• Title/Summary/Keyword: railway signal

Search Result 441, Processing Time 0.024 seconds

Handover Performance of LTE-R Networks (LTE-R 네트워크에서 핸드오버 성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1223-1228
    • /
    • 2018
  • LTE-R(Long Term Evolution - Railway), as a mobile communication technology to support safety operation of train on high speed railway system, have to be equipped appropriately by hand-over method for high moving environment of train. In this paper, hand-over performance of LTE-R network, which is used in railway communication system, is analyzed and hand-over implementation condition is suggested with this analysis. The performance analysis of this study is carried out with computer simulation with NS(Network Simulator)-3. SINR(Signal to Interference and Noise Ratio) and RSRP(Reference Signal Received Power), and Data Rate is used for hand-over performance parameter.

Manufacturing Video Clips for Easier Understanding about the Maintenance Procedures of Railway Signal Facilities (신호설비 유지관리절차 동영상 제작)

  • Jung, Ho-Hung;Ko, Yang-Ok;Lee, Nam-Il
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1033-1037
    • /
    • 2010
  • Railway signal facilities are very important because they are directly related to safe train operation. By the result of the unification of signal and station control, station control staffs have been having a hard time to grasp the knowledge about signal facilities and the fault restoration ability in a short term since the existing manuals were only made with text materials. To meet the growing demand to educate the maintenance work in actual and effective way, the maintenance manuals and periodic procedures was developed in the forms of video clips and animations with quality contents onto a DVD enabling not only to improve the maintenance works for signal facilities but to contribute budget saving and profit generating.

  • PDF

A Study on the Application of TEO and STFT Signal Processing Techniques for Detection of Electric Railway Contact Loss (전기철도차량 이선 현상 검측을 위한 TEO 및 STFT 신호처리기법 적용에 관한 연구)

  • Jung, No-Geon;Park, Chul-Min;Lee, Jae-Bum;Park, Young;Shin, Seung-kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1530-1535
    • /
    • 2018
  • In this paper, A technique for detecting contact loss at the input power of a railway vehicle has been studied when the contact loss occurs in the feed system. The impedance of the actual railway line was applied to the modeling of the feed system, and modeling was performed based on the performance of the electric railway vehicle. The input voltage and current of the railway vehicle through modeling were analyzed by applying TEO and STFT signal processing technique.

Post-processor Simulator Construction of Ultrasonic Signals for Integrity Evaluation of Railway Truck (대차 프레임의 건전성평가를 위한 초음파신호 후처리기 시뮬레이터 구축)

  • 이규배;윤인식
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.55-60
    • /
    • 2002
  • This study proposes the post-processor simulator construction of ultrasonic signal for integrity evaluation of railway truck. For these purposes, the ultrasonic signals for defects(crack) of weld zone in frames are acquired in the type of time series data and echo strength. The detection of the natural defects in railway truck is performed using the characteristics of echodynamic pattern in ultrasonic signal. The constructed post-processor simulator agree fairly well with the measured results of test block(defect location, beam propagation distance, echo strength, etc). Proposed post-processor simulator construction of ultrasonic in this study can be used for the integrity evaluation of railway truck.

Study on the Design of Operation Scenario for Replacement of a Railway Signaling System (철도신호시스템 교체에 따른 운행 시나리오 도출에 관한 연구)

  • Jeong, Rag-Gyo;Kim, Baek-Hyun;Kang, Seok-Won;Kho, Young-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1064-1069
    • /
    • 2014
  • The railway signalling system plays an essential role in the headway and routing control for a safe and efficient train operation. The reliable and safe operation of the system is very important because the failure of the railway signalling system can lead to the collision, derailment, or unexpected stop of a train. So far, the conventional wayside signal mode (ATS: Automatic Train Stop) has been generally used as the railway signalling system. However, this system is highly linked to a risk of major accidents resulted from human mistakes such as missing a signal or careless control of train speed. Accordingly, the onboard signal mode (ATC: Automatic Train Control) as an alternative of ATS has been recently introduced and applied to transmit effectively the information on speed control of a train by using computers and communication equipment. In the process of replacing the obsolete signal system, it is necessary to switch over the system while providing passengers with normal services. Therefore, the integration of a railway signaling system compatible for both ATS and ATC and its interface is discussed in this study. In particular, the implementation scenario required for operation planning of the integrated system was designed, and the results as well as effects of its applicability test were also presented.

Safely Evaluation on Common Grounding System for Electric Railway (전기철도의 공용접지 시스템에 대한 안정성 평가에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.298-306
    • /
    • 2002
  • We performed an safety evaluation on constructing of a common grounding system for electrical railway in view of its efficacy and technical fit. In order to compare the conventional grounding method, which has been individually conducted, with the common grounding with all ground wires connected in common to the counterpoise buried below the surface of the earth in parallel with rail, we set up scenarios with several cases of fault and load conditions in Chungbuk railway sections with the common grounding system. Based on models for railway conductors including the grounded system, line Parameters of railway power system are computed. The circuit model for power system with up and down lines, auto-transformers and railway substations is used to compute impedances of counterpoise and substation ground net. For each scenario with faults and operation conditions of railway, the induced potentials on signal and communication lines are also computed. It is shown that the common grounding for Chungbuk railway is superior experimentally to the conventional method in three respects: (1) the lower rail potentials during operation of railway in line, (2) the lower rail potentials for short-circuit faults between catenary and rail, and (3) the lower stress voltages on signal and communication lines for short-circuit or ground faults. The analysis results confirm that the grounding system for electric railway is required to be built by the common grounding and be evaluated on its safety in design.

A Study on Hazard Analysis and Risk Assessment of Railway Signal System Using FTA/ETA Method (FTA/ETA 기법을 이용한 철도신호시스템의 위험 분석 및 위험성 평가에 관한 연구)

  • 백영구;박영수;이재훈;이기서
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.473-480
    • /
    • 2002
  • In this paper, it was proposed that hazard analysis and risk assessment about railway signal systems using FTA(Fault Tree Analysis) and ETA(Event Tree Analysis) one of the reliability analysis methods executed and output value based on the hazard baseline of CENELEC and EC 61508 producted, and also the SIL(Safety Integrity Level)/THR(Tolerable Hazard Rate) about the system set. On the basis of this principle, more systematic standardizations are required to operate railway system and in the future, we hope that safety and reliability of signal equipment will be better improved.

  • PDF

Formal Method for Operational Regulations to Railway Signalling System (철도신호시스템 운용규정에 Formal Method의 적용)

  • Kim, He-Eung;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.856-862
    • /
    • 2006
  • In railway signalling system, there are several kinds of signal system such as signals, signs, marker. The signals allows train to go or not, the signs permit to communicate between railway men, and the marks indicate status of railway lines. In KNR, the application of the signal systems are defined in railway operational regulations, operational related regulation, Operation safety critical system manipulation manual, and so on. In this paper, we extracted regulations for signalling system operation from related regulations, reviewed compatibility and contradiction for signalling system operations. We tried to check logical integrity of informal signalling operation regulation using formal method.

  • PDF

Improvement of Railway Signaling System for KTX and Conventional Trains Operated on a Five-Display Signal System Under a Four-Display Signaling System (4현시 철도신호체계에서 KTX 및 일반열차의 5현시 신호체계 운행을 위한 시스템 개선방안)

  • Lee, See-bin;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.2
    • /
    • pp.162-169
    • /
    • 2016
  • Gyeong-bu railway line in Korea between Seoul and Cheon-an was built as two double tracks. A four-display signaling system, only for the metro line, was installed on the second double track so KTX and conventional trains can only operate on the first double track. This study suggests a method to allow KTX and conventional trains operated on the five-display signaling system to respond to accidents and track defects on the second double-track under the four-display signal system by means of problem analysis, calculation of breaking distances for KTX and conventional trains at each break mode, and improvement of the ATS system.

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.