The Value of Periapical Radiograph in the Diagnosis of Interproximal Caries (구내방사선사진의 인접면 치아우식 진단에 대한 유용성 평가)

  • Kim Young-Hee;Kang Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.30 no.1
    • /
    • pp.49-54
    • /
    • 2000
  • Purpose : To compare the diagnostic performance of clinical and radiologic examination for the interproximal caries on intraoral periapical radiographs and to evaluate the value of periapical radiographs. Methods: One hundred seven dental patients were examined clinically, with a mouth mirror and an explorer, by a dentist at the department of oral medicine, and the presence or absence of interproximal caries lesion was recorded. The patients were prescribed one or more dental periapical radiographs. Radiographs were assessed for the presence of interproximal caries by three oral and maxillofacial radiologists independantly. Two thousand sixty interproximal surfaces were included in this study. The diagnostic accuracies of clinical and radiologic examinations for interproximal caries were calculated. To assess the degree of agreement between clinical and radiologic examinations, Cohen's coefficient of agreement was computed. Results: The specificity of clinical and radiologic examination was 0.991, 0.997 and the sensitivity was 0.279, 0.985 respectively. The diagnostic accuracy of radiologic examination was statistically significantly higher than that of clinical examination (P<0.05). Cohen's kappa value of clinical and radiologic examination was 0.335, 0.942 respectively. These results suggested that clinical examination show only fair agreement, whereas radiologic examination show perfect agreement. Conclusion: The diagnositic performance of the dental periapical radiographs on interproximal caries were higher than that of clinical examination, thus this study showed the validity of periapical radiographs for detecting interproximal caries lesion without bitewing radiograph.

  • PDF

Effect of Low-Dose Radiation on Quality Characteristics of Takju (저선량 방사선 처리가 탁주 품질특성에 미치는 영향)

  • Lee, Yun-Gyu;Tak, Eun-Mi;Kim, Bo-Mi-Na;Seo, Choung-Won;Choi, Seung-Hwan;Shin, Yong-Seob;Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.133-137
    • /
    • 2011
  • This research investigated how low dose radiation affected the quality characteristics of Takju. The treatment group were the quality characteristics of control group, Takju treated by radiation of separate 4, 7, 10 Gy and sterilized Takju. We measured pH, titratable acidity, alcohol, brix, total viable cell count, Hunter's color values, sensory characteristic. As a result, We discovered there were minute changes in pH, titratable acidity, alcohol, brix, total viable cell count. Likewise, The color appeared changes on separate radiation dose. In the sensory characteristic, People's preference ranked better than average level according to priority Takju treated by 4, 7, 10 radiation. In conclusion, Low dose radiation had little effect on the quality characteristics of Takju. However, Takju received a favorable review by some people In test of taste such as after taste. So We thought, such as preservation, the research using the radiation should be continually conducted.

  • PDF

Radiologic Equipment and Technicians according to the Distribution of the Population (인구 분포에 따른 방사선 장비 및 종사자에 관한 고찰)

  • Yoon, Chul-Ho;Choi, Jun-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.57-65
    • /
    • 2009
  • Purpose: The purpose of this paper is to provide basic data in order to systemize the management of demand and supply of radiologic technicians, to pursue a fair regional distribution of educational institutions, and furthermore to keep reasonable medical treatment and fee. This research was carried out through the investigation of radiologic equipments and technicians according to the distribution of the population. Materials and Methods: We compared and analyzed the correlation between regional population, the number of clinics and hospitals, the number of medical imaging devices, and the number of radiologists and radiologic technicians in 5 cities without "Gu" administrative units in 2008. Results: 27,317 radiologic technicians have been produced since the administration of the national qualifying exam for radiologic technicians. About 18,000 radiologic technicians are currently working. There are 39 colleges or universities with Departments of Radiology and the admission quota is 2,120 students excluding one college. The ratio of radiologic equipments to radiologic technicians is 2.6 to 1. Conclusion: There is a dilemma in which some radiologic technicians fail to find appropriate jobs while some clinics or hospitals are in need of radiologic technicians. This dilemma is due to unreasonable regional discrepancies in pay system and welfare situation, and excessive profit-oriented recruiting system of clinics and hospitals. The increase of students of Radiologic Departments and approval of additional departments will end up with producing superfluous high academic degree holders, which is on the contrary to the government policy to produce more job opportunities. So the policy of increasing Radiologic Departments should be reconsidered.

  • PDF

Foreign Bodies in the Chest: How Come They Are Seen in Adults?

  • Tae Jung Kim;Jin Mo Goo;Min Hoan Moon;Jung-Gi Im;Mi-Young Kim
    • Korean Journal of Radiology
    • /
    • v.2 no.2
    • /
    • pp.87-96
    • /
    • 2001
  • The radiologic and clinical findings of foreign bodies in the chest of children are well recognized. Foreign bodies in adults are infrequent, however, and the radiologic findings of these unusual circumstances have rarely been described. We classified various thoracic foreign bodies into three types according to their cause: Type I, Aspiration, Type II, Trauma or Accident; Type III, Iatrogenic. This pictorial essay will illustrate the radiologic findings and consequences of thoracic foreign bodies in adults, which have rarely been described in the radiologic literature. The clinical significance of thoracic foreign bodies will be also be discussed.

  • PDF

RADIOLOGIC VARIABLES AFFECTING EXTRACTION OF I MPATCTED MANDIBULAR THIRD MOLARS (매복 하악 제3대구치의 외과적 발거에 영향을 미치는 방사선학적 변수)

  • Kim, Dong-Hyun;Park, Sung-Bin;Chang, Ic-Jun;Song, Jae-Chul;Chin, Byung-Rho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.3
    • /
    • pp.238-243
    • /
    • 2001
  • Purpose : The purpose of this study was to determine radiologic variables affecting extraction of impacted mandibular third molar. Materials and Methods : This study was investigated on 44 consecutive extractions of unilateral impacted mandibular third molars (Male;34, Female;10, Mean age;24.98, Age range;19-35). Fourteen radiologic variables, which were actual value except only one, were evaluated to establish their relation to the operation time. The Pearson correlation coefficient and Stepwise procedures for regression analysis were carried out. Results : Eight variables (depth, angulation, ramus width, relationship to the second molar, distal ramus depth, mesial ramus depth, mesial periodontal ligament width and follicle) showed a statistically significant relation to the operation time(Pearson correlation coefficient, p<0.05). Two variables, depth and mesial periodontal ligament width, showed the most powerful and just relation to the operation time($r^2$ = 0.349, p<0.05). Conclusion : This study shows that our results can help general practioner to estimate the operation time of extraction of impacted mandibular third molars by measuring two radiologic variables ; depth and mesial periondontal ligament width.

  • PDF

Predictable Risk Factors for Adjacent Segment Degeneration After Lumbar Fusion

  • Hyun, Seung-Jae;Kim, Young-Baeg;Hong, Hyun-Jong;Kwon, Jeong-Taik;Suk, Jong-Sik;Min, Byung-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.88-94
    • /
    • 2007
  • Objective : The aim of this study is to investigate predictable risk factors for radiologic degeneration of adjacent segment after lumbar fusion and preoperative radiologic features of patients who underwent additional surgery with adjacent segment degeneration. Methods : Between January 1995 and December 2002, 201 patients who underwent lumbar fusion for degenerative conditions of lumbar spine were evaluated. We studied radiologic features, the method of operation, the length of fusion, age, sex, osteoporosis, and body mass index. Special attention was focused on, preoperative radiologic features of patients who required additional surgery were studied to detect risk factors for clinical deterioration. Results : Follow-up period ranged from 3 to 11 years. In our study, 61 [30%] patients developed adjacent segment degeneration, and 15 [7%] patients required additional surgery for neurologic deterioration. Age, the postoperative delay, facet volume, motion range, laminar inclination, facet tropism, and preexisting disc degeneration of adjacent segment considered as possible risk factors. Among these, laminar inclination and preexisting disc degeneration of adjacent segment were significantly correlated with clinical deterioration. Conclusion : The radiologic degeneration of adjacent segment after lumbar fusion can be predicted in terms of each preoperative radiologic factor, age and the postoperative delay. Laminar inclination and preexisting disc degeneration of adjacent segment have shown as strong risk factors for neurologic deterioration. Thus, careful consideration is warranted when these risk factors are present.

Analysis of question-inquire test on the Clinical Specialist system in Radiologic Technologist (전문 방사선사 제도에 관한 설문조사 분석)

  • Yoon Chul Ho;Park Soung Ock
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.269-279
    • /
    • 2001
  • A men who has obtain a license of radiotechnologist from the government engaging in the Dept. of radiology as a technologist at various hospitals. They can engage in various part such as Diagnosis radiology, Radiation therapy, Sonography and Nuclear medic

  • PDF

A Study on the Mixing of Pulverization Matters when the Contrast Medium is connected to the Automatic Injection Device using the Syringe Connector (Syringe Connector를 이용하여 조영제를 자동 주입장치에 연결 시 분쇄물 혼입에 관한 연구)

  • Kim, Hyeon ju;Kim, Ji eun;Han, Yu bean;Choi, Seung hyun;Kang, Yun ki;Jung, Yu jin;Jung, Min young;Lee, Hoo min
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.777-783
    • /
    • 2018
  • The purpose of this study was to investigate the degree of tearing of the rubber when the spike of the syringe connector was connected to the bottle of the contrast medium composed of the rubber compound type and to investigate the presence of the synthetic rubber due to tearing and grinding and the size of the pulverized product when the pulverized matters rubber was detected. As a result, in the case of tearing degree, the front side of the first contact with the end of the syringe connector was torn more than the back side by about $3.14{\pm}0.04mm$, and the pulverized matters was detected on average 7 to 15 on the 10 contrast mediums. The average particle size was measured to be about $7.89{\pm}0.31{\mu}m$. In addition, it is necessary to develop a micro_filter type automatic injection system for blocking off the pulverized matters as well as additional experiments through various experiments and analysis methods, and it is considered that interest of related organizations will be needed in preparation of fatal accidents when pulverized matters is introduced.

ACCURACY OF PREOPERATIVE ASSESSMENTS FOR CERVICAL LYMPH NODE METASTASIS IN ORAL CANCER (구강암 경부임파절 전이에 대한 술전 평가의 정확성)

  • Lee, Jae-Jun;Nam, Woong;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.2
    • /
    • pp.151-156
    • /
    • 2006
  • Purpose : The aim of this study was to determine the accuracy of clinical and radiologic assessments in detecting positive cervical lymph nodes in oral cancer. Materials and Methods : We had reviewed the preoperative clinical, radiologic and postoperative histopathologic reports of 46 patients who had been diagnosed as oral cancer and underwent surgical excision combined with neck dissection (52 sides of neck) in the Department of Oral and Maxillofacial Surgery, College of Dentistry, Yonsei University from the July 1, 1992 to the April 30, 1999. Results : The results were as follows 1. The male to female ratio was 4.38 : 1 and the mean age was 57. 2. Sensitivity values for the preoperative assessment of cervical lymph node metastasis in oral cancer were 62.5 % in clinical examination and 50.0 % in radiologic assessments. Specificity values were 77.8 % in clinical examination and 94.4 % in radiologic assessments. 3. False positive values were 44.4 % in clinical examination and 20.0 % in radiologic assessments. False negative values were 17.6 % in clinical and 19.0% in radiologic assessments. 4. Overall efficiency values were 73.1 % in clinical examination and 80.8 % in radiologic assessments. Summary : There were some limits on the accuracy of clinical and radiologic assessments in the preoperative detection of the cervical lymph nodes in oral cancer. To improve the accuracy, it is important to communicate between clinician and radiologist, and adjunctive diagnostic measures, ultrasound and fine needle aspiration cytology, were helpful increasing the overall efficiency. In the high risk sites (oral tongue and floor of the mouth) the false negative value is higher and the overall efficiency in radiologic evaluation is lower than those of the low risk sites (gingiva and alveolar ridge, retromolar trigone and buccal mucosa ). The elective neck dissection should be considered in the high risk sites.