• 제목/요약/키워드: ratio transformer

검색결과 397건 처리시간 0.027초

전류 분할 및 통합 자기 구조를 가지는 새로운 승압형 푸쉬-풀 전력 변환 회로 (A New Isolated Boost Push-Pull Power Conversion Circuit with Distributed Current and Integrated Magnetic Structure)

  • 노정욱;김현수;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.20-23
    • /
    • 1998
  • An improved current-fed push-pull PWM converter with integrated magnetics is presented. With this improved topology, the design of magnetic elements such as an inductor and a transformer becomes easier than that using the conventional topology, especially when the converter is suffered from an extremely high input current. Since this gives twice the voltage conversion ratio compared to the conventional one, it is also suited for the high voltage step-up power conversion process. The operation of the proposed converter is thoroughly analyzed. Also, the theoretical analysis and experimental results are taken from the laboratory level prototype.

  • PDF

벌크형 광 CT 센서 및 신호처리부 성능 개선 방안 연구 (A Study on Performance Improvement of Optical Current Transformer and Signal Processor)

  • 김영수;박병석;김명수;임용훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1929-1932
    • /
    • 2002
  • In this paper, some parameters are studied for the performance improvement of a bulk optical current sensor. The performance of optical current sensor is influenced by current measuring range, Verdet constant change due to temperature change, temperature variation of wave plate, signal to noise ratio of optical transmitter/receiver, optical bias mismatch. Two types of optical current sensors are implemented and tested in the current range from 10 ampere to 200 ampere.

  • PDF

코호넨 특징 대응을 이용한 변압기 고장 인식 및 해석 (Transformer Fault Recognition and Interpretation Using Kohonen Feature Mapping)

  • 윤용한;김재철;최도혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.864-866
    • /
    • 1997
  • This paper presents fault recognition and interpretation in power transformers using dissolved gas analysis embedded Kohonen feature mapping. The imprecision of gas ratio analysis in dissolved gas analysis are managed by mapping in accordance with learning of Kohonen neural network. To verify the effectiveness of the proposed system, it has been tested by the historical gas records to power transformers of Korea Electric Power Corporation. More appropriate fault types can support the maintenance personnels to increase the disgnostic performance for fault of power transformers.

  • PDF

SPICE를 이용한 Forward DC-DC 콘버어터 해석 (An Analysis of Forward DC-DC Converter Using SPICE Program)

  • 김희준;안태영;이영선
    • 전자공학회논문지B
    • /
    • 제28B권5호
    • /
    • pp.411-420
    • /
    • 1991
  • In this paper, SPICE program which is widely used in analysis of general circuit on electronic and electrical field has been applied to DC-DC converter. We have selected Forward type which is widely used us SMPS(Switched Mode Power Supply) of various electronic equipments, and have confirmed the waveforms of circuit operation, transfer of energy and resetting in transformer. And the procedure which the output voltage of converter, including the control circuit, has been stabilized from the transient state to the steady state by controlling the duty ratio of switch is presented. We have compared SPICE simulation with experiment and have verified the validity of SPICE simulation.

  • PDF

2단 자기스위치를 사용한 고속 펄스발생기의 동작 특성 (Operation characteristics of fast pulse generator using a 2-stage magnetic switch)

  • 김복권;권순걸;서기영;이현우
    • 전자공학회논문지B
    • /
    • 제33B권10호
    • /
    • pp.139-147
    • /
    • 1996
  • In this study a two-stage fast pulse generaor using magnetic switches is proposed. The scheme consist of a switch, an inductor and two pairs of capacitor and saturable inductors, a linear transformer. The basic principle and the operation are described using a set of given parameters. The main issue of the magnetic pulse genration scheme is the system efficiency. This study focuses on the system efficiency improvement using magnetic switches. The voltage compression ratio, energy transfer with respect to core area are investigated. The output voltage and transferred energy as a function of input voltage are also included. Also, an analysis and experiments are performed to verify the porposed topology by implementing a 10[J] class experimental circuit. The efficiency of the transferred energy a tload side is 82%.

  • PDF

인터리브드 풀 브릿지 컨버터와 단상 하프 브릿지 인버터를 이용한 1.5kW급 PCS 설계 (Design of 1.5kW PCS Using Interleaved Full-Bridge Converter and Single Phase Half-Bridge Inverter)

  • 나광수;나종국;이희준;신수철;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.403-404
    • /
    • 2013
  • In this paper, a PCS which consists of high boost interleaved full-bridge converter and single phase half-bridge inverter is proposed. Proposed PCS is using two full bridge converter modules. PCS consists of parallel input / serial output. It can reduce turn ratio of high frequency transformer. In this paper, PCS which is using 1.5[kW] interleaved full-bridge converter and single phase half bridge inverter is designed and verified stability of system through experiment.

  • PDF

스위치 손실 분석을 통한 슈퍼커패시터용 양방항 DC-DC 컨버터의 변압기 권선비 설계 (Design of Transformer Turn-ratio through Switch Loss Analysis in Bidirectional DC-DC Converter for EDLC)

  • 김학수;정재헌;노의철;김인동;김흥근;전태원;최남섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.3-4
    • /
    • 2013
  • 본 논문은 슈퍼커패시터용 양방향 DC-DC 컨버터의 충 방전 시의 스위치 손실 분석을 통한 변압기 권선비 설계에 관한 내용이다. Dual Full-Bridge 방식의 양방향 DC-DC 컨버터의 충 방전 동작분석을 통하여 스위치에서 발생하는 손실을 분석하고 변압기 권선비를 달리하여 각 손실을 비교했을 때 가장 작은 손실을 갖는 변압기 권선비를 파악하여 설계에 반영하였다.

  • PDF

1, 2종 흡수식 히트펌프의 작동 매체에 따른 성능 해석[I] (Thermodynamic Analysis of an Absorption Heat Pump System with New Working Pairs[I])

  • 원승호;이원용;정헌생
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.219-227
    • /
    • 1989
  • Performance analysis of an absorption heat pump system for solar energy recovery has been done by computer simulation to find improved working pairs. Based on the thermodynamic analysis, the coefficient of performance and mass flow ratio have been calculated to compare two aqueous solutions [LiCl-water, $LiCi-CaCl_2-Zn(NO_3)_2$-water] which were developed for cooling by others, with the conventional LiBr-water solution. As a result of this analysis, the performances of the new aqueous solutions were found to be better than that of LiBr-water solution not only in cooling systems, but also in heating and in heat transformer systems. Their theoretical thermodynamic performance data were given here with.

  • PDF

Equivalent Circuit Model For Switching Performance of Bipolar Spin Transistor

  • Yong Tae, Kim;Gap Yong, Lee
    • 한국반도체및디스플레이장비학회:학술대회논문집
    • /
    • 한국반도체및디스플레이장비학회 2003년도 추계학술대회 발표 논문집
    • /
    • pp.182-185
    • /
    • 2003
  • We have suggested an equivalent circuit model for switching performance of bipolar spin transistor composed of a nonmagnetic metal film (N) sandwiched between two ferromagnetic metal films (F1 and F2). The 'ON' or 'OFF' operation of this equivalent circuit model is simulated by depending on the orientation of the magnetization of F1 and F2 rather than the strength of the external magnetic filed. Changing the coupling coefficient, turn number of two inductances, (L1:L2) like a transformer, and parallel variable resistance R4 connected to L2 at the collector region, we can explain the magnetic characteristics and the dependence of magneto resistance ratio on the orientation of spin-polarized electrons.

  • PDF

전원에 에너지가 회생되는 전류형 DC-DC 콘버어터의 해석 (Analysis of the Current-Fed DC-DC Converter with Energy-Storage Reactor Feeding the Input)

  • 김희준
    • 대한전자공학회논문지
    • /
    • 제20권4호
    • /
    • pp.41-46
    • /
    • 1983
  • The current-fed DC-DC converter has only one energy storage reactor in series with the input for any number of outputs and is insensitive to transformer volt-second unbalance. It is considered that these properties of the converter are considerable advantages over other maltiple-output circuits. The steady-state and dynamic characteristic and stability for the current-fed DC-DC con-verter are analyzed in detail. The analysis is carried out by the state-space averaging method for the operation with the duty ratio less than 50% and is confirmed by the experiment. From the evaluation of stability it is identified that the stability of this converter is excellent as compared with that of the conventional buck type converter.

  • PDF