• Title/Summary/Keyword: ratio control

Search Result 9,919, Processing Time 0.034 seconds

Construction of Map for Transient Condition of a Sl Engine and Refinement of Intake Air Model & Fuel Model (가솔린 엔진의 비정상 상태에 대한 Map 구성과 공기 및 연료 모델 개선)

  • 심연섭;강태성;강승표;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.1-8
    • /
    • 2002
  • For gasoline engines, a three-way catalytic converter that has the maximum efficiency at stoichiometric air/fuel ratio is used to clean up the exhaust gas. So a precise air/fuel ratio control is necessary to maximize the catalytic conversion efficiency, For a transient condition, a fred-forward air/fuel ratio control method that estimates the air mass inducted into a cylinder is being used. In this study, a fuel injection map that makes an accurate air/fuel ratio control possible was constructed for the very same transient condition. For the same condition above, intake air model and fuel model were refined so that fuel injection values based on air mass through a throttle valve and intake manifold pressure are equal to the map values.

ABS Sliding Mode Control considering Optimum Road Friction Force of Tyre (타이어의 최적 노면 마찰력을 고려한 ABS 슬라이딩 모드 제어)

  • Kim, Jungsik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 2013
  • This paper presents the sliding mode control methods for anti-lock brake system (ABS) with the friction force observer. Using a simplified quarter car model, the sliding mode controller for ABS is designed to track the desired wheel slip ratio. Here, new method to find the desired wheel slip ratio which produces the maximum friction force between road and tire is suggested. The desired wheel slip ratio is varying according road and tire conditions to produce maximum friction force. In order to find optimum desired wheel slip ratio, the sliding mode observer for friction force is used. The proposed sliding mode controller with observer is evaluated in simulation, and the control design is shown to have high performance on roads with constant and varying adhesion coefficients.

Implementation of Non-time-varying Duty Ratio Transfer Function for Improvement of Control Characteristics Bi-directional Charger (비시변 시비율 전달함수 구현에 의한 양방향 충전기 제어특성 개선)

  • Hwang, Jung-Goo;Kim, Sun-Pil;Han, Sang-Taek;Kim, Ki-Seon;Choo, Young-Bae;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.124-132
    • /
    • 2014
  • In this paper, we implement a non-time-varying transfer function of the duty ratio to improve the control characteristics in a control system that Input voltage and the output voltage is varied, DC / DC converters for bi-directional charging. When control is performed with using controller gain of conventional design, characteristics of the control is varied to fluctuations of the input voltage. The proposed method is the equivalently removing method for duty ratio in entire control block, by voltage controller gain is changed for inverse of the duty ratio. The proposed non-time-varying duty ratio transfer function is applied to DC / DC converter for bi-directional charging. In this paper, feasibility and superiority is verified through PSIM simulations and experiments.

A Comparative Study on A/F Control Characteristics of Liquid and Gaseous Fueled Engines (액체 및 기체연료 엔진의 공연비 제어특성에 관한 비교 연구)

  • 심한섭;신규철;송창섭;선우명호
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.106-114
    • /
    • 2002
  • In this study, the air-fuel ratio(A/F) control characteristics of a liquid and a gaseous fueled engine are investigated. Engine models far both the liquid and the gaseous fueled engine are developed to compare the characteristics of fuel delivery into the cylinder, and the performances of the models are evaluated using the simulation and experiment. The simulation and experimental results show that the gaseous fueled engine has better control performance than that of the liquid fueled engine in terms of the air-fuel ratio control. This study could be used to develop air-fuel ratio control schemes for both the liquid and the gaseous fueled engine.

Study on the control of fuel-air ratio ofgas swirl burner (가스 스월버너의 공연비 제어에 관한 연구)

  • Kim, I.K.;Kim, Y.S.;Kim, Y.H.;Kim, K.S.;Kim, J.W.
    • 한국연소학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.129-138
    • /
    • 1999
  • In this paper, our main issue is that establishing the control procedure of continuous gas flow rate according to combustion fan RPM. For this, first, we decide the optimum operating condition of gas swirl burner through analysis of combustion characteristics - thermal efficiency, combustion efficiency and exhaust gases such as CO, $CO_{2}$, $O_{2}$, $NO_{x}$ and THC. Second, fuel gas flow rate of gas valve is decided with considering excess air ratio and combustion fan RPM is decided by the target of combustion air flow rate. Finally, experimental operating equation is acquired by regression for gas valve and combustion fan. This equation is the control equation of continuous gas flow rate and always gas flow rate is decided by combustion fan operating RPM.

  • PDF

The Improvement on the Empirical Formula of Stormwater Captured Ratio for Water Quality Volume Based Non-Point Pollutants Water Quality Control Basins (WQV 기반 비점오염저감시설의 강우유출수 처리비 경험공식의 개선)

  • Choi, Daegyu;Park, Moo Jong;Park, Bae Kyung;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.1
    • /
    • pp.87-94
    • /
    • 2014
  • According to the technical guideline of water pollutant load management, the rainfall captured ratio which can be estimated by the empirical formula is an important element to estimate reduction loads of non-point pollutants water quality control basin. In this study, the rainfall captured ratio is altered to stormwater captured ratio considering its meaning in the technical guideline of water pollutant load management, and the new empircal formula of stormwater captured ratio is suggested. In order to do this, we calculate stormwater captured ratio by using the hourly rainfall data of seven urban weather stations (Busan, Daegu, Daejeon, Gangreung, Seoul, Gwangju, and Jeju) for 43 years. The regression coefficients of the existed empirical formula cannot reflect the catchment properties at all, because they are fixed values regardless of regions. However the empirical formula of stormwater captured ratio has flexible regression coefficients by runoff coefficient(C), so it is allowed to consider the characteristics of runoff in catchment. It is expected that reduction loads of storage based water quality control basin can be more reasonably estimated than before.

Mobile Target Speed Estimation in Urban Environments with Adaptive Power Control (도시환경에서 적응전력제어를 이용한 이동국 속도추정)

  • Lee, Hyeon-Cheol;Lee, Jong Tae;Ryu, Sang Burm;Kang, Eun Su
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.1
    • /
    • pp.46-50
    • /
    • 2016
  • The adaptive power control of Code Division Multiple Access (CDMA) systems for communications between User Equipments (UEs) with a link-budget based Signal-to-Interference Ratio (SIR) estimate which has distance information is applied to three inner loop power control algorithms. The speed estimation performances of these algorithms with their consecutive Transmit-Power-Control (TPC) ratios are compared to each other, and it is concluded that the speed can be estimated using the TPC ratio information of Consecutive TPC Ratio Step-size Closed Loop Power Control (CS-CLPC) and Fixed Step-size Power Control (FSPC).

Effective Computation for Odds Ratio Estimation in Nonparametric Logistic Regression

  • Kim, Young-Ju
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.4
    • /
    • pp.713-722
    • /
    • 2009
  • The estimation of odds ratio and corresponding confidence intervals for case-control data have been done by traditional generalized linear models which assumed that the logarithm of odds ratio is linearly related to risk factors. We adapt a lower-dimensional approximation of Gu and Kim (2002) to provide a faster computation in nonparametric method for the estimation of odds ratio by allowing flexibility of the estimating function and its Bayesian confidence interval under the Bayes model for the lower-dimensional approximations. Simulation studies showed that taking larger samples with the lower-dimensional approximations help to improve the smoothing spline estimates of odds ratio in this settings. The proposed method can be used to analyze case-control data in medical studies.

Evaluation of Combustion Stability of Idling Speed State (LBT연소를 통한 Idling 운전시의 연소안정성 평가)

  • 이중순;이종승;김진영;정성식;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.66-72
    • /
    • 1999
  • It is necessary to discuss lightening engine parts and reducing the friction of sliding parts to improve fuel consumption and combustion stability at idling condition. Lean best torque combustion which produce maximum power at a lean air-fuel ratio is effective for the reduction of exhaust gas emission and the improvement of fuel consumption. Accordingly, this study deals with the expansion of lean combustible limitation, the combustion stability and the reduction of idle speed through the analysis of combustion characteristics on the base of the control technique of precise air-fuel ratio because it does not need to maximum power at idling condition. The idle speed is increased proportional to ISC(Idle Speed Control) duty ratio. On the other hand the idle speed decreased by lean air-fuel ratio. The COV in engine speed is stable within maximum two percent up to 17.6 mixture ratio by the control of ISC duty ratio.

  • PDF

A Study on Fuzzy Control Algorithm for Prediction of Server service rate in ATM networks (ATM망에서 서버의 서비스율 예측을 위한 퍼지 제어 알고리즘에 관한 연구)

  • 정동성;이용학
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.10B
    • /
    • pp.854-861
    • /
    • 2003
  • In this paper, we proposed the fuzzy control algorithm for efficient buffer control about traffic that is connected in ATM networks. The proposed Fuzzy control algorithm has total traffic arrival ratio, buffer occupancy ratio and Fuzzy set to search for dynamic service rates in server. That is, is based on Fuzzy logic according to the arrival ratio of total traffic and buffer occupancy ratio that is happened and reasoning. Then, made reasoning result control service rates in server about traffic that is connected with defuzzification value. Performance analysis result: it was confirmed that with the proposed scheme, performance improves at cell loss rate, when compared with the existing PBS scheme.