Evaluation of Errors of Electronic Voltage Transformer using High Voltage Capacitance Bridge and Standard Capacitive divider (고전압 전기용량 브지리와 표준용량분압기를 이용한 전자식 전압변성기의 평가)

  • Han, Sang-Gil;Kim, Yoon-Hyoung;Jung, Jae-Kap;Kang, Jeon-Hong;Lee, Sang-Hwa;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.61-63
    • /
    • 2008
  • We established a system to evaluate the ratio error and phase angle error of electronic voltage transformer using high voltage capacitance bridge and standard capacitors. The uncertainty of evaluation system is about 0.005% in ratio error and 1.5 min in phase angel error.

  • PDF

A multilevel PWM Inverter for Harmonics Reduction (고조파 저감을 위한 다중 레벨 PWM 인버터)

  • Kang, Feel-Soon;Park, Sung-Jun;Kim, Cheol-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.645-651
    • /
    • 2002
  • In this paper, a multilevel PWM inverter employing a cascaded transformer is presented to reduce the harmonics of output voltage and load currents. The proposed PWM inverter consists of two full-bridge modules and their corresponding transformers. The secondarics of each transformer are series-connected. So continuous output voltage levels can be synthesized from the suitable selection of the turns ratio of trasformer. And it appears an integral ratio to input DC source. Because of the cascaded connection of transformers, output filter inductor is not necessary. The operational principles and analysis are explained, and it is compared with a conventional isolated H-bridge PWM inverter. The validity of proposed multilevel inverter is verified through simulated and experimental waveform and their FFT results.

Electrical properties of strontium substitution Rosen type piezoelectric transformer (Sr이 치환된 Rosen 타입 압전변압기의 전기적 특성)

  • Joo, Hyeon-Kyu;Kim, In-Sung;Jeong, Soon-Jong;Kim, Min-Soo;Song, Jae-Sung;Lee, Dae-Soo;Jeon, So-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1305_1306
    • /
    • 2009
  • Recently, piezoelectric transformer is applied to wide fields. Multi layer piezoelectric transformer has the advantage of high step up ratio, high electromechanical coupling coefficient(Kp) and high mechanical quality factor(Qm), however it shows the peeling-phenomenon of electrode, and high price due to high sintering temperature. Therefore this study focus on the method for fabrication of high power rosen type piezoelectric transformers.

  • PDF

Physical Properties and Out-put Characteristics of Piezoelectric Transformer of $Pb(Mg, Te, Mn, Nb)O_3-PZT$ Ceramics with Addition of $CeO_2$ ($CeO_2$을 첨가한 $Pb(Mg, Te, Mn, Nb)O_3-PZT$계 세라믹스의 물리적 성질과 압전트랜스의 출력특성)

  • 박순태;정수태;이종헌
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.9
    • /
    • pp.761-767
    • /
    • 1993
  • Electrical and mechanical properties of Pb(Mg, Te, Mn, Nb)O3-PZT ceramics are investigated as a function of CeO2 addition (0 to 0.3wt%), and the output characteristics of piezoelectric transformer are also presented. The grain size decreased and the shapes of particles were more uniform with the addition of CeO2. The coercive electric field(9500V/cm), mechanical quality factor (2500) and bend strength (1065kg/$\textrm{cm}^2$) were improved by addition of CeO2 0.2wt%. After repetition of a number of stress cycles, the degradation of k33 was not found in this sample. The voltage step-up ratio (Vdc/Vrms) of piezoelectric ceramic transformer (half wavevoltage doubler, load resistor 100M.ohm) was about 950 in a linear region, its value was relatively higher than other materials.

  • PDF

Intelligent Diagnosis System for DGA Using Fuzzy Pattern Classification and Neural Network (퍼지 패턴 분류와 뉴럴 네트워크를 이용한 지능형 유중가스 판정 시스템)

  • Cho, Sung-Min;Kweon, Dong-Jin;Nam, Chang-Hyun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2084-2090
    • /
    • 2007
  • The DGA (Dissolved Gases Analysis) technique has been widely using for fault diagnosis of the power transformers. Some electric power utility company establishes the criteria of DGA to improve reliability, because of difference of operation environment and design of power transformer. In this paper, we introduce intelligent diagnosis system for DGA result of KEPCO (Korea Electric Power Cooperation). This system can classify patterns type of gases ratio that frequently occurs in recent result of gases analysis using Fuzzy Inference. The classification of Patterns let us know that major causes of gases generation based on type of patterns. Finally, Neural Network based on patterns diagnose transformer. NN was trained using result data of DGA of actually faulted transformers recently. Result of intelligent diagnosis system is right well in comparison with actual inner inspection of transformers.

First-Order Sensitivities for FACTS Devices using UPFC Ideal Transformer Model (UPFC 이상변압기 모델을 사용한 유연송전장치 일차민감도 해석)

  • Thomas W. Gedra;Seung-Won An
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.837-846
    • /
    • 2004
  • This paper presents a screening technique for greatly reducing the computation involved in determining the optimal location and types of Flexible AC Transmission System (FACTS) devices in a large power system. The first-order sensitivities of the generation cost for various FACTS devices are derived. This technique requires solving only one optimal power flow (OPF) to obtain sensitivities with respect to FACTS device control variables for every transmission line To implement a sensitivity-based screening technique, we used a new UPFC model, which consists of an ideal transformer with a complex turns ratio and a variable shunt admittance. A S-bus system based on the IEEE 14-bus system was used to illustrate the technique.

The Temperature Distribution and Thermal Stress Analysis of Pole Mold transformer (주상용 몰드변압기의 온도분포와 열응력 해석)

  • 조한구;이운용;한세원;김석수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.4
    • /
    • pp.297-301
    • /
    • 2001
  • In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The one body molding model (Model 1) and air duct model (Model 2) are designed and their temperature distribution are analysed. The temperature rise value is about 105.5 deg in the model 1 and 65.28 de in the model 2. The temperature change of secondary winding is more than primary winding according to load ratio. The concentration part of Von Mises Stress occurs at interface between glass fiber and epoxy.

  • PDF

Fundamental characteristics of a small superconducting transformer (소형초전도변압기의 전기적 기초특성)

  • Oh, Bong-Hwan;Han, Tae-Hee;Na, Wan-Soo;Cho, Jeon-Wook;Lee, Eon-Yong;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.52-54
    • /
    • 1994
  • To demonstrate the applicability of super-conductors to electric power machines, the authors made and tested a small single-phase superconducting transformer. The aim of the study was to determine the fundamental properties of superconducting trans former. Therefore the superconducting transformer has a simple structure, i.e. the high voltage to low one ratio is 2:1 and the iron core is immersed in liquid helium. Fundamental characteristics are obtained through no-load and short-circuit tests. In this paper, the experimental results are described.

  • PDF

Analysis of Transformer Inrush Current Using Wavelet Transform (Wavelet 변환을 이용한 여자돌입현상 해석)

  • Sohn, J.M.;Kang, Y.C.;Nam, S.R.;Kim, S.S.;Park, J.K.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.920-923
    • /
    • 1997
  • This paper describes the analysis of characteristics of inrush current in transformers using wavelet transform. The simulations are performed with various transformer conditions, including transformer switching-on angles and the remanent flux. The ratio between wavelet coeffients is used for analysis.

  • PDF

A Study on the Age Degradation Kinetics of Pole Transformer Oil (주상변압기 절연유의 경년열화반응 속도론에 관한 연구)

  • 남영우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.1
    • /
    • pp.99-105
    • /
    • 1997
  • In the paper, aging of insulating oil in pole transformer has been studied by performing accelerated thermal aging test. Dissolved gases were extracted by air bubbling method. Concentration of dissolved gases were modified by extraction ratio of each gases in insulating oil. Aging of insulating materials were proceeded by thermal degradation and oxidation reaction. Both of the reactions followed zeroch order kinetics. Formation rate equations for hydrocarbons, carbon oxides, and hydrogen were derived. It was conformed by gas analysis and UV-Visible spectrophotometric method that iron core and copper coil in pole transformer act as catalyst during the aging process.

  • PDF