• 제목/요약/키워드: radiation sources

검색결과 590건 처리시간 0.051초

Experimental study of the radiation shielding characteristics of new PbO-Na2O-B2O3-BaO glasses

  • M.I. Sayyed;U. Rilwan;K.A. Mahmoud;Mohamed Elsafi
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2437-2443
    • /
    • 2024
  • This work synthesized four glass samples with a fixed ratio of PbO to Na2O and a variable ratio of BaO to B2O3. The linear attenuation coefficient (LAC) (μ, cm-1) and additional attenuator parameters were determined experimentally using a semiconductor detector and different gamma sources. The comparison was carried out between the experimental and the XCOM calculated results, with good agreement emerging between the two results. The impacts of the BaO substituting for the B2O3 on fabricated PNBB glasses' radiation shielding properties were discussed. By increasing the BaO substitution concentration between 10 and 25 mol.%, the LAC μ values (cm-1) increased by 76.60 %, 13.81 %, 12.56 %, and 12.52 % for the respective γ-ray energies of 0.059, 0.662, 1.173, and 1.332 MeV. The μ value reduction with raised gamma energy values increased the values of the calculated half-value thickness (Δ0.5) as a result of the μ and Δ0.5 values' reverse proportionality. Other shielding parameters such as the lead equivalent thickness (Δeq) and radiation protection efficiency were also determined for the present PNBB glass samples.

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제35권2호
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • 방사성폐기물학회지
    • /
    • 제21권3호
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가 (An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility)

  • 지영용;곽경길;홍대석;손종식
    • 방사성폐기물학회지
    • /
    • 제10권2호
    • /
    • pp.117-123
    • /
    • 2012
  • 한국원자력연구원 내 저장중인 중 저준위방사성폐기물의 안전한 영구처분을 위하여 방사성폐기물처리시설에서는 이들 저장폐기물의 핵종재고량 평가를 위한 드럼핵종분석장치의 도입을 기획하고 있으며, 이 장치를 운영하고 유지보수하기 위한 전용의 평가시설 구축을 추진하고 있다. 이 평가시설 외부에는 제1방사성폐기물저장시설이 인접하여 있으며 내부에는 평가대상드럼들과 드럼핵종분석장치의 밀도보정용 선원 등이 존재함으로 이들이 방사선원항으로 작용하여 평가시설 내 외부의 선량률에 영향을 미치게 된다. 따라서 방사선원항 주변의 콘크리트 구조물에 대한 방사선차폐 영향을 평가하여야 한다. 본 연구에서는 MCNP 코드를 이용하여 해당 방사선원항으로부터 평가시설 내부 방사선관리구역을 둘러싸고 있는 콘크리트 구조물에 대한 방사선 안전성을 평가하였다. 평가결과 현재 고려되고 있는 콘크리트 구조물의 약 30 cm 두께는 해당 방사선원항으로부터의 방사선을 차폐하기에 충분한 것으로 확인되었다.

Shielding Evaluation and Activation Analysis of Facilities by Neutron Generator for the Development of 20 Feet Container Inspection System

  • Jin-Woo Lee;Dae-Sung Choi;Gyo-Seong Jeong
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.443-449
    • /
    • 2023
  • KAERI(Korea Atomic Energy Research Institute) is conducting research and development of large-scale radiation generators and the latest radiation measuring instruments. In particular, research and development of security screening equipment using an electron beam accelerator and a neutron generator is in progress recently. Globally, 20 ft containers are used to transport imports and exports, and electron beam accelerators are radiation sources to measure the shape of the material inside the container during customs inspections in each country. KAERI is developing a device that can use an electron beam accelerator and a neutron generator sequentially to grasp the shape of various materials as well as the location of the internal target material. In this study, when using the neutron generator, the radiation dose and the degree of activation by neutron for the facility and surrounding environment, facility equipment were simulated using MCNP and FISPACT code. As a result, the shielding structures inside and outside the radiation control area were satisfactory to the reference level established conservatively based on the Korean Nuclear Act.

KOREAN VLBI NETWORK CALIBRATOR SURVEY (KVNCS): 1. SINGLE DISH FLUX MEASUREMENT IN THE K AND Q BANDS

  • Lee, Jeong Ae;Sohn, Bong Won;Jung, Taehyun;Byun, Do-Young;Lee, Jee Won
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.32.2-32.2
    • /
    • 2016
  • We present the catalog of the KVN Calibrator Survey (KVNCS). This first part of the KVNCS is a single dish radio survey conducted at 22 (K band) and 43 GHz (Q band) simultaneously using the Korean VLBI Network (KVN) from 2009 to 2011. A total 2045 sources selected from the VLBA Calibrator Survey (VCS) with an extrapolated flux limit of 100 mJy at K band. The KVNCS contains 1533 sources in the K band with a flux limit of 70 mJy and 553 sources in the Q band with a flux limit of 120 mJy; it covers the whole sky down to -32. ${\circ}$ 5 in declination. Five hundred thirteen sources were detected in the K and Q bands, simultaneously; ~76% of them are flat-spectrum sources ($-0.5{\leq}{\alpha}{\leq}0.5$). From the flux-flux relationship, we anticipated that the most of the radiation of many of the sources comes from the compact components. Therefore, the sources listed in the KVNCS are strong candidates for high frequency VLBI calibrators.

  • PDF

Ir-192 방사선원의 밀봉 용접부 품질에 미치는 저항용접 공정변수의 영향 (The Effect of Process Parameters on Sealing Quality for Ir-192 Radiation Source Capsule using Resistance Spot Welding)

  • 한인수;손광재;이영호;이유황;이준식;장경덕;박울재;박춘득
    • Journal of Welding and Joining
    • /
    • 제27권1호
    • /
    • pp.65-70
    • /
    • 2009
  • Ir-192 radiation sealed sources are widely employed to the therapeutic applications as well as the non-destructive testing. Production of Ir-192 sources requires a delicate but robust welding technique because it is employed in a high radioactive working environment. A GTA(Gas Tungsten Arc) welding technique is currently well established for this purpose. However, this welding method requires a frequent replacement of the electrode, which results in the delay of the production to take a preparatory action such as to isolate the radiation sources from the working place before getting access to the welding machine. Hence, a resistance welding technique is considered as an alternative method of the GTA welding technique. The advantages of resistance welding are high welding speed and high-rate production. Also it has very long life of electrode comparing to GTA welding. In this study, the resistance welding system and proper welding conditions were established for sealing Ir-192 source capsule. As a results of various experiments, it showed that electrode displacement can be employed as a indicator to predict welding quality. We proposed two mathematical models(linear and curvilinear) to estimate electrode displacement with process parameters such as applied force, welding current and welding time by using regression analysis method. Predicting results of both linear and curvilinear model were relatively good agreement with experiment.

항공기 외부소음 예측기법의 개발 (Development of the prediction method of aircraft exterior noise)

  • 심인보;이덕주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.78-83
    • /
    • 2000
  • Exterior noise generated by the aircraft induces a serious noise pollution near the airport. For the prediction of an exterior noise radiation of aircraft an empirical formula is employed to model the acoustic sources. It is shown that the fan/compressor noise is the most dominant part of the acoustic sources in all cases.

  • PDF

방사가열원이 Si의 흡수효과와 OSF 성장에 미치는 영향 (Influence of Radiation Heating Sources on the Absorption Effect and Growth of OSF in Si)

  • 홍순관;김철주;이철승;정관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.332-334
    • /
    • 1988
  • Influence of incoherent lamp heating sources on the absorption effect and variation of OSF' size were investigated. The absorption effect on I.R lamp caused by free carrier excitation is greater than that of Tungsten-Halogen lamp. The variation of DSF' size weakly affected by oxidation time.

  • PDF