• Title/Summary/Keyword: radio/high frequency

Search Result 836, Processing Time 0.033 seconds

Study on the Electrical Properties of Amorphous HfInZnO TFTs Depending on Sputtering Power (비정질 하프늄인듐징크옥사이드 산화물 반도체의 공정 파워에 따른 트랜지스터의 전기적 특성 연구)

  • Yoo, Dong-Youn;Chong, Eu-Gene;Kim, Do-Hyung;Ju, Byeong-Kwon;Lee, Sang-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.8
    • /
    • pp.674-677
    • /
    • 2011
  • The dependency of sputtering power on the electrical performances in amorphous HIZO-TFT (hafnium-indium-zinc-oxide thin film transistors) has been investigated. The HIZO channel layers were prepared by using radio frequency (RF) magnetron sputtering method with different sputtering power at room temperature. TOF-SIMS (time of flight secondary ion mass spectrometry) was performed to confirm doping of hafnium atom in IZO film. The field effect mobility (${\mu}FE$) increased and threshold voltage ($V_{th}$) shifted to negative direction with increasing sputtering power. This result can be attributed to the high energy particles knocking-out oxygen atoms. As a result, oxygen vacancies generated in HIZO channel layer with increasing sputtering power resulted in negative shift in Vth and increase in on-current.

On the Development of a Microwave Navigational Aid System Suitable for Small Fishing Boats (마이크로파를 이용한 소형어선용 선위측정방식 개발에 관한 연구)

  • 정세모;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.3 no.1
    • /
    • pp.47-77
    • /
    • 1979
  • A microwave Navigational Aid system is suggested suitable for fishing boats too small to be equipped with Radar or Radio-Direction-Finder. The system proposed here is similar to that of Talking-Beacon developed in Japan, but the distinctive modification proposed is that an increase of sixteen times in peak transmitting power, thus an accompanying increase of coverage, is achieved with the same mean transmitting power as that of Japan without sacrificing the clearness of azimuth information, by adopting a pulse repetition modulation instead of pulse width modulation as in Japan system. An experimental land station transmitter of transmitting frequency of 9, 370MHz and of peak power of 35kw with a microwave beam of 1 degree in horizontal width and 7 degrees in vertical width rotating once every three minutes, and also an experimental receiver of 20-dB in sensitivity and of an assumed cost of 100 dollars, operated by a 12 volts battery source are made, and the sail test results are reported showing that a bearing infromation of an accuracy of within two degrees can be obtainable every three minutes at a distance of as far as 24 miles from the transmitter if the transmitter is located as high as 100 meters above sea-level.

  • PDF

Varition Microstructure for Heat treatment of Thin Films $BaTiO_3$ System ($BaTiO_3$계 세라믹 박막의 열처리에 따른 미세구조변화)

  • Park, Choon-Bae;Song, Min-Jong;Kim, Tae-Wan;Kang, Dou-Yol
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.293-295
    • /
    • 1994
  • Barium Titanate ($BaTiO_3$) is one of the few titanateds which is cubic at room temperature. It has the perovskite structure, high dielectric constant (${\varepsilon}_r=300$) and a small temperature coefficient of resistance due to it's Low transition temperature ($Tc=120^{\circ}c$). PTCR (Positive Temperature Coefficient of Resistivity) thermistor in thin film $BaTiO_3$ system was prepared by using radio frequency (13.56MHz) and BC magnetron sputter equipment. Polycrystalline, and surface structure characteristics of the specimens were measured by X-ray diffraction (D-Max3, Rigaku, Japan), SEM(Scanning Electron Microscopy: M. JSM84 01, Japan), respectively. Temperature at below $600^{\circ}C$, $1000^{\circ}C$ to $700^{\circ}C$, and above $1100^{\circ}C$ for spotted $BaTiO_3$ thin films showed the amorphous, degree of crystal growth, and polycrystalline, respectively.

  • PDF

Violet Photoluminescence Emitted from Al-doped ZnO Thin Films (Al 도핑된 ZnO 박막에서 방출되는 보라색 발광 스펙트럼)

  • Hwang, Dong-Hyun;Son, Young-Guk;Cho, Shin-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.4
    • /
    • pp.318-324
    • /
    • 2007
  • We report on a strong violet luminescence emitted from the ZnO:Al films grown on glass substrate by radio-frequency magnetron sputtering. The growth of high-quality thin films and their optical properties are controlled by adjusting the mixture ratio of Ar and $O_2$, which is used as the sputtering gas. The crystallinity of the films is improved as the oxygen flow ratio is decreased, as evidenced in both x-ray diffractometer and atomic force microscope measurements. As for the violet luminescence measured by photoluminescence (PL) spectroscopy, the peak energy and intensity of the PL signal are decreased with increasing the oxygen flow ratio. The peak energy of the violet PL spectrum for the thin film with an oxygen flow ratio of 50 % is almost constant, regardless of the increase of laser Power and temperature. These results indicate that the violet PL signal is probably due to defects related to interstitial Zn atoms.

Effect of CrN barrier on fuel-clad chemical interaction

  • Kim, Dongkyu;Lee, Kangsoo;Yoon, Young Soo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.724-730
    • /
    • 2018
  • Chromium and chromium nitride were selected as potential barriers to prevent fuel-clad chemical interaction (FCCI) between the cladding and the fuel material. In this study, ferritic/martensitic HT-9 steel and misch metal were used to simulate the reaction between the cladding and fuel fission product, respectively. Radio frequency magnetron sputtering was used to deposit Cr and CrN films onto the cladding, and the gas flow rates of argon and nitrogen were fixed at certain values for each sample to control the deposition rate and the crystal structure of the films. The samples were heated for 24 h at 933 K through the diffusion couple test, and considerable amount of interdiffusion (max. thickness: $550{\mu}m$) occurred at the interface between HT-9 and misch metal when the argon and nitrogen were used individually. The elemental contents of misch metal were detected at the HT-9 through energy dispersive X-ray spectroscopy due to the interdiffusion. However, the specimens that were sputtered by mixed gases (Ar and $N_2$) exhibited excellent resistance to FCCI. The thickness of these CrN films were only $4{\mu}m$, but these films effectively prevented the FCCI due to their high adhesion strength (frictional force ${\geq}1,200{\mu}m$) and dense columnar microstructures.

A Study on Adhesive Properties of Cellulose Triacetate Film by Argon Low Temperature Plasma Treatment (아르곤 저온 플라즈마 처리에 의한 CTA 필름의 접착성 연구)

  • Koo Kang;Park Young Mi
    • Textile Coloration and Finishing
    • /
    • v.16 no.5
    • /
    • pp.28-34
    • /
    • 2004
  • The polarizing film application exploits the unique physicochemical properties between PVA(Poly vinyl alcohol) film and CTA(Cellulose triacetate) film. However, hardly any research was aimed at improving the adhesion characteristics of the CTA film by radio frequency(RF) plasma treatment at argon(Ar) gaseous state. In this report, we deal with surface treatment technology for protective CTA film developed specifically for high adhesion applications. After Ar plasma, surface of the films is analyzed by atomic force microscopy(AFM), roughness parameter and peel strength. Furthermore, the wetting properties of the CTA film were studied by contact angle analysis. Results obtained for CTA films treated with a glow discharge showed that this technique is sensitive to newly created physical functions. The roughness and peel strength value increased with an increase in treatment time for initial treatment, but showed decreasing trend for continuous treatment time. The result of contact angle measurement refer that the hydrophilicity of surface was increased. AFM studies indicated that no considerable change of surface morphology occurred up to 3 minutes of treatment time, but a considerable uneven of surface structure resulted from treating time after 5 minutes.

Development of GNSS-only On The Move-RTK Technique for Highly Maneuvering Ground Vehicles

  • Jeon, Jong-Hwa;Yoo, Sang-Hoon;Choi, Jeung-Won;Sung, Tae-Kyung
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.4
    • /
    • pp.235-243
    • /
    • 2018
  • Conventional Real Time Kinematics (RTK) collect measurements in stationary state for several minutes to resolve the integer ambiguity in the carrier phase measurement or resolve the integer ambiguity on the move assuming low maneuvering movement. In this paper, an On The Move-RTK (OTM-RTK) technique that resolves the integer ambiguity on the move for fast and precise positioning of ground vehicles such as high maneuvering vehicles was proposed. The OTM-RTK estimates the precise amount of movement between epochs using the carrier phase measurements acquired on the move, and by using this, resolves the integer ambiguity within a short period of time by evaluating the integer ambiguity candidates for each epoch. This study analyzed the integer ambiguity resolution performance using field driving experiment data in order to verify the performance of the proposed method. The results of the experiment showed that the precise trajectory including the initial position bias can be obtained prior to resolving the integer ambiguity, and after resolving the integer ambiguity on the move, it was possible to obtain the bias-corrected precise position solution. It was confirmed that the integer ambiguity can be resolved by collecting measurements of about 10 epochs from the moving vehicle using a dual frequency receiver.

Multi-antenna diversity gain in terrestrial broadcasting receivers on vehicles: A coverage probability perspective

  • Ahn, Sungjun;Lee, Jae-young;Lim, Bo-Mi;Kwon, Hae-Chan;Hur, Namho;Park, Sung-Ik
    • ETRI Journal
    • /
    • v.43 no.3
    • /
    • pp.400-413
    • /
    • 2021
  • This paper theoretically and empirically explores the reliability gain that can be obtained by installing multiple antennas in on-vehicle broadcasting receivers. Analytical derivations reveal that maximal-ratio-combining-based diversity allows a multi-antenna receiver (MR) to achieve significantly better coverage probability than a single-antenna receiver (SR). In particular, the notable MR gains for low-power reception and high-throughput services are highlighted. We also discuss various aspects of mobile MRs, including geometric coverage, volume of the users served, and impact of receiver velocity. To examine the feasibility of MRs in the real world, extensive field experiments were conducted, particularly with on-air ATSC 3.0 broadcast transmissions. Relying on the celebrated erroneous second ratio criterion, MRs with two and four antennas were verified to achieve notable reliability gains over SRs in practice. Furthermore, our results also prove that layered-division multiplexing can cope better with receiver mobility than traditional time-division multiplexing when multiple services are intended in the same radio frequency channel.

Performance Analysis of M-ary Optical Communication over Log-Normal Fading Channels for CubeSat Platforms

  • Lim, Hyung-Chul;Yu, Sung-Yeol;Sung, Ki-Pyoung;Park, Jong Uk;Choi, Chul-Sung;Choi, Mansoo
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.219-228
    • /
    • 2020
  • A CubeSat platform has become a popular choice due to inexpensive commercial off-the-shelf (COTS) components and low launch cost. However, it requires more power-efficient and higher-data rate downlink capability for space applications related to remote sensing. In addition, the platform is limited by the size, weight and power (SWaP) constraints as well as the regulatory issue of licensing the radio frequency (RF) spectrum. The requirements and limitations have put optical communications on promising alternatives to RF communications for a CubeSat platform, owing to the power efficiency and high data rate as well as the license free spectrum. In this study, we analyzed the performance of optical downlink communications compatible with CubeSat platforms in terms of data rate, bit error rate (BER) and outage probability. Mathematical models of BER and outage probability were derived based on not only the log-normal model of atmospheric turbulence but also a transmitter with a finite extinction ratio. Given the fixed slot width, the optimal guard time and modulation orders were chosen to achieve the target data rate. And the two performance metrics, BER and outage data rate, were analyzed and discussed with respect to beam divergence angle, scintillation index and zenith angle.

Intraoperative Tumor Localization of Early Gastric Cancers

  • Jeong, Sang-Ho;Seo, Kyung Won;Min, Jae-Seok
    • Journal of Gastric Cancer
    • /
    • v.21 no.1
    • /
    • pp.4-15
    • /
    • 2021
  • Recently, endoscopic screening systems have enabled the diagnosis of gastric cancer in the early stages. Early gastric cancer (EGC) is typically characterized by a shallow invasion depth and small size, which can hinder localization of EGC tumors during laparoscopic surgery. Here, we review nine recently reported tumor localization methods for the laparoscopic resection of EGCs. Preoperative dye or blood tattooing has the disadvantage of spreading. Preoperative 3-dimensional computed tomography reconstruction is not performed in real time during laparoscopic gastrectomy. Thus, they are considered to have a low accuracy. Intraoperative portable abdominal radiography and intraoperative laparoscopic ultrasonography methods can provide real-time feedback, but these methods require expertise, and it can be difficult to define the clips in some gastric regions. Despite a few limitations, intraoperative gastrofibroscopy provides real-time feedback with high accuracy. The detection system using an endoscopic magnetic marking clip, fluorescent clip, and radio-frequency identification detection system clip is considered highly accurate and provides real-time feedback; we expect a commercial version of this setup to be available in the near future. However, there is not yet an easy method for accurate real-time detection. We hope that improved devices will soon be developed and used in clinical settings.