient points, and an Edge Histogram Descriptor (EHD) used for a textual feature of image. These two feature vectors are then applied to a multi-class Support Vector Machine (SVM), respectively, to classify images into one of 20 categories. Finally, an image has the Annotation Code Array based on the pre-defined hierarchical relations of categories and priority code order, which is given the several optimal keywords by the Annotation Code Array. Our experiments show that our annotation results have better annotation performance when compared to other method.

Gamma Ray Shielding Study of Barium-Bismuth-Borosilicate Glasses as Transparent Shielding Materials using MCNP-4C Code, XCOM Program, and Available Experimental Data

  • Bagheri, Reza;Moghaddam, Alireza Khorrami;Yousefnia, Hassan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.216-223
    • /
    • 2017
  • In this work, linear and mass attenuation coefficients, effective atomic number and electron density, mean free paths, and half value layer and $10^{th}$ value layer values of barium-bismuth-borosilicate glasses were obtained for 662 keV, 1,173 keV, and 1,332 keV gamma ray energies using MCNP-4C code and XCOM program. Then obtained data were compared with available experimental data. The MCNP-4C code and XCOM program results were in good agreement with the experimental data. Barium-bismuth-borosilicate glasses have good gamma ray shielding properties from the shielding point of view.

An Implementation of the Adaptive Ray Tracing Method in the Athena Code

  • Kim, Jeong-Gyu;Kim, Woong-Tae;Ostriker, Eve C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.50.1-50.1
    • /
    • 2016
  • The incorporation of radiation from massive stars is essential for modeling the dynamics and chemistry of star-forming clouds, yet it is a computationally demanding task for three-dimensional problems. We describe the implementation and tests of radiative transfer module due to point sources on a three-dimensional Cartesian grid in the Eulerian MHD code Athena. To solve the integral form of the radiation transfer equation, we adopt a widely-used long characteristics method with spatially adaptive ray tracing in which rays are split when sampling of cells becomes coarse. We use a completely asynchronous communication pattern between processors to accelerate transport of rays through a computational domain, a major source of performance bottleneck. The results of strong and weak scaling tests show that our code performs well with a large number of processors. We apply our radiation hydrodynamics code to some test problems involving dynamical expansion of HII regions.

  • PDF

Development of Multi-Type Soft X-ray Ionizer using Radiation Dose Overlapped Effect (선량 중첩을 이용한 멀티형 연 X-선 정전기 제거장치의 개발)

  • Lee, Su Hwan;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.2
    • /
    • pp.28-31
    • /
    • 2018
  • In display and semi-conductor manufacturing process, there are numerous unstable factors such as particle concentration, minimal vibration, changes in magnetic field, or electrostatic that becomes an issue to be managed and controlled. In the recent, X-ray ionization is widely used that is neutralized by separating air or gas molecules in the area where the static must be resolved. The mono-type of X-ray ionizer was not capable to be used in $8^{th}$ generation panels manufacturing plant due to its insufficient ionizing coverage since the panel itself is approximately in $2m{\times}3m$. To resolve the current problem, the development of new type called, "Multi-type X-ray ionizer" has resulted in covering enough ionizing space in $8^{th}$ generation panels industry. Comparing mono and multi types with MCNPX code simulation, the multi one indicates more X-ray flux, efficiency, and ionization performance in comparison with either a mono-type or multi-type in array format. In addition, the ionizing efficiency of overlapping area with multi-type showed 30% higher effectiveness rate as to the ordinary mono-type.

Calculations of Radiation Measurement-Related Correction Factors (방사선 측정관련 보정인자 계산)

  • Shin, Hee-Sung;Ro, Seung-Gy;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • The self-attenuation factor for an $^{198}Au$ sample and the 0.412 MeV gamma-ray penetration ratio in the circular Al-cover of the radiation detector have been determined using an analytical solution and MCNP code. The results show that the self-attenuation factors obtained from the analytical solution coincide with those of MCNP code for all but the Au sample with the relatively larger radius. Then the maximum difference between the two methods appears to be 9 % in the Au sample of 1.5 mm radius. It also is revealed that the analytical solutions of the 0.412 MeV gamma-ray penetration ratio in the Al-cover of 7.62 cm radius are consistent with those of the MCNP code within the standard deviation.

A study on Algorithm Automatically Generating Ray Codes for Ray-tracing (파선코드 자동생성 알고리즘에 관한 연구)

  • Lee, Hee-Il;Cho, Chang-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 2008
  • When constructing a synthetic seismogram in the earthquake study or in seismic data interpretation by using a ray-tracing technique, the most troublesome and error-prone task is to define a suite of ray codes for the corresponding rays to trace in advance. An infinite number of rays exist for any arbitrarily located source and receiver in a medium. Missing certain important rays or an inappropriate selection of ray codes in tracing rays may result in wrong interpretation of the earthquake record or seismogram. Automatic ray code generation could be able to eliminate those problems. In this study we have developed an efficient algorithm with which one can generate systematically all the ray codes for the source(s) and receiver(s) arbitrarily located in a model. The result of this work could be used not only in analysing multiples in seismic data processing and interpretation, but also in coda wave study, study on the amplification effects in a basin and phase identification of the waves multiply reflected/refracted in earthquake study.

The Performance Test of Anti-scattering X-ray Grid with Inclined Shielding Material by MCNP Code Simulation

  • Bae, Jun Woo;Kim, Hee Reyoung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.2
    • /
    • pp.111-115
    • /
    • 2016
  • Background: The scattered photons cause reduction of the contrast of radiographic image and it results in the degradation of the quality of the image. In order to acquire better quality image, an anti-scattering x-ray gird should be equipped in radiography system. Materials and Methods: The X-ray anti-scattering grid of the inclined type based on the hybrid concept for that of parallel and focused type was tested by MCNP code. The MCNPX 2.7.0 was used for the simulation based test. The geometry for the test was based on the IEC 60627 which was an international standard for diagnostic X-ray imaging equipment-Characteristics of general purpose and mammographic anti-scatter grids. Results and Discussion: The performance of grids with four inclined shielding material types was compared with that of the parallel type. The grid with completely tapered type the best performance where there were little performance difference according to the degree of inclination. Conclusion: It was shown that the grid of inclined type had better performance than that of parallel one.

The Study on Quantum Efficiency of $CaWO_4$ Screen with Diagnostic X-ray (진단 X선에 대한 $CaWO_4$ 증감지의 양자효율 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.379-382
    • /
    • 2002
  • Lately, intensifying screen of the $CaWO_4$ is used to medical treatment and diagnosis of the image. In this paper, we investigated transmission fraction and mass attenuation coefficient of $CaWO_4$ screen about diagnostic x-ray of low energy using MCNP 4C code. Experimentally, for 0.9 mm-$CaWO_4$ screen, the absorbable rate of diagnostic x-ray is more than 95%. according to kVp, the experimental value of mass attenuation coefficient is in a1most agreement with an corrected estimate value of MCNP and the deviation of experimental values is less than ${\pm}7%$. Using the MCNP code through this paper, we can make an estimate of signal and design for construction of the CaWO4/a-Se based digital x-ray image detector and make a good use of the foundation data for development of other materials.

  • PDF