• Title/Summary/Keyword: railroad system

Search Result 2,236, Processing Time 0.03 seconds

A Analysis on wireless performance of unified data transmission in a subway and railway (18GHz 차지상간통합데이터전송 시스템의 지하 및 지상구간 무선특성 분석)

  • Jeong, Sang-Guk;An, Tae-Ki;Kim, Baek-Hyun;Choi, Gab-Bong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1083-1090
    • /
    • 2009
  • In 18GHz using unified data transmission in a subway and railway, Influence of the multipath fading is big and an arrival range of the micro wave takes the influence greatly according to the transmit angle and receive angle because it not diffracted. This thesis analyzed microwave property underground tunnel and ground railway at unified data transmission in subway and railway. Antenna gain of directional antenna many used unified transmission in an subway and railway, is used 15dBi and 10dBi in simulation. Transmitter's property is compared underground tunnel to ground railway about curved railway of R=100, R=200, R=400. Specification of transmitter is used sample unified transmission system in subway and railway of KRRI(korea railroad research Institute). Transmitter's power is 20dBm and Reciever's sensitivity is -90dBm. According to result of simulation.

Estimation Model of Electric Energy Consumption on Logistics Center Based on Thermodynamics Theory (열역학 이론 기반의 물류센터 전기에너지 소비량 산출 모형)

  • Cui, Lian;Kim, Young-Joo;Kim, Cheolsun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6799-6806
    • /
    • 2015
  • Electric energy consumption is always followed by the introduction of diversity scale-up and state-of-the-art equipments in logistic centers. In order to analyze the status and the characteristic of the electric energy consumption quantitatively, and also to evaluate the efficiency of the electric energy, this research aims to develop an estimation model of standard electric energy consumption for logistic centers. The proposed model applies the thermodynamics theory so as to effectively reflect the peculiarity that the temperature in the logistic center influences the electric energy consumption. And the model consists of the energy consumed by the refrigerator, which can be subdivided into the heat conducted through the wall, the heat convected by the open doors and the heat lost into the goods, and the electric consumption of the machinery equipments. The model also includes a variety of explanatory variables to support an operator of logistics centers in evaluating the efficiency of energy consumption and establishing improvement strategies for energy efficiency. Application of the model developed in this study is discussed with observed data on energy consumption of a logistics center.

TID and SEL Testing on OP-Amp. of DC/DC Power Converter (DC/DC 컨버터용 OP-Amp.의 TID 및 SEL 실험)

  • Lho, Young Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.101-108
    • /
    • 2017
  • DC/DC switching power converters are commonly used to generate a regulated DC output voltage with high efficiency. The advanced DC/DC converter uses a PWM-IC with OP-Amp. (Operational Amplifier) to control a MOSFET (metal-oxide semiconductor field effect transistor), which is a switching component, efficiently. In this paper, it is shown that the electrical characteristics of OP-Amp. are affected by radiations of ${\gamma}$ rays using $^{60}Co$ for TID (Total Ionizing Dose) testing and 5 heavy ions for SEL (Single Event Latch-up) testing. TID testing on OP-Amp. is accomplished up to the total dose of 30 krad, and the cross section($cm^2$) versus LET($MeV/mg/cm^2$) in the OP-Amp. operation is evaluated SEL testing after implementation of the controller board.

Analysis of Non-point Pollution Source Removal Efficiencies according to Rainfall Characteristics in Low Impact Development Facilities with Vegetation (식생이 적용된 비점오염 저감시설의 강우 특성에 따른 효율 분석)

  • Ku, Soo-Hwan;Im, Jiyeol;Oa, Seong-Wook;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.247-255
    • /
    • 2017
  • This research was conducted to analyze removal efficiencies of non-point pollution source (NPS) in low impact development (LID) facilities with vegetation. In this research, removal efficiencies of NPS were calculated using rainfall monitoring data for 5 years in grassed swale (GS) and vegetative filter strip (VFS). TSS was greater than other pollutants, and it ranged 11.9 ~ 351.7 mg/L in GS and 12.8 ~ 350.7 mg/L in VFS. Outflow EMCs were reduced than inflow EMCs, overall removal efficiencies of NPS were 67 ~ 86% in GS and 63 ~ 91% in VFS. 50 % reduction efficiency of rainfall runoff was observed between inflow and outflow in each LID facility. TSS removal efficiency in GS and VFS was correlated with rainfall characteristics. The rainfall for TSS removal efficiency over 50% was determined about 31 mm, 34 mm and average rainfall intensity was 3.0 mm/hr, 3.9 mm/hr in GS and VFS. Therefore, GS and VFS were regarded effective LID facilities as removal of pollutants and rainfall runoff. Also, this research result can be used as an important data for management of NPS.

Train Service Analysis of Intercity Rail Station (지역간 철도역의 열차운행체계 연구)

  • Lee, Jin-Seon;Kim, Gyeong-Tae;Park, Beom-Hwan
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.5
    • /
    • pp.111-122
    • /
    • 2007
  • This paper investigates the rail service patterns by train class. The emphasis in intercity rail planning is to more efficiently use of existing station facilities. Rail transit operations are affected by the system layout and ridership patterns and by work rules. Operations are also influenced by past practices and the institutional setting. Main factors to decide train service patterns are the location, socioeconomic characteristics, land use and travel demand of the station. In this context, the travel demand of intercity rail station is of crucial significance. Tests on a KTX case shows that train service frequency can be efficiently decreased in weekday to transport the same passenger demand. The work has shown many subjects that need further research including various factors influencing on train frequency. This study serves the railroad authorities in planning and determining business strategy in the increasingly competitive environment of regional rail transport.

Estimation of Unit Loads Generation for Swine Wastewater by Cage Test (Cage Test를 통한 양돈폐수 발생원단위 설정)

  • Kim, Yong Seok;Park, Jae Hong;Park, Ji Hyoung;Park, Bae Kyung;Oa, Seong Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.235-240
    • /
    • 2015
  • To evaluate the unit load generation and discharge, pig cage test was conducted. Feed intake, drink amount, and urine generation increased growth stage (heavy weight) of the pig more great. However, the sum of the urine and manure did not show a significant difference in the growth stages of pigs. Because of the limit of the experiment, e.g., research period, high pigpen temperature, breed-related stress and etc., it could not be derived the results of the four seasons. Therefore, in order to generalize the results, the feed intakes were calibrated using a NRC (National Research and nutritional requirements of pigs from the Commission) standards. The finalized unit load generation and generation amounts of manure and urine were estimated at BOD 104.1 g/head/d, T-N 21.2 g/head/d, T-P 4.9 g/head/d, manure 0.96 L/d, urine 1.66 L/d with consideration of revised feed intake. Compare to the former research results of MOE (Ministry of Environment, 1999) and NIAS (National Institute of Animal Science, 2008), the generation amounts of manure and urine were similar to the NIAS's values. In case of unit load generation, BOD and T-N were almost similar in all of them. However, the T-P unit load generation of MOE was more difference, e.g., 2.5 times high, compare to this study.

Automatic Classification of Bridge Component based on Deep Learning (딥러닝 기반 교량 구성요소 자동 분류)

  • Lee, Jae Hyuk;Park, Jeong Jun;Yoon, Hyungchul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.239-245
    • /
    • 2020
  • Recently, BIM (Building Information Modeling) are widely being utilized in Construction industry. However, most structures that have been constructed in the past do not have BIM. For structures without BIM, the use of SfM (Structure from Motion) techniques in the 2D image obtained from the camera allows the generation of 3D model point cloud data and BIM to be established. However, since these generated point cloud data do not contain semantic information, it is necessary to manually classify what elements of the structure. Therefore, in this study, deep learning was applied to automate the process of classifying structural components. In the establishment of deep learning network, Inception-ResNet-v2 of CNN (Convolutional Neural Network) structure was used, and the components of bridge structure were learned through transfer learning. As a result of classifying components using the data collected to verify the developed system, the components of the bridge were classified with an accuracy of 96.13 %.

A Study on the Process of Constructing a Long-Term Railway Network Plan (장기철도망 구축계획의 구축과정에 관한 연구)

  • Seo, Kwang Seok
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.267-275
    • /
    • 2012
  • Long-term national railway building comprehensive review of the proposal had 100 in railway history, railway rail network plan. Planning routes for establishing a plan, but, considering the rail network, the plan was that could with the very important meaning in the What more economical route considering the costs and benefits of building a rail network under budget constraints, went through the process of background lines of business unit interval expenses to adopt a business unit interval. Especially in building the railway network, as well as the road plan was to reflect in order to build for the future railway facilities was secured examine the possibility of possible budget commitment. Budget of securing the transportation tax, gasoline tax, and other transportation facilities in order to secure and commit the current funding approach and Review Bodu possible budget scenarios based on it written. Was also enforce rail system built in reviewing the demand more than anything that can take advantage of the railway distance by railway and the merits of the competition means to compete in the form of the assumed situation. The rail network deployment plan, considering this was discussed, based on the results of the plan to establish the first annual or period of the plan change was based on the budget that was unknown.

Characteristics of Near-field Ground Vibration in Tunnel Blasting using Electronic Detonators (전자뇌관을 이용한 터널발파의 근거리 지반진동 특성)

  • Kim, Yong-Pyo;Kim, Gab-Soo;Son, Young-Bok;Kim, Jae-Hoon;Kim, Hee-Do;Lee, Jun-Won
    • Explosives and Blasting
    • /
    • v.31 no.1
    • /
    • pp.76-86
    • /
    • 2013
  • In order to control tunnel blast vibration for adjacent facilities using electronic detonator, Understanding about the characteristics of near-field ground vibration is necessary. The purpose of this paper is to analyze effects of Cut-area and Extension-area vibration in relation to decision of tunnel blast vibration. These data were obtained at the top monitoring positions while ${\bigcirc}{\bigcirc}{\bigcirc}$ tunnel site of "Wonju~Gangneung double railroad section ${\bigcirc}{\bigcirc}$ construction" was passing under the existing road. Thus, tunnel blasting was conducted by tunnel electronic blasting system with 0.01% high delay-time accuracy. It can be possible that not only keeping maximum charge per delay-time but also preventing amplification of vibration which is occurred by delay-time scatter using common detonators. Additionally, V-Cut was changed into Burn-Cut. The results was presented that vibration level of extension-holes were higher than Cut-holes. Therefore, near-field ground vibration can be effectively minimized using electronic detonators in the Cut area. And also more effective way to reduce tunnel blast vibration is full-face blast using electronic detonators.

A Study of the Current Status and Issues Pertaining to Vertical Separation between Infrastructure and operation of the Korean Railway (철도 상하 분리의 현상과 과제에 관한 연구)

  • Lee, Yongsang;Chung, Byunghyun
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.6
    • /
    • pp.492-502
    • /
    • 2013
  • This paper analyzes the outcomes of railway reform in the form of vertical separation between the infrastructure and operation since 2004 in Korea. For the analysis, the paper reviewed theoretical issues and case studies of European and Japanese railway reforms efforts. By doing this, we find the implications and a standard model, most useful. Moreover, based on this analysis, the paper reviewed the status of the accomplishment of goals, including solution to current account deficits, improvements in competitiveness and greater efficiency of operations. Finally, the paper highlighted improvement measures to address the problems of railway vertical separation in Korea. This paper suggests specifications pertaining to rail policy and control methods; tower foundation and negotiations and mentions ways to establish legal institutionalization and to secure stable rail system investments in railway in Korea.