• 제목/요약/키워드: rapid measurements

검색결과 438건 처리시간 0.032초

고체 합성수지절연체와 표면노화 진단기술로서의 부분방전 측정평가기술에 대하여 (Partialt Discharge Measurement Techniques for Diagnosis of Surface Aging on Organic Insulation)

  • 박완기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 춘계학술대회 논문집
    • /
    • pp.50-56
    • /
    • 1994
  • Partial discharge on organic insulation surfaces are an important sauce of aging. Furthermore the modern PD measurement technigues are rapid developed as quality control and diagnostic tests to determine the fitness for use of HV equipment employing sol id electrical insulation. This paper deals with theory of conventional PD measurement and new tendency of technical development on PD measurements und evaluations. Finally the Measuring system used for diagnosing the surface aging on the organic insulation at High Voltage Laboratory of Technical University of Darmstadt in Germany is presented.

  • PDF

안면 비대칭 환자의 하악골 수술 후 하악골 변화에 대한 3차원 CT 영상 비교 (Comparision of Mandible Changes on Three-Dimensional Computed Tomography image After Mandibular Surgery in Facial Asymmetry Patients)

  • 김미령;진병로
    • Journal of Yeungnam Medical Science
    • /
    • 제25권2호
    • /
    • pp.108-116
    • /
    • 2008
  • Background : When surgeons plan mandible ortho surgery for patients with skeletal class III facial asymmetry, they must be consider the exact method of surgery for correction of the facial asymmetry. Three-dimensional (3D) CT imaging is efficient in depicting specific structures in the craniofacial area. It reproduces actual measurements by minimizing errors from patient movement and allows for image magnification. Due to the rapid development of digital image technology and the expansion of treatment range, rapid progress has been made in the study of three-dimensional facial skeleton analysis. The purpose of this study was to conduct 3D CT image comparisons of mandible changes after mandibular surgery in facial asymmetry patients. Materials & methods : This study included 7 patients who underwent 3D CT before and after correction of facial asymmetry in the oral and maxillofacial surgery department of Yeungnam University Hospital between August 2002 and November 2005. Patients included 2 males and 5 females, with ages ranging from 16 years to 30 years (average 21.4 years). Frontal CT images were obtained before and after surgery, and changes in mandible angle and length were measured. Results : When we compared the measurements obtained before and after mandibular surgery in facial asymmetry patients, correction of facial asymmetry was identified on the "after" images. The mean difference between the right and left mandibular angles before mandibular surgery was $7^{\circ}$, whereas after mandibular surgery it was $1.5^{\circ}$. The right and left mandibular length ratios subtracted from 1 was 0.114 before mandibular surgery, while it was 0.036 after mandibular surgery. The differences were analyzed using the nonparametric test and the Wilcoxon signed ranks test (p<0.05). Conclusion: The system that has been developed produces an accurate three-dimensional representation of the skull, upon which individualized surgery of the skull and jaws is easily performed. The system also permits accurate measurement and monitoring of postsurgical changes to the face and jaws through reproducible and noninvasive means.

  • PDF

Rapid Prototyping으로 제작한 3D Medical Model의 오차 측정에 관한 연구 (임상 적용 가능성 및 사례) (ACCURACY TESTS OF 3D RAPID PROTOTYPING (RP) MEDICAL MODELS: ITS POTENTIAL AND CLINICAL APPLICATIONS)

  • 최진영;최정호;김남국;이종기;김명기;김명진;김영호
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제25권4호
    • /
    • pp.295-303
    • /
    • 1999
  • Presented in this paper are the experimental results that measure rapid prototyping (RP) errors in 3D medical models. We identified various factors that can cause dimensional errors when producing RP models, specifically in maxillofacial areas. For the experiment, we used a human dry skull. A number of linear measurements based on landmarks were first obtained on the skull. This was followed by CT scanning, 3D model reconstruction, and RP model fabrication. The landmarks were measured again on both the reconstructed models and the physical RP models, and these were compared with those on dry skull. We focused on major sources of errors, such as CT scanning, conversion from CT data to STL models, and RP model fabrication. The results show that the overall error from skull to RP is $0.64{\times}0.36mm(0.71{\times}0.66%)$ in absolute value. This indicates that the RP technology can be acceptable in the real clinical applications. A clinical case that has applied RP models successfully for treatment planning and surgical rehearsal is presented. Although the use of RP models is rare in the medical area yet, we believe RP is promising in that it has a great potential in developing new tools which can aid diagnosis, treatment planning, surgical rehearsal, education, and so on.

  • PDF

원자력 시설 주변 환경 감시를 위한 토양 중 우라늄 동위원소 신속 분석법 확립 (Establishing of a rapid analytical method on uranium isotopic ratios for the environmental monitoring around nuclear facilities)

  • 박지영;임종명;이현우;이완로
    • 분석과학
    • /
    • 제31권3호
    • /
    • pp.134-142
    • /
    • 2018
  • The uranium isotopic ratio in environmental samples around nuclear facilities is important because it reveals information regarding illegal activities or anthropogenic pollution. Determination of uranium isotopes, however, is a challenging task requiring much labor and time because of the complex separation procedures and lengthy process. In this study, a rapid determination method for uranium isotopes in environmental samples was developed using. The sample was completely decomposed using the alkali fusion method. The separation procedure using extraction chromatography (UTEVA) was simplified in a single step without any further removal process for Si and major matrix elements. The established method can be completed within 3 h from sample dissolution to ICP-MS measurement. Most matrix elements and uranium isotopes in the soil samples were well separated and purified. Five types of were used to assess the method's accuracy and precision for a rapid uranium analysis method. The analytical accuracy for all CRM samples ranged from 95.1 % to 97.8 %, and the relative standard deviation was below 3.9 %. From the analytical results, one may draw conclusions that the evaluated method for uranium isotopes using alkali-fusion, the extraction chromatography process, and ICP-MS measurements is fast and fairly reliable owing to its recovering efficiencies. Thus, it is expected that the evaluated method can contribute to the improvement of environmental monitoring ability.

Precision Assessment of Near Real Time Precise Orbit Determination for Low Earth Orbiter

  • Choi, Jong-Yeoun;Lee, Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • 제28권1호
    • /
    • pp.55-62
    • /
    • 2011
  • The precise orbit determination (POD) of low earth orbiter (LEO) has complied with its required positioning accuracy by the double-differencing of observations between International GNSS Service (IGS) and LEO to eliminate the common clock error of the global positioning system (GPS) satellites and receiver. Using this method, we also have achieved the 1 m positioning accuracy of Korea Multi-Purpose Satellite (KOMPSAT)-2. However double-differencing POD has huge load of processing the global network of lots of ground stations because LEO turns around the Earth with rapid velocity. And both the centimeter accuracy and the near real time (NRT) processing have been needed in the LEO POD applications--atmospheric sounding or urgent image processing--as well as the surveying. An alternative to differential GPS for high accuracy NRT POD is precise point positioning (PPP) to use measurements from one satellite receiver only, to replace the broadcast navigation message with precise post processed values from IGS, and to have phase measurements of dual frequency GPS receiver. PPP can obtain positioning accuracy comparable to that of differential positioning. KOMPSAT-5 has a precise dual frequency GPS flight receiver (integrated GPS and occultation receiver, IGOR) to satisfy the accuracy requirements of 20 cm positioning accuracy for highly precise synthetic aperture radar image processing and to collect GPS radio occultation measurements for atmospheric sounding. In this paper we obtained about 3-5 cm positioning accuracies using the real GPS data of the Gravity Recover and Climate Experiment (GRACE) satellites loaded the Blackjack receiver, a predecessor of IGOR. And it is important to reduce the latency of orbit determination processing in the NRT POD. This latency is determined as the volume of GPS measurements. Thus changing the sampling intervals, we show their latency to able to reduce without the precision degradation as the assessment of their precision.

Efficient Data Management for Hull Condition Assessment

  • Jaramillo, David;Cabos, Christian;Renard, Philippe
    • International Journal of CAD/CAM
    • /
    • 제6권1호
    • /
    • pp.9-17
    • /
    • 2006
  • Performing inspections for Hull Condition Monitoring and Assessment as stipulated in IACS unified requirements and IMO's Condition Assessment Scheme (CAS) IMO Resolution MEPC.94(46), 2001, Condition Assessment Scheme, IMO Resolution MEPC.111(50), 2003, Amendments to regulation 13G, addition of new regulation 13H involves a huge amount of measurement data to be collected, processed, analysed and maintained. Information to be recorded consists of thickness measurements and visual assessment of coating and cracks. The amount of data and increasing requirements with respect to condition assessment demand efficient computer support. Currently, due to the lack of standardization for this kind of data, the thickness measurements are recorded manually on ship drawings or tables. In this form, handling of the measurements is tedious and error-prone and assessment is difficult. Data reporting and analysis takes a long time, leading to some repairs being performed only at the next docking of the ship or making an additional docking necessary. The recently started ED funded project CAS addresses this topic and develops-as a first step-a data model for Hull Condition Monitoring and Assessment (HCMA) based on XML-technology. The model includes simple geometry representation to facilitate a graphically supported data collection as well as an easy visualisation of the measurement results. In order to ensure compatibility with the current way of working, the content of the data model is strictly confined to the requirements of the measurement process. Appropriate data interfaces to classification software will enable rapid assessment by the classification societies, thus improving the process in terms of time and cost savings. In particular, decision-making can be done while the ship is still in the dock for maintenance.

3차원 인체 측정을 이용한 40대 여성의 상반신 체형을 고려한 브래지어 패턴 개발 (Brassiere Pattern Development Based on 3D Measurements of Upper Body Types for Women in Their 40's)

  • 조신현;김미숙
    • 복식문화연구
    • /
    • 제16권3호
    • /
    • pp.502-517
    • /
    • 2008
  • The purpose of the study lies in the measurements of breast shapes and upper body types for the women in their 40's, with the use of 3D measurement system, and in the presentation of brassiere patterns fit for their body types. As for the study method, 3D human body types were analyzed with RapidForm 2006, and the upper-body types and breast shapes were statistically classified through technical statistics analysis, cluster analysis, t-test, variance analysis, and cross analysis. The wearing tests went through the comparison of the brassieres of three makers in the market and the experiment brassieres(first and second) and then the evaluations were made by the subjects, the outer appearance assessment by experts, and 3D measurements. The findings of the study indicated that the evaluation of experiment brassieres was excellent in every item, and he significant difference was found out particularly in the items of pressure, rear center, front center, breast underneath, adequate level by wing, and adequate level by armhole. According to the results of 3D evaluation, experiment brassieres had a highest point in fitness with no physical pressure at the wing part and no overall deviation at the cup art. The pattern comparison showed the differences in the parts of total cup angle, cup circumference length, lower cup height, wing length, and wing angle.

  • PDF

3차원 인체 계측 방법에 의한 상반신 체형을 고려한 브래지어 패턴 설계 - 30대를 대상으로 - (Brassiere Pattern Development Based on 3D Measurements of Upper Body - Focused on Women in Their 30's -)

  • 조신현;김미숙
    • 복식문화연구
    • /
    • 제16권3호
    • /
    • pp.488-501
    • /
    • 2008
  • The purpose of this study presents bra pattern using the 3D measurements of the upper body subject to women in their 30's. Brassieres available in the market are mostly designed for straight body shape and many women seem to have experienced bearing discomfort in a great extent as they grow older. Brassieres should be designed to cover diverse body types and the accurate measurement of body type and breast shape is needed to accomplish that. As for the study method, 3D human body types were analyzed with RapidForm 2006, and the upper-body types and breast shapes were statistically classified through technical statistics analysis, cluster analysis, t-test, variance analysis, and cross analysis. The wearing tests went through the comparison of the brassieres of three makers in the market and the experiment brassieres(first and second) and then the evaluations were made by the subjects, the outer appearance assessment by experts, and 3D measurements. The results of this study showed that the evaluation of experiment brassieres was excellent in every item, and the significant difference was found out particularly in the items of pressure, rear center, front center, breast underneath, adequate level by wing, and adequate level by armhole. According to the results of 3D evaluation, experiment brassieres had a highest point in fitness with no physical pressure at the wing part and no overall deviation at the cup part.

  • PDF

급냉 제강슬래그를 재활용한 EVA-폴리머 시멘트 모르타르의 특성 (Characteristics of EVA-Polymer Modified Mortars Recycling Rapid-chilled Steel Slag Fine Aggregate)

  • 황의환;김진만
    • 공업화학
    • /
    • 제19권6호
    • /
    • pp.652-660
    • /
    • 2008
  • 급냉 제강슬래그를 재활용하기 위하여 제강슬래그의 치환율을 다양하게 변화시켜 만든 EVA-폴리머 시멘트 모르타르의 기계적강도와 물성에 대하여 조사하였다. EVA-폴리머 시멘트 모르타르 공시체는 폴리머-시멘트비를 5단계(0, 5, 10, 15, 20 wt%), 급냉 제강슬래그의 치환율을 5단계(0, 25, 50, 75, 100 wt%)로 각각 변화시켜 총 25 종류의 공시체를 제작하였다. 공시체의 제 성능을 조사하기 위하여 후레쉬 모르타르의 물-시멘트비, 단위용적중량, 공기량과 경화 공시체의 압축 및 휨강도, 흡수시험, 내열수성시험, 세공분포측정 및 SEM에 의한 미세조직 관찰 등을 실시하였다. 그 결과 급냉 제강슬래그의 치환율이 증가됨에 따라 물-시멘트비는 감소되었으나 단위용적중량은 현저히 증가 되었다. 폴리머-혼화제 및 급냉 제강슬래그의 첨가량 증가에 따라 흡수율은 감소되었으나, 압축 및 휨강도는 현저히 증가되었다. 내열수성시험에 의하여 기계적강도는 현저히 감소되었으나, 세공량과 공극률은 현저히 증가되었다. 전자현미경 관찰에서 내열수시험 전의 조직은 견고하게 융착되어 있었으나 내열수시험 후의 조직에서는 폴리머-혼화제가 분해 또는 열화되어 있는 것을 관찰할 수 있었다.

산화인듐아연 박막에 대한 급속 열처리 효과 (Effects of rapid thermal annealing on indium-zinc-oxide films)

  • 김원;방정환;엄현석;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1268_1269
    • /
    • 2009
  • This work shows the effect of rapid thermal annealing (RTA) on properties of indium-zinc oxide (IZO) thin films. The RTA temperatue was controlled between 300 and $500^{\circ}C$ under the two different ambient conditions such as vacuum and oxygen. Structural, optical, and electrical properties of IZO films were characterized in terms of RTA conditions. XRD and resistivity measurements showed that crystallization for IZO films occurred at an RTA temperature of about $400^{\circ}C$. For the IZO film treated at $500^{\circ}C$ of RTA, the resistivity, carrier concentration, hall mobility, and transmittance were approximately $10^2{\Omega}cm$, $10^{15}cm^{-3}$, $10cm^2/V{\cdot}s$, and 85%, respectively, which would be suitable for its application to the channel layer in transparent thin film transistors.

  • PDF