• 제목/요약/키워드: railway tunnel fire

검색결과 73건 처리시간 0.023초

철도차량용 통로연결막 재료별 독성성분의 발생량 비교 (Occurrence quantity comparison of the toxic gases of the railway car's gangway materials using a Smoke Density-Chamber)

  • 이은경;이덕희;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1533-1539
    • /
    • 2007
  • It is mainly due to the toxic gases, produced from the material combustion, threatens human body in case of urban railway car like subway which passes through underground tunnel. In the field of railway industry, fire accidents was not frequent but occurs in each country and, the causes was investigated. The advanced country established the test standard (e.g., BS, EN) to measure the toxic gases quantitatively and, have applied to enhance the fire safety of railway car. We must also follow the procedures to use gangway material for railway car as stated the Safety regulation for the urban railway car. In this study, various gangway materials(silicon, synthtic rubber, soaltapulin) are used to investigate element of toxic gases when the fire occurs. The amount of toxic gases measured from the ISO 5659 chamber using cone heater was measured and compared the results for each materials.

  • PDF

철도터널에서의 화재시 발생되는 연기 온도/발생량 계산 (Calculation of Smoke Temperature/Volume Folw rate in Tunnel Fires)

  • 박원희;장용준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1218-1222
    • /
    • 2007
  • Under various tunnel fires, smoke average temperature and volume flow rate in a tunnel fire are calculated. To obtain realistic results, enthalpy of smoke which composites combustion gases and entrainment air is calculated from curvefit polynomials by temperature.

  • PDF

철도터널 화재시 구난역 내의 연기거동에 미치는 배연효과에 관한 연구 (A Study on Ventilation Effects on Smoke Behavior in Rescue Station for Tunnel Fires)

  • 장원철;김동운;이성혁;유홍선
    • 한국철도학회논문집
    • /
    • 제11권3호
    • /
    • pp.294-299
    • /
    • 2008
  • 본 연구는 구난역을 갖는 철도 터널 내에서 화재가 발생하였을 때 연기 전파 특성에 미치는 배연효과를 다루고 있다. 터널 화재 실험은 4cm의 정사각형 형태의 n-heptane$(C_7H_{16})$ 풀화재(pool fires)에 대해서 수행되었고 다양한 화재 발생위치에 따른 발열량을 측정하였다. 또한, 본 연구에서는 상용코드인 Fluent(Ver.6.3)를 사용하여 구난역을 갖는 철도 터널 내의 연층 전파 특성을 분석하였으며, MVHS(Modified Volumetric Heat Source) 모델을 사용하여 화재에 의한 연소생성물의 농도 및 거동을 예측하였다. 해석 조건은 다양한 화재 발생 위치에 따라서 측정 된 발열량을 이용하였다. 본 연구를 통해 교행로 내에 위치한 방화문에 의해 비사고터널로의 확산을 막을 수 있음을 보였고 특히, 배연시스템의 가동을 통해 유동방향을 변화시킴으로써 사고터널내의 연기 확산을 제어할 수 있음을 확인하였다.

경사터널내 화재 발생시 경사도가 임계속도에 미치는 영향에 관한 연구 (An Experimental Study on the Critical Velocity Considering the Slope in Tunnel Fire)

  • 김승렬;장용준;유홍선
    • 한국철도학회논문집
    • /
    • 제11권1호
    • /
    • pp.7-12
    • /
    • 2008
  • 본 연구에서는 경사각에 다른 임계속도 변화를 파악하기 위하여 축소모형 실험을 수행하였다. Froude 상사를 사용하여 1/20 축소모델 시험을 수행하였고, 화원은 메탄올, 아세톤, 헵탄을 연료로하여 Akinson과 Wu가 사용한 가스버너가 아닌 배연속도에 따라 달라지는 정사각형 풀을 사용하였으며, 터널의 각도는 $0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$, $8^{\circ}$에 관하여 실험을 수행하였다. 발열량과 온도는 로드셀과 K-type 열전대를 사용하여 측정하였다. 실험결과 발열량 변화를 고려하지 않은 Atkinson과 Wu의 실험결과 보다 배연속도에 따른 발열량이 변화하는 풀화재를 사용한 경우가 더 큰 기울기 값을 얻었다. 따라서 배연속도는 화원의 연소율 변화에 직접적으로 영향을 미치기 때문에 경사터널화재 발생시 연소율의 변화에 따른 임계속도의 영향을 고려하는 것이 중요하다.

철도시스템의 확률론적 위험평가 모델 개발 연구 - 터널화재 위험도 평가에의 적용 (Development of Probabilistic Risk Analysis Model on Railroad System - Its Application to Tunnel Fire Risk Analysis)

  • 곽상록;왕종배;홍선호;김상암
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(II)
    • /
    • pp.265-270
    • /
    • 2003
  • Though the probability of tunnel fire accident is very low, but critical fatalities are expected when it occurred. In this study the effect of critical safety parameters on tunnel fire accident are examined using probabilistic technique. Fire detection time, smoke spread velocity, passenger escape velocity, flash-over time, and emergency service arrival time are considered. In order to estimate the uncertainties of input parameters Monte Carlo simulation are used, and fatalities for each assumed accident scenarios are obtained as results. For the efficiency of iterative calculation PRA(Probabilistic Risk Analysis) code is developed in this study. As a result fire detection have large effect.

  • PDF

존 모델을 이용한 종류식 배연 터널 화재시 연기 거동에 대한 수치해석적 연구 (A Numerical Study on Smoke Movement in Longitudinal Ventilation Tunnel Fires Using a Zone Model)

  • 김현정;노재성;김동현;장용준;유홍선
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1319-1324
    • /
    • 2007
  • Many researches have been performed to analyze the smoke movement in tunnel fires by using field model. Recently, FDS(Fire Dynamics Simulator) v.4, which is one of the field model and developed from NIST(National Institute of Standards and Technology), is widely used. In tunnel fires, FDS can show detail results in local point, but it has difficulties in boundary condition and taking long computing time as the number of grid increases. So, there is a need to use alternative method for tunnel fire simulation. A zone model is different kind of CFD method and solves ordinary differential equation based on conservation and auxiliary equations. It shows good macroscopic view in less computing time compared to field model. In this study, therefore, to confirm the applicability of CFAST in tunnel fire analysis, numerical simulations using CFAST are conducted to analyze smoke movement in longitudinal ventilation reduced-scale tunnel fires. Then the results are compared with experimental results. The differences of temperature and critical velocity between numerical results and experimental data are over $30^{\circ}C$ and 0.9m/s, respectively. These values are out of error range. It shows that CFAST 6.0 is hard to be used for tunnel fire simulation.

  • PDF

장대 철도터널에서의 방재 안전성 평가에 관한 연구 (A study on the estimation of safety in long railway tunnel)

  • 김영근;김동현
    • 한국터널지하공간학회 논문집
    • /
    • 제9권3호
    • /
    • pp.287-298
    • /
    • 2007
  • 최근 새로운 철도를 건설하거나 기존선로를 개량하기 위하여 터널의 건설이 급속히 증가하고 있으며, 점점 장대화 되고 있는 실정이다. 그러나 터널이 장대화됨에 따라 터널내에서의 화재사고 발생시 치명적인 대형사고의 가능성이 증대되고 있어, 장대터널에서의 안전성에 대한 관심이 증가하고 있다. 이러한 이유로 터널내 위험도를 최소화하고 터널방재기준을 만족시킬 수 있는 터널내 방재시설에 대한 최적의 설계기준이 요구되고 있으며, 장대 철도터널의 합리적인 설계를 위하여 터널 방재 안전성에 대한 정량적인 평가방법이 필요하다 할 수 있다. 본 연구에서는 정량적 위험도 분석방법인 QRA 기법을 장대터널에서의 방재 안전성 평가에 적용하여 그 유효성을 검토하고자 하였다. 적용사례에서는 장대터널에서의 갱외탈출로 개념의 사갱 및 수직구 계획을 수립하기 위하여 각각의 경우에 대한 QRA분석을 실시하고, 장대터널의 방재 안정성을 평가하므로서 실행 가능한 합리적인 수준의 터널 방재설계를 수행하고자 하였다.

  • PDF

환기를 동반한 철도터널 화재 연기유속 및 온도장 해석 (The Analysis of Fire-Driven Flow and Temperature in The Railway Tunnel with Ventilation)

  • 장용준;이창현;김학범;이우동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1794-1801
    • /
    • 2008
  • 2006년에 고시가 된 "철도시설 안전세부기준"(건설교통부고시 제2006-395호)에 의하면 1km 이상의 철도터널을 건설할 경우 철도터널에 대한 화재 시뮬레이션을 수행하여 철도터널 내부의 화재에 대한 안전성 분석을 실시하도록 되어있다. 철도터널에서 화재에 대한 안전성 분석을 하기 위해서는 실험적 방법과 수치해석을 이용한 방법이 있는데, 본 연구에서는 수치해석적 방법을 이용하여 터널에서의 화재유동 및 온도장 분포를 해석하였으며, 실험 결과와 비교하여 수치해석의 신뢰성 정도를 분석하였다. Fletcher 등이 수행한 모형 터널 실험을 대상으로 수치해석을 수행하였다. 터널 모형은 길이 182m, 높이 2.4m, 폭 5.4m으로 이루어져 있으며, 수치해석에서도 실험과 동일한 상황을 가정하여 해석을 하였다. 화재가 발생한 부분은 터널의 입구로부터 112m 지점이며, pool fire를 사용하였다. 화재 강도는 약 2.76MW이며, 화원으로써는 Octane을 사용하였다. 수치해석을 위하여 LES 기법을 이용한 FDS (Fire Dynamics Simulator)를 사용하였으며, 본 연구에서는 계산 속도를 증속시키고, 단일 CPU에서는 처리가 곤란한 격자수를 처리하기 위하여 여러 개의 CPU를 사용하는 병렬 처리 기법을 활용하였다. 본 연구에서 사용된 총 격자의 개수는 2.4백만개 이며, 사용된 CPU수는 7개 이다. 수치해석 결과와 실험 결과를 비교 분석하여 수치해석의 신뢰성과 FDS의 철도터널 안전성 분석에의 활용 가능성에 대하여 논하였다.

  • PDF

철도터널 화재시 연결통로 및 대피로 제연을 위한 수치해석 연구 (Numerical Simulation of Smoke Ventilation in Rescue Route and Cross Passage of Railroad Tunnel)

  • 양성진;허남건;유홍선;김동현;장용준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.1-10
    • /
    • 2008
  • A transient 3-D numerical simulation was performed to analyze the fire safety in a railway tunnel equipped with a mechanical ventilation system. The behavior of pollutants was studied for the emergency operation mode of ventilation system in case of fire in the center of the rescue station and near the escape route. Various schemes of escape route construction for connection angle($45^{\circ}$, $90^{\circ}$, 135^{\circ}$) and slope($10^{\circ}$) were evaluated for the ventilation efficiency in the fire near the escape route. From the results, it was shown that the mode of the ventilation fan operation which pressurizes the tunnel not under the fire and ventilates the smoke from the tunnel under the fire is most effective for the smoke control in the tunnel in case of the fire occurrence. It was also shown that the blowing of jet fan from the rescue tunnel to the main tunnel should be in the same direction as the flow direction in the main tunnel arising from the traffic and the buoyancy.

터널 내 화재발생에 대한 콘크리트 세그먼트 라이닝의 내화성 평가 및 내화방법에 대한 고찰 (Review of fire resistance evaluation and fire resistance method of concrete segment lining for fire in tunnel)

  • 손무락;천주현;조영근;김범주
    • 한국터널지하공간학회 논문집
    • /
    • 제25권2호
    • /
    • pp.121-139
    • /
    • 2023
  • 도로, 지하철, 철도 등의 다양한 터널이 건설 및 운행 중에 있다. 터널구조물의 구조적 안정을 위해 다양한 형태의 라이닝이 이용되고 있으며 특히 TBM터널 공사에서는 콘크리트 세그먼트 라이닝이 주로 설치되고 있다. 본 논문에서는 터널 내 화재가 발생할 시 터널내 구조물인 콘크리트 세그먼트 라이닝에 미치는 영향 및 관련기준, 내화성 평가 및 내화방법에 대해서 문헌조사를 통해 조사하고 관련내용을 제시하였다. 이를 통해 실무자가 터널화재에 대한 콘크리트 세그먼트 라이닝의 안전을 확보하는데 정보를 제공하고자 하였다.