• Title/Summary/Keyword: radio labeling

Search Result 37, Processing Time 0.03 seconds

Study on Labeling Efficiency of $^{99m}Tc$-HMPAO ($^{99m}Tc$-HMPAO 표지효율에 대한 고찰)

  • Hyeon, Jun Ho;Lim, Hyeon Jin;Kim, Ha Kyun;Cho, Seong Uk;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.131-134
    • /
    • 2012
  • Purpose : The labeling efficiency of radiopharmaceuticals in nuclear medicine is important in terms of accuracy and reliability of the examination. Usually $^{99m}Tc$-HMPAO used for brain SPECT scan is chemically unstable since lots of impurities are existing. Therefore, occurrence of loss of labeling efficiency is easy to appear. In this paper, labeling and use of $^{99m}Tc$-HMPAO should be helpful through experiments on factors affecting the labeling efficiency of $^{99m}Tc$-HMPAO. Materials and Methods : Domestic HMPAO vials (Dong-A) used for brain SPECT scan were tested. Domestic Samyeong Generator 55.5 GBq (1,500 mCi), TLC measurement sets (ITLC-SG, butanone, saline, TLC chamber) and radio-TLC scanner (Advantest, Bioscan) were used. In the first experiment, after eluting generator at 1, 8, 16, 24, 28 hours apart, each eluted $^{99m}Tc$-pertechnetate were labeled with HMPAO and the labeling efficiency was measured. In the second experiment, after eluting $^{99m}Tc$-pertechnetate from a generator, $^{99m}Tc$-pertechnetate was drawn at 0, 1, 3, 6 hours. And each drawn $^{99m}Tc$-pertechnetate were labeled with HMPAO for measuring labeling efficiency. In the third experiment, labeling efficiency was measured at 0, 0.5, 3, 5, 7 hours after labeling $^{99m}Tc$-HMPAO. Results : In the first experiment, measured values were appeared 95.05, 94.64, 94.94, 95.64, 96.76% in passing order of time. In the second experiment, measured values were appeared 94.38, 94.23, 93.26, 91.03% in passing order of time. In the third experiment, measured values were appeared 95.76, 94.17, 88.19, 83.6, 76.86% in passing order of time. Conclusion : In the first experiment of this paper, labeling efficiency of $^{99m}Tc$-HMPAO labeled with $^{99m}Tc$-pertechnetate eluted after 24 hours from first elution. Additional experiments will be needed to discuss for usability. In the second experiment, the labeling efficiency was slightly decreased in chronological order, but it was measured higher than 90%. Also, additional experiments will be needed to discuss for usability. In the third experiment, the labeling efficiency was decreased considerably. Especially, within 3 hours after the labeling is recommended to use $^{99m}Tc$-HMPAO

  • PDF

A Study on the Characteristics of the Intonational Slope of the Korean Broadcasting News Utterances (한국어 방송 뉴스 발화의 억양 기울기 특성 연구)

  • In, Ji-Young;Seong, Cheol-Jae
    • MALSORI
    • /
    • no.66
    • /
    • pp.21-39
    • /
    • 2008
  • The purpose of this study is to analyze the intonational slope characteristics of the Korean news utterances. Prosodic phrases were analyzed in terms of the K-ToBI labeling system. In addition, the change of intonation contour that occurs throughout the sentences was discussed in terms of types of media and gender. Results showed that the overall declination of the intonation contour of radio and male revealed a gentler slope than that of TV and female, respectively. While the regression of the top line slope showed male's higher $R^2$ with the number of words, the base line slope of the radio and female was proved to be highly influenced from the number of syllables, words, and prosodic phrases. A lot more independent variables statistically affected to the base line slope. This means that the base line slope was strongly related to the variables, the top line slope, otherwise, could be more freely fluctuated due to the light correlation with them.

  • PDF

Real-time Slant Face detection using improvement AdaBoost algorithm (개선한 아다부스트 알고리즘을 이용한 기울어진 얼굴 실시간 검출)

  • Na, Jong-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.3
    • /
    • pp.280-285
    • /
    • 2008
  • The traditional face detection method is to use difference picture method are used to detect movement. However, most do not consider this mathematical approach using real-time or real-time implementation of the algorithm is complicated, not easy. This paper, the first to detect real-time facial image is converted YCbCr and RGB video input. Next, you convert the difference between video images of two adjacent to obtain and then to conduct Glassfire Labeling. Labeling value compared to the threshold behavior Area recognizes and converts video extracts. Actions to convert video to conduct face detection, and detection of facial characteristics required for the extraction and use of AdaBoost algorithm.

  • PDF

Direct radio-iodination of folic acid for targeting folate receptor-positive tumors

  • Huynh, Phuong Tu;Lee, Woonghee;Ha, Yeong Su;Yoo, Jeongsoo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.1
    • /
    • pp.3-10
    • /
    • 2018
  • The folate receptor (FR) is a promising cell membrane-associated target for nuclear imaging of various cancers (via imaging $FR-{\alpha}$) and potentially also inflammatory diseases (via imaging $FR-{\beta}$), through the use of folic acid-based radioconjugates. However, there have been several drawbacks of previously reported radioconjugates, such as a short half-life of the radiolabel ($^{68}Ga\;t_{1/2}$ 68 min), a complex and time-consuming multistep radiosynthesis, and a high renal uptake of radiolabeled folate derivatives. The goal of this study was to develop an imaging probe by directly labeling folate with radioactive iodine without using an extra prosthetic group. The radiolabeling of folate was optimized using various labeling conditions and the labeled tracers were isolated by high-performance liquid chromatography. The in vitro stability of labeled folate was checked in phosphate-buffered saline and serum. The tumor-targeting efficacy of the probe was also evaluated by biodistribution studies using a murine 4T1 tumor model.

Fast and Easy Drying Method for the Preparation of Activated [18F]Fluoride Using Polymer Cartridge

  • Seo, Jai-Woong;Lee, Byoung-Se;Lee, Sang-Ju;Oh, Seung-Jun;Chi, Dae-Yoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.71-76
    • /
    • 2011
  • An efficient nucleophilic [$^{18}F$]fluorination has been studied to reduce byproducts and preparation time. Instead of conventional aqueous solution of $K_2CO_3-K_{222}$, several organic solution containing inert organic salts were used to release [$^{18}F$]fluoride ion and anion bases captured in the polymer cartridge, concluding that methanol solution is the best choice. Comparing to azeotropic drying process, one min was sufficient to remove methanol completely, resulting in about 10% radioactivity saving by reducing drying time. The polymer cartridge, Chromafix$^{(R)}$ (PS-$HCO_3$) was pretreated with several anion bases to displace pre-loaded bicarbonate base. Phosphate bases showed better results than carbonate bases in terms of lower basicity. tert-Butanol solvent used as a reaction media played another critical role in nucleophilic [18F]fluorination by suppressing eliminated side product. Consequent [$^{18}F$]fluorination under the present condition afforded fast preparation of reaction solution and high radiochemical yields (98% radio-TLC, 84% RCY) with 94% of precursor remained.

An analysis of a humidifier disinfectant case from a toxicological perspective

  • Park, Kwangsik
    • Environmental Analysis Health and Toxicology
    • /
    • v.31
    • /
    • pp.13.1-13.4
    • /
    • 2016
  • An analysis of patients and fatalities due to exposure to polyhexamethylene guanidine (PHMG) shows that PHMG causes mainly lung diseases such as pulmonary fibrosis. However, no research on the other organs has been conducted on this matter yet. So, an in-depth discussion on toxicological techniques is needed to determine whether or not PHMG is toxic to organs other than just the lungs. For the test of target organ toxicity by PHMG exposure, a toxicokinetic study must first be conducted. However, measurement method for PHMG injected into the body has not yet been established because it is not easy to analyze polymer PHMG, so related base studies on analytical technique for PHMG including radio-labeling chemistry must come first. Moreover, research on exposure-biomarker and effect-biomarker must also be conducted, primarily related to clinical application. Several limitations seem to be expected to apply the biomarker study to the patient because much time has passed after exposure to the humidifier disinfectant. It is why a more comprehensive toxicological researches must be introduced to the causality for the victims.

Issues Related to RFID Security and Privacy

  • Kim, Jong-Ki;Yang, Chao;Jeon, Jin-Hwan
    • 한국경영정보학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.951-958
    • /
    • 2007
  • Radio Frequency Identification (RFID) is a technology for automated identification of objects and people. RFID may be viewed as a means of explicitly labeling objects to facilitate their "perception" by computing devices. RFlD systems have been gaining more popularity in areas especially in supply chain management and automated identification systems. However, there are many existing and potential problems in the RFlD systems which could threat the technology s future. To successfully adopt RFID technology in various applications. we need to develop the solutions to protect the RFID system s data information. This study investigates important issues related to privacy and security of RF1D based on the recent literature and suggests solutions to cope with the problem.

  • PDF

A Study on the Prosodic Characteristics of the Korean Broadcast News Utterances (한국어 정규 뉴스 방송 문장의 운율 특성 연구)

  • In, Ji-Young;Seong, Cheol-Jae
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.197-200
    • /
    • 2007
  • The purpose of this study is to analyze the prosodic characteristics of Korean news utterances. In this paper, prosodic phrases were described in terms of the K-ToBI labeling system. In addition, the change of intonation contour that occurs throughout the sentences was discussed in terms of types of media and gender. According to analyzing the tendency of resets, 331 out of 729 resets were observed at the boundary of the intonation phrases. This means that resets are of the speaker's own volition regardless of prosodic units of intonation phrases. The declination of the intonation contour of radio news showed a gentler slope than that of TV news, because when the sentence is getting longer, the declination of the intonation contour becomes slower.

  • PDF

Synthesis of 68Ga-labeled gold nanoparticles for tumor targeted positron emission tomography imaging

  • Jeon, Jongho;Choi, Mi Hee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.1
    • /
    • pp.46-52
    • /
    • 2015
  • Herein we present the synthesis of $^{68}Ga$-labeled gold nanoparticles for in vivo PET imaging. A novel chelator DTPA-Cys was easily prepared from diethylenetriaminepentaacetic dianhydride in high yield. The ${\alpha}_v{\beta}_3$ integrin receptor targeted gold nanoparticle probe was synthesized by using DTPA-Cys, polyethylene glycol and cRGD peptide. $^{68}Ga$ labeling of cRGD conjugated gold nanoparticle was carried out at $40^{\circ}C$ for 30 min. Observed radiochemical yield was more than 75% as determined by radio-TLC and the probe was purified by centrifugation. In vitro stability test showed that 90% of $^{68}Ga$-labeled gold nanoparticle probe was stable in FBS for 1 h. Those results demonstrated that $^{68}Ga$-labeled gold nanoparticle could be used as a potentially useful probe for specific tumor imaging.

Radioimmunotherapy (I): Development of Radioimmunoconjugates (방사면역치료(I): 방사면역접합체 개발)

  • Choi, Tae-Hyun;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.2
    • /
    • pp.66-73
    • /
    • 2006
  • Monoclonal antibodies are designed to bind specifically to certain antigen, give therapeutic effect to the target and to be produced in large scale with homogeneity. The monoclonal antibodies conjugated with radionuclide can deliver therapeutic irradiation to the target, and showed successful results in certain malignancies, which is known as radioimmunotherapy. The target-to-background ratio depends on the antigen expression in the target and normal tissues, which is related to the therapeutic efficacy and toxicity in radioimmunotherapy. For the solid tumor beta-ray energy should be high, but lower beta energy is better for the hematological malignancies. I-l31 is widely used in thyroid cancer with low cost and high availability. Labeling monoclonal antibody with I-131 is relatively simple and reproducible. Some preclinical data for the I-131 labeled monoclonal antibodies including acute toxicity and efficacy are available from already published literatures in KIRAMS, physician sponsored clinical trial protocols using Rituximab, KFDA approved anti-CD20 chimeric monoclonal antibody and I-131 were approved by KFDA and currently are ongoing.